Koganei ZC301_305 - ZC301 ZC305 2-lead wire Instruction manual
Koganei ZC301_305 - ZC301 ZC305 2-lead wire is a Reed Switch Type Sensor Switch designed for use with Pen cylinders. It features a 2-lead wire connection and operates with a DC5〜28V, AC85〜115V (r.m.s.) load voltage. The switch can handle DC0.1〜40mA, AC2〜25mA load current. The instruction manual provides details about the product's specifications, internal circuit, and dimensions.
PDF
Download
Document
Advertisement
Advertisement
BKUA002 Ver.1.0 Air Cylinder SENSOR SWITCH INSTRUCTION MANUAL Ver.1.0 Points of Wiring Solid State Type Sensor Switches ZC130□, ZC230□, ZC330□ ZC630□, ZE135□, ZE235□ ZG530□, ZD136C, ZB430□ ZC153□, ZC253□, ZC353□, ZC653□ ZE155□, ZE255□, ZE175□, ZE275□, ZG553□, CS9H□ ●2-lead wire type ●3-lead wire with NPN output ●3-lead wire with PNP output ● Basic connection ● Basic connection ● Basic connection Brown Sensor switch Load DC10〜28V Blue Brown Black Load Blue Sensor switch DC4.5〜28V Brown Black Load Blue Sensor switch DC4.5〜28V ● Connecting with relays ● Connecting with relays ● Connecting with relays (+) (+) (+) (−) (−) (−) Brown CR Brown Sensor switch Blue CR Black Sensor switch Blue Sensor Black CR switch Brown Blue AND (series) connection and OR (parallel) connection Relay Sensor switch Relay Sensor switch Relay Sensor switch AND (series) connection and OR (parallel) connection AND (series) connection and OR (parallel) connection Sensor switch Relay Sensor switch Relay Sensor switch Relay Sensor switch Relay Sensor switch Relay Sensor switch Relay Relay contact Relay contact Relay contact Load Load Load Relay contact Relay contact Relay contact Load Load Load ● Connecting with a solenoid valve ● Connecting with a solenoid valve ● Connecting with a solenoid valve (+) (+) (+) (−) (−) (−) Brown Brown Sensor switch Black Blue Sensor switch Blue Brown Sensor switch Black Blue ● Connecting with a programmable controller Brown Sensor switch Blue Programmable controller input terminal ● Connecting with a programmable controller ● Connecting with a programmable controller Sensor switch Brown Black Blue (+) COM. Cautions: 1. Connect the lead wires according to their color. Incorrect wiring will cause damage to the sensor switch since there is no overcurrent protection. 2. With the inductive load of an electromagnetic relay, etc., the use of a surge protection diode is recommended. 3. Avoid the use of AND (series) connections because the circuit voltage will drop in proportion to the number of sensor switches. 4. When using an OR (parallel) connection, it is possible to connect sensor switch outputs directly (ex: using corresponding black lead wires). Be aware of load return errors since current leakage increases with the number of switches. Programmable controller input terminal (+) COM. Sensor switch Brown Black Blue Programmable controller input terminal (−) COM. 5. Because the sensor switches are magnetically sensitive, avoid using them in locations subject to strong external magnetic fields or bringing them in close proximity to power lines and areas where large electric currents are present. In addition, do not use magnetized materials for the mounting bracket, since this may cause erratic operation. 6. Do not excessively pull on or bend the lead wires. 7. Avoid using the sensor switches in environments where chemicals or gas are present. 