BK-UV002 Ver.1.0
Air Valve
HIGH CYCLE SOLENOID VALVE
INSTRUCTION MANUAL Ver.1.0
Dimensions (mm)
Approximately
300
48
10
10
54
40
1(P)
2(A)
2-Rc1/4
38
30
Flow Rate
MPa
0.7
Supply pressure
(MPa)
0.7
4-M5×0.8 Depth 6
Mounting thread
Valve outlet pressure
0.6
0.5
0.6
0.5
0.4
0.4
0.3
0.3
0.2
0.1
0
0.2
0.1
200
400
600
800
Flow rate R/min(ANR)
1MPa = 145psi., 1R/min = 0.0353ft.3/min.
Handling Instructions and Precautions
Solenoid
Internal circuit
Solenoid
Lead wire: Red
Replacement
of valves
The high cycle solenoid valve
construction allows solenoid and
valve body can be removed from the
base (piping portion), which means
that the valve can easily be replaced
without removing the piping.
Loosen the 4 mounting screws on the
top of the valve, and remove the
solenoid and valve body from the
base.
Continuously energized time
In high cycle solenoid valves, energizing continuously for too long can
result in reduced performance or
valve shutdown. Continuously energized time should be limited to 30
seconds or less.
In addition, maintain the duty ratio
(ON time/OFF time) at 1.0 or below. If
your application requires continuous
energizing in excess of the above
recommendations, consult us.
The order code for the replacement
valve body only (including solenoid) is
HV160E1-2-M.
Caution: Do not attempt to disassemble the valve body.
HIGH CYCLE
SOLENOID VALVE
Specifications
Specifications
Model
Item
Media
HV160E1-2
Air
Operation type
Direct acting type
Order Code
Number of ports
2
HV160E1-2 DC24V
Valve function
Number of positions
The high cycle solenoid valve
supports improved equipment
performance.
Flat armature and separated valve reduce
shocks at valve seat and inertial mass to a
minimum, achieving reliability for highfrequency operations.
■High durability offers huge
reductions in maintenance costs.
mm2
Effective area〔Cv〕
Rc 1/4
Lubrication
Not required
Operating pressure range
MPa {kgf/cm2} [psi.]
0〜0.7 {0〜7.1} [0〜102]
Proof pressure
MPa {kgf/cm2} [psi.]
1.05 {10.7} [152]
Response time Note ON/OFF
ms
10/5 or below
Maximum operating frequency
Hz
25
Operating temperature range (atmosphere and media) °C [°F]
5〜50 [41〜122]
Lateral direction
1373.0 {140.0}
Axial direction
294.2 {30.0}
Life cycle
times
Over 5×108
Mass
g [oz.]
300 [10.58]
m/s2 {G}
Mounting direction
Any
Note: Values when air pressure is 0.5MPa {5.1kgf/cm2} [73psi.] and rated voltage are
applied. Also, the use of a flywheel diode or similar circuit for surge suppression
increases the response time.
Solenoid Specifications
Rated voltage
Item
Type
DC24V
DC solenoid
Operating voltage range
Offers long life of 500 million operations to
increase interval between maintenance
periods. Holds loss time to a minimum,
achieving highly efficient device operations.
7.0〔0.39〕
Port size
Shock resistance
■Simple poppet type structure offers
reliability.
2
Normally closed(NC)
V
21.6〜26.4(24±10%)
Current(When rated voltage is applied)
mA
420(10W)
Insulation resistance
MΩ
Wiring and lead wire length
Over 100
Grommet type:300mm [11.8in.]
Color of lead wire
Red
Operating Principle and Symbol
Molded solenoid
Spring
De-energized
Normally
closed (NC)
Valve (seal)
Armature
Damper
O-ring
Gasket
Plate
Body
1(P)
2
(A)
1(P)
2(A)
Major Parts and Materials
Stopper
Parts
Body
Base
O-ring
Materials
Aluminum alloy (anodized)
Armature
Magnetic stainless steel
Valve (seal)
Synthetic rubber (urethane)
Damper
Synthetic rubber (urethane)
">