Advertisement
Advertisement
BK-UV002 Ver.1.0 Air Valve SOLENOID VALVES PA PB SERIES INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Solenoid Internal circuit Method for Switching from Double to Single ● DC24V ●For the PA series ●For the PB series Rotate the end covers on the PA□ F6 and PA □ A6 models (2-position double solenoid valves) 180 degrees to use them as single solenoid valves (this change is not possible on 3-position valves). Note that the PA□ F5 and PA□ A5 models (2-position single solenoid valves) are designed specifically for use as single solenoid valves, and cannot be used as double solenoid valves. Change the switching pin on the PB□ C6 model (2-position double solenoid valve) to use as a single solenoid valve (this change is not possible on the 3-position valve). Note that the PB□ C5 model (2-position single solenoid valve) is designed specifically for use as a single solenoid valve, and cannot be used as a double solenoid valve. ●Single solenoid (Connector interior) Color of lead wire: Black 14 (SA) Color of lead wire: Red COM 14 (SA) (Red) ●Double solenoid (Connector interior) Color of lead wire: Black 14 (SA) 14 (SA) (Red) Color of lead wire: Red COM (Green) 12 (SB) Color of lead wire: White 12 (SB) Note:Since there is no polarity, the valve can be used for either +COM or −COM. Switching from double solenoid valves (at shipping) to single solenoid valves As shown in the illustration below, a D marked on the end cover on the model label surface side means that the unit is set for a double solenoid function. To convert to the single solenoid valve function, use a Phillips screwdriver to remove the end cover, rotate it 180 degrees, and set the mark to S. The recommended tightening torque for the end cover mounting screw is as shown below. ● AC100V, 200V (Connector interior) Color of lead wire: Black 14 (SA) Color of lead wire: Red COM As shown in the illustration below, use a Phillips screwdriver to remove the female thread block or plate of the unit’s front surface output port 4(A) and 2(B), then remove the end cover, remove the switching pin from the lower level hole and insert it in the upper level hole, to convert to the single solenoid function. The recommended mounting screw tightening torque for the end cover and the female thread block or plate are as shown below. Switching pin insert for double solenoid Model label ●Single solenoid Switching from double solenoid valves (at shipping) to single solenoid valves Switching pin insert for single solenoid Switching pin 14 (SA) (Red) ●Double solenoid (Connector interior) Color of lead wire: Black 14 (SA) 14 (SA) (Red) End cover Mounting screw Color of lead wire: Red COM End cover qEnd cover mounting screw (Green) 12 (SB) Female thread block (plate) wMounting screw Color of lead wire: White 12 (SB) Cautions: 1. Do not apply megger between the pins. 2. Leakage current inside the circuit could result in failure of the solenoid valve to return, or in other erratic operation. Always use it within the range of the allowable leakage current in electrical specifications listed on p.671, 685. If circuit conditions, etc. cause the current leakage to exceed the allowable leakage current, consult us. 3. For double solenoid valves, avoid energizing both solenoids simultaneously. End cover rotated 180 degrees D Double solenoid condition S Single solenoid condition Recommended tightening torque for mounting screws: 88.3N・cm {9.0kgf・cm} [7.8in・lbf] Cautions: 1. Do not remove the end cover except when switching between single and double solenoids. 2. When mounting the end cover, confirm that the gasket is attached before proceeding with the mounting. Recommended tightening torques for mounting screws q End cover mounting screw : 39.2N・cm {4.0kgf・cm} [3.5in・lbf] w Mounting screw : 137.3N・cm {14.0kgf・cm} [12.2in・lbf] Cautions: 1. Do not remove the end cover except when switching between the single and double solenoids. 2. When mounting the end cover and the female thread block or plate, confirm that the gasket is attached before proceeding with the mounting. DIN Connector Pilot air switching method (PB series only) Change the switching pins on the PB□ G and PB□ V models (external pilot positive pressure valves and vacuum valves) to use as an internal pilot positive pressure valve. Note that the PB□ model (internal pilot valve) is for internal pilot use only, and cannot be used as an external pilot positive pressure or vacuum valve. Switching from double solenoid valves (at shipping) to single solenoid valves As shown in the illustration below, use a Phillips screwdriver to remove the female thread block or plate of the unit’s top surface side outlet port 4(A) and 2(B), and then remove the switching pin from its position (lower level) for the external pilot specification and insert it in the position (upper level) for the internal pilot specification, to convert to the internal pilot specification. The recommended mounting screw tightening torque for the female thread block or plate is as shown below. Plate or female thread block Mounting screw Wiring instructions ●Installation Confirm the installation of the pilot valve gasket, and then firmly tighten the mounting screws to the recommended torque below. Lastly, firmly close the solenoid cover. Recommended tightening torque for mounting screws: 14.7N・cm {1.5kgf・cm} [1.3in・lbf] Manual override ●Manual override (for both locking and non-locking types) To lock the manual override, use a small screwdriver to open the manual override cover. In that position, press it all the way down and turn it 90 degrees in the clockwise direction to lock. When in the lock position, turning the manual override 90 degrees in the counterclockwise direction releases a spring on the manual override, returns it to the normal position, and releases the lock. When the manual override is not turned, this type acts just like the non-locking type. Pilot switching pin Manual override cover 12 B 14 A Manual override 14 (SA) side Switching pin insert for external pilot Terminal cover Terminal body Screwdriver (blade width of about 4mm [0.16in.]) Cover mounting screw Note Note: The appropriate tightening torque for the cover mounting screw is 29.4N・cm {3kgf・cm} [2.6in・lbf ]. Cable (Outer diameter 4〜7mm [0.16〜0.27in.]) Cable gland Screwdriver (blade width of about 3mm [0.12in.]) Terminal w Terminal body Terminal e Washer PUSH Switching pin insert for internal pilot Remove the cover mounting screw and lift the terminal cover off from the solenoid valve. Use a screwdriver, etc. to press hard against the head of the terminal body from the mounting hole of the terminal cover, and remove the terminal body. Pass a cable gland, washer, and cable gasket over the cable, insert it via the wiring outlet of the terminal cover, and connect lead wires to the terminal body (screwdriver blade width of about 3mm [0.12in.]). Cable gasket TURN Manual override 12 (SB) side Terminal q Terminal cover Lead wire Override operation portion Inner diameterφ3.5 [0.138in.] Depth 8 [0.31in.] Terminal e Terminal q Recommended tightening torque for mounting screws: 137.3N・cm {14.0kgf・cm} [12.2in・lbf] 〈 Terminal internal wiring connections〉 〉 Caution: When mounting the female thread block or plate, confirm that the gasket is attached before proceeding with the mounting. Pilot valve replacement ●Removal Hand-open the solenoid cover at q and use a small screwdriver to remove the mounting screws w mounting the pilot valve in place. Use pliers to hold and pull out the pilot valve’s flange e, and then remove the pilot valve. w Mounting screw e Terminal w Terminal body (solenoid side) Solenoid cover Pilot valve 14 (SA) side LED:Red q Pilot valve 12 (SB) side LED: Green Caution: The maximum height of the cover when open is 48mm [1.89in.] from the top surface. Ensure enough space for maintenance, etc. Cautions: 1. The PA/PB series valves are pilot type solenoid valves. As a result, the manual override cannot switch the main valve without air supplied from the 1(P) or X(P2) port. 2. Always release the lock of the manual overrides before commencing normal operation. 3. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. 4. Caution should be exercised to avoid rotating the manual override too far. It could damage the button. 5. If operating the solenoid valve’s manual override for maintenance, etc., check before restarting operations that the solenoid valve’s manual override has returned to the normal position, and that the main valve is in the required position for switching. 6. The maximum height of the cover when open is 8.4mm [0.331in.] from the top surface of the cover. Terminal No. Internal wiring connections q SOL.14 (SA) side w SOL.12 (SB) side e COM. Ground Caution: Because the cable has no polarity, it can be used for either +COM or −COM. Handling Instructions and Precautions Manifold Valve mounting and removal Port isolator (PB series settings only) ●For PA series Installation of a port isolator at port 1(P) between the stations of a split-type manifold isolates the air path between the station where the port isolator is installed and a station with a smaller stn. No. ●Port isolator for port 1(P) (Type: PB-SP) Can supply 2 different types of pressure. 2. Installation using a bottom-surface nut qInsert a hexagon nut into the manifold’s T groove. wUse a screw to tighten from the bottom of the mounting plate. Ensure that a suitable length screw is used, and mount it with particular attention for the tightening torque. In addition, use a washer if necessary to prevent looseness. 9 or less When removing the valve body from a sub-base or manifold, loosen the valve mounting screws (2 places), and lift in the direction of the arrow (see illustration below). To mount, follow the above procedure in reverse. The recommended tightening torque for the valve mounting screws is as shown below. Port isolator for port 1(P) PB-SP Gasket PA-GS1 Caution: For later installing of other port isolators, the manifold must be disassembled and then reassembled. See the disassembly diagram on p.669. Nameplate Recommended tightening torque for mounting screws: 176.5N・cm {18.0kgf・cm} [15.6in・lbf] ●For PB series When removing the valve, use a hexagonal bar wrench to loosen the valve mounting screws A and B by 2〜4 rotations. Move the mounting screw B (which includes screws on both sides, and a tie rod) in the direction of the arrow, move the valve until a gap of about 1mm opens up on each side of the valve, and then lift the valve in the direction of the large arrow. Be careful when loosening the mounting screws A and B, since the valve could fall at that time, for example, in an upside down manifold mounting. To assemble, follow the above procedure in reverse. The recommended tightening torque for the valve mounting screws is shown below. The nameplate is attached to the other side from that of the female thread block. For attaching or removing, flex it so that it fits the grooves on the upper and lower side of the plate, as shown in the illustration. Since the nameplate can be attached to either the top surface or front surface, make a careful selection to conform with the valve piping specifications that require combinations on the front and top surface piping. qHexagon nut (M5×0.8) Nut thickness 5mm or less wScrew (M5×0.8) 29.5 26 3. Installation using a DIN rail Insert into the grooves in the sequence of q and w below. Push in the direction of e, and align with the center of the DIN rail. rInsert a hexagon nut into the manifold’s T groove. tUse a screw to tighten from the top of the manifold. Always use a steel DIN rail. Do not use an aluminum rail, as it would not be sufficiently strong, causing deflection to loose products or dents in the rail that could lead to defects. Ensure that a suitable length screw is used, and mount it with particular attention for the tightening torque. In addition, use a double nut, etc., on the top surface of the manifold if necessary for the prevention of looseness. w Nameplate q Plate e tScrew (M5×0.8) 29.5 26 21 or more Female thread block Manifold installation methods Mounting screw B 1. Installation using a top-surface bolt Use a bolt to tighten from the top of the manifold. Care must be exercised when mounting to use a sufficiently long screw, and mount it with particular attention for the tightening torque. In addition, use a washer if necessary to prevent looseness. Screw (M5×0.8) Recommended tightening torque for mounting screws: 411.9N・cm {42.0kgf・cm} [36.5in・lbf] 26 29.5 42.5 Recommended tightening torque for mounting screws: 284.4N・cm {29.0kgf・cm} [25.2in・lbf] ●Precaution for installation of PA series manifolds (PAM□F, PAM□A, PAM□B) While the manifold has an M3 groove, be aware that this groove is not for use in manifold installation. Use this groove when binding lead wires, as a space for securing bands of binding wires. 