Koganei Solenoid Valve JE Series Instruction manual
Koganei Solenoid Valve JE Series is a versatile and reliable air valve designed for various applications. It features a compact design and a variety of mounting options. The JE Series includes single and double solenoid valves, with 2, 3, and 5 ports, offering both normally closed (NC) and normally open (NO) valve functions. The JE Series valves are available in standard, low-current and quick-response types. The low-current and quick-response types utilize a timer circuit for improved power consumption, and the quick-response type offers faster switching times. The JE Series also includes manual override options for both non-locking and locking types, providing additional control and safety.
Advertisement
Advertisement
BK-UV002 Ver.1.0 Air Valve SOLENOID VALVES JC JE SERIES INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Plug connector Solenoid Internal circuit ● DC12V, DC24V (Standard type) Solenoid with LED indicator and surge suppression Lead wire (+) Red (Red) Attaching and removing plug connector Side mounting precautions (JE series) Use fingers to insert the connector into the pin, push it in until the lever claw latches onto the protruded section of the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the protruded section of the connector housing, and pull it out. When using a JE series single solenoid valve unit in a side mounting, as shown in the diagram below, mounting base -22 for the side mounting is required, because the fitting interferes with the mounting surface. The TS6-M5 and TL6-M5 quick fitting standard types for the 6mm tube cannot be mounted. Use the hexagon socket straight fitting or the quick fitting mini type instead. Lead wire Black(−) Protruded section Pin Housing ● DC24V (Low current, quick response types) Solenoid with LED indicator and surge suppression Lever Connector assembly Lead wire Red(+) Lead wire Black(−) (Red) Indication of polarity (DC) Connector Contact Timer circuit Manual override Non-locking type Cautions: 1. Do not apply megger between the pins. 2. Leakage current inside the circuit could result in failure of the solenoid valve to return to the rest position or other erratic operation. Always use it at less than the allowable leakage current shown in the solenoid specifications on p.235, and 249. If circuit conditions, etc. cause the leakage current to exceed the maximum allowable leakage current, consult us. 3. For the double solenoid configuration, avoid energizing both solenoids simultaneously. 4. The standard housing type is colored blue, while the low current type is light blue, and the quick response type is white. 5. The low current and quick response types will not activate when the power supply voltage is raised too slowly. Always apply the appropriate voltage. Operating principles of low current and quick response types The low current and quick response types use a timer circuit, as shown above, that achieves power savings by switching to the holding operations mode after a certain period of time and operates at about 1/3 of the starting power consumption. ● Power waveform for low current type Power consumption Solenoid valves ON 0.55W OFF Reduced power consumption 0.15W Crimping of connecting lead wire and contact To crimp lead wires into contacts, strip off 4mm [0.16in.] of the insulation from the end of the lead wire, insert it into the contact, and crimp it. Be sure to avoid catching the insulation on the exposed wire crimping section. Exposed wire 4mm [0.16in.] Contact Hook Lead wire Equivalent to Insulation crimp AWG#22〜#28 tab Insulation Exposed wire (Maximum outer diameter: φ1.7) crimping section To operate the manual override, press it all the way down. For the single solenoid, the valve works the same as when in the energized state as long as the manual override is pushed down, and returns to the rest position upon release. For the double solenoid, pressing the manual override on the 14 (SA) side switches the 14 (SA) to the energized state, and the valve remains in that state even after the manual override is released. To return it to the rest position, operate the manual override on the 12 (SB) side. This is the same for the solenoid 12 (SB). Cautions: 1. Do not pull hard on the lead wire. 2. Always use a dedicated tool for crimping of connecting lead wire and contact. Contact: Model 702062-2M Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1-702062 Manufactured by Sumiko Tech, Inc. PU SH Attaching and removing contact and connector Insert the contact with lead wire into a plug connector □ hole until the contact hook latches on and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove it, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. Locking type To lock the manual override, use a small screwdriver to push down on the manual override all the way down and turn it clockwise 45 degrees. When locked, turning the manual override 45 degrees in the counterclockwise direction returns it to its rest position, and releases the lock. (Excluding the quick response type) Start-up time(200ms or below) ● Power waveform for quick response type Power consumption Solenoid valves 3W 1.1W ON OFF Reduced power consumption Start-up time(30ms or below) Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc. 2. If the pin is bent, use a small screwdriver, etc. to gently straighten out the pin, and then complete the connection to the plug connector. TURN Handling Instructions and Precautions Manifold Lever type (JE series only) Mounting on a DIN rail (A type manifold) ● Vertical mounting To lock the manual override, push the manual lever all the way down and turn it clockwise 90 degrees. When locked, turning the manual lever 90 degrees in the counterclockwise direction returns it to its rest position and releases the lock. When the manual lever is not turned, this type acts just like the nonlocking type, and the valve remains in the energized state as long as the manual lever is pushed down, and returns to the rest position upon release. The manual lever