8. Consult us for use in environments subject to water or oil. Contact Protection for Reed Switch Type Sensor Switches In order to use the reed switch type sensor switches in a stable condition, take the following contact protection measures. ● When you connect inductive load (electromagnetic relay, etc.). Inductive load Sensor switch Serge absorption element ●When capacity serge is generated. (When lead wire length exceeds 10m.) Choke coil: 1〜5mH C surge suppressor As close as possible For DC… Diode, CR, etc. For AC… CR, etc. Diode: Forward current should be more than the circuit current. Reverse voltage should be peak inverse voltage that is 10 times or more of the circuit voltage. CR: C=0.01〜0.1µF R=1〜4kΩ Load Products compliant with the EMC Directive ZC130□, ZC153□ Solid State Type Sensor Switch Applicable cylinders ● Knock cylinders double acting type ● Multi mount cylinders ● Pen cylinders ● DYNA cylinders ● SD cylinders ● TDAφ φ 6 [0.236in.] ● AMT ● ARTB ● ACY (For the intermediate stopper) ● ORV ● ORK φ 16 [0.630in.] ● RAP ● RAN ● Swing cylinders ● Air Hands CHDUL ● SHM Specifications Model Item Wiring type ZC130□ ZC153□ 2-lead wire 3-lead wire − DC4.5〜28V Load voltage DC10〜28V DC4.5〜28V Load current 4〜50mA 100mA MAX. − 10mA MAX. (DC24V) 3.5V MAX. 0.5V MAX. (At 50mA load current) Power supply voltage Consumption current Internal voltage drop Note 1 1mA MAX. (DC24V) Leakage current 50µA MAX. (DC24V) 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) 294.2m/s2 [30G] (Non-repeated shock) Shock resistance Note 2 Vibration resistance 2 Note 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wire Note 3 PVC 0.2SQ×2-lead×R PVC 0.2SQ×3-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range 20g [0.71oz.] (For lead wire length A: 1000mm) Mass Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit ZC130□ ZC153□ LED indicator LED indicator Brown (+) Diode (For wrong polarity protection) Brown (+) Load Black Switch main circuit DC10〜28V DC4.5〜28V Blue (−) Blue (−) (Switch) Load Switch main circuit (External wiring) (Switch) (External wiring) Zener diode (For surge suppression) Zener diode (For surge suppression) Dimensions (mm) ZC130□ ZC153□ Model marking surface Indicator lamp (1.5) (1.5) (8.5) 25 φ3 φ3 0.3 or less 0.3 or less □4 Model marking surface Indicator lamp (8) Maximum sensing location (Cylinder mounting surface) (60) R □4 (8.5) 25 (8) Maximum sensing location (Cylinder mounting surface) (60) R Products compliant with the EMC Directive ZC230□, ZC253□ Solid State Type Sensor Switch Applicable cylinders ●Pen cylinders Specifications Model Item Wiring type ZC230□ ZC253□ 2-lead wire 3-lead wire − DC4.5〜28V Load voltage DC10〜28V DC4.5〜28V Load current 4〜50mA 100mA MAX. − 10mA MAX. (DC24V) 3.5V MAX. 0.5V MAX. (At 50mA load current) Power supply voltage Consumption current Internal voltage drop Note 1 1mA MAX. (DC24V) Leakage current 50µA MAX. (DC24V) 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 2 Vibration resistance 294.2m/s2 [30G] (Non-repeated shock) Note 2 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wire Note 3 PVC 0.2SQ×2-lead×R Ambient temperature PVC 0.2SQ×3-lead×R 0〜60°C [32〜140°F] −10〜70°C [14〜158°F] Storage temperature range Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000m [118in.] Internal Circuit ZC230□ ZC253□ LED indicator LED indicator Brown (+) Diode (For wrong polarity protection) Brown (+) Load Black Switch main circuit DC10〜28V DC4.5〜28V Blue (−) Blue (−) (External wiring) (Switch) Load Switch main circuit (Switch) (External wiring) Zener diode (For surge suppression) Zener diode (For surge suppression) Dimensions (mm) ZC230□ ZC253□ Indicator lamp (1.5) φ3 φ3 0.3 or less 0.3 or less (1.5) □4 Model marking surface Indicator lamp Model marking surface (8.5) 25 (8) Maximum sensing location (Cylinder mounting surface) (60) R □4 (8.5) 25 (8) Maximum sensing location (Cylinder mounting surface) (60) R Products compliant with the EMC Directive ZC330□, ZC353□ Solid State Type Sensor Switch Applicable cylinders ●AGTB ● AGTC Specifications Model Item Wiring type ZC330□ ZC353□ 2-lead wire 3-lead wire − DC4.5〜28V Load voltage DC10〜28V DC4.5〜28V Load current 4〜50mA 100mA MAX. − 10mA MAX.(DC24V) 3.5V MAX. 0.5V MAX. (At 50mA load current) Power supply voltage Consumption current Internal voltage dropNote 1 1mA MAX. (DC24V) Leakage current 50µA MAX.(DC24V) 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistanceNote 2 294.2m/s2 [30G] (Non-repeated shock) Note 2 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) Vibration resistance IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wireNote 3 PVC 0.2SQ×2-lead×R PVC 0.2SQ×3-lead×R Ambient temperature 0〜60°C [32〜140°F] −10〜70°C [14〜158°F] Storage temperature range Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000m [118in.] Internal Circuit ZC330□ ZC353□ LED indicator LED indicator Brown (+) Diode (For wrong polarity protection) Brown (+) Load Black Switch main circuit DC10〜28V DC4.5〜28V Blue (−) (Switch) Load Switch main circuit Blue (−) (External wiring) (Switch) Zener diode (For surge suppression) (External wiring) Zener diode (For surge suppression) Dimensions (mm) ZC330□ ZC353□ Model marking surface Indicator lamp 1 (8.5) 25 SUS plate (8) Maximum sensing location (60) R φ3 4 φ3 4 SUS plate 0.3 or less (1.5) 0.3 or less (1.5) 4 Model marking surface Indicator lamp 4 1 (8) Maximum sensing location (8.5) 25 (60) R Products compliant with the EMC Directive ZG530□, ZG553□ Solid State Type Sensor Switch Applicable cylinders ● Slim cylinders ● Twinport cylinders ● GA ● ORC ● ORCA ● ORGA ● ORKNote ● MRG ● RAK ● Swing cylinders ● Twist cylinders Note: Excluding ORK φ16 [0.630in.]. Specifications Model Item Wiring type ZG530□ ZG553□ 2-lead wire 3-lead wire − DC4.5〜28V Load voltage DC10〜28V DC4.5〜28V Load current 4〜50mA 100mA MAX. − 10mA MAX. (DC24V) 4.5V MAX. 0.5V MAX. (At 50mA load current) Power supply voltage Consumption current Internal voltage drop Note 1 1mA MAX. (DC24V at 25°C [77°F]) Leakage current 50µA MAX. (DC24V) 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 2 Vibration resistance 294.2m/s2 [30G] (Non-repeated shock) Note 2 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wire Note 3 PVC 0.2SQ×2-lead×R Ambient temperature PVC 0.2SQ×3-lead×R 0〜60°C [32〜140°F] −10〜70°C [14〜158°F] Storage temperature range Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000m [118in.] Internal Circuit ZG530□ ZG553□ LED indicator LED indicator Brown (+) Diode (For wrong polarity protection) Brown (+) Load Black Switch main circuit DC10〜28V DC4.5〜28V Blue (−) Blue (−) (Switch) Load Switch main circuit (External wiring) (Switch) (External wiring) Zener diode (For surge suppression) Zener