1.5 24 Caution: Although the flow path for the PA and PB double solenoid specifications (F6, A6, C6) is set to the 1(P)→ 2(B) at shipping from the factory, conditions during shipping could cause the stem to move and the position to shift. When applying air to the system for the first time, confirm that it is safely set by running a preliminary check on switching, using electricity or manually. Beware that air could suddenly blow out from the OUT port. Nut thickness 4mm or less DIN rail (steel) 3.3 Mounting screw A rHexagon nut (M5×0.8) 5 3 5.6 ●Installing the PA series F type manifold (PAM□F) Dimensions of M3 nut groove (cannot be used for securing the manifold in place) Safe block Piping Individual air supply and exhaust spacer (Available in PB series only) Use an individual air supply and exhaust spacer when individually supplying and exhausting air for a certain 1 station on the same manifold. Installation of the individual air supply and exhaust spacer allows control from the spacer installation position of the air supply and exhaust to the next smaller stn. number valve. Note that a dedicated valve (PB24□Z-□-Z) is required when using this spacer, and take particular caution on product selection. When used in combination with a 3-position exhaust center valve on the same manifold, the safe block can ensure cylinder intermediate stop and hold its position for long periods without being affected by air leaks between the spool and valve body. In addition, when used in combination with a 2-position valve, the safe block can be used to prevent falls at the end of cylinder stroke when residual pressure on the supply side is exhausted. Wiring D-sub connector The D-sub connector can change the wiring outlet orientation between the top surface and side surface. During cylinder operation 4(A) Cylinder pressure (P2) 2(B) Insert from the back 〈Top surface outlet〉 〈Side surface outlet〉 4(A) 2(B) Air supply pressure(P1) During check valve operation 4(A) 2(B) Individual air supply and exhaust side spacer ●Port position for air supply and exhaust (individual air supply and exhaust spacer) 1. For front surface piping 3, 5(R) Exhaust port Cable specification 2(B) Cautions: 1. Set the cylinder load so that the pressure on the cylinder side 2(B) and 4(A) ports is less than double the supply side pressure and also does not exceed the allowable pressure range. 2. When exhausting residual pressure on the cylinder side, use a small screwdriver, etc., to push the residual pressure exhaust manual override, as shown in the diagram below. Caution should be exercised to guard against the possibility of workpieces falling or moving when the residual pressure is exhausted. 3. When a safe block is used in combination with a 3position closed center valve or pressure center valve, it does not ensure a cylinder’s intermediate stop and position holding, but prevents workpieces from falling. For top surface piping 2. For top surface piping 3, 5(R) Exhaust port 4(A) Air supply pressure(P1) For front surface piping In the case of cable specification, the shape of the cable ends is shown in the diagram below. φ3.9 [0.154in.] Red: COM Station No. Cable 3-leads of AWG24 White: 12 (SB) side solenoid (cannot be used with single solenoids) Black: 14 (SA) side solenoid Because the cable has no polarity, it can be used for either +COM or −COM. Residual pressure exhaust manual override 1(P) Air supply port 1. Single solenoid (C5 type) Connection polarity Positive Negative common common 12 P2 4A P 1 R2 3 2B 4A 2B 5 R1 1 P Safe block Color of lead wire − + Black + − Red Circuit diagram SA COM Internal circuit 1(P) Air supply port Recommended tightening torque for mounting screws: 58.8N・cm {6.0kgf・cm} [5.2in・lbf] Safe block Residual pressure exhaust manual override 2. Double solenoid (C6,C7,C8,C9 type) 4. To lock the residual pressure exhaust manual override, push the manual override all the way down and rotate it 90 degrees in the clockwise direction. When in the locked state, rotate the manual override 90 degrees in the counterclockwise direction; a spring returns the manual override to its normal position, and the lock is released. When the manual override is not turned, this type acts just like the non-locking type. 5. Always release the lock of the manual override before commencing normal operation. 6. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. 7. Caution should be exercised to avoid rotating the manual override too far. It could damage the button. 8. When the residual pressure exhaust manual override is operated for maintenance, etc., ensure that the manual override has returned to its normal position before restarting operations. Connection polarity Positive Negative common common Color of lead wire − + Black + − Red − + White Circuit diagram SA COM SB Internal circuit PB24□Z-□-Z Dedicated valve Cylinder pressure (P2) Pin No. (Terminal No.) and Corresponding Solenoids (for plug-in type) The examples below are for reference in showing the relationships between the pin No. (terminal No.) and the corresponding solenoids for the plug-in type manifold. All the examples of show cases in which maximum controlled solenoids are used. ●D-sub connector (25 pins) [Wiring specification D-sub connector (maximum number of control pins: 20)] Example 1 PBM12P-DUL stn. 1 2 3 4 5 6 stn.1〜4 PB24C5-T2-B-D4 stn.5〜11 PB24C6-T2-B-D4 stn.12 PB-BPMD 7 8 9 (Top View) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 10 11 12 Number of unit: 12 Single solenoid Example 2 Double solenoid PBM10P-DUL stn. 1 2 3 4 5 6 Wiring specification: -DUL Pin no. Wiring connection specification: Blank (packed wiring) Valve no. 1A 2A 3A 4A 5A 5B 6A 6B 7A 7B 8 9 2 3 4 5 6 7 8 9 10 11 12 13 Pin no. 14 15 16 17 18 19 20 21 22 23 24 25 Valve no. 8A 8B 9A 9B 10A 10B 11A 11B 12A 12B COM COM Block-off plate stn.1〜4 PB24C5-T2-B-D-D4 stn.5〜9 PB24C6-T2-B-D4 stn.10 PB-BPMD 7 1 (Top View) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 10 Number of unit: 10 Single solenoid Wiring specification: -DUL Pin no. Wiring connection specification: When all single solenoids are specified as -D (double wiring) Valve no. 1A 1B 2A 2B 3A 3B 4A 4B 5A 5B 1 2 3 4 5 6 7 8 9 10 11 12 13 Pin no. 14 15 16 17 18 19 20 21 22 23 24 25 Valve no. 6A 6B 7A 7B 8A 8B 9A 9B 10A 10B COM COM Double solenoid Block-off plate ●Terminal block box (21 terminals with M3 screw) [Wiring specification terminal block box (maximum number of control pins: 20)] Example 1 PBM13P-TL stn. 1 2 3 4 stn.1〜6 PB24C5-T2-B-D4 stn.7〜12 PB24C6-T2-B-D4 stn.13 PB-BPMD 5 6 7 8 9 (Top View) 3 1 10 11 12 13 5 4 2 7 6 9 8 11 13 15 17 19 COM 10 12 14 16 18 20 5 7 9 11 13 15 17 19 COM Number of unit: 13 Wiring specification: -TL Wiring connection specification: Blank (packed wiring) Single solenoid Pin no. 1 Valve no. 1A 3A 5A 7A 8A 9A 10A 11A 12A 13A COM 3 Pin no. 2 4 6 8 10 12 14 16 18 20 Valve no. 2A 4A 6A 7B 8B 9B 10B 11B 12B 13B Double solenoid Block-off plate Example 2 PBM10P-TL stn. 1 2 3 4 stn.1〜6 PB24C5-T2-B-D-D4 stn.7〜9 PB24C6-T2-B-D4 stn.10 PB-BPMD 5 6 7 8 9 (Top View) 3 1 2 10 5 4 7 6 9 8 11 13 15 17 19 COM 10 12 14 16 18 20 5 7 9 11 13 15 17 19 COM Number of unit: 10 Wiring specification: -TL Wiring connection specification: When all single solenoids are specified as -D (double wiring) Single solenoid Pin no. 1 Valve no. 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM 3 Pin no. 2 Valve no. 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 4 6 8 10 12 14 16 18 20 Block-off plate Double solenoid Notes: 1. The valve No.1A, 1B, 2A, 2B… numerals show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. numbers are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 3. When selecting the wiring connection specification -D for the single solenoid, the wiring base side of the specified station becomes a double solenoid wiring connection. Serial Transmission Manifold, Specifications General Specifications Voltage DC24V ±10% Operating temperature range 5〜50°C [41〜122°F] Vibration resistance 49.0m/s2 {5.0G} (Conforms to JIS C 0911) Shock resistance 98.1m/s2 {10.0G} (Conforms to JIS C0912) ●For details of specifications, see the user’s manuals (see below). Serial Transmission Block, Terminal Block (LED) Names ●For UNI-WIRE® System ●For Mitsubishi Electric MELSECNET/MINI-S3 ●For OMRON SYSBUS Wire System Transmission block specification: -01 (16 outputs), -02 (8 outputs) Transmission block specification: -11 Transmission block specification: -21 7 8 5 6 24V 0V 4 5 6 7 D 8 G SD 24V 0V RDA RD 4 G 3 1 2 3 4 5 6 0 1 E 5 6 D 2 9 OFF RDB 4 3 2 3 0 1 E 2 3 9 7 8 ×10 3 ON 1 T/R RUN ERR ADDRESS ×1 PWR RUN ERR POWER SEND Dip switch for various settings Rotary switch for station setting OFF ON ON SDA O N Address setting switch SDB TERM SG FG 24V + 0V E.C. MODE switch LED indicator LED indicator Description Indicator Description PWR •Lights up when power is turned on POWER •Lights up when power is turned on •Flashes during voltage drops or when over current (a short circuit) RUN •Lights up for normal data communication with master station SD •Flashes during sending data •Flashes during normal transmission •Lights up or shuts off during faulty transmission Remarks ※The UNI-WIRE® System is a serial parallel transmission system developed jointly by NKE and KURODA PRECISION INDUSTRIES. For details of the UNIWIRE System, see the NKE or KURODA PRECISION INDUSTRIES catalog, user’s manual, etc. ● Number of outputs per block 16 solenoids (transmission block specification: -01) 8 solenoids (transmission block specification: -02) ● Related materials: User’s manual, document No. HV017 FG 24V 0V End station setting switch LED indicator Indicator SEND − RD •Flashes during receiving data ERR •Lights up when data receiving error occurs, shuts off for normal communication Indicator Description • Lights up when transmission is normal, and the PC RUN is in operations mode or monitor mode •Flashes during normal transmission •Lights up during standby or faulty transmission •Shuts off during faults (during watchdog timer fault) T/R ERR Remarks ● Master station unit: SYSMAC-C (CV) series Remarks ● Master station: MELSEC-A series AJ71PT32-S3, AJ71T32-S3, A2CCPU/A2CJCPU, A1SJ71PT32-S3, link sub-stations up to a maximum of 64 stations, and link I/O numbers up to a maximum of 512. ※For details, see the Mitsubishi Electric’s sequencer MELSEC-A series catalog, user’s manual, etc. ● Number of outputs per block Maximum of 16 solenoids ※Since the block is equivalent to 2 stations, if substations are entirely composed of the blocks, the maximum becomes 32 