is equipped with a safety plate to avoid erroneous operation. Care should be taken that the safety plate cannot be operated when the manual lever is locked in place. With the DIN rail mounting bracket option, a mounting bracket and mounting screw are provided. First, use the mounting screw to temporarily secure the mounting bracket on the manifold. When mounting the manifold in a vertical direction, mount it so that the release lever is pointing downward. Mounting screw 1 (P) 3 (R) 1 (P) ● Mounting qApproaching from the direction shown in the diagram, let the mounting bracket hook latches onto the DIN rail fringe, then press down the manifold to secure the bracket onto the DIN rail. ON PUSH KEEP Mounting bracket 3 (R) Manual lever Safety plate Caution: Caution should be taken not to drop the manifold. Release lever Mounting a valve on the manifold When mounting a valve on the manifold, the recommended tightening torque for the valve mounting screw is 14.7N・cm {1.5kgf・ cm} [1.30in・lbf]. (P) 1 LOCK Locked position 90° (R) 3 Push down and turn ●Safety plate operation qCheck that the manual lever is in the off position. wSlide the center of the safety plate in the direction shown by the arrow until it comes to a stop, at a distance of about 3mm [0.12in.]. In this position, the manual lever can no longer be pushed in. eTo release the safety plate, slide it in the direction opposite to that shown by the arrow until it comes to a stop. Manual lever (Off position) Safety plate KEEP ON PUSH LOCK Slide Cautions: 1. The JC and JE series are pilot type solenoid valves. As a result, the manual override button or manual lever cannot switch the main valve without air supplied from the 1(P) port. 2. Always release the lock of the manual override button or manual lever before commencing normal operation. 3. Do not attempt to operate the manual override button or manual lever with a pin or other object having an extremely fine tip. It could damage the button. 4. For the lever type, do not apply excessive force when sliding the safety plate. It could result in a breakdown. (Recommended force: 3N) wTo ensure that the mounting bracket is firmly set against the bottom of the manifold, tighten the mounting screw to secure the DIN rail in place. Recommended tightening torque: 98N・cm {10kgf・cm} [8.7in・lbf] 1 (P) Tightening 3 (R) Caution: Since the mounting bracket cannot slide along the DIN rail once it is set onto the rail, make sure to set the manifold in the appropriate position beforehand. ● Removing qLoosen the mounting screw and lift the manifold off and away from the mounting bracket. wInsert a flatblade screwdriver, etc. underneath the mounting bracket’s release lever, and gently pry it away to remove the mounting bracket. 1 (P) 3 (R) Release lever Tube 1. Attaching and removing tubes For tube connection, insert an appropriate size tube until it comes into contact with the tube stopper, and lightly pull it to check the connection. For tube removal, push the tube against the tube stopper, then push the release ring and at the same time pull the tube out. 2. Either a nylon or urethane tube can be used. Use tubes with an outer diameter tolerance within ±0.1mm [±0.004in.] of the nominal diameter, and ensure the ovalness (difference between large diameter and small diameter) is 0.2mm [0.008in.] or less. (Using Koganei tubes is recommended.) Cautions: 1. Do not use extra-soft tubes since their pull-out strength is significantly reduced. 2. Only use tubes without scratches on their outer surfaces. If a scratch occurs during repeated use, cut off the scratched section. 3. Do not bend the tube excessively near the fittings.The minimum bending radius is as shown in the table below. 4. When attaching or removing tubes, always stop the air supply. In addition, always confirm that air has been completely exhausted from the manifold. mm [in.] Tube size Cautions: Spring force from the mounting bracket’s plate could cause the bracket to pop out during the removal operation. To ensure safety, proceed with caution during the operation. In addition, always use a flatbrade screwdriver, etc. when removing the mounting bracket from the DIN rail. Never use your fingers because of the danger of serious injury due to the potential strong forces. Minimum bending radius Nylon tube Urethane tube φ4 20 [0.79] 10 [0.39] φ6 30 [1.18] 15 [0.59] φ8 50 [1.97] 20 [0.79] φ3 7 [0.28] JC SERIES SPECIFICATIONS Specifications Basic Models and Functions JC10□F1Note JC10□F2Note JC10□F3Note JC10□F4Note JC10□A1Note JC10□A2Note JC10□A3Note JC10□A4Note Basic model For direct piping, F type manifolds For base piping, A type manifolds Item Number of positions JC10□F5 JC10□F6 JC10□F7 JC10□F8 JC10□F9 JC10□A5 JC10□A6 JC10□A7 JC10□A8 JC10□A9 3 positions 2 positions Number of ports 2, 3 ports Valve function Single solenoid NC, NO 5 ports Single solenoid Double solenoid Closed center, Exhaust center, Pressure center Remark: For the optional specifications and order codes, see p.239. Note: Valves with valve specifications F1, F2, F3, F4, A1, A2, A3, and A4 are for mounting on manifolds only, and cannot be used as single valve units. Specifications JC10□F1 JC10□F2 JC10□F3 JC10□F4 JC10□A1 JC10□A2 JC10□A3 JC10□A4 Basic model For direct piping, F type manifolds For base piping, A type manifolds Item JC10□F5 JC10□F6 JC10□F7 JC10□F8 JC10□F9 JC10□A5 JC10□A6 JC10□A7 JC10□A8 JC10□A9 Media Air Operation type Internal pilot type Flow rate characteristicsNote 1 Sonic conductance C dm 3/(s・bar) 0.6 Port sizeNote 2 M5×0.8 Lubrication Not required Operating pressure range MPa {kgf/cm2 }[psi.] Proof pressure Response timeNote 3 ON/OFF 0.2〜0.7 {2〜7.1} [29〜102] MPa {kgf/cm2 }[psi.] ms Maximum operating Hz frequency 0.25〜0.7 {2.5〜7.1} [36〜102] 1.05 {10.7} [152] Standard type 10/20 or below 12 or below 10/30 or below Low current type (L) 10/50 or below 12 or below 10/60 or below Quick response type (S) 6/7 or below 6 or below 6/12 or below 50 ― Standard type 5 Low current type (L) 2 Quick response type (S) ms Minimum time to energize for self holdingNote 4 10 ― Operating temperature range (atmosphere and media) °C [°F] m/s2 {G} Shock resistance 5〜50 [41〜122] 1373.0 {140} (Axial direction 294.2 {30}) Mounting direction 1373.0 {140} (Axial direction 147.1 {15}) 1373.0 {140} (Axial direction 195.0 {20}) Any Notes: 1. For details, see the flow rate characteristics on p.236. 