diode (For surge suppression) Dimensions (mm) ZG530□ ZG553□ Indicator lamp 10 (11) 22 Maximum sensing location (Cylinder mounting surface) R (8) (60) 0.5 7.3 3.5 7 6 0.5 7 7.3 6 φ3.4 10 φ3.4 7 7 Indicator lamp 3.5 (11) 22 Maximum sensing location (Cylinder mounting surface) R (8) (60) Products compliant with the EMC Directive ZC630□, ZC653□ Solid State Type Sensor Switch Applicable cylinders ●Axis cylinders Specifications Model Item Wiring type ZC630□ ZC653□ 2-lead wire 3-lead wire − DC4.5〜28V Power supply voltage Load voltage DC10〜28V DC4.5〜28V Load current 4〜50mA 100mA MAX. (DC24V) − 10mA MAX. (DC24V) 3.5V MAX. 0.5V MAX. (At 50mA load current) Consumption current Internal voltage dropNote 1 1mA MAX. (DC24V) Leakage current 50µA MAX. (DC24V) 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) 294.2m/s2 [30G] (Non-repeated shock) Shock resistanceNote 2 2 Note 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) Vibration resistance IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wireNote 3 PVC 0.2SQ×2-lead×R PVC 0.2SQ×3-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range 20g [0.71oz.] (For lead wire length A: 1000mm) Mass Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000m [118in.] Internal Circuit ZC630□ ZC653□ LED indicator LED indicator Brown (+) Diode (For wrong polarity protection) Brown (+) Load Black Switch main circuit DC10〜28V DC4.5〜28V Blue (−) Blue (−) (Switch) Load Switch main circuit (External wiring) (Switch) (External wiring) Zener diode (For surge suppression) Zener diode (For surge suppression) Dimensions (mm) ZC630□ ZC653□ Indicator lamp 4 4 Indicator lamp 3.5 3.5 16.5 (16.5) 33 φ3 φ3 1.5 1.5 16.5 (8) Maximum sensing location (Cylinder mounting surface) (60) R (16.5) 33 (8) Maximum sensing location (Cylinder mounting surface) (60) R Products compliant with the EMC Directive ZE135□, 155□, 235□, 255□ Solid State Type Sensor Switch Applicable cylinders ● Mini bit cylinders ● Jig cylinders C series ● Jig cylinders JC series ● Mini guide sliders ● Jig cylinders with guides ● Twin rod cylinders B series ● Rod sliders ● Multi sliders ● Z sliders ● WS ● WT ● ACYNote1 ● ACZNote1 ● Flat rodless cylindersNote1 ● ORVNote1 ● ORS, MRSNote1 ● ORW, MRWNote1 ● NHC1 series ● Air Hands NHB ● Wide type Air Hands WHDPNote2 ● Flat type Air Hands ● RAG ● RAT ● DJ cylinders Notes: 1. Only the horizontal lead wire type 2. Only the vertical lead wire type Specifications Model Item ZE135□ ZE155□ ZE235□ ZE255□ 2-lead wire 3-lead wire 2-lead wire 3-lead wire − DC4.5〜28V − DC4.5〜28V Load voltage DC10〜28V DC4.5〜28V DC10〜28V DC4.5〜28V Load current 4〜20mA at 25°C [77°F], and 10mA at 60°C [140°F]. 50mA MAX. 4〜20mA at 25°C [77°F], and 10mA at 60°C [140°F]. 50mA MAX. − 8mA MAX. (DC24V) − 8mA MAX. (DC24V) 4V MAX. 0.5V MAX. (10V or less at 20mA) 4V MAX. 0.5V MAX. (10V or less at 20mA) 0.7mA MAX. (DC24V, 25°C [77°F]) 50µA MAX. (DC24V) 0.7mA MAX. (DC24V, 25°C [77°F]) 50µA MAX. (DC24V) Wiring type Lead wire direction Horizontal Power supply voltage Consumption current Internal voltage drop Note 1 Leakage current Vertical 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) 294.2m/s2 [30G] (Non-repeated shock) Shock resistance Note 2 Vibration resistance 2 Note 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wire Note 3 PCCV 0.2SQ×2-lead (Brown and blue) ×R PCCV 0.15SQ×3-lead (Brown, blue, and black) ×R