units. C200H-RM201, C500-RM201 ※For details, see the OMRON’s programmable controller SYSMAC C(CV) series catalog, user’s manual, etc. ● Number of outputs per block Maximum of 16 solenoids ● Related materials: User’s manual, document No. HV019 ● Related materials: User’s manual, document No. HV018 ●For OMRON B7A Link Terminal ●For KOYO ELECTRONICS INDUSTRIES SA Bus Transmission block specification: -31 (standard type), -32 (high speed type) Transmission block specification: -41 (16 outputs), -42 (8 outputs) Output selector switch for faults Transmission block specification: -51 (16 outputs), -52 (8 outputs) Switch for address setting and output processing setting during error occurrence Station setting switch 1 2 3 4 5 6 7 8 POWER ERROR ON PWR ERR LOAD OFF ●For SUNX S-LINK POWER SEND ON HOLD 1 24V ERR SIG L+ 0V L- SHLD LED indicator LED indicator G L24V D 0V 2 3 24V 4 5 6 G 7 8 D 0V 24V LED indicator Indicator Description Indicator Description Indicator Description PWR •Lights up when power is turned on POWER •Lights up when power is turned on POWER •Lights up when power is turned on ERR •Lights up during faulty transmission ERROR •Lights up during faulty transmission or other faults SEND •Flashes during normal transmission •Lights up or shuts off during faulty transmission Remarks Remarks ● Connection method: 1 to 1 ※For details of the SA Bus system, see the KOYO ELECTRONICS INDUSTRIES catalog, user’s manual, etc. Remarks ● Number of outputs per block ● Number of outputs per block (Transmission block spec.) Standard type (-31) High speed type (-32) Transmission delay time Max.31ms Max.5ms Transmission distance Max.500m Max.100m ※For details of the B7A Link Terminal, see the OMRON catalog, user’s manual, etc. ● Number of outputs per block Maximum of 16 solenoids ● Error output specifications Output mode: NPN open collector Rated load voltage: DC24V Output current: Sink current MAX. 40mA ● Related materials: User’s manual, document No. HV020 ※For details of the S-LINK System, see the SUNX catalog, user’s manual, etc. 16 solenoids (transmission block specification: -41) 8 solenoids (transmission block specification: -42) 16 solenoids (transmission block specification: -51) 8 solenoids (transmission block specification: -52) ● Related materials: User’s manual, document No. ● Related materials: User’s manual, document No. HV021 HV022 ●For Mitsubishi Electric MELSEC I/O LINK Transmission block specification: -61 ●For Fuji Electric FA Components & Systems T Link Mini ●For KEYENCE KZ-R Transmission block specification: -81 Transmission block specification: -71 24V 0V POWER/ERROR 3 S2 SD FG 24V 0V S+ LED indicator RUN 7 8 9A Description Indicator Description PW •Lights up when power is turned on •Lights up when receiving data transmitted from master unit is normal PWR •Lights up when power is turned on ALM •Lights up during faulty transmission SD •Lights up during sending data to master unit RD •Lights up during receiving data from master unit ERR. •Lights up when faulty data transmitted from master unit ● 16 remote I/O unit connection stations, for a maximum of 128 inputs/outputs ※For details, see Mitsubishi Electric’s sequencer catalog, user’s manual, etc. 24V 0V Error retention switch Indicator Description POWER/ ERROR •Green: Lights up for normal communications state •Orange: Lights up when communications state is poor (can also light up when address settings are incorrect) •Red: Lights up during faulty operation, or when transmission is cut off Remarks ※For details of the T Link Mini, see the Fuji Electric FA Components & Systems catalog, user ’s manual, etc. ● Number of outputs per block Remarks FG LED indicator Indicator RUN 0 1 E S− ON/OFF switch for terminal resistance LED indicator 9 ERROR MODE HOLD CLEAR OFF S1 ADDRESS 0 1 E 7 8 7 8 5 6 FG 4 DG 9 2 3 ON RD 3 7 8 0 1 E 2 3 BCDE 9 2 3 DATA 3 3456 SD PWR ALM E 2 F01 5 6 3 4 ST. NO. RUN ERR. Address setting switch 5 6 PW Station setting switch ADDRESS ×10 ×1 4 Station setting switch Maximum of 16 solenoids ● Related materials: User’s manual, document No. HV024 Remarks ※For details of the KZ-R, see the KEYENCE catalog, user’s manual, etc. ● Number of outputs per block Maximum of 16 solenoids ※Since the block is equivalent to 4 stations, if substations are entirely composed of the blocks, a maximum of 4 units can be connected to 1 master unit. ● Number of outputs per block Maximum of 16 solenoids ● Related materials: User’s manual, document No. HV025 ● Related materials: User’s manual, document No. HV023 ●For OMRON CompoBus/S ●For Mitsubishi Electric CC-Link ●For OPCN-1 (former JPCN-1) Transmission block specification: -A1 (16 outputs), -A2 (8 outputs) Transmission block specification: -B1 Transmission block specification: -C1 3 O N 6 8 4 6 8 8 4 4 6 1 2 3 4 5 6 2 SD CLEAR 2 2 HOLD +24C +24V BDL BS− 24G FG +24V (FG) SLD DG DB Indicator PWR COMM ERR State Lights up Shuts off Lights up Shuts off Lights up Shuts off Indicator Description •During power supply PW •Lights up when power is turned on Green •Power not supplied L RUN •Lights up when normal data is received from master station Yellow Red Description •During normal communication •Communication fault, or standby SD •Lights up during sending data •Communication fault occurred RD •Lights up during receiving data •During normal communication, or standby Remarks ※For details about CompoBus/S, see the Omron catalog, user’s manual, etc. ● Number of outputs per block 16 solenoids (transmission block specification: -A1) 8 solenoids (transmission block specification: -A2) ● Related materials: User’s manual, document No. HV026 L ERR. •Lights up during transmission errors, and shuts off when time is over Lights up during station number setting error or transmission speed setting error Remarks ※For details of the CC-Link, see the Mitsubishi Electric catalog, user’s manual, etc. ● Number of outputs per block 16 solenoids (transmission block specification: -B1) ※Since the block occupies 1 station, if the block is entirely composed of remote I/O stations, a maximum of 64 units can connect to 1 master station. ● Related materials: User’s manual, document No. HV027 F01 E 2 1 H L ON 0V FG SG ALRM OFF +24V 0C B A Switch for setting terminal resistance (TERM) LED indicator LED indicator Color 3 DA HOLD/CLEAR switch LED indicator E RD +24C BS+ BDH F01 3456 0 3456 0 2 ×10 0 2 STATION NO. ×1 PW L RUN L ERR. BCDE B RATE PWR COMM ERR Station setting switch(STN) Transmission speed setting switch (RATE) Fuse PWR COMM BCDE Station setting switch 7 8 9A Transmission speed setting switch 7 8 9A Dip switch for various settings Indicator PWR COMM ALRM State Lights up Shuts off Lights up Shuts off Lights up Shuts off Color Green Green Red Description •Normal power •Abnormal power •Normal communications •Communication fault •Communication fault or setting fault •Normal Remarks ※For details of the OPCN-1, see JIS3511: 1999 (JEMF3008: 1999) Programmable Controller Field Network Standard (level 1). ● Specifications Compatibility class: TYPE-S52U Communication function: Initial setting service, input/output service, reset service Transmission speed (transmission distance is a reference value): 125kbps (1km), 250kbps (800m), 500kbps (480m), 1Mbps (240m) Number of outputs: 16 points/1 unit Station setting: 01H〜7FH (Number of connecting stations can reach to a maximum of 31 slave units for 1 master station) ● Related materials: User’s manual, document No. HV028 ■ For specifications and handling details, see the above-listed user’s manuals (document Nos. HV017〜HV029). Solenoid Valves PB Series Disassembly Diagram ●Non-plug-in type End block (right side) Gasket Connection rod for addition Gasket Connection rod End block (left side) Mounting screw 411.9N・cm {42.0kgf・cm} [36.5in・lbf ] ※Wiring-related parts are omitted. ●Plug-in type Serial transmission block Cover mounting screw 58.8N・cm {6.0kgf・cm} [5.2in・lbf] Gasket (for IP65 or equivalent) Terminal block box Wiring base assembly Gasket (for IP65 or equivalent) End block (right side) Gasket Connection rod for addition Gasket Connection rod End block (left side) Mounting screw 411.9N・cm {42.0kgf・cm} [36.5in・lbf] D-sub connector Wiring block mounting screw 78.5N・cm {8.0kgf・cm} [6.9in・lbf] ※Wiring-related parts are omitted. SOLENOID VALVES SERIES Specifications Basic Models and Valve Functions Basic model Item For direct piping, F type Manifold PA24□F5 PA24□F6 PA24□F7, PA24□F8, PA24□F9 For sub-base piping For A type and B type Manifolds PA24□A5 PA24□A6 PA24□A7, PA24□A8, PA24□A9 Number of positions 3 positions 2 positions Number of ports 5 Double solenoid Note Single solenoid Valve function Closed center, Exhaust center, Pressure center Remark: For the specifications and order codes, see p.675〜677. Note: 2-position double solenoid valve can be switched to a single solenoid valve. For details, see p.665. Specifications For direct piping Basic model For F type Manifold Item PA24□F5 PA24□F6 For sub-base piping PA24□A5 For A type and B type Manifolds PA24□A6 Media PA24□F7 PA24□F7G PA24□F8 PA24□F5G PA24□F6G PA24□F8G PA24□F5V PA24□F6V PA24□F7V PA24□F9 PA24□F9G PA24□A7 PA24□A7G PA24□A8 PA24□A5G PA24□A6G PA24□A8G PA24□A5V PA24□A6V PA24□A7V PA24□A9 PA24□A9G Air External pilot type (for positive pressure) Internal pilot type Operation type Effective area〔Cv〕Note1 Port size Note2 Rc1/4, 3/8 Lubrication Not required 0.2〜1.0MPa {2〜10.2kgf/cm2} [29〜145psi.] Main valve Operating pressure range External pilot Proof pressure Note4 Response time Note5 0〜1.0MPa {0〜10.2kgf/cm2} [0〜145psi.] 0.2MPa〜−100kPa {2kgf/cm2〜−750.1mmHg} [29psi.〜−29.53in.Hg] 0.2〜1.0MPa {2〜10.2kgf/cm2}Note3 [29〜145psi.] 0.2〜0.5MPa {2〜5.1kgf/cm2}Note7 [29〜73psi.] 1.5 {15.3} [218] MPa {kgf/cm2} [psi.] ON/OFF ms Maximum operating frequency Hz Minimum time to energize for self holding Note6 ms 45/25 25/30 25/35 45/25 25/35 45/25 50 50 25/30 25/35 50 5〜50 [41〜122] 1373 {140.0} 1373 {140.0} m/s2 {G} 25/30 5 Operating temperature range (Atmosphere or media) °C [°F] Shock resistance External pilot type (for vacuum) 25 〔1.4〕 , 36 〔2.0〕 mm2 Pilot valve axial direction 294.2 {30.0} 294.2 {30.0} Pilot valve axial direction 294.2 {30.0} Mounting direction 1373 {140.0} 294.2 {30.0} Pilot valve axial direction 294.2 {30.0} 294.2 {30.0} Any IP65 or equivalent (optional) Environmental protection Notes: 1. For details, see the effective area on p.672. 2. For details, see the port size on p.672. 3. When the main valve is 0.2〜1.0MPa [29〜145psi.], set the external pilot pressure to the same pressure as the main valve or larger, and at 1.0MPa [145psi.] or smaller. 4. The proof pressure is the pressure at which no damage, rupture, or external leaking can occur when maintained for 1 minute; it is not supposed to be used continuously. 5. The value when air pressure is at 0.5MPa [73psi.]. The 3-position shows the value when the valve is switched from the neutral position. A maximum of 5ms should be added to the response time for AC specifications, depending on the timing of the switching phase. 6. For a double solenoid 7. The recommended value. Can be used up to a maximum of 1.0MPa [145psi.]. Solenoid Specifications Item Rated voltage Operating voltage range V Rated frequency Hz DC24V Note AC200V Note AC100V Note 21.6〜26.4 90〜110 180〜220 (24±10%) (100±10%) (200±10%) 50 60 50 60 Current (when rated voltage is applied) mA(r.m.s) 42 11 6.5 Power consumption 1.0W 1.1VA 1.3VA 2.0 1.0 1.0 Allowable leakage current mA Insulation resistance MΩ Wiring type and lead wire length mm [in.] Color of lead wire Color of LED indicator Surge suppression (Standard equipment) Over 100 (value at DC500V megger) Grommet type, cabtyre cable (300 [11.8], 1000 [39], 3000 [118]), and DIN connectors Red (COM), Black (14SA side), White (12SB side) Red (14SA side), Green (12SB side) Bridge diode Notes: 1. Since AC-coils already have built-in bridge diodes, the starting current value is virtually identical to the energizing current value. 