2. For details, see the port size on p.237. 3. Values when air pressure is 0.5MPa [73psi.]. The values for the 3-position valves are switching time from the neutral position. 4. For double solenoid valve. Solenoid Specifications Rated voltage Item Operating voltage range DC24V (Standard type) DC24V (Low current type) DC24V (Quick response type) 10.8〜13.2 21.6〜26.4 21.6〜26.4 21.6〜26.4 (12±10%) (24±10%) (24±10%) (24±10%) ― Standard type Current (when rated voltage is applied) mA (r.m.s) 46 23 ― Power consumption W 0.55 0.55 ― ― Low current type Quick response type V DC12V (Standard type) Current (when rated Starting mA voltage is applied) Holding mA ― ― 23 125 46 Power consumption ― ― 6.3 Starting W ― ― 0.55 3 Holding W ― ― 0.15 1.1 Start-up time (standard time) ms ― ― 200 or below 30 or below Allowable leakage current mA 2 1 0.5 4 Insulation resistance MΩ Color of LED indicator Surge suppression (as standard) Over 100 (value at DC500V megger) Red Flywheel diode Flow Rate Characteristics The test method for flow rate characteristics conforms to JIS B 8390:2000 (test method for pneumatic equipment — equipment for compressible fluids — flow rate characteristics). ●When used as a single unit (with fittings) Basic model Flow path Sonic conductance C dm3/(s・bar) Critical pressure ratio b 1(P)→ 4(A) ― ― JC10□F5 1(P)→ 2(B) ― ― JC10□F6 4(A)→ 5(R1) ― ― 2(B)→ 3(R2) ― ― 1(P)→ 4(A) ― ― 1(P)→ 2(B) ― ― 4(A)→ 5(R1) ― ― Direct piping Note 1 JC10□F7 JC10□F8 JC10□F9 Effective area S mm2〔Cv〕 2.80〔0.156〕 2.50〔0.139〕 2(B)→ 3(R2) ― ― 1(P)→ 4(A) 0.58 0.40 2.90〔0.161〕Note 3 JC10□A5 1(P)→ 2(B) 0.57 0.37 2.85〔0.158〕Note 3 JC10□A6 4(A)→ 5(R1) 0.51 0.29 2.55〔0.142〕Note 3 2(B)→ 3(R2) 0.61 0.26 3.05〔0.169〕Note 3 1(P)→ 4(A) 0.52 0.36 2.60〔0.144〕Note 3 1(P)→ 2(B) 0.53 0.33 2.65〔0.147〕Note 3 4(A)→ 5(R1) 0.49 0.27 2.45〔0.136〕Note 3 2(B)→ 3(R2) 0.55 0.27 2.75〔0.153〕Note 3 Flow path Sonic conductance C dm3/(s・bar) Critical pressure ratio b Effective area SNote 3 mm2〔Cv〕 Note 1 Base piping (with sub-base) JC10□A7 JC10□A8 JC10□A9 ●When mounted on a manifold (with fittings) Basic model F type manifold Note 2 (direct piping type) JC10□F1 JC10□F2 JC10□F3 JC10□F4 JC10□F5 JC10□F6 JC10□F7 JC10□F8 JC10□F9 A type manifold Note 2 (base piping type) JC10□A1 JC10□A2 JC10□A3 JC10□A4 JC10□A5 JC10□A6 JC10□A7 JC10□A8 JC10□A9 1(P)→4(A) 0.66 0.54 3.30〔0.183〕 1(P)→2(B) 0.62 0.46 3.10〔0.172〕 4(A)→5(R1) 0.58 0.33 2.90〔0.161〕 2(B)→3(R2) 0.55 0.14 2.75〔0.153〕 1(P)→4(A) 0.56 0.41 2.80〔0.156〕 1(P)→2(B) 0.56 0.42 2.80〔0.156〕 4(A)→5(R1) 0.53 0.32 2.65〔0.147〕 2(B)→3(R2) 0.50 0.13 2.50〔0.139〕 1(P)→4(A) 0.61 0.33 3.05〔0.169〕 1(P)→2(B) 0.60 0.31 3.00〔0.167〕 4(A)→5(R1) 0.61 0.08 3.05〔0.169〕 2(B)→3(R2) 0.60 0.08 3.00〔0.167〕 1(P)→4(A) 0.54 0.29 2.70〔0.150〕 1(P)→2(B) 0.54 0.30 2.70〔0.150〕 4(A)→5(R1) 0.57 0.08 2.85〔0.158〕 2(B)→3(R2) 0.54 0.09 2.70〔0.150〕 Notes: 1. Quick fitting TSH6-M5Ms are mounted on connection ports 1(P), 2(B), and 4(A). 2. Quick fitting TSH6-M5Ms are mounted on connection ports 2(B) and 4(A). 3. Figures in effective area S are calculated based on sonic conductance C (S=5.0×C). (Effective area S=3.0mm2〔Cv: 0.17〕) MPa 0.7 Valve outlet pressure 0.6 0.5 0.4 0.3 0.2 0.1 0 100 200 300 400 Flow rate R/min (ANR) 1MPa = 145psi., 1R/min = 0.0353ft3/min The graph uses flow rate calculations based on the discharge method. ● Use the flow rate as a guide. ● Port Size Port ( 2 B) ,( 4 A) ( 1 P) 3, ( 5 R) Direct piping M5×0.8 M5×0.8 M3×0.5 Base piping (with sub-base) M5×0.8 M5×0.8 M5×0.8 F type M5×0.8 Rc1/8 Rc1/8 A type M5×0.8 Rc1/8 Rc1/4 Port specification Single unit Manifold Mass Single Valve Unit Mass Basic model Mass g [oz.] Additional mass -21 (with bottom mounting base) -25 (with sub-base) JC10□F1 JC10□F2 26 [0.92] ― JC10□F5 26 [0.92] 4 [0.14] JC10□F6 40 [1.41] JC10□F3 JC10□F4 JC10□F7 JC10□F8 43 [1.52] ― ― JC10□F9 JC10□A1 JC10□A2 JC10□A3 26 [0.92] ― ― ― 27 [0.95] JC10□A4 JC10□A5 26 [0.92] JC10□A6 40 [1.41] JC10□A7 JC10□A8 43 [1.52] JC10□A9 Manifold Mass g [oz.] Basic model Mass calculation of each unit (n = number of units) JCM□F (12.5×n)+20 [(0.44×n)+0.71] JCM□A (22.5×n)+42 [(0.79×n)+1.48] Block-off plate With DIN rail mounting bracket 3 [0.11] ― 15 [0.53] Calculation example: JCM8A stn.1〜8 JC10A5-PS-D4 (22.5×8)+42+(26×8) = 430g [15.17oz.] Operating Principles and Symbols 5-port, 2-position Single solenoid Double solenoid 14(SA) 4(A) 2(B) 14(SA) 4(A) 2(B) 5(R1) 1(P) 3(R2) 12 5(R1) 1(P) 3(R2) 12(SB) JC10F5 JC10F6 De-energized 〔De-energized condition after energizing solenoid 12 (SB)〕 Column Plunger Major Parts and Materials Flapper Piston Solenoid 5(R1) Manual override 2(B) Synthetic rubber Flapper 3(R2) 4(A) Aluminum alloy (anodized) Lip seal 1(P) 5(R1) Materials Body Stem 4(A) Stem Parts Mounting base Mild steel (zinc plated) Valve 1(P) 2(B) 3(R2) Sub-base Aluminum alloy (anodized) Plunger Valve body Column Magnetic stainless steel End cover End cover Plastic Body Aluminum alloy (anodized) Lip seal Manifold Block-off plate Mild steel (nickel plated) Synthetic rubber Seal 5-port, 3-position 〔Both 14 (SA) and 12 (SB) are de-energized〕 Closed center 4(A) 2(B) JC10F7 Exhaust center 14(SA) 12(SB) 5(R1) 1(P) 3(R2) 4(A) 2(B) JC10F8 5(R1) 4(A) 12(SB) 1(P) 4(A) 2(B) JC10F9 12(SB) 5(R1) 4(A) 1(P) 2(B) 3(R2) 5(R1) 1(P) 3(R2) 5(R1) 4(A) 2(B) Pressure center 14(SA) 14(SA) 1(P) 2(B) 3(R2) 3(R2) 5(R1) 1(P) 3(R2) JC Series Single Valve Unit Order Codes ■ Sub-base ■ Manual override ■ Wiring specification Without sub-base Non-locking type S type plug connector Lead wire 300mm Blank Blank With sub-base Locking type Note4 -25 -81 -PS S type plug connector Lead wire 1000mm L type plug connector Lead wire 300mm -PL L type plug connector Lead wire 1000mm ■ Valve specification F1, A1: 2-port normally closed (NC)Note1 F2, A2: 2-port normally open (NO)Note1 -PS1 Note1 F3, A3: 3-port normally closed (NC) F4, A4: 3-port normally open (NO)Note1 S type plug connector Lead wire 3000mm -PL1 L type plug connector Lead wire 3000mm F5, A5: 5-port 2-position, single solenoid F6, A6: 5-port 2-position, double solenoid F7, A7: 3-position, closed center ■ Mounting base ■ Muffler Without mounting base Without muffler F8, A8: 3-position, exhaust center -PS3 -PL3 F9, A9: 3-position, pressure center S type plug connector Without connector ass’y Blank Blank With muffler for direct piping Note2 With mounting base ■ Model -PSN JC10 Standard type -21 With muffler for sub-base piping Note3 JC10L -D4 DC24V JC10S -D5 -GL Quick response type Model Valve specification Mounting base Sub-base Muffler Manual override F1Note1 F2Note1 F3Note1 F4Note1 JC10 JC10L JC10S F5 Blank Blank -21 -81Note4 Blank F6 F7 F8 F9 -75Note2 A1Note1 A2Note1 A3Note1 A4Note1 JC10 JC10L JC10S A5 A6 A7 A8 A9 Blank -81Note4 Blank Blank -25 -75Note3 Notes: 1. Valves with valve specifications F1, F2, F3, F4, A1, A2, A3, and A4 are for mounting on manifolds only, and cannot be used as single valve units. 2. The muffler thread for direct piping is M3×0.5 and the muffler cannot be used for sub-base piping. 3. When ordering the sub-base piping with muffler, always enter both -25 (sub-base) and -75 (muffler). The muffler thread for sub-base piping is M5×0.8 and the muffler cannot be used for direct piping. DC12V Note6 300mm = [11.8in.] 1000mm = [39in.] 3000mm = [118in.] -75 Base piping -PLN Grommet typeNote5 Lead wire 300mm ■ Voltage (moisture proof specification) -75 Low current type Direct piping L type plug connector Without connector ass’y Wiring specification Voltage -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote5 -D4 -D5Note6 -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote5 -D4 -D5Note6 4. The locking-type manual override is not available in the quick response type JC10S. 5. The grommet type is not available in the low current type JC10L and quick response type JC10S. 6. The DC12V specification is not available in the low current type JC10L and quick response type JC10S. JC Series Manifold Order Codes Left side ■ Manual override ■ Wiring specification Non-locking type S type plug connector Lead wire 300mm ■ Voltage L type plug connector Lead wire 300mm -D4 DC24V Left side -D5 Blank Right side Right side DC12VNote 4 -PS -PL Locking typeNote2 S type plug connector Lead wire 1000mm ■ Manifold specification ■ Mounting type F type (direct piping type) Direct mounting L type plug connector Lead wire 1000mm ■ Valve specification F1, A1: 2-port normally closed (NC) -81 F2, A2: 2-port normally open (NO) -PS1 F3, A3: 3-port normally closed (NC) F4, A4: 3-port normally open (NO) F Blank A type (base piping type) S type plug connector Lead wire 3000mm -PL1 L type plug connector Lead wire 3000mm F5, A5: 5-port 2-position, single solenoid With DIN rail mounting F6, A6: 5-port 2-position, double solenoid bracket (A type manifold only) F7, A7: 3-position, closed center F8, A8: 3-position, exhaust center -PS3 -PL3 F9, A9: 3-position, pressure center A S type plug connector Without connector ass’y -DN L type plug connector Without connector ass’y Mounting bracket is included. -PSN -PLN ■ Model Grommet typeNote 3 Lead wire 300mm (moisture proof specification) JC10 Standard type JC10L Low current type -GL JC10S 300mm = [11.8in.] 1000mm = [39in.] 3000mm = [118in.] Quick response type Model Number of units Manifold specification Mounting type Station Model Manifold model F type manifold (direct piping type) stn.1 ・ ・ ・ stn.□ JC10 JC10L JC10S Note1 A type manifold (base piping type) Manual override Wiring specification Voltage -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote3 -D4 -D5Note4 Mounting valve model F JCM Valve specification 2 ・ ・ ・ 20 F1 F2 F3 F4 F5 F6 F7 F8 F9 Blank -81Note2 JCBP (for block-off plate) A Blank -DN stn.1 ・ ・ ・ stn.□ Note1 JC10 JC10L JC10S A1 A2 A3 A4 A5 A6 A7 A8 A9 Blank -81Note2 -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote3 JCBP (for block-off plate) Notes: 1. The valve mounting location is from the left side of the manifold. 2. The locking-type manual override is not available in the quick response type JC10S. 3. The grommet type is not available in the low current type JC10L and quick response type JC10S. 4. The DC12V specification is not available in the low current type JC10L and quick response type JC10S. -D4 -D5Note4 JC Series Additional Parts Order Codes Block-off plate (block-off plate and 2 mounting screws) JCBP Common connector assembly EAZ - Connector-related EAZ Connector specification P : Connector, lead wire length 300mm [11.8in.] P1 : Connector, lead wire length 1000mm [39in.] P3 : Connector, lead wire length 3000mm [118in.] PN : Connector, without lead wire (contacts included) Connector specification PA :Positive common A type, connector, lead wire length 300mm [11.8in.] PA1 :Positive common A type, connector, lead wire length 1000mm [39in.] PA3 :Positive common A type, connector, lead wire length 3000mm [118in.] PB :Positive common B type, connector, lead wire length 300mm [11.8in.] PB1 :Positive common B type, connector, lead wire length 1000mm [39in.] PB3 :Positive common B type, connector, lead wire length 3000mm [118in.] PC :Positive common C type, connector, lead wire length 300mm [11.8in.] PC1 :Positive common C type, connector, lead wire length 1000mm [39in.] PC3 :Positive common C type, connector, lead wire length 3000mm [118in.] CPN :Positive common, connector, without lead wire (short bar and contacts included) A type: EAZ-PA□ ※ DIN rail mounting bracket (with screws) Black (−) Red (+) JCZ -DN B type: EAZ-PB□ ※ Red (+) (For common wiring) Black (−) C type: EAZ-PC□ ※ Red (+) (For common wiring) Black (−) Red (+) ※Lead wire length Blank:300mm [11.8in.] 1:1000mm [39in.] 3:3000mm [118in.] Application example A type B type B type B type B type C type Dimensions of JC Series Single Valve Unit (mm) 5-port, single solenoid JC10□F5-PL 30 (300) 10 22 2-φ2.1 (Mounting hole) For -75 Manual override 2-φ1.7 