PCCV 0.2SQ×2-lead (Brown and blue) ×R PCCV 0.15SQ×3-lead (Brown, blue, and black) ×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range 15g [0.53oz.] (For lead wire length A: 1000mm), 35g [1.23oz.] (For lead wire length B: 3000mm) Mass Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000m [118in.] Internal Circuit ZE155□, ZE255□ ZE135□, ZE235□ LED indicator LED indicator Brown (+) Diode (For wrong polarity protection) Brown (+) Load Black Switch main circuit DC10〜28V DC4.5〜28V Blue (−) (Switch) Load Switch main circuit Blue (−) (External wiring) (Switch) (External wiring) Zener diode (For surge suppression) Zener diode (For surge suppression) Dimensions (mm) ●Vertical lead wire ZE235□, ZE255□ M2.5 Slotted setscrew M2.5 Slotted setscrew Indicator lamp Indicator lamp 135 ZE 235 8 60 4.6 8 φ2.6 60 R (R=A:1000, B:3000) 10.5 15.5 Maximum sensing location 4.6 (6) R (R=A:1000, B:3000) 4 ZE φ2.6 4 ●Horizontal lead wire ZE135□, ZE155□ (6) 15 Maximum sensing location Products compliant with the EMC Directive ZE175□, ZE275□ 3-lead Wire PNP Output Type Solid State Sensor Switches Applicable cylinders ●Mini bit cylinders ●Jig cylinders C series ●Jig cylinders JC series ●Mini guide sliders ●Jig cylinders with guides ●Twin rod cylinders B series ●Rod sliders ●Multi sliders ●Z sliders ●WS ●WT ●ACY Note 2 ●ACZ Note 2 ●Flat rodless cylindersNote 2 ●ORV Note 2 ●ORS, MRS Note 2 ●ORW, MRW Note 2 ●NHC1 series ●Air Hands NHB ●Wide type Air Hands WHDP Note 3 ●Flat type Air Hands ●RAG ●RAT ●Three-finger Hands Notes: 1. Because the same conductor as the robot cable is used, it exhibits superior bending resistance. 2. Horizontal lead wire only 3. Vertical lead wire only Specifications Model Item ZE175□ ZE275□ 3-lead wire PNP output Wiring type Horizontal Lead wire direction Vertical Power supply voltage DC4.5〜28V Load voltage DC4.5〜28V 50mA MAX. Load current 10mA MAX. (DC24V) 0.5V MAX. (10V or less at 20mA) Consumption current Internal voltage drop Note 1 50μA MAX. (DC24V) Leakage current 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) 294.2m/s2 [30G] (Non-repeated shock) Shock resistance Note 2 Vibration resistance 2 Note 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wire Note 3 PCCV 0.15SQ×3-lead (Brown, blue, and black) ×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range 15g [0.53oz.] (For lead wire length A: 1000mm [39in.]), 35g [1.23oz.] (For lead wire length B: 3000mm [118in.]), 15g [0.53oz.] (For lead wire length G: 300mm [11.8in.] with M8 connector) Mass Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.], G; 300mm [11.8in.] with M8 connector Internal Circuit ZE175□, ZE275□ (+) Brown 1 Switch main circuit Black (Switch) Diode (for reverse current protection) 4 DC4.5〜28V Load 3 (−) Blue (External wiring) Zener diode (for surge suppression) Dimensions mm [in.] φ2.6 [0.102] 4 [0.157] ●Horizontal Lead Wire ZE175A M2.5 Slotted head setscrew ZE175B Indicator lamp ZE 4.6 [0.181] 175 8 [0.315] (6 [0.236]) Maximum sensing location (60 [2.36]) R (R=A:1000 [39], B:3000 [118]) 15.5 [0.610] ZE175G φ9 [0.354] ZE 175 4.6 [0.181] φ2.6 [0.102] Indicator lamp 4 (OUT) 3 (−) 1 (+) Maximum sensing location (6 [0.236]) 15.5 [0.610] Connector pin location (300 [11.81]) 31 [1.220] ●Vertical Lead Wire ZE275A ZE275B ZE275G Connector pin location M2.5 Slotted head setscrew 4 (OUT) M2.5 Slotted head setscrew 1 (+) 