2. For long continuous energizing in AC-coils, consult us. 3. For both AC- and DC-coils, provide heat radiation measures to ensure that the ambient temperature (when used in a control box, the temperature inside the box) always remains within the specified temperature range. Safe Block Specifications Effective Area〔Cv〕 mm2 Valve port size Basic model -02 (Rc1/4) PA24HF5, PA24HF6 PA24HA5, PA24HA6 PA24HF7 PA24HA7 PA24HF8 PA24HA8 PA24HF9 PA24HA9 PA24F5, PA24F6, PA24F7 PA24F8, PA24F9 PA24A5, PA24A6, PA24A7 PA24A8, PA24A9 28 〔1.6〕 36 〔2.0〕 28 〔1.6〕 32 〔1.8〕 Effective area〔Cv〕 Basic model -03 (Rc3/8) PA24□-H Response time (ON/OFF) mm2 ms 22 〔1.2〕 40/40 ( 1 P) →4 (A) ,2 (B) 32 〔1.8〕 ( 4 A) ,2 (B) →5 (R1) ,3 (R2)36 〔2.0〕 ( 1 P) →4 (A) ,2 (B) 36 〔2.0〕 28 〔1.6〕 ( 4 A) ,2 (B) →5 (R1) ,3 (R2)32 〔1.8〕 28 〔1.6〕 22 〔1.2〕 25 〔1.4〕 Port Size ●Solenoid valves ●Sub-base piping specifications PR Basic model ( 1 P) PR X (P2) Rc1/4 M5×0.8 PA24□A□-02-25 Rc1/4 Rc1/4 Rc1/4 M5×0.8 M5×0.8 Rc1/4 M5×0.8 PA24□A□-03-25 Rc3/8 Rc3/8 Rc3/8 M5×0.8 M5×0.8 PA24□A□-04-25 Rc1/2 Rc1/2 Rc1/2 M5×0.8 M5×0.8 3 R2) ,( 5 R1) ( 4 A) ,( 2 B) ( Basic model ( 1 P) PA24□F□-02 Rc1/4 Rc1/4 PA24□F□-03 Rc3/8 Rc3/8 Remark: Set the tightening torque for the screws of the solenoid valve PR portion at 29.4N・cm {3kgf・cm} [2.6in・lbf] or less (only when -N is selected). Remark: The PR and X(P2) ports are available for the external pilot specifications (for positive pressure and vacuum) only. The pilot exhaust of internal pilot type is collected to 5(R1). ●Manifold Manifold model ( 1 P) PAM□F PAM□F-04 ( 4 A) ,( 2 B)( 3 R2) ,( 5 R1) ( 4 A) ,( 2 B) X(P2) PR ( 3 R2) ,( 5 R1) -02 -03 Rc3/8 (Rc1/4) (Rc3/8) Rc3/8 Rc1/2 (Rc1/4) (Rc3/8) Rc1/2 PAM□A Rc1/2 Rc1/4 Rc3/8 Rc1/2 Rc1/8 PAM□B Rc1/2 Rc1/4 Rc3/8 Rc1/2 Rc1/8 PAM□FG Rc3/8 (Rc1/4) (Rc3/8) Rc3/8 Rc1/8 Rc1/8 PAM□FG-04 Rc1/2 (Rc1/4) (Rc3/8) Rc1/2 Rc1/8 Rc1/8 PAM□AG Rc1/2 Rc1/4 Rc3/8 Rc1/2 Rc1/8 Rc1/8 PAM□BG Rc1/2 Rc1/4 Rc3/8 Rc1/2 Rc1/8 Rc1/8 Remark: The positions of the 4(A) and 2(B) piping ports ( ) are on the solenoid valve side. Remark: The pilot exhaust of PAM□F and PAM□F-04 is collected to 5(R1). Mass ●Direct piping specification, F type manifold specifications g [oz.] Note 1 Solenoid valve single unit (Port size) Basic model -02 (Rc1/4) Mass calculation of each unit -03 (Rc3/8) PA24□F7 PA24□F5 (n=number of units) PA24□F6 PA24□F8 PA24□F7 PA24□F5 PA24□F6 PA24□F8 PA24□F9 PAM□F (80×n)+90 PAM□F-04 (80×n)+270 [(2.82×n)+9.52] [(2.82×n)+3.17] 203 [7.16] 215 [7.58] Calculation example: PBM4F 〜 3 PA24F5-03-G1 D4 stn.1〜 stn.4 PA-BP (80×4) +90+ (197×3) +54=1055g [37.21oz.] 241 [8.50] Block-off plate PA-BP PA24□F9 197 [6.95] 209 [7.37] 235 [8.29] 54 [1.90] Notes: 1. For the wiring specification of DIN connector (-39), add 12g [0.42oz.] to the above, and for the cabtyre cable (-G3), add 3g [0.11oz.]. 2. The wiring specifications assume a lead wire length of 300mm [11.8in.]. 3. Plug R3/8: 14g [0.49in.], R1/2: 21g [0.74oz.] ●Sub-base piping specification, A type and B type manifold specifications g [oz.] Additional mass(n=number of units) Solenoid valve single unit Note1 Basic model Mass calculation of each unit PA24□A7 (n=number of units) PA24□A5 PA24□A6 PA24□A8 PA24□A9 PA24□A□ Port size specification Ported manifold -02 -03 Block-off Piping block -04 -B2 -B3 (Rc1/4) (Rc3/8) (Rc1/2) (Rc1/4) (Rc3/8) Safe block plate -H PA-BP 82 [2.89] 54 [1.90] 200 [7.05] 190 [6.70] 260 [9.17] PAM□A (200×n)+380 [(7.05×n)+13.40] 212 [7.48] 224 [7.90] 250 [8.82] 20×n [0.71×n] 10×n [0.35×n] 55×n [1.94×n] 46×n [1.62×n] PAM□B (200×n)+390 [(7.05×n)+13.76] 20×n [0.71×n] 10×n [0.35×n] 55×n [1.94×n] 46×n [1.62×n] Calculation example: PAM4A-B3 〜 3 PA24A5-G1 D4 stn.1〜 stn.4 PA-BP (200×4) +380+ (212×3) + (46×3) +54=2008g [70.83oz.] Notes: 1. For the wiring specification of DIN connector (-39), add 12g [0.42oz.] to the above, and for the cabtyre cable (-G3), add 3g [0.11oz.]. 2. The wiring specifications assume a lead wire length of 300mm [11.8in.]. 3. Plug R1/2: 21g [0.74oz.] Cylinder Operating Speed PA24HF5-03 PA24HA5-03-25 PA24F5-03 PA24A5-03-25 Measurement conditions 1200 1200 ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Piping inner diameter and length: φ7.5×1000mm [39in.] ●Fitting: Quick fitting (Model: NTS10-03) Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke: 300mm [11.8in.] 1000 φ50 φ63 800 600 400 φ80 φ100 200 φ125 φ140 10 20 30 40 50 60 Load ratio 70 Delay time Delay time φ50 φ63 800 600 400 φ80 φ100 200 φ125 φ140 0 10 20 30 40 50 60 Load ratio 70 % 1mm/s = 0.0394in./sec. Delay time s1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1000 % φ140 φ125 φ100 φ80 φ63 φ50 10 20 30 40 50 60 Load ratio Delay time 0 Maximum operating speed Maximum operating speed mm/s 1500 1400 Maximum operating speed Maximum operating speed mm/s 1500 1400 70 s1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 φ140 φ125 φ100 φ80 φ63 φ50 10 20 30 40 50 60 Load ratio % 70 % Flow Rate PA24 □ PA24H □ MPa 1.0 MPa 1.0 Supply pressure MPa Valve outlet pressure 0.8 0.9 0.7 0.7 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.1 0 0.8 1.0 0.8 0.6 0.2 0.1 500 1000 1500 2000 2500 3000 Flow rate R/min(ANR) How to read the graph When the supply pressure is 0.5MPa [73psi.] and the flow rate is 1220R/min [43.1ft.3/min.] (ANR), the valve outlet pressure becomes 0.4MPa [58psi.] Supply pressure MPa 0.9 Valve outlet pressure 0.9 0.7 0.9 0.6 0.7 0.5 0.6 0.5 0.4 0.4 0.3 0.3 0.2 0.1 0 1.0 0.8 0.2 0.1 1000 2000 3000 4000 5000 Flow rate R/min(ANR) 1MPa = 145psi. 1R/min = 0.0353ft.3/min. Operating Principles and Symbols 5-port, 2-position Single solenoid 14 (SA) ( 4 A) ( 2 B) Double solenoid 14 (SA) ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) ( 5 R1) ( 1 P) ( 3 R2) P2注1 12 (SB) PA24□F5 PA24□F6 Housing Cover Base Piston Adaptor Major parts and materials Valve body 5(R1) 4(A) Stem 1 (P) Materials Body Aluminum alloy (Anodized) Stem Aluminum alloy Cover 2(B) Valve Lip seal Parts 3(R2) Base Housing Plastic Adaptor ※Schematic diagram shows double solenoid (de-energizing Lip seal Synthetic rubber Piston Plastic Body Aluminum alloy (Anodized) Manifold Block-off plate Mild steel (Nickel-plated) condition after energizing solenoid 12(SB)). Seal Synthetic rubber 5-port, 3-position 〔Both solenoid 14(SA) and 12(SB) are de-energized.〕 Closed center 14 (SA) PA24□F7 (SA) Exhaust center 14 PA24□F8 ( 4 A) ( 2 B) P2注1 12 (SB) 4(A) 1 (P) 3(R2) 5(R1) 4(A) 1 (P) 2(B) 1 (P) 2(B) 3(R2) ( 5 R1) ( 1 P) ( 3 R2) P2注1 12 (SB) 5(R1) 4(A) 2(B) ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) P2注1 12 (SB) 5(R1) 14 (SA) PA24□F9 ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) Pressure center 3(R2) PA Series Manifold Order Codes Model q w e r t Number of units Manifold type Pilot specification Air supply and exhaust block Manifold outlet specification Manifold model F type manifold (Direct piping type) A type manifold (Side piping type) F PAM 2 ・ ・ ・ 16 A B type manifold (Bottom piping type) q Number of units K 2 3 2 units B Blank Blank G -04 G r Air supply and exhaust block size K G ※F type manifold only Blank Rc3/8 Rc1/2 w Manifold type K B B type manifold (Bottom piping type) ※See next page. stn.2 PA24□□-□-□-□…… -04 A type manifold (Side piping type) y Mounted valve K stn.1 PA24□□-□-□-□…… 16 16 units A stn.1 ・ ・ ・ stn.□ -02 -03 -B2 -B3 Blank 3 units F type manifold (Direct piping type) -02 -03 -B2 -B3 Blank ⁝ F y Mounted valve ⁝ ⁝ Note: For the stn. No., enter the valve specifications in the order of the required stations, or 1, 2, ..., from the left when the valve is viewed from the top. t K Manifold outlet specifications -02 Manifold thread port Rc1/4 -03 Manifold thread port Rc3/8 stn. 1 2 3 4 … ※When using a block-off plate to block, enter PA-BP. -B2 Piping block Rc1/4 -B3 Piping block Rc3/8 ※For A type and B type manifolds only e Pilot specification K Blank Internal pilot manifold G External pilot manifold Manifold Order Code Examples ●F type manifold (Direct piping type) 4 units DC24V ●A type manifold (Side piping type) 4 units DC24V PAM4F PAM4A-03 stn.1 PA24F5-02-G2-D4 stn.2 PA24F5-03-G2-D4 stn.3 PA24F6-03-G2-D4 stn.4 PA24F7-03-G2-D4 stn.1〜 2 PA24A5-G1-D4 stn.3 PA24A6-G1-D4 stn.4 PA24A7-G1-D4 PA Series Valve Order Codes (for valve single unit/manifold mounting) q w e r t y Model Valve specification Operation type Number of ports Piping size PR port -02 -03 Blank Blank -32 -33 -34 Blank F5 F6 F7 ● Valve single unit ● For F type manifold ●For Sub-base piping PA24 PA24H ●For A type manifold ●For B type manifold F8 F9 Blank A5 A6 A7 A8 A9 q Model K PA24 Standard type (Effective area 25mm2〔Cv: 1.4〕) (Effective area 36mm2〔Cv: 2.0〕) F6 F7 F8 F9 A5 A6 A7 A8 A9 Blank -02 -03 -04 -25 !1 !2 Environmental protection Voltage -39 -G1 -G2 -G3 Blank Blank -1L -3L -P -D4 -A1 -A2 i Wiring specification K Blank Internal pilot type -39 G External pilot type (for positive pressure) Note V External pilot type (for vacuum) Note DIN connector -G1 Grommet type straight connector -G2 Grommet type L connector -G3 Cabtyre Cable Blank Standard (5-port valve) 5-port double solenoid direct piping(single unit)/ for F type manifold 5-port 3-position ( 4 A) ( 2 B) closed center direct piping(single unit)/ for F type manifold ( 5 R1) ( 1 P) ( 3 R2) 5-port 3-position ( 4 A) ( 2 B) exhaust center Note direct piping(single unit)/ for F type manifold ( 5 R1) ( 1 P) ( 3 R2) 5-port 3-position ( 4 A) ( 2 B) pressure center Note direct piping(single unit)/ for F type manifold ( 5 R1) ( 1 P) ( 3 R2) -32 3-port valve (Rc1/4) Note -33 3-port valve (Rc3/8) Note -34 Note 3-port valve (Rc1/2) (Available for sub-base piping only) Note: When the 5-port valve used as a 3-port valve, plugs are supplied. t Piping size K ※Direct piping and sub-base piping only Blank Without sub-base 5-port 3-position ( 4 A) ( 2 B) exhaust center Note sub-base piping/ for A and B type manifolds ( 5 R1) ( 1 P) ( 3 R2) 5-port 3-position ( 4 A) ( 2 B) pressure center Note sub-base piping/ for A and B type manifolds ( 5 R1) ( 1 P) ( 3 R2) -1L -3L [11.8in.] Lead wire 1000mm [39in.] Lead wire 3000mm [118in.] Note: Available for wiring specifications -G1, -G2, and -G3 only. !0 Safe block K ※A type and B type manifolds only -03 Rc3/8 -H Rc1/2 y PR port K ( 5 R1) ( 1 P) ( 3 R2) Blank Lead wire 300mm Blank Without safe block (Available for sub-base piping only) 5-port 3-position ( 4 A) ( 2 B) closed center sub-base piping/ for A and B type manifolds ※Except DIN connector Rc1/4 -04 5-port double solenoid sub-base piping/ for A and B type manifolds o K Lead wire length -02 Note: For the direct piping type, the 3(R2) and 5(R1) ports become Rc1/4. 