Counterbore φ3.2 Depth 1 (Mounting hole) 65.4 PR (Built-in muffler) 24.8 22.5 LED indicator 2-M3×0.5 2.8 12 2 (B) 9.3 13.1 3 (R2) 4 (A) 12.7 9.8 16.6 9 1 (P) φ6 17.6 8.4 8.4 5(R1) 7.6 3-M5×0.8 14 5-port, single solenoid (with sub-base) JC10□A5-25-PL (46.7) 16 (300) 10 30 11 22 5 14 Manual override 24.8 2-φ3.2 (Mounting hole) For -75 3 (R) 16.5 27 φ8 4-M5×0.8 3 1.1 2 (B) 12.3 33 1 (P) 65.4 4 (A) 20.7 PR (Built-in muffler) 2 (30.7) 8.1 22.5 LED indicator 5 17 11 20 14 34 Options ●Locking type manual override: -81 ●Grommet: -GL ●S type plug connector: -PS 19.6 (300) 24 LED indicator LED indicator 22 28 B (Overall length of valve) (300) 27.5 C 4- 14 22.5 18.5 24.8 22 3 5 1.2 2 (B) A (Overall length of valve) ●Mounting base: -21 2-φ3.5 (Mounting hole) mm Code A B JC10F5, JC10A5 65.4 70.4 JC10LF5, JC10LA5, JC10SF5, JC10SA5 − 70.4 Model Remark Overall length to the end of the valve Dimensions of JC Series Single Valve Unit (mm) 5-port, double solenoid JC10□F6-PL 12 30 (300) 10 22 14 24.8 22.5 LED indicator Manual override 2-PR (Built-in muffler) 2-φ1.7 Counterbore φ3.2 Depth 1 (Mounting hole) 3(R2) 4 (A) 9.8 9 φ6 95.6 For -75 1(P) 16.6 8.4 8.4 5(R1) 2 (B) 2-M3×0.5 2.8 42.9 2-φ2.1 (Mounting hole) 39.5 43.3 47.8 3-M5×0.8 7.6 5-port, double solenoid (with sub-base) JC10□A6-25-PL (46.7) (300) 34 16 30 20 11 22 17 14 2 10 24.8 For -75 16.5 33 1 (P) 2-PR (Built-in muffler) 4-M5×0.8 5 2-φ3.2 (Mounting hole) (30.7) 11 8.1 3 3 (R) φ8 27 95.6 12.3 2 (B) 20.7 4 (A) Manual override 31.3 LED indicator 22.5 5 14 Dimensions of JC Series Single Valve Unit (mm) 5-port, 3-position 12 30 JC10□F7-PL JC10□F8-PL JC10□F9-PL (300) 10 22 14 Manual override 24.8 22.5 LED indicator 2-PR (Built-in muffler) 2-φ1.7 Counterbore φ3.2 Depth 1 (Mounting hole) φ6 3(R2) 4 (A) 9.8 105.6 9 For -75 1(P) 16.6 8.4 8.4 5(R1) 2 (B) 3-M5×0.8 51.9 2-φ2.1 (Mounting hole) 48.5 52.3 56.8 2-M3×0.5 2.8 7.6 5-port, 3-position (with sub-base) (46.7) 16 (300) 34 20 30 11 22 17 14 2 10 LED indicator 24.8 22.5 5 14 Manual override 2-PR (Built-in muffler) 1 (P) 3 3 (R) 16.5 33 27 φ8 105.6 12.3 2 (B) 20.7 4 (A) 4-M5×0.8 40.3 5 For -75 8.1 JC10□A7-25-PL JC10□A8-25-PL JC10□A9-25-PL 11 2-φ3.2 (Mounting hole) (30.7) Options ●Locking type manual override: -81 ●Grommet: -GL ●S type plug connector: -PS 24 19.6 (300) 22 24.8 LED indicator Code A B JC10F6, JC10A6 95.6 105.6 JC10F7〜JC10F9, JC10A7〜JC10A9 105.6 115.6 − 105.6 − 115.6 Model JC10LF6, JC10LA6, JC10SF6, JC10SA6 JC10LF7〜JC10LF9, JC10LA7〜JC10LA9 JC10SF7〜JC10SF9, JC10SA7〜JC10SA9 Remark Overall length to the opposite end of the solenoid (300) B (Overall length of valve) 27.5 A (Overall length of valve) 22.5 18.5 LED indicator mm mm Dimensions of JC Series Manifold (mm) Manifold for combination mounting of 2, 3, 5-port valves JCM□F (46.7) (direct piping type) (300) L 14 30 22 9 LED indicator 10.5 (Pitch) Manual override M5×0.8 10 2-φ4.5 (Mounting hole) 24.8 PR (Built-in muffler) 3(R) 3(R) 4(A) 4(A) 2(B) 2(B) 2(B) 38 4(A) 1(P) 1(P) 30.3 9 39.3 0.1 2(B) 23 12.6 9.8 14.5 31 95.6 4(A) 105.6 65.4 4-Rc1/8 (both sides) 〔Installation example〕 4 JCM6F stn.1 JC10F3-PL-D4 stn.2 JC10F4-PL-D4 stn.3 JC10F5-PL-D4 stn.4 JC10F6-PL-D4 stn.5 JC10F7-PL-D4 stn.6 JCBP P stn.3 stn.4 stn.5 stn.6 14 stn.2 16 (30.7) stn.1 (4) Unit dimensions Number of units 2 L P 38.5 30.5 3 49.0 41.0 4 59.5 51.5 5 70.0 62.0 6 80.5 72.5 7 91.0 83.0 8 101.5 93.5 9 112.0 104.0 10 122.5 114.5 11 133.0 125.0 12 143.5 135.5 13 154.0 146.0 14 164.5 156.5 15 175.0 167.0 16 185.5 177.5 17 196.0 188.0 18 206.5 198.5 19 217.0 209.0 20 227.5 219.5 Dimensions of JC Series Manifold (mm) Manifold for combination mounting of 2, 3, 5-port valves JCM□A (300) 55.7 (base piping type) L 15 30 10 22 10.5(Pitch) 10 LED indicator PR (Built-in muffler) Manual override 2-φ4.5 (Mounting hole) 24.8 2-Rc1/4 (both sides) 65.4 2-Rc1/8 (both sides) 47 105.6 25 95.6 0.6 30.8 18 39.8 3.1 1(P) 17 35 3(R) 11 〔Installation example〕 5 JCM6A stn.1 JC10A3-PL-D4 stn.2 JC10A4-PL-D4 stn.3 JC10A5-PL-D4 stn.4 JC10A6-PL-D4 stn.5 JC10A7-PL-D4 stn.6 JCBP P stn.1 stn.2 stn.3 (5) stn.4 stn.5 stn.6 Plug 2(B) when mounting JC10※A1,※A3 4(A) 3.5 2.5 6.5 11 2(B) 25 (39.7) 14 2-M5×0.8 (per each station) Plug 4(A) when mounting JC10※A2,※A4 ●DIN rail mounting bracket (-DN) (7.3) 2 (48.6) 1(P) (5.2) 3(R) 24.5 Unit dimensions Number of units 2 L P 40.5 30.5 3 51.0 41.0 4 61.5 51.5 5 72.0 62.0 6 82.5 72.5 7 93.0 83.0 8 103.5 93.5 9 114.0 104.0 10 124.5 114.5 11 135.0 125.0 12 145.5 135.5 13 156.0 146.0 14 166.5 156.5 15 177.0 167.0 16 187.5 177.5 17 198.0 188.0 18 208.5 198.5 19 219.0 209.0 20 229.5 219.5 JE SERIES SPECIFICATIONS Specifications Basic Models and Functions JE12□F1Note JE12□F2Note JE12□F3Note JE12□F4Note JE12□A1Note JE12□A2Note JE12□A3Note JE12□A4Note Basic model For direct piping, F type manifolds For base piping, A type manifolds Item Number of positions JE12□F5 JE12□F6 JE12□F7 JE12□F8 JE12□F9 JE12□A5 JE12□A6 JE12□A7 JE12□A8 JE12□A9 3 positions 2 positions Number of ports 2, 3 ports Valve function Single solenoid NC, NO 5 ports Single solenoid Double solenoid Closed center, Exhaust center, Pressure center Remark: For the optional specifications and order codes, see p.253. Note: Valves with valve specifications F1, F2, F3, F4, A1, A2, A3, and A4 are for mounting on manifolds only, and cannot be used as single valve units. Specifications JE12□F1 JE12□F2 JE12□F3 JE12□F4 JE12□A1 JE12□A2 JE12□A3 JE12□A4 Basic model For direct piping, F type manifolds For base piping, A type manifolds Item JE12□F5 JE12□F6 JE12□F7 JE12□F8 JE12□F9 JE12□A5 JE12□A6 JE12□A7 JE12□A8 JE12□A9 Media Air Operation type Internal pilot type Flow rate characteristicsNote 1 Sonic conductance C dm 3/(s・bar) Base piping (A type): 1.9 Direct piping (F type): M5×0.8, Base piping (A type): Rc1/8 Port sizeNote 2 Lubrication Not required Operating pressure range MPa {kgf/cm2 }[psi.] Proof pressure 0.2〜0.7 {2〜7.1} [29〜102] MPa {kgf/cm2 }[psi.] Note 3 Response time ON/OFF ms Maximum operating Hz frequency 1.05 {10.7} [152] Standard type 12/28 or below 20 or below 12/30 or below Low current type (L) 12/60 or below 20 or below 12/60 or below Quick response type (S) 6/10 or below 8 or below 6/10 or below 50 ― Standard type 5 Low current type (L) 2 Quick response type (S) ms Minimum time to energize for self holdingNote 4 10 ― Operating temperature range (atmosphere and media) °C [°F] m/s2 {G} Shock resistance 5〜50 [41〜122] 1373.0 {140} (Axial direction 294.2 {30}) Mounting direction 1373.0 {140} (Axial direction 245.0 {25}) Any Notes: 1. For details, see the flow rate characteristics on p.250. 