5-port single solenoid sub-base piping/ for A and B type manifolds Note: Not available for vacuum (V) !0 Safe block -H r Number of ports K 5-port single solenoid direct piping(single unit)/ for F type manifold o Lead wire length Blank Note: The single unit valve is not compatible with the external pilot type (for positive pressure, and for vacuum). For use as a single unit, select the sub-base piping specification. w Valve specification K i -N e Operation type K PA24H Large flow rate type F5 G V u Wiring Sub-base specification ※Direct piping (single unit) only Blank No threads -N With female threads (M5×0.8) u Sub-base K ※Sub-base piping only Blank Without sub-base (With 1 gasket, 2 mounting screws) With safe block Note Note: When ordering a manifold, the safe block is available provided the manifold outlet specifications are -B2 and -B3 (with piping block). The safe block cannot be used with external pilot types (for positive pressure and for vacuum). !1 Environmental protection K Blank Standard -P IP65 or equivalent Note: DIN connector (-39) is compatible with IP65 as the standard. !2 Voltage K -D4 DC24V -25 With sub-base -A1 AC100V -A2 AC200V Additional Parts Order Codes for PA Series Manifold Safe block Piping block (With 1 gasket, 2 mounting screws) Block-off plate Can be mounted at the same station where the valve is installed (with 2 mounting screws). PA -B2 Piping block Rc1/4 -B3 Piping block Rc3/8 PA-BP - F For F type manifold - A For A type manifold - B For B type manifold PA -H Replacement of pilot valve Pilot valves are available as replacements. The valves for 14 (SA) and 12 (SB) are distinguished from the LED color. The 14 (SA) LED is red, and the 12 (SB) LED is green. Select the required type (a gasket and 2 mounting screws are supplied). PA -D4 14 (SA) pilot valve, DC24V -A1 14 (SA) pilot valve, AC100V -A2 14 (SA) pilot valve, AC200V -D4B 12 (SB) pilot valve, DC24V -A1B 12 (SB) pilot valve, AC100V -A2B 12 (SB) pilot valve, AC200V Safe block Notes: 1. Safe blocks can be mounted only on A type or B type manifolds, and the manifold outlet specifications are -B2 or -B3. 2. The piping block is not included. (with 1 gasket) Gasket (for valve mounting) (With 2 mounting screws) PA -GS1 Gasket for F type manifold -GS2 Gasket for A type and B type manifolds and sub-base piping PA Series Dimensions of Single Valve Unit (mm) 20 (300) 43 17 1.5 8.4 1.4 23.8 Grommet type L connector 27.4 5(R1) 23 57 25 43 1(P) 3(R2) 2(B) 14 30.5 43 87 23 4(A) 135 Manual override cover When manual override cover is open 26 (Rc3/8) C 14A 21 PR port (internal pilot exhaust port) -N: M5×0.8 29 8 7.5 3 LED indicator Manual override 23 (Rc1/4) PA24□F5-G2 D S 2-Rc1/4 5.5 3-Rc3/8[Rc1/4] (Both sides) 37 3 18.6 2-φ4.2 counterboreφ7.6 Depth 3.5 (for manifold mounting) 26 D 15 S 2-φ5.4 counterboreφ9.4 Depth 6 Mounting hole 20 (300) 43 17 1.5 8.4 1.4 23.8 Grommet type L connector 27.4 5(R1) 23 57 25 43 1(P) 3(R2) 2(B) 14 30.5 43 87 23 4(A) 135 Manual override cover When manual override cover is open 26 (Rc3/8) 12B C 14A 21 PR port (internal pilot exhaust port) -N: M5×0.8 29 8 7.5 3 LED indicator Manual override 23 (Rc1/4) PA24□F6-G2 2-M4×0.7 Depth 5〜11 Mounting thread S D 2-Rc1/4 5.5 3-Rc3/8[Rc1/4] (Both sides) 37 3 18.6 2-φ4.2 counterboreφ7.6 Depth 3.5 (for manifold mounting) 26 2-φ5.4 counterboreφ9.4 Depth 6 Mounting hole S 15 D (300) 43 17 1.5 8.4 1.4 23.8 27.4 5(R1) 57 25 112 1(P) 68 2(B) 39 3(R2) 55.5 68 23 23 4(A) 2-Rc1/4 5.5 3-Rc3/8[Rc1/4] (Both sides) 37 26 18.6 2-φ4.2 counterboreφ7.6 Depth 3.5 (for manifold mounting) 15 2-φ5.4 counterboreφ9.4 Depth 6 Mounting hole For wiring specifications other than the grommet type L connector, see p.679. 2-M4×0.7 Depth 30〜36 Mounting thread 160 Manual override cover When manual override cover is open 26 (Rc3/8) 12B C 14A 29 PR port (internal pilot exhaust port) -N: M5×0.8 21 7.5 3 LED indicator Manual override 23 (Rc1/4) Grommet type L connector 20 8 PA24□F7-G2 PA24□F8-G2 PA24□F9-G2 2-M4×0.7 Depth 5〜11 Mounting thread PA Series Dimensions of Single Valve Unit (mm) PA24□A5-□-25 43 (300) Grommet type L connector 8.4 1.5 27.4 LED indicator Manual override 25 ( 3 R2) 14 11 6 29 2(B) 41.5 75 57 25 ( 1 P) 91 ( 5 R1) 4(A) 25 135 8 Manual override cover PR 20 M5×0.8 external pilot exhaust port (for external pilot specification) 17 1.4 21 23.8 10.6 2 S 13 5-Rc1/4(3/8) 2-φ5.4 Mounting hole 18.6 13 34 5 44 37 When manual override cover is open 24 (62) S D 17 P2 14 M5×0.8 external pilot air supply port (for external pilot specification) ●For Rc1/2 (common to all types) 17 M5×0.8 external pilot exhaust port (for external pilot specification) 8 15 28 6 28 17 5-Rc1/2 37 42 28 28 PR 20 25 32 (70) 25 M5×0.8 external pilot supply port (for external pilot specification) Wiring Specifications ●DIN connector: -39 34 10 12 49 153 1 7 mPm 17 135 135 1 56 9 27 φ14 φ7 18 43 (300) (300) 7.5 15.5 43 8 18 ●Cabtyre cable: -G3 135 ●Grommet type straight connector: -G1 PA24□A6-□-25 43 (300) 8.4 23.8 10.6 1.4 1.5 27.4 LED indicator Manual override 75 ( 3 R2) 14 11 6 29 ( 2 B) 41.5 25 57 25 (P) 1 91 ( 5 R1) ( 4 A) 25 135 8 Manual override cover PR 20 M5×0.8 external pilot exhaust port (for external pilot specification) 17 21 Grommet type L connector 2 D 13 5-Rc1/4(3/8) 2-φ5.4 Mounting hole 18.6 13 34 When manual override cover is open 5 44 37 24 (62) D S 17 P2 14 M5×0.8 external pilot air supply port (for external pilot specification) PA24□A7-□-25 PA24□A8-□-25 PA24□A9-□-25 43 (300) 1.5 LED indicator 8 Manual override PR 20 M5×0.8 external pilot exhaust port (for external pilot specification) 17 1.4 27.4 Grommet type L connector 8.4 10.6 21 23.8 Manual override cover 25 ( 3 R2) 27 39 11 6 29 ( 2 B) 41.5 25 160 75 57 25 (P) 1 91 ( 5 R1) ( 4 A) 5-Rc1/4(3/8) 13 18.6 2-φ5.4 Mounting hole 34 5 13 When manual override cover is open 37 24 (62) 44 17 P2 14 M5×0.8 external pilot air supply port (for external pilot specification) Wiring Specifications ●DIN connector: -39 7.5 10 12 153〔178〕 17 1 56 9 135〔160〕 1 mPm 7 φ14 φ7 18 43 27 (300) 135〔160〕 (300) 34 15.5 43 8 18 ●Cabtyre cable: -G3 135〔160〕 ●Grommet type straight connector: -G1 49 The figures in parentheses〔 〕are for the 3-position case. PA Series Dimensions of Manifold (mm) PAM□F Direct piping type 47 P (7) 〔 (10) 〕 PR 23 4(A) 4(A) 4(A) 5(R1) 43 ( 1 P) ( 1 P) 3(R2) P2 (25) 13.2 PR 4(A) 5(R1) 26 160 25.5 26 25.5 42.5 4-φ5.4 Mounting hole 2(B) S 2(B) S 2(B) 3(R2) 2(B) 91 8.2 Manual override cover 153 LED indicator 135 〔17〕 26 mPm 2-Rc1/8 pilot exhaust port [for external pilot specification] (with 1 plug) 24 26 (Pitch)〔29〕 29.5 (18) 24 10.5 13 6-Rc3/8 (with 3 plugs) Unit Dimensions L〔L1〕 〔10〕 7 19 P2 D 23.8 23.6 stn.1 stn.2 stn.3 stn.4 stn.5 ●Groove details PA24F6-03-39 PA24HF5-03-G2 3.3 PA24F7-02-G1 S S 37 62 〔L1〕 82 13 100 86 106 14 124 110 130 15 148 134 154 16 172 158 178 17 196 182 202 18 220 206 226 19 244 230 250 10 268 254 274 11 292 278 298 12 316 302 322 13 340 326 346 14 364 350 370 15 388 374 394 16 412 398 418 Note: The figures in parentheses〔 〕 are for the external pilot specification. 〔17〕 (62) 24 Groove for M5 nut (for manifold mounting) D 8.6 Groove for M3 nut (cannot be used to mount the manifold in place) 〔10〕 D 5.6 5 P 76 S 2 PA-BP Block-off plate L 12 2-Rc1/8 external pilot port 〔10〕 (for external pilot specification) (with 1 plug) D 3 5 5.5 1.5 8.1 PA24F5-02-G1 Number of units PAM□F-04 Direct piping type 48 4-φ5.4 Mounting hole PR 4(A) 5(R1) 46 1(P) ( 1 P) 3(R2) 2(B) (22) P2 S 19 2(B) S 2(B) 3(R2) 2(B) 94 4(A) 33 23 32 4(A) 29 4(A) 5(R1) 26 156 138 PR P2 D 23.8 23.6 19 stn.1 stn.2 stn.3 stn.4 stn.5 PA24F6-03-39 PA24HF5-03-G2 PA24F5-02-G1 PA24F7-02-G1 S PA-BP Block-off plate 〔29〕 〔18〕 1 27 Number of units L P 12 114 102 120 108 13 138 126 144 132 14 162 150 168 156 15 186 174 192 180 16 210 198 216 204 17 234 222 240 228 18 258 246 264 252 19 282 270 288 276 10 306 294 312 300 11 330 318 336 324 12 354 342 360 348 13 378 366 384 372 14 402 390 408 396 15 426 414 432 420 16 450 438 456 〔L1〕〔P1〕 444 Note: The figures in parentheses〔 〕are for the external pilot specification. 2-Rc1/8 external pilot port (for external pilot specification) (with 1 plug) D 〔29〕 D (63) S D 160 Manual override cover S 6-Rc3/8 (with 3 plugs) 32 (6) 24 45〔48〕 (Pitch) 〔29〕 LED indicator 〔18〕 45.5 24 91 mPm P〔P1〕 10.5 6 〔29〕 (18) 20 14 2-Rc1/8 pilot exhaust port [for external pilot specification] (with 1 plug) 14.5 Unit Dimensions L〔L1〕 PAM□A-0□ 83 Side piping type 2-Rc1/8 pilot exhaust port (with 1 plug) L 55 LED indicator 49 Manual override cover P 24 L P 2 87 60 3 111 84 4 135 108 5 159 132 6 183 156 7 207 180 8 231 204 9 255 228 10 279 252 11 303 276 12 327 300 13 351 324 38 14 375 348 46 15 399 372 53 16 423 396 (18) mPm 39.4 10.5 4-φ6.4 Mounting hole 154 95 160 52 (24) S 25.5 6 21 P2 13 30 3(R2) 10 136 16 30 5(R1) 44.5 PR 1(P) A→ 2-Rc1/8 external pilot port (for external pilot specification) (with 1 plug) Unit Dimensions (13.5) 24 31.5 (Pitch) Number of units 44.2 6-Rc1/2 (with 3 plugs) 43 13.5 S 23.8 23.6 Stn.1 Stn.2 Stn.3 Stn.4 PA24A5-G1 ●Viewed from A PAM□B-0□ (for bottom piping type) 2-Rc3/8(Rc1/4) Per each station PA24A6-39 PA-BP Block-off plate D 3 30 3.3 2(B) 4(A) 4(A) 6.5 2(B) 14.5 3 25 60 1.5 (98) 61 2(B) (95) 2(B) (13) 13 26.5 4(A) D 4(A) S 26 37 S PA24A7-G2 5.6 Dimensions of groove for M3 nut (2:1) (cannot be used to mount the manifold) 3 24 Note: The side piping type and bottom piping type cannot be selected on the same manifold. Select either piping type for the manifold. PAM□A-B□ 83 Side piping type 2-Rc1/8 pilot exhaust port (with 1 plug) L 55 LED indicator 49 Manual override cover P 24 (13.5) 24 31.5 (Pitch) L P 2 87 60 3 111 84 4 135 108 5 159 132 6 183 156 7 207 180 8 231 204 9 255 228 10 279 252 11 303 276 12 327 300 13 351 324 14 375 348 46 15 399 372 53 16 423 396 (18) mPm 4-φ6.4 Mounting hole 95 136 52 25.5 D 12 (24) S 6 21 P2 13 30 10 3(R2) 1(P) A→ 160 30 5(R1) 44.5 PR 154 16 10.5 6-Rc1/2 (with 3 plugs) 2-Rc1/8 external pilot port (for external pilot specification) (with 1 plug) Unit Dimensions Number of units 44.2 39.4 43 13.5 23.8 38 23.6 Stn.1 Stn.2 Stn.3 Stn.4 PA24A5-G1 ●Viewed from A PAM□B-B□ (for bottom piping type) PA24A6-39 S PA24A7-G2 PA-BP Block-off plate D 24 2(B) 4(A) 4(A) 60 (98) 61 2(B) 17.5 25 30.5 31.5 (13) 2(B) 25 2(B) D 4(A) S 4(A) (95) 37 2-Rc3/8(Rc1/4) Per each station Note: The side piping type and bottom piping type cannot be selected on the same manifold. Select either piping type for the manifold. PA Series Dimensions of Manifold with Safe Blocks (mm) PAM□A PAM□B Side piping type Bottom piping type 24 31.5 (Pitch) 79 136 195 3(R2) 1(P) A→ 5(R1) 136 PR 160 49 P2 42.3 S Residual pressure exhaust manual override Safe block 32.3 10 49 (98) (147) Safe block 7 Residual pressure exhaust manual override 23.8 For PA24□A7, A8, A9 (3-position) For PA24□A5, A6 (2-position) ●Viewed from A 37 S 60 4(A) 4(A) 4(A) 2(B) 2(B) 2(B) 4(A) Residual pressure exhaust manual override 7 (95) (98) D 2(B) SOLENOID VALVES SERIES Specifications Basic models and valve functions Basic model PB24□C7 PB24□C5 PB24□C6 PB24□C8 Item PB24□C9 Number of positions 3 positions 2 positions Number of ports 5 Double solenoid Note Single solenoid Valve function Closed center, Exhaust center, Pressure center Remark: For the specifications and order codes, see p.689〜692. Note: 2-position double solenoid valve can be switched to a single solenoid valve. For details, see p.665. Specifications Basic model PB24□C7G PB24□C7 PB24□C5 PB24□C6 Item PB24□C8 PB24□C5G PB24□C6G PB24□C8G PB24□C5V PB24□C6V PB24□C7V PB24□C9G PB24□C9 Air Media External pilot type (for positive pressure) Internal pilot type Operation type Effective area〔Cv〕Note1 Port size Note2 Rc1/4, 3/8 Lubrication Not required 0.2〜1.0MPa {2〜10.2kgf/cm2} [29〜145psi.] Main valve Operating pressure range External pilot Proof pressure Note4 0〜1.0MPa {0〜10.2kgf/cm2} [0〜145psi.] 0.2MPa〜−100kPa {2kgf/cm2〜−750.1mmHg} [29psi.〜−29.53in.Hg] 0.2〜1.0MPa {2〜10.2kgf/cm2}Note3 [29〜145psi.] 0.2〜0.5MPa {2〜5.1kgf/cm2}Note7 [29〜73psi.] 1.5 {15.3} [218] MPa {kgf/cm2} [psi.] Response time Note5 ON/OFF ms Maximum operating frequency Hz Minimum time to energize for self holding Note6 ms 40/25 25/25 35/45 40/25 35/45 40/25 50 50 25/25 35/45 50 5〜50 [41〜122] 1373 {140.0} 1373 {140.0} m/s2 {G} 25/25 5 Operating temperature range (Atmosphere or media) °C [°F] Shock resistance External pilot type (for vacuum) 25 〔1.4〕 , 36 〔2.0〕 mm2 Pilot valve axial direction 294.2 {30.0} 294.2 {30.0} Pilot valve axial direction 294.2 {30.0} Mounting direction 1373 {140.0} 294.2 {30.0} Pilot valve axial direction 294.2 {30.0} 294.2 {30.0} Any IP65 or equivalent (optional) available Environmental protection Notes: 1. For details, see the effective area on p.686. 2. For details, see the port size on p.686. 3. When the main valve is 0.2〜1.0MPa [29〜145psi.], set the external pilot pressure to the same pressure as the main valve or larger, and at 1.0MPa [145psi.] or smaller. 4. The proof pressure is the pressure at which no damage, rupture, or external leaking can occur when maintained for 1 minute; it is not supposed to be used continuously. 5. The value when air pressure is at 0.5MPa [73psi.]. The 3-position shows the value when the valve is switched from the neutral position. A maximum of 5ms should be added to the response time for AC specifications, depending on the timing of the switching phase. 6. For a double solenoid 7. The recommended value. Can be used up to a maximum of 1.0MPa [145psi.]. Solenoid Specifications Item Rated voltage Operating voltage range V Rated frequency Hz DC24V Note AC200V Note AC100V Note 21.6〜26.4 90〜110 180〜220 (24±10%) (100±10%) (200±10%) 50 60 50 60 Current (when rated voltage is applied) mA(r.m.s) 42 11 6.5 Power consumption 1.0W 1.1VA 1.3VA 2.0 1.0 1.0 Allowable leakage current mA Insulation resistance MΩ Wiring type and lead wire length mm [in.] Color of lead wire Color of LED indicator Surge suppression (Standard equipment) Over 100 (value at DC500V megger) Grommet type, cabtyre cable (300 [11.8], 1000 [39], 3000 [118]), and DIN connectors Red (COM), Black (14SA side), White (12SB side) Red (14SA side), Green (12SB side) Bridge diode Notes: 1. Since AC-coils already have built-in bridge diodes, the starting current value is virtually identical to the energizing current value. 2. For long continuous energizing in AC-coils, consult us. 3. For both AC- and DC-coils, provide heat radiation measures to ensure that the ambient temperature (when used in a control box, the temperature inside the box) always remains within the specified temperature range. Port Size Effective Area〔Cv〕 mm2 Valve port size Basic model -□1 (Rc1/8)-□2 (Rc1/4) PB24HC5 22 〔1.2〕 32 〔1.8〕 36 〔2.0〕 PB24HC7 22 〔1.2〕 28 〔1.6〕 32 〔1.8〕 PB24HC8 22 〔1.2〕 28 〔1.6〕 PB24HC9 22 〔1.2〕 28 〔1.6〕 PB24C5, PB24C6 PB24C7, PB24C8 PB24C9 18 〔1.0〕 22 〔1.2〕 PB24HC6 ( 4 A) ,( 2 B) ( 1 P) -□3 (Rc3/8) Rc1/2 ( 1 P) →4 (A) ,2 (B) -□1 -□2 -□3 Rc1/8 Rc1/4 Rc3/8 ( 3 R2) ,( 5 R1) X (P2) Rc1/2 Rc1/8 32 〔1.8〕 ( 4 A) ,2 (B) →5 (R1) ,3 (R2)36 〔2.0〕 ( 1 P) →4 (A) ,2 (B) 36 〔2.0〕 ( 4 A) ,2 (B) →5 (R1) ,3 (R2)32 〔1.8〕 25 〔1.4〕 Notes: 1. Caution should be exercised that the effective area is reduced by about 10% when using a front-surface piping block. 2. In the case of 2 or more valve units, the effective area could be reduced by about 5%, depending on the flow path. Safe Block Specifications Response time (ON/OFF) Effective area 〔Cv〕 Basic model PB24□-H mm2 ms 22 〔1.2〕 40/40 Mass ●Non-plug-in type manifold g [oz.] Basic mass Additional mass with options Mass calculation of each unit(n=number of units) wPort size qValve model Note1 PB24□C5 PB24□C6 268 [9.45] Additional mass PB24□C7 PB24□C8 PB24□C9 310 [10.93] -□1 -□2 -□3 (Rc1/8) (Rc1/4) (Rc3/8) 61 [2.15] 55 [1.94] 46 [1.62] (mass per 1 unit) Block-off plate -H PB-BPN -Z (Rc1/8) -Z (Rc1/4) -Z (Rc3/8) 82 [2.89] 152 [5.36] 180 [6.35] 176 [6.21] 168 [5.93] 450 [15.87] (q+w) ×n Calculation example: PBM5N 〜 5 PB24C5-T3-39-H-D4 stn.1〜 (268+12+46) ×5+450+ (82×5) =2490g [87.83oz.] Individual air supply and exhaust spacer Safe block Notes: 1. For the wiring specification of DIN connector (-39), add 12g [0.42oz.], and add 3g [0.11oz.] for the cabtyre cable (-G3). 2. The wiring specifications assume a lead wire length of 300mm [11.8in.]. 3. Plug R1/8: 3g [0.11oz.], R1/2: 21g [0.74oz.] ●Plug-in type and serial transmission type manifold g [oz.] Basic mass(n=number of units) Mass calculation of each unit qValve model PB24□C5 PB24□C6 wPort size PB24□C7 PB24□C8 PB24□C9 270 [9.52] 312 [11.01] -□1 -□2 -□3 Cable Note -U□ -E□ (q+w) ×n 55 [1.94] (mass per 1 unit) Wiring specification (Rc1/8) (Rc1/4) (Rc3/8) 61 [2.15] Additional mass with options Additional mass + 46 [1.62] (15×n) 585 [(0.53×n) + 20.63] Calculation example: PBM5P-TL 〜 5 PB24HC5-T3-B-D4 stn.1〜 (270+46) ×5+880=2460g [86.77oz.] Terminal block box D-sub -T□ -D□ S -H 880 [31.04] 765 [26.98] 960 [33.86] 82 [2.89] Serial Block-off Safe block transmission plate Individual air supply and exhaust side spacer -Z -Z -Z PB-BP□ (Rc1/8) (Rc1/4) (Rc3/8) 157 [5.54] 180 [6.35] 176 [6.21] Notes: 1. The cable specifications assume a cable length of 700mm [27.6in.]. 2. Plug R1/8: 3g [0.11oz.], R1/2: 21g [0.74oz.] 168 [5.93] Cylinder Operating Speed PB24HC5-□3 PB24C5-□3 Measurement conditions mm/s 1500 1400 1200 1200 ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Piping inner diameter and length: φ7.5×1000mm [39in.] ●Fitting: Quick fitting (Model: NTS10-03) Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke: 300mm [11.8in.] 1000 φ50 φ63 800 600 400 φ80 φ100 200 φ125 φ140 0 10 20 30 40 50 60 Delay time φ50 φ63 800 600 400 φ80 φ100 200 φ125 φ140 10 20 30 40 50 60 Load ratio % Delay time 70 % 1mm/s = 0.0394in./sec. Delay time s1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1000 0 70 Load ratio φ140 φ125 φ100 φ80 φ63 φ50 10 20 30 40 50 60 Delay time Maximum operating speed Maximum operating speed Maximum operating speed Maximum operating speed mm/s 1500 1400 70 Load ratio s1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 φ140 φ125 φ100 φ80 φ63 φ50 10 20 30 40 50 60 Load ratio % 70 % Flow Rate PB24 □ PB24H □ MPa 1.0 MPa 1.0 Supply pressure MPa Valve outlet pressure 0.8 0.9 0.7 0.7 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.1 0 0.8 1.0 0.8 0.6 0.2 0.1 500 1000 1500 2000 2500 3000 Flow rate R/min(ANR) How to read the graph When the supply pressure is 0.5MPa [73psi.] and the flow rate is 1220R/min [43.1ft.3 /min.] (ANR), the valve outlet pressure becomes 0.4MPa [58psi.] Supply pressure MPa 0.9 Valve outlet pressure 0.9 0.7 0.9 0.6 0.7 0.5 0.6 0.5 0.4 0.4 0.3 0.3 0.2 0.1 0 1.0 0.8 0.2 0.1 1000 2000 3000 4000 5000 Flow rate R/min(ANR) 1MPa = 145psi. 1R/min = 0.0353ft.3/min. Operating Principles and Symbols 5-port, 2-position Single solenoid 14 (SA) ( 4 A) ( 2 B) Double solenoid 14 (SA) ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) PB24□C5 ( 5 R1) ( 1 P) ( 3 R2) PB24□C6 P2注1 12 (SB) P2注1 Housing Cover Base Piston Exhaust valve Adaptor Valve body 5(R1) Stem 5(R1) Plate ( 1 P) Parts ( 1 P) Lip seal 3(R2) Major parts and materials 3(R2) Double & Single Switching pin Stem Aluminum alloy Base Plastic Housing Adaptor 2(B) 4(A) Aluminum die-casting Cover Female thread block 2(B) Materials Body Switching pin 4(A) 〔De-energized〕 〔De-energizing condition after energizing solenoid 12 (SB)〕 Lip seal Synthetic rubber Piston Plastic Exhaust valve Synthetic rubber 5-port, 3-position 〔Both solenoid 14 (SA) and 12 (SB) are de-energized.〕 Closed center 14 (SA) PB24□C7 (SA) Exhaust center 14 PB24□C8 ( 4 A) ( 2 B) PB24□C9 ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) P2注1 12 (SB) ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) 5(R1) 5(R1) ( 1 P) ( 1 P) ( 1 P) 3(R2) 3(R2) 3(R2) 4(A) 2(B) 4(A) ( 5 R1) ( 1 P) ( 3 R2) P2注1 12 (SB) P2注1 12 (SB) 5(R1) 2(B) Pressure center 14 (SA) 2(B) 4(A) PB Series Manifold Order Codes q Number of units Model w Manifold type e r Wiring specification Transmission block specification t y Wiring position Environmental protection (transmission block) Manifold model Non-plug-in type N Plug-in type 1 ・ ・ ・ 16 PBM Serial transmission type P Blank -P -01 -02 -11 -21 -31 -32 r K -41 -42 -51 -52 -61 -71 -81 -A1 -A2 -B1 -C1 -D1 Transmission block specification ※Serial transmission type only 1 unit Note: The maximum number of units that 2 units ⁝ 16 16 units can be controlled varies according to the number of solenoids. For details, see p.693. When used with an individual air supply and exhaust spacer, the number of valve units and the number of individual air supply/exhaust spacers determines the total number of units. For details, see the order code examples on p.691. w Manifold type K N -UL -DUL -TL -UR -DUR -TR -EL -DEL -ER -DER S q Number of units K 1 2 u Mounted valve P Plug-in type S Serial transmission type -01 For UNI-WIRE System (16 outputs) -02 For UNI-WIRE System (8 outputs) -11 For Mitsubishi Electric MELSECNET/MINI-S3 (maximum of 12 units) -UR Cable outlet at top surface on right (maximum of 12 units) -EL Cable outlet at side surface on left -ER Cable outlet at side surface on right IP 65 or equivalent Note Note: Plug-in type can be set for terminal block box specifications only. The non-plug-in type is compatible with IP65 or equivalent as standard. Both types require selection of -P for the valve side. u Mounted valve K -32 For OMRON B7A Link Terminal (High speed) ※See next page. -41 For KOYO ELECTRONICS INDUSTRIES SA Bus (16 outputs) stn.1 PB24□□-□-□-□…… -42 For KOYO ELECTRONICS INDUSTRIES SA Bus (8 outputs) stn.2 PB24□□-□-□-□…… -61 For Mitsubishi Electric MELSEC I/O LINK -UL Cable outlet at top surface on left Environmental protection ※Plug-in type/Serial transmission type -31 For OMRON B7A Link Terminal (Standard) -51 For SUNX S-LINK (16 outputs) ※Plug-in type only -P y K -P -52 For SUNX S-LINK (8 outputs) e Wiring specification K Blank -R Blank Standard -21 For OMRON SYSBUS Wire System Non-plug-in type Blank stn.1 ・ ・ ・ stn.□ ⁝ For the stn. number, enter the valve ⁝ Note: specifications for the required stations, numbering them 1,2,... from the left, as viewed with the solenoid on top. stn. 1 2 3 4 … -71 For Fuji Electric FA Components & Systems T Link Mini -81 For KEYENCE KZ-R ※For the block-off plate, see p.691. -A1 For OMRON CompoBus/S (16 outputs) -A2 For OMRON CompoBus/S (8 outputs) -B1 For Mitsubishi Electric CC-Link -C1 For OPCN-1 (former JPCN-1) -D1 For DeviceNet (CompoBus/D) Note: For details, see p.695〜697. -DUL D-sub connector at top surface on left side mounting Note -DUR D-sub connector at top surface on right side mounting Note t Wiring position K ※Serial transmission type only Blank Left-side mounting -DEL D-sub connector at side surface on left side mounting Note -DER D-sub connector at side surface on right side mounting Note -TL Terminal block box on left side mounting Note -TR Terminal block box on right side mounting Note Note: For pin (terminal) locations, see p.693. -R Right-side mounting Manifold Order Code Example ●Serial transmission type, 4 units, DC24V PBM4S-B1-P stn.1 PB24C5-T2-B-P-D4 stn.2 PB24C5-D-T3-B-P-D4 stn.3 PB24C6-T3-B-P-D4 stn.4 PB24C7-T3-B-P-D4 PB Series Mounted Valve Order Codes (cannot be used as a single valve unit) q Model w e Valve Operation type specification r Number of ports i o !2 !3 Lead wire length Safe block Individual air supply and exhaust spacer !1 Piping Wiring Wiring connection specification specification specification t Port isolator Environmental protection Voltage -39 -G1 -G2 -G3 Blank Blank Blank Blank Blank -H -Z -SP -P ●Non-plug-in type ●Plug-in type (cable specification) C5 C6 C7 C8 C9 PB24 PB24H ●Plug-in type Blank G V Z GZ VZ Blank -31 -32 -33 (D-sub connector, terminal block box) ●Serial transmission type -T1 -T2 -T3 -U1 -U2 -U3 y u !0 -1L -3L Blank -D Blank -1L -3L -D4 -A1 -A2 Blank -B -D ●Various types of block-off plates are available as options. For details, see p.691. q Model K t Piping specification K PB24 -T1 Front surface piping Rc1/8 Blank Without safe block -T2 Front surface piping Rc1/4 -H -T3 Front surface piping Rc3/8 Note: Cannot be used with external pilot types (for positive pressure and for vacuum). Standard type (Effective area 25mm2〔Cv: 1.4〕) PB24H Large flow rate type 2 (Effective area 36mm〔Cv: 2.0〕) w Valve specification K C5 5-port single solenoid C6 5-port double solenoid -U1 Top surface piping Rc1/8 -U2 Top surface piping Rc1/4 -U3 Top surface piping Rc3/8 y Wiring specification K C7 5-port 3-position