2. For details, see the port size on p.251. 3. Values when air pressure is 0.5MPa [73psi.]. The values for the 3-position valves are the switching time from the neutral position. 4. For double solenoid valve. Solenoid Specifications Rated voltage Item Operating voltage range DC24V (Standard type) DC24V (Low current type) DC24V (Quick response type) 10.8〜13.2 21.6〜26.4 21.6〜26.4 21.6〜26.4 (12±10%) (24±10%) (24±10%) (24±10%) ― Standard type Current (when rated voltage is applied) mA (r.m.s) 46 23 ― Power consumption W 0.55 0.55 ― ― Low current type Quick response type V DC12V (Standard type) Current (when rated Starting mA voltage is applied) Holding mA ― ― 23 125 46 Power consumption ― ― 6.3 Starting W ― ― 0.55 3 Holding W ― ― 0.15 1.1 Start-up time (standard time) ms ― ― 200 or below 30 or below Allowable leakage current mA 2 1 0.5 4 Insulation resistance MΩ Color of LED indicator Surge suppression (as standard) Over 100 (value at DC500V megger) Red Flywheel diode Flow Rate Characteristics The test method for flow rate characteristics conforms to JIS B 8390:2000 (test method for pneumatic equipment — equipment for compressible fluids — flow rate characteristics). ●When used as a single unit (with fittings) Basic model Direct piping Flow path Sonic conductance C dm3/(s・bar) Critical pressure ratio b Effective area S Note 5 mm2〔Cv〕 1(P)→ 4(A) 0.81 0.55 4.05〔0.225〕 JE12□F5 1(P)→ 2(B) 0.81 0.54 4.05〔0.225〕 JE12□F6 4(A)→ 5(R1) 0.75 0.44 3.75〔0.208〕 2(B)→ 3(R2) 0.76 0.43 3.80〔0.211〕 1(P)→ 4(A) 0.80 0.51 4.00〔0.222〕 1(P)→ 2(B) 0.80 0.52 4.00〔0.222〕 4(A)→ 5(R1) 0.71 0.41 3.55〔0.197〕 2(B)→ 3(R2) 0.72 0.43 3.60〔0.200〕 1(P)→ 4(A) 1.91 0.19 9.55〔0.531〕 JE12□A5 1(P)→ 2(B) 1.93 0.18 9.65〔0.536〕 JE12□A6 4(A)→ 5(R1) 1.90 0.15 9.50〔0.528〕 2(B)→ 3(R2) 1.90 0.12 9.50〔0.528〕 1(P)→ 4(A) 1.42 0.20 7.10〔0.394〕 1(P)→ 2(B) 1.49 0.21 7.45〔0.414〕 4(A)→ 5(R1) 1.37 0.18 6.85〔0.381〕 2(B)→ 3(R2) 1.28 0.14 6.40〔0.356〕 Flow path Sonic conductance C dm3/(s・bar) Critical pressure ratio b Effective area S Note 5 mm2〔Cv〕 Note 1 JE12□F7 JE12□F8 JE12□F9 Base piping Note 2 (with sub-base) JE12□A7 JE12□A8 JE12□A9 ●When mounted on a manifold (with fittings) Basic model F type manifold Note 3 (direct piping type) JE12□F1 JE12□F2 JE12□F3 JE12□F4 JE12□F5 JE12□F6 JE12□F7 JE12□F8 JE12□F9 A type manifold Note 4 (base piping type) JE12□A1 JE12□A2 JE12□A3 JE12□A4 JE12□A5 JE12□A6 JE12□A7 JE12□A8 JE12□A9 1(P)→4(A) 0.88 0.64 4.40〔0.244〕 1(P)→2(B) 0.88 0.63 4.40〔0.244〕 4(A)→5(R1) 0.90 0.20 4.50〔0.250〕 2(B)→3(R2) 0.91 0.20 4.55〔0.253〕 1(P)→4(A) 0.84 0.59 4.20〔0.233〕 1(P)→2(B) 0.85 0.59 4.25〔0.236〕 4(A)→5(R1) 0.85 0.20 4.25〔0.236〕 2(B)→3(R2) 0.85 0.21 4.25〔0.236〕 1(P)→4(A) 1.62 0.38 8.10〔0.450〕 1(P)→2(B) 1.63 0.38 8.15〔0.453〕 4(A)→5(R1) 1.82 0.10 9.10〔0.506〕 2(B)→3(R2) 1.77 0.18 8.85〔0.492〕 1(P)→4(A) 1.34 0.40 6.70〔0.372〕 1(P)→2(B) 1.37 0.24 6.85〔0.381〕 4(A)→5(R1) 1.34 0.08 6.70〔0.372〕 2(B)→3(R2) 1.26 0.17 6.30〔0.350〕 Notes: 1. Quick fitting TSH6-M5Ms are mounted on connection ports 1(P), 2(B), and 4(A). 2. Quick fitting TS8-01s are mounted on connection ports 1(P), 2(B), and 4(A). 3. Quick fitting TSH6-M5Ms are mounted on connection ports 2(B) and 4(A). 4. Quick fitting TS6-01Ms are mounted on connection ports 2(B) and 4(A). 5. Figures in effective area S are calculated based on sonic conductance C (S=5.0×C). MPa 0.7 MPa 0.7 0.6 0.6 Valve outlet pressure Direct piping type (Effective area S = 4.4mm2〔Cv: 0.25〕) Valve outlet pressure Base piping type (Effective area S = 9.5mm2〔Cv: 0.53〕) 0.5 0.4 0.3 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0 0 200 400 600 800 1000 Flow rate R/min (ANR) 100 200 300 400 500 Flow rate R/min (ANR) 1MPa = 145psi., 1R/min = 0.0353ft3/min Graphs use flow rate calculations based on the discharge method. ● Use the flow rate as a guide. ● 250 Port Size Port ( 2 B) ,( 4 A) ( 1 P) 3, ( 5 R) M5×0.8 M5×0.8 M5×0.8 Base piping (with sub-base) Rc1/8 Rc1/8 Rc1/8 F type M5×0.8 Rc1/8 Rc1/8 A type Rc1/8 Rc1/8 Rc1/8 Port specification Single unit Direct piping Manifold Mass Single Valve Unit Mass Basic model Mass g [oz.] Additional mass -21 (with bottom mounting base) -22 (with side mounting base) 39 [1.38] ― ― JE12□F5 36 [1.27] 6 [0.21] JE12□F6 52 [1.83] -25 (with sub-base) JE12□F1 JE12□F2 JE12□F3 JE12□F4 JE12□F7 JE12□F8 55 [1.94] ― 5 [0.18] ― JE12□F9 JE12□A1 JE12□A2 JE12□A3 39 [1.38] ― ― ― ― ― 48 [1.69] Block-off plate With DIN rail mounting bracket 7 [0.25] ― 15 [0.53] JE12□A4 JE12□A5 36 [1.27] JE12□A6 52 [1.83] JE12□A7 JE12□A8 55 [1.94] JE12□A9 Manifold Mass g [oz.] Basic model Mass calculation of each unit (n = number of units) JEM□F (13×n)+17 [(0.46×n)+0.60] JEM□A (32×n)+59 [(1.13×n)+2.08] Calculation example: JEM8A stn.1〜8 JE12A5-PS-D4 (32×8)+59+(36×8) = 603g [21.27oz.] Operating Principles and Symbols 5-port, 2-position Single solenoid Double solenoid 14(SA) 4(A) 2(B) 14(SA) 4(A) 2(B) 5(R1) 1(P) 3(R2) 12 5(R1) 1(P) 3(R2) 12(SB) JE12F5 JE12F6 De-energized 〔De-energized condition after energizing solenoid 12 (SB)〕 Column Plunger Major Parts and Materials Flapper Piston 5(R1) Solenoid Manual override Aluminum alloy (anodized) Lip seal 1(P) Flapper 2(B) 5(R1) Materials Body Stem 4(A) Stem Parts 3(R2) 4(A) Valve 1(P) 2(B) 3(R2) Lip seal Valve body End cover Synthetic rubber Mounting base Mild steel (nickel plated) Sub-base Aluminum alloy (anodized) Plunger Column Magnetic stainless steel End cover Plastic Body Aluminum alloy (anodized) Manifold Block-off plate Mild steel (nickel plated) Synthetic rubber Seal 5-port, 3-position 〔Both 14 (SA) and 12 (SB) are de-energized〕 Closed center 4(A) 2(B) JE12F7 Exhaust center 14(SA) 12(SB) 5(R1) 