closed center ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) C8 5-port 3-position exhaust centerNote ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) C9 5-port 3-position pressure centerNote ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) Note: Not available for vacuum (V) -39 DIN connector -G1 Grommet type straight connector V External pilot type (for vacuum) Z Internal pilot type with individual air supply and exhaust spacer Note GZ External pilot type with individual air supply and exhaust spacer (for positive pressure) Note VZ External pilot type with individual air supply and exhaust spacer (for vacuum) Note Note: Dedicated valves for use with individual air supply and exhaust spacers. Note: For details, see the order code examples on p.691. r Number of ports K -B ※Plug-in type/serial transmission type -32 Note 3-port valve (Rc1/4) -33 3-port valve (Rc3/8)Note Note: When the 5-port valve is used as a 3-port valve, plugs are supplied. !1 Port isolator K With port isolator for P port Note: Port isolator can be mounted in only 1 location (1 station) in the manifold. Port isolator is installed between the specified station and the station to its immediate left (the smaller stn. no.) at shipping. !2 Environmental protection K Blank Standard Blank Packed wiring: Wiring connection with each mounted valve. -D Double wiring: Provides wiring connections for a double solenoid even when the specification is for a single solenoid. i Lead wire length K ※Except DIN-type connector Blank Lead wire 300mm 3-port valve (Rc1/8)Note Note: Always enter -Z when selecting dedicated valves for the manifolds. For details, see the order code examples on p.691. -SP Always enter -B for D-sub connector, terminal block box and serial transmission types. u Wiring connection spec. K Blank Standard (5-port valve) -31 With individual air supply and exhaust spacer Note -G2 Grommet type -G3 Cabtyre cable External pilot type (for positive pressure) Blank Without individual air supply and exhaust spacer Blank Without port isolator Blank Internal pilot type G With safe block Note !0 Individual air supply and exhaust spacer K -Z ※No cable specification entry L connector e Operation type K o Safe block K -1L -3L [11.8in.] (700mm [27.6in.]) Lead wire 1000mm [39in.] (1500mm [59in.]) Lead wire 3000mm [118in.] (3000mm [118in.]) Note: Not available in wiring specification -39. The figures within parentheses ( ) are for plug-in type cable specification. The cable length shows the distance from each valve. -P IP65 or equivalent Note Note: The DIN connector (-39) is compatible with IP65 or equivalent as standard. In the case where the IP65 or equivalent is used, select -P for both the manifold order code and the valve order code. !3 Voltage K -D4 DC24V -A1 AC100V Note -A2 AC200V Note Note: Not available in serial transmission type. Order code examples when using the individual air supply and exhaust spacer Not functional as an individual air supply and exhaust spacer alone. It works when used in combination with the dedicated valve (PB24 □ Z). Since the spacer is added as part of the total number of valve units, take consideration of the maximum number of units allowed in the manifold. In the mounting case at right, the station configuration is stn.1〜stn.3., but the number of units in the manifold is counted as 4 units. For the air supply and exhaust port positions, see p.668. 〈Mounting example〉 PB24C6Z-T3-Z-D4 (Dedicated valve) Individual air supply and exhaust spacer Note: Occupies 1 station space on the right side of the dedicated valve. Order Code Example ●Plug-in type cable specification 4 units DC24V Num stn.1 ber stn.2 1 of un stn.3 its 2 3 4 PBM4P-EL stn.1 PB24C5-T2-D4 stn.2 PB24C5-T3-D4 stn.3 PB24C6Z-T3-Z-D4 PB Series Manifold Options Order Codes Block-off plate PB-BP q w e Non-plug-in type When valves are expected to be installed in the future, use these as mounted on a manifold. Note that this configuration is different from the conventional plate type block-off plates, and it is the block shape. For instructions for mounting and removal, see the valve mounting and removal on p.667. For D-sub connector, terminal block box, serial transmission type 〈Mounting example〉 qSpecification N M K K1 K3 Cable specification (700mm [27.6in.]) Cable specification (1500mm [59in.]) Cable specification (3000mm [118in.]) Order Code Example wWiring connection specification Note eEnvironmental protection Note S Single wiring D Double wiring ●Plug-in type cable specification 4 units DC24V Blank Standard -P IP65 or equivalent PBM4P-EL (Note: Except non-plug-in type) (Note: Non-plug-in type is compatible with IP65 or equivalent as standard) When used in combination with individual air supply and exhaust spacer PB-BP q w -Z e r stn.1 PB24C5-T2-D4 stn.2 PB24C5-T3-D4 stn.3 PB24C6-T3-D4 stn.4 PB-BPKD t qSpecification wWiring connection specification Note ePiping direction N Non-plug-in type M For D-sub connector, terminal block box, K PB-BP □□ Block-off plate T Front surface piping U Top surface piping S Single wiring D Double wiring serial transmission type (Note: Except non-plug-in type) Cable specification (700mm [27.6in.]) rPiping size K1 Cable specification (1500mm [59in.]) K3 Cable specification (3000mm 1 Rc1/8 2 Rc1/4 3 Rc3/8 [118in.]) tEnvironmental protection Note Blank Standard -P IP65 or equivalent (Note: Non-plug-in type is compatible with IP65 or equivalent as standard) Additional Parts Order Codes for PB Series Replacement of pilot valve Pilot valves are available as replacements. The valves for 14 (SA) and 12 (SB) are distinguished from the LED color. The 14 (SA) LED is red, and the 12 (SB) LED is green. Select the required type (a gasket and 2 mounting screws are supplied). PB -D4 14 (SA) pilot valve, DC24V -A1 14 (SA) pilot valve, AC100V -A2 14 (SA) pilot valve, AC200V -D4B 12 (SB) pilot valve, DC24V -A1B 12 (SB) pilot valve, AC100V -A2B 12 (SB) pilot valve, AC200V Port isolator Only 1 port isolator can be used on the same manifold. PB -SP Port isolator for P port Block-off plate (single unit) PB-BP q qEnvironmental protection Note Blank Standard Plate PB -P -P Plate (with 1 gasket) IP65 or equivalent (Note: Non-plug-in type is compatible with IP65 or equivalent as standard) PB Series Additional Parts Order Codes Safe block (single part) Can be mounted on the same valve station. Dustproof conduit cap (IP67) Serial transmission block (single part) PB -FS1 Dustproof conduit cap (G1/2) for YS4 q serial transmission block Applicable cable outer diameter φ8.5 [0.335in.]〜φ12.5 [0.492in.] PB-H q w (with 2 mounting screws) Note qPiping direction wValve specification T Front surface piping U Top surface piping -FT2 Dustproof conduit cap (G3/4) for terminal block Applicable cable outer diameter φ16.5 [0.650in.]〜φ18.5 [0.728in.] 2 2-position 3 3-position (Notes: 1. Mounting screw length will vary according to the specification. 2. Piping block is not included.) Individual air supply and exhaust spacer (single part) Wiring block (single part) PB q w e Cannot function as an individual air supply and exhaust spacer alone. It functions only when used in combination with the special dedicated valve □ Z). Since the spacer requires (PB24□ additional 1 station from the existing units, pay attention to the maximum number of units allowed on the manifold. qSpecification PB-Z q w e -01 qPiping direction wPiping size T Front surface piping U Top surface piping 1 Rc1/8 2 Rc1/4 3 Rc3/8 eEnvironmental protection Note -TL For left-side mounting of terminal block box -TR For right-side mounting of terminal block box -DL For left-side mounting of D-sub connector -DR For right-side mounting of D-sub connector wTotal number of coils used (enter only for D-sub connector) ⁝ -20 eEnvironmental protection Note Blank Standard -P IP65 or equivalent (Note: Available in -TL and -TR only) Blank Standard -P IP65 or equivalent (Note: Available only for the terminal block box and serial transmission type. The non-plug-in type is compatible with IP65 or equivalent as standard.) Cable assembly PB q w qSpecification PB -K1L Cable assembly length for D-sub -K3L Cable assembly length for D-sub Cable 3000mm [118in.] -K5L Cable assembly length for D-sub Cable 5000mm [197in.] -EN End block for non-plug-in type (one set of left and right) -EK End block for cable specification (one set of left and right) -ETL End block for left-side mounting of D-sub connector, terminal block box and serial transmission (one set of left and right) -ETR End block for right-side mounting of D-sub connector, terminal block box and serial transmission (one set of left and right) e qTransmission block specifications 01 02 11 21 31 32 41 42 51 52 61 71 81 A1 A2 B1 C1 D1 For UNI-WIRE System (16 outputs) For UNI-WIRE System (8 outputs) For Mitsubishi Electric MELSECNET/MINI-S3 For OMRON SYSBUS Wire System For OMRON B7A Link Terminal (Standard) For OMRON B7A Link Terminal (High speed) For KOYO ELECTRONICS INDUSTRIES SA Bus (16 outputs) For KOYO ELECTRONICS INDUSTRIES SA Bus (8 outputs) For SUNX S-LINK (16 outputs) For SUNX S-LINK (8 outputs) For Mitsubishi Electric MELSEC I/O LINK For Fuji Electric FA Components & Systems T Link Mini For KEYENCE KZ-R For OMRON CompoBus/S (16 outputs) For OMRON CompoBus/S (8 outputs) For Mitsubishi Electric CC-Link For OPCN-1 (former JPCN-1) For DeviceNet (CompoBus/D) wMounting position eEnvironmental protection L Left-side mounting Blank Standard R Right-side mounting -P IP65 or equivalent For details, see p.697. Cable 1500mm [59in.] End block set w Wiring base assembly Use this when adding plug-in type or serial transmission type valves. Includes a plug-in base and relating lead wires and cables. Connection rod Use when adding or subtracting valve units. Example: To add 2 valve units, enter PB-RZ-02. To subtract 2 units from the 6-unit manifold, enter PB-RS-04, and replace the connection rods for 6 units with the one for 4 units. PB q w qParts content wNumber of unit -RZ Connection rod -01 for expansion PB-V q w e -RS Connection rod qWiring specification Valve-side nameplate T1 For adding to 8 units or less of terminal block box or serial transmission type T2 For adding to 9 units or more of terminal block box or serial transmission type D1 For adding to 8 units or less of D-sub connector specification D2 For adding to 9 units or more of D-sub connector specification K1 For adding cable specification (700mm [27.6in.]) K2 For adding cable specification (1500mm [59in.]) K3 For adding cable specification (3000mm [118in.]) ⁝ -16 A plastic sheet used for sticking seals to, or placing paper on, and showing the name of the valve function. For mounting, insert it so that it fits into the upper and lower grooves. PB-M q wEnvironmental protection Note wWiring connection specification Nameplate (valve side) 40 [1.57]×(Pitch 24 [0.94]× No. of units) mm [in.] Transparent qNumber of units Blank Standard Blank Single wiring -01 -P IP65 or equivalent (Note: Available only for the terminal block box and serial transmission type. The non-plug-in type is compatible with IP65 or equivalent as standard.) Piping block (single part) PB -B1 Piping block Rc1/8 -B2 Piping block Rc1/4 -B3 Piping block Rc3/8 (with 1 gasket) D Double wiring eEnvironmental protection Note Blank Standard -P IP65 or equivalent (Note: Available in -T1 and -T2 only) ⁝ -16 Nameplate for terminal block box PB -MT Nameplate (for terminal block box) 71×83mm [2.80×3.27in.] Transparent PB Series Plug-In Type Pin (Terminal) Locations by Wiring Specification (Top View) ●D-sub connector JIS-specified pin locations ●Terminal block box (21 terminals, M3 screw) (maximum number of control pins: 20) (maximum number of control pins: 20) 3 1 1 2 3 4 5 6 7 8 9 10 11 12 13 2 5 4 7 6 9 8 11 10 13 12 15 14 19 COM 17 16 18 20 14 15 16 17 18 19 20 21 22 23 24 25 1〜20 : Control terminals COM : Common terminal 1〜10, 14〜23: Control pins 24, 25: COM pins (shorted within the wiring block) Cautions: 1. Since the DC24V specification has no polarity, it can be used for either positive common or negative common. 