1(P) 3(R2) 4(A) 2(B) JE12F8 5(R1) 4(A) 12(SB) 1(P) 14(SA) 4(A) 2(B) JE12F9 12(SB) 5(R1) 4(A) 1(P) 2(B) 3(R2) 5(R1) 1(P) 3(R2) 5(R1) 4(A) 2(B) Pressure center 14(SA) 1(P) 2(B) 3(R2) 3(R2) 5(R1) 1(P) 3(R2) JE Series Single Valve Unit Order Codes ■ Mounting base Without mounting base Blank With mounting base (for bottom mounting) ■ Muffler ■ Manual override ■ Wiring specification Without muffler Non-locking type S type plug connector Lead wire 300mm Blank Blank -PS With muffler for direct pipingNote2 L type plug connector Lead wire 300mm -PL Locking type Note4 S type plug connector Lead wire 1000mm L type plug connector Lead wire 1000mm ■ Valve specification F1, A1: 2-port normally closed (NC)Note1 F2, A2: 2-port normally open (NO)Note1 F3, A3: 3-port normally closed (NC)Note1 -75 -81 With muffler for sub-base pipingNote3 Lever type (with erroneous operation prevention mechanism) -21 With mounting base (for side mounting) F4, A4: 3-port normally open (NO)Note1 S type plug connector Lead wire 3000mm F5, A5: 5-port 2-position, single solenoid F6, A6: 5-port 2-position, double solenoid F7, A7: 3-position, closed center F8, A8: 3-position, exhaust center -PS1 -22 -75 L type plug connector Lead wire 3000mm -84 Mounting base for side mounting is supplied with a valve. F9, A9: 3-position, pressure center -PL1 -PS3 ■ Sub-base S type plug connector Without connector ass’y Without sub-base -PSN Blank -PL3 L type plug connector Without connector ass’y -PLN ■ Model Grommet typeNote5 Lead wire 300mm ■ Voltage (moisture proof specification) With sub-base JE12 Standard type -D4 DC24V JE12L Low current type -25 -D5 -GL JE12S 300mm = [11.8in.] 1000mm = [39in.] 3000mm = [118in.] Quick response type Model Valve specification Mounting base Sub-base Muffler Manual override F1Note1 F2Note1 F3Note1 F4Note1 Direct piping JE12 JE12L JE12S F5 F6 F7 F8 F9 Blank Blank -21 -22 -81Note4 -84 Blank -75Note2 Blank -22 A1Note1 A2Note1 A3Note1 A4Note1 Base piping DC12VNote6 JE12 JE12L JE12S Blank A5 A6 A7 A8 A9 Blank Blank -25 -75Note3 Notes: 1. Valves with valve specifications F1, F2, F3, F4, A1, A2, A3, and A4 are for mounting on manifolds only, and cannot be used as single valve units. 2. The muffler thread for direct piping is M5×0.8 and the muffler cannot be used for sub-base piping. 3. When ordering the sub-base piping with muffler, always enter both -25 (sub-base) and -75 (muffler). The muffler thread for sub-base piping is Rc1/8 and the muffler cannot be used for direct piping. -81Note4 -84 Wiring specification Voltage -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote 5 -D4 -D5Note6 -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote5 -D4 -D5Note6 4. The locking-type manual override is not available in the quick response type JE12S. 5. The grommet type is not available in the low current type JE12L and quick response type JE12S. 6. The DC12V specification is not available in the low current type JE12L and quick response type JE12S. JE Series Manifold Order Codes ■ Manual override ■ Wiring specification Non-locking type S type plug connector Lead wire 300mm Left side Left side ■ Voltage L type plug connector Lead wire 300mm -D4 DC24V -D5 DC12VNote4 Blank Right side -PS Right side -PL Locking typeNote 2 S type plug connector Lead wire 1000mm ■ Manifold specification ■ Mounting type F type (direct piping type) Direct mounting ■ Valve specification F1, A1: 2-port normally closed (NC) F2, A2: 2-port normally open (NO) F3, A3: 3-port normally closed (NC) -81 Lever type (with erroneous operation prevention mechanism) F4, A4: 3-port normally open (NO) F Blank A type (base piping type) With DIN rail mounting bracket (A type manifold only) L type plug connector Lead wire 1000mm -PS1 S type plug connector Lead wire 3000mm F5, A5: 5-port 2-position, single sol. F6, A6: 5-port 2-position, double sol. -PL1 L type plug connector Lead wire 3000mm -84 F7, A7: 3-position, closed center F8, A8: 3-position, exhaust center -PS3 -PL3 F9, A9: 3-position, pressure center A S type plug connector Without connector ass’y -DN L type plug connector Without connector ass’y Mounting bracket is supplied with a manifold. -PSN -PLN ■ Model Grommet typeNote 3 Lead wire 300mm (moisture proof specification) JE12 Standard type 300mm = [11.8in.] 1000mm = [39in.] 3000mm = [118in.] JE12L Low current type -GL JE12S Quick response type Model Number of units Manifold specification Mounting type Station Model Manifold model F type manifold (direct piping type) stn.1 ・ ・ ・ stn.□ JE12 JE12L JE12S Note1 A type manifold (base piping type) Manual override Wiring specification Voltage -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote3 -D4 -D5Note4 Mounting valve model F JEM Valve specification 2 ・ ・ ・ 20 F1 F2 F3 F4 F5 F6 F7 F8 F9 Blank -81Note2 -84 JEBP (for block-off plate) A Blank -DN stn.1 ・ ・ ・ stn.□ Note1 JE12 JE12L JE12S A1 A2 A3 A4 A5 A6 A7 A8 A9 Blank -81Note2 -84 -PS -PS1 -PS3 -PSN -PL -PL1 -PL3 -PLN -GLNote3 -D4 -D5Note4 JEBP (for block-off plate) Notes: 1. The valve mounting location is from the left side of the manifold. 2. The locking-type manual override is not available in the quick response type JE12S. 3. The grommet type is not available in the low current type JE12L and quick response type JE12S. 4. The DC12V specification is not available in the low current type JE12L and quick response type JE12S. 254 JE Series Additional Parts Order Codes Block-off plate (block-off plate and 2 mounting screws) JEBP Common connector assembly EAZ - Connector-related EAZ Connector specification P : Connector, lead wire length 300mm [11.8in.] P1 : Connector, lead wire length 1000mm [39in.] P3 : Connector, lead wire length 3000mm [118in.] PN : Connector, without lead wire (contacts included) Connector specification PA :Positive common A type, connector, lead wire length 300mm [11.8in.] PA1 :Positive common A type, connector, lead wire length 1000mm [39in.] PA3 :Positive common A type, connector, lead wire length 3000mm [118in.] PB :Positive common B type, connector, lead wire length 300mm [11.8in.] PB1 :Positive common B