2. For the mounting screw, use M2.6. Cautions: 1. Set the tightening torque for the terminal screw (M3) at 49.0N・cm {5.0kgf・cm} [4.3in・lbf] or less. 2. Use crimping terminals of 6.2mm [0.244in.] or less for both the round terminal and the Y-shaped terminal. ●A dedicated cable assembly is available. For details, see p.697. 6.2 or below Detailed Diagrams for Wiring Systems 6.2 or below ※ For the relationship between the pin No. (terminal No.) and the corresponding solenoids, see p.694. ●D-sub connector ●Terminal block box 24,25(COM) COM 1 1 Solenoid Solenoid 1〜10 14〜23 n 20 Solenoid Solenoid At-a-glance Guide for Maximum Number of Control Solenoids in Plug-in Type & Serial Transmission Type Manifolds This is an at-a-glance guide for the maximum number of control solenoids by wiring specifications for the plug-in and serial transmission types. When ordering a manifold, ensure that the number of solenoid valves does not exceed the maximum number of control solenoids in the table below. Cautions: 1. For the cable outlet on top surface types, the maximum number of the units for the valve and block-off plate is 12 units, due to the cable bending space. 2. The individual air supply and exhaust spacer occupies 1 unit space. Ensure that the total number of units does not exceed 16 units. 最大連数 Wiring specification & transmission block specification 結線仕様 Maximum number of control solenoids ダブル配線 (-D) 詰め配線 (無記入) -U□:Cable top surface outlet type 24 12連 12連 -E□:Cable side surface outlet type 32 16連 16連 -D□□:D-sub connector(25P) 20 10連 -T□:Terminal block box(21 terminals) 20 10連 -01:For UNI-WIRE System (16 outputs) 16 8連 -02:For UNI-WIRE System (8 outputs) 8 4連 -11:For Mitsubishi Electric MELSECNET/MINI-S3 16 8連 -21:For OMRON SYSBUS Wire System 16 8連 -31:For OMRON B7A Link Terminal (Standard) 16 8連 -32:For OMRON B7A Link Terminal (High speed) 16 8連 -41:For KOYO ELECTRONICS INDUSTRIES SA Bus (16 outputs) 16 8連 -42:For KOYO ELECTRONICS INDUSTRIES SA Bus (8 outputs) 8 4連 -51:For SUNX S-LINK (16 outputs) 16 8連 -52:For SUNX S-LINK (8 outputs) 8 4連 -61:For Mitsubishi Electric MELSEC I/O LINK 16 8連 -71:For Fuji Electric FA Components & Systems T Link Mini 16 8連 -81:For KEYENCE KZ-R 16 8連 -A1:For OMRON CompoBus/S (16 outputs) 16 8連 -A2:For OMRON CompoBus/S (8 outputs) 8 4連 -B1:For Mitsubishi Electric CC-Link 16 8連 -C1:For OPCN-1 (former JPCN-1) 16 8連 -D1:For DeviceNet (CompoBus/D) 16 8連 シングルソレノイド、ダブル ソレノイド、ブロックプレート の搭載数により異なります。 制御するソレノイドの数が 最大制御ソレノイド点数以 下になるように連数を指定 してください。 なお、全体の連数が16連 を超える指定はできません。 Serial Transmission Block, Terminal Block (LED) Names ●For DeviceNet (OMRON CompoBus/D) Transmission block specification: -D1 Dip switch for various settings NS 1 2 3 4 5 6 7 8 9 0 O N MS Communication connector Power supply connector LED indicator Indicator State Lights up Color Green •No setting state Flashing MS Lights up Red •Serious breakdown Flashing •Minor breakdown Shuts off •No power supply Lights up Green Flashing NS Description •Normal state Lights up •Communication connection completed •No communication connection Red •Serious communication fault Flashing •Minor communication fault Shuts off •No power supply Remarks ※Conforms to DeviceNet (CompoBus/D) ● Number of outputs per block Maximum of 16 solenoids ● Related materials: User’s Manual, Document No.HV029 Cable Assembly ● Cable assembly for D-sub PB-K1L (Cable length L: 1500mm [59in.]) PB-K3L (Cable length L: 3000mm [118in.]) PB-K5L (Cable length L: 5000mm [197in.]) L (300) M2.6×0.45 25 24 23 22 21 20 19 18 17 16 15 14 Label (20) AWG28 13 12 11 10 9 8 7 6 5 4 3 2 1 (Connector no.) (B side) (A side) A side B side Connector No. q w e r t y u i o !0 Label No. 1 2 3 4 5 6 7 8 9 10 !1 !2 !3 !4 !5 !6 !7 !8 !9 @0 @1 @2 @3 11 12 13 14 15 16 17 18 19 20 COM COM @4 @5 PB Series Dimensions of Non-Plug-In Type (mm) PBM□N Front surface piping 41 6 24 24 (Pitch) 46 20 LED indicator 10.5 (18) mPm (6) P Rc1/8 external pilot port (with 1 plug) 7 Unit Dimensions L 13 Manual override cover 6.5 4-R3.25 12 P2 4A 4A P 1 40 28 77.5 39 139 4A 5 R1 41 27 C L O S E 28 7 88 42 163 4A R2 3 2B 2B 2B 2B 1 P 7 O P E N 20 6.5 20 PB-M□ (Nameplate) 16 Number of units L 1 92 P 80 2 116 104 3 140 128 4 164 152 5 188 176 6 212 200 7 236 224 8 260 248 9 284 272 10 308 296 11 332 320 12 356 344 13 380 368 14 404 392 15 428 416 16 452 440 Stn.1 Stn.2 Stn.3 Stn.4 PB24C5-T2-G2 PB24HC6-T3-39 PB24C7-T3-G1 R2 3 1 P P 1 5 R1 8-Rc1/2 (with 5 plugs) 28 6 20 2(B)port 17 37 25 60 18 63.6 PB24C5-T2-G1 20 4(A)port 34 PBM□N Top surface piping 41 6 Number of units L 1 92 80 LED indicator 2 116 104 Manual override cover 3 140 128 4 164 152 5 188 176 6 212 200 7 236 224 8 260 248 9 284 272 10 308 296 11 332 320 12 356 344 13 380 368 4(A)port 14 404 392 2(B)port 15 428 416 16 452 440 24 46 24 (Pitch) 20 10.5 (18) mPm (6) P Rc1/8 external pilot port (with 1 plug) 7 Unit Dimensions L 13 4-R3.25 6.5 20 12 4A 4A 3 5 2B 2B 2B 2B 1 28 39 R2 1 R1 P 41 31.5 P 27 25 88 77.5 C L O S E 28 4A 132 135.6 4A 7 42 159.6 P2 O P E N 20 20 16 Stn.1 Stn.2 Stn.3 Stn.4 PB24C5-U2-G2 PB24HC6-U3-39 PB24C7-U3-G1 P 1 1 P 5 R1 28 3 8-Rc1/2 (with 5 plugs) 20 PB-M□ (Nameplate) 20 34 17 37 R2 6 40 60 PB24C5-U2-G1 67 6.5 P PB Series Dimensions of Plug-In Type (mm) PBM□P-UL Cable outlet type Top surface piping 2 4-G3/4 Cable top surface outlet at the left (-UL) 37 With 3 wiring outlets External pilot port (with 1 plug) 18 17 2 P 6 24 LED indicator Rc1/8 L Manual override cover 24 (Pitch) Unit Dimensions 46 17 18 4-R3.25 6.5 001 002 Number of unit 12 4A 4A 4A 4A R2 3 5 2B 2B 2B 2B 1 R1 P 41 1 27 P 28 39 159.6 135.6 132 77.5 31.5 25 C L O S E 28 7 42 99.5 P2 O P E N 20 20 4(A)port 6.5 16 2(B)port Stn.1 Stn.2 Stn.3 Stn.4 PB24C5-U2 P 80 2 116 104 3 140 128 4 164 152 5 188 176 6 212 200 7 236 224 8 260 248 9 284 272 10 308 296 11 332 320 12 356 344 13 380 368 14 404 392 15 428 416 16 452 440 6 R2 3 P 1 1 P 5 R1 PB-M□ (Nameplate) 20 28 1 92 37 P PB24C7-U3 17 3 L 1 Note: Cable top surface outlets accommodates maximum of 12 units. PB24HC6-U3 PB24C5-U2 40 R2 67 ●Side surface left outlet: -EL 60 8-Rc1/2 (with 5 plugs) Number of units 20 34 PBM□P-UL Cable outlet type Front surface piping 37 With 3 wiring outlets 2 4-G3/4 L Cable top surface outlet at the left (-UL) 24 LED indicator Rc1/8 External pilot port (with 1 plug) 18 2 P 17 Manual override cover Unit Dimensions 6 24 (Pitch) 46 17 18 4-R3.25 6.5 001 002 Number of unit 4A 4A 4A 4A P 1 40 28 77.5 39 132 139 163 12 5 R1 41 27 C L O S E 28 7 42 R2 3 2B 2B 2B 2B 1 P 7 O P E N 20 6.5 20 PB-M□ (Nameplate) 16 Stn.1 Stn.2 Stn.3 Stn.4 PB24C5-T2 1 PB24C7-T3 6 R2 3 1 P P 1 5 R1 20 2(B)port 4(A)port 20 34 28 P PB24C5-T2 L 1 92 P 80 2 116 104 3 140 128 4 164 152 5 188 176 6 212 200 7 236 224 8 260 248 9 284 272 10 308 296 11 332 320 12 356 344 13 380 368 14 404 392 15 428 416 16 452 440 Note: Cable top surface outlets accommodates maximum of 12 units. 17 3 18 R2 8-Rc1/2 (with 5 plugs) 63.6 60 25 ●Side surface left outlet: -EL PB24HC6-T3 37 99.5 P2 Number of units PBM□P-TL Terminal block box Front surface piping Unit Dimensions 4 1 L2 LED indicator -P:IP65 External pilot port (with 1 plug) Rc1/8 4-R3.25 L1 P Manual override cover 24 6 24 (Pitch) 46 4 6.5 2 6 Standard Standard 2 12 P2 4A 4A 2B 2B 2B 2B 1 P 41 28 39 3 R1 -P:IP65 7 O P E N 6 O S E R2 5 27 1 40 P PB-MT: Nameplate (Option)71×83 L1 L2 1 92 166 P 80 2 116 190 104 3 140 214 128 4 164 238 152 5 188 262 176 6 212 286 200 7 236 310 224 8 260 334 248 9 284 358 272 10 308 382 296 11 332 406 320 12 356 430 344 13 380 454 368 14 404 478 392 15 428 502 416 16 452 526 440 4A 114 77.5 132 139 163 4A Number of units 20 20 PB-M□ (Nameplate) Stn.1 Stn.2 Stn.3 Stn.4 74 PB24C5-T2-B 20 PB24HC6-T3-B PB24C5-T2-B PB24C7-T3-B 3 1 P P 1 5 R1 1 37 60 R2 18 25 17 28 37 60 63.6 6 32 (Width across flats) 2-G3/4 (Cable outlet port) 8-Rc1/2 (with 5 plugs) 2(B)port 20 20 4(A)port 34 PBM□P-DEL D-sub connector Front surface piping L2 2 LED indicator L1 Manual override cover P Rc1/8 External pilot port (with 1 plug) 24 Unit Dimensions 6 24 (Pitch) 46 6.5 4-R3.25 P2 12 4A 4A 4A 3 2B 2B 2B 2B 1 28 R1 P 41 5 7 O P E N 9 O S E R2 1 27 P 40 39 114 77.5 132 139 57 163 4A 20 20 PB-M□ (Nameplate) Stn.1 Stn.2 Stn.3 Stn.4 PB24C5-T2-B 51 7 9 PB24C5-T2-B PB24HC6-T3-B PB24C7-T3-B 6 R2 3 1 P P 1 5 R1 8-Rc1/2 (with 5 plugs) 20 2(B)port 4(A)port 20 34 18 25 17 28 37 60 63.6 46 1 60 (67) Top surface and left side mounting case -DUL Number of units L1 L2 1 92 138 P 80 2 116 162 104 3 140 186 128 4 164 210 152 5 188 234 176 6 212 258 200 7 236 282 224 8 260 306 248 9 284 330 272 10 308 354 296 11 332 378 320 12 356 402 344 13 380 426 368 14 404 450 392 15 428 474 416 16 452 498 440 PB Series Dimensions of Serial Transmission Type (mm) PBM□S Front surface piping 5 Rc1/8 External pilot port (with 1 plug) L2 2 LED indicator L1 Manual override cover P 24 Unit Dimensions 6 24 (Pitch) 46 4 Standard 4A 4A 4A 2B 2B 2B 2B 1 R1 P -P:IP65 41 28 39 3 5 7 O P E N 9 O S E R2 1 27 P 40 114 4A YS401 L 142649 24V OV 77.5 G 132 12 ADDRESS 1 2 4 8 163264128 D 139 P2 L1 L2 1 92 166 P 80 2 116 190 104 3 140 214 128 4 164 238 152 5 188 262 176 6 212 286 200 7 236 310 224 8 260 334 248 9 284 358 272 10 308 382 296 11 332 406 320 12 356 430 344 13 380 454 368 14 404 478 392 15 428 502 416 16 452 526 440 SEND 24V OV 163 POWER G 40 D MADE IN JAPAN 6.5 4-R3.25 Number of units 20 20 PB-M□ (Nameplate) Serial transmission block (Panel design varies according to transmission block specifications.) 74 Stn.1 Stn.2 Stn.3 Stn.4 26 PB24C5-T2-B PB24C5-T2-B PB24HC6-T3-B PB24C7-T3-B 3 1 P P 1 5 R1 8-Rc1/2 (with 5 plugs) 20 2(B)port 4(A)port 20 34 18 25 17 28 37 60 63.6 R2 1 53 79 6 PB Series Dimensions of Mounted Valve (mm) Remark: Diagrams show the wiring specification grommet type L connector: -G2. 5-port, 2-position PB24□C5 PB24□C6 18 25 60 63.6 1.4 1.5 56 (300) 43 ●Piping specification: Front surface piping(-T□) 21 24 139 ●Piping specification: Top surface piping(-U□) 2-Rc3/8(Rc1/4, 1/8) 135.6 67 25 60 75.5 24 5-port, 3-position PB24□C7 PB24□C8 PB24□C9 18 25 60 63.6 1.4 1.5 21 24 163 ●Piping specification: Top surface piping(-U□) 2-Rc3/8(Rc1/4, 1/8) 159.6 25 60 75.5 67 56 (300) 43 ●Piping specification: Front surface piping(-T□) 24 PB Series Dimensions of Options (mm) ●Block-off plate(PB-BP□) ●Individual air supply and exhaust spacer(PB-Z□) 24 (Pitch) 46 24 (Pitch) 12 1 R2 3 2B PB-Z□ Individual air supply and exhaust spacer 4A 5 R1 P 1 1 P R2 3 2B 24 5 R1 1 P 3 1 P P 1 5 R1 60 R2 63.6 24 60 P 12 P2 PB-BP Block-off plate 4A R2 3 1 P P 1 5 R1 63.6 P2 46 1(P)port 3, 5(R)port Piping specification: Front surface piping(-T□) 1 R2 3 2B 2B 5 R1 1 P 4A 132 135.6 4A P 1 R2 3 2B 2B 5 R1 1 P 61.3 159.6 132 4A 37.3 P 12 P2 4A 186 Piping specification: Top surface piping(-U□) 12 P2 210 ●Safe block 7 Residual pressure exhaust manual override For PB24□C7, C8, C9 (3 positions) For PB24□C7, C8, C9 (3 positions) Residual pressure exhaust manual override 7 60 R2 3 1 P 60 63.6 114 For PB24□C5, C6 (2 positions) For PB24□C5, C6 (2 positions) 37.3 ●Safe block P 1 5 R2 3 1 P P 1 5 R1 R1 2(B)port 4(A)port ●Dustproof conduit cap: For serial transmission(-FS1) ●Dustproof conduit cap: For terminal block box(-FT2) D POWER G 12 P2 12 4A D ADDRESS 1 2 4 8 163264128 24V OV SEND MADE IN JAPAN P2 G 1 R2 3 2B 2B P 1 R2 3 4A 4A 2B 2B 29.5 6 (MAX) 36.5 (MAX) YS401 L 142649 24V OV P 4A 26 Applicable cable outer diameter φ8.5〜12.5 20 Applicable cable outer diameter φ16.5〜18.5 ">
Advertisement