type, connector, lead wire length 1000mm [39in.] PB3 :Positive common B type, connector, lead wire length 3000mm [118in.] PC :Positive common C type, connector, lead wire length 300mm [11.8in.] PC1 :Positive common C type, connector, lead wire length 1000mm [39in.] PC3 :Positive common C type, connector, lead wire length 3000mm [118in.] CPN :Positive common, connector, without lead wire (short bar and contacts included) A type: EAZ-PA□ ※ Black (−) Red (+) DIN rail mounting bracket (with screws) JEZ -DN B type: EAZ-PB□ ※ Red (+) (For common wiring) Black (−) C type: EAZ-PC□ ※ Red (+) (For common wiring) Black (−) Red (+) ※Lead wire length Blank:300mm [11.8in.] 1:1000mm [39in.] 3:3000mm [118in.] Application example A type B type B type B type B type C type Dimensions of JE Series Single Valve Unit (mm) 5-port, single solenoid 32 JE12□F5-PL (300) 12 10 24 2 LED indicator 14 Manual override PR (Built-in muffler) 2-φ2.15 Counterbore φ3.2 Depth 1 (Mounting hole) 24.8 22.5 2-φ3.5 (Mounting hole) 80 5-M5×0.8 17.4 12 2 (B) 2.8 14 15.8 18.7 3(R2) 18.5 1(P) 11.6 4 (A) For -75 φ8 24.5 11.6 11.6 5(R1) 2.2 2.2 9.4 18 5-port, single solenoid (with sub-base) JE12□A5-25-PL (300) (49.7) 12 10 32 24 2 14 LED indicator PR (Built-in muffler) 24.8 22.5 Manual override 8.5 8.5 80 5-Rc1/8 5(R1) 35 For -75 40 1 (P) 31.7 47 4 (A) 23.5 1 6 3(R2) 7 φ16 15.2 2 (B) 17 18 4 (35.7) 9.1 2-φ4.5 (Mounting hole) 28 (29) (57) Options (300) LED indicator 14.3 5 2.3 25 12 ●Lever type manual override: -84 2 (B) 24 LED indicator 2-φ3.5 (Mounting hole) KEEP ON PUSH 27.5 5 LOCK 3.6 Code A B JE12F5, JE12A5 80 85 JE12LF5, JE12LA5, JE12SF5, JE12SA5 − 85 Model Remark Overall length to the end of the valve (300) B (Overall length of valve) 24.8 12 30 ●S type plug connector: -PS 26 24 18.5 4- R4 18 4 (A) A (Overall length of valve) 1.2 21.6 12.4 12 ●Grommet: -GL 18.5 2-φ3.3 (Mounting hole) 2 (B) ●Locking type manual override: -81 22.5 ●Mounting base: -22 (for side mounting) 24.8 ●Mounting base: -21 mm Dimensions of JE Series Single Valve Unit (mm) 5-port, double solenoid JE12□F6-PL 32 (300) 12 10 24 LED indicator 14 Manual override 22.5 2 2-φ3.5 (Mounting hole) 2-φ2.15 Counterbore φ3.2 Depth 1 (Mounting hole) 24.8 2-PR (Built-in muffler) 5-M5×0.8 17.4 111 11.6 49.7 49.5 2.8 14 46.8 2 (B) 55.5 3(R2) 12 1(P) 4 (A) For -75 φ8 11.6 11.6 5(R1) 2.2 2.2 9.4 18 5-port, double solenoid (with sub-base) JE12□A6-25-PL (49.7) (300) 9 32 12 10 24 2 2-φ4.5 (Mounting hole) 14 LED indicator 2-PR (Built-in muffler) 8.5 24.8 22.5 Manual override 8.5 5-Rc1/8 5(R1) For -75 40 1 (P) 23.5 47 35 31.7 111 4 (A) 6 3(R2) 32 4 17 18 (35.7) 28 (29) (57) 7 φ16 15.2 2 (B) Dimensions of JE Series Single Valve Unit (mm) 32 5-port, 3-position 12 10 24 2 LED indicator 14 Manual override 2-φ3.5 (Mounting hole) 2-φ2.15 Counterbore φ3.2 Depth 1 (Mounting hole) 24.8 2-PR (Built-in muffler) 22.5 JE12□F7-PL JE12□F8-PL JE12□F9-PL (300) 5-M5×0.8 2 (B) 2.8 14 5-port, 3-position (with sub-base) JE12□A7-25-PL JE12□A8-25-PL JE12□A9-25-PL (49.7) 2.2 2.2 9.4 18 (300) 55.8 58.7 58.5 64.5 3(R2) 17.4 11.6 120 12 1(P) 4 (A) For -75 φ8 11.6 11.6 5(R1) 9 32 12 10 24 2 2-φ4.5 (Mounting hole) 14 LED indicator 2-PR (Built-in muffler) 24.8 22.5 Manual override 8.5 8.5 5-Rc1/8 5(R1) 40 23.5 35 47 For -75 1 (P) 6 3(R2) 7 φ16 2 (B) 15.2 31.7 120 4 (A) 41 4 17 28 18 (35.7) (29) (57) Options ●Locking type manual override: -81 ●Lever type manual override: -84 ●Mounting base: -22 (for side mounting) 12.4 LED indicator ON PUSH 5 LOCK 25 3.6 A (Overall length of valve) KEEP 22.5 18.5 2.3 4 (A) 12 (300) 24.8 12 21.6 14.3 24.8 2-φ3.3 (Mounting hole) ●Grommet: -GL ●S type plug connector: -PS 26 mm Code A B JE12F7〜JE12F9, JE12A7〜JE12A9 120 130 − 121 − 130 JE12SF7〜JE12SF9, JE12SA7〜JE12SA9 Remark 111 121 JE12LF6, JE12LA6, JE12SF6, JE12SA6 JE12LF7〜JE12LF9, JE12LA7〜JE12LA9 LED indicator Overall length to the opposite end of the solenoid 27.5 Model JE12F6, JE12A6 24 (300) B (Overall length of valve) 2 (B) Dimensions of JE Series Manifold (mm) Manifold for combination mounting of 2, 3, 5-port valves JEM□F (Direct piping type) (48.2) 32 PR (Built-in muffler) 24 (300) L LED indicator 15 Manual override 12.5 (Pitch) 9 4-φ4.5 (Mounting hole) 12 1 (P) 2 (B) 2 (B) 2 (B) 2 (B) 3 (R2) 3 (R2) 120 5 (R1) 4 (A) 17 4 (A) 46 4 (A) 1 (P) 1.5 32.5 2.2 2.2 41.5 8.5 4 (A) 14.5 11.6 5 (R1) 17.2 16.5 23 111 16.5 80 24.8 6-Rc1/8 (both sides) 〔Installation example〕 2.2 M5×0.8 4 2.2 P (4) 15.5 18 stn.1 stn.2 stn.3 stn.4 stn.5 stn.6 (34.2) JEM6F stn.1 JE12F3-PL-D4 stn.2 JE12F4-PL-D4 stn.3 JE12F5-PL-D4 stn.4 JE12F6-PL-D4 stn.5 JE12F7-PL-D4 stn.6 JEBP Unit dimensions Number of units 2 L P 42.5 34.5 3 55.0 47.0 4 67.5 59.5 5 80.0 72.0 6 92.5 84.5 7 105.0 97.0 8 117.5 109.5 9 130.0 122.0 10 142.5 134.5 11 155.0 147.0 12 167.5 159.5 13 180.0 172.0 14 192.5 184.5 15 205.0 197.0 16 217.5 209.5 17 230.0 222.0 18 242.5 234.5 19 255.0 247.0 20 267.5 259.5 Dimensions of JE Series Manifold (mm) Manifold for combination mounting of 2, 3, 5-port valves JEM□A (Base piping type) (300) (64.2) PR (Built-in muffler) L LED indicator 32 16 Manual override 24 10 12.5 (Pitch) 2-φ4.5 (Mounting hole) 12 49 21.5 120 111 24.5 36.5 27.5 14 3.5 3 (R2) 13.5 42.1 5 (R1) 1 (P) 29.5 80 83.5 24.8 6-Rc1/8 (both sides) 〔Installation example〕 JEM6A stn.1 JE12A3-PL-D4 stn.2 JE12A4-PL-D4 stn.3 JE12A5-PL-D4 stn.4 JE12A6-PL-D4 stn.5 JE12A7-PL-D4 stn.6 JEBP 5 P (5) stn.1 stn.2 stn.3 stn.4 stn.5 stn.6 2 (B) 12.5 31.5 (50.2) 18 Plug 2(B) when mounting JE12※A1,※A3 9 4 (A) Plug 4(A) when mounting JE12※A2,※A4 2-Rc1/8 (per each station) ●DIN rail mounting bracket (-DN) (7.3) 2 Unit dimensions 21 (8.7) 3 (R2) (48.6) 5 (R1) 1 (P) Number of units 2 L P 44.5 34.5 3 57.0 47.0 4 69.5 59.5 5 82.0 72.0 6 94.5 84.5 7 107.0 97.0 8 119.5 109.5 9 132.0 122.0 10 144.5 134.5 11 157.0 147.0 12 169.5 159.5 13 182.0 172.0 14 194.5 184.5 15 207.0 197.0 16 219.5 209.5 17 232.0 222.0 18 244.5 234.5 19 257.0 247.0 20 269.5 259.5 260 ">
Advertisement
Key features
- Air valve
- Compact
- Side mounting
- Single/Double solenoid
- 2, 3, 5 ports
- NC/NO
- Low-current
- Quick-response
- Manual override