3 (−) φ9 [0.354] 31 [1.220] (60 [2.36]) Maximum sensing location φ2.6 [0.102] Indicator lamp 10.5 [0.413] 15 [0.591] 4.6 [0.181] (6 [0.236]) 275 10.5 [0.413] 4.6 [0.181] φ2.6 [0.102] ZE R (R=A: 1000 [39], B: 3000 [118]) 275 4 [0.157] 8 [0.315] 4 [0.157] Indicator lamp ZE (300) ([11.81]) 4 [0.157] M2.5 Slotted head setscrew (6 [0.236]) 15 [0.591] Maximum sensing location Products compliant with the EMC Directive CS9H□, ZB430□ Solid State Type Sensor Switch Applicable cylinders ● Jig cylinders J series ● TDAφ φ 10[0.394in.]〜 〜 φ 32[1.260in.] (previous type) ● Slide Units ● SHM Specifications Model Item CS9H□ ZB430□ 3-lead wire 2-lead wire Power supply voltage DC4.5〜28V DC10〜28V Load voltage DC4.5〜28V DC10〜28V Load current 100mA MAX.(Ta=45°C [113°F]) 4〜50mA Wiring type 15mA MAX. (DC24V) − 0.8V MAX. (At 50mA load current) 4.5V MAX. Consumption current Internal voltage dropNote 1 1mA MAX. (DC24V at 25°C [77°F]) 50µA MAX. (DC24V) Leakage current 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 2 Vibration resistance 294.2m/s2 [30G] (Non-repeated shock) Note 2 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection When ON: Red LED indicator lights up Operation indicator Lead wire Note 3 PVC 0.2SQ×3-lead×R Ambient temperature PVC 0.2SQ×2-lead×R 0〜60°C [32〜140°F] Storage temperature range −10〜70°C [14〜158°F] Mass (The mounting bracket is included.) 40g [1.41oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000m [118in.] Internal Circuit CS9H□ ZB430□ LED indicator LED indicator Diode (For wrong polarity protection) Brown (+) Brown (+) Black Load Switch main circuit DC4.5〜28V Switch main circuit DC10〜28V Blue (−) (Switch) Load Blue (−) (Switch) (External wiring) (External wiring) Zener diode (For surge suppression) Zener diode (For surge suppression) Dimensions (mm) ZB430□ Indicator lamp 2 10 1 10 1 2 R R 8.5 7 Indicator lamp 8.5 7 CS9H□ Maximum sensing location (8) 22 Maximum sensing location (8) 22 ZD136C Strong Magnetic Field Resistant Sensor Switch Applicable cylinders ●Jig cylinders JC series Specifications Operation Model Item ZD136C Wiring type 2-lead wire Load voltage DC10〜28V Load current 5〜50mA Internal voltage drop Operation indicator Operation output Green Red ON OFF OFF 1.0mA MAX 50ms MAX. 80ms MAX. Response time ON delay = 40ms TYP. OFF delay= 65ms TYP. Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) 30ms MIN. Shock resistanceNote 2 50ms MIN. Vibration resistance 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) Environmental protection IP67 (IEC standard), JIS C0920 (water-proof type) Setting range Unstable range Lead wireNote 3 In an unstable range, the red LED lights up, while the green LED lights up when in the setting range. Operation output is ON whenever an LED is lighted. There is no change in operating output (sensor switch output) between the setting range and unstable range. 294.2m/s 2 [30G] (Non-repeated shock) Note 2 Operation indicator OFF Red Piston movement 5.0V MAX. (At load current 50mA)Note 1 Leakage current OFF When ON: Green LED indicator lights up When ON: Red LED indicator lights up Oil-resistant, spatter-resistant cabtyre cable 2-lead, 0.5SQ×R Magnetic field resistanceNote 2 AC17000A Ambient temperature 0〜60°C [32〜140°F] Storage temperature range −10〜70°C [14〜158°F] Mass 270g [9.52oz.] Notes: 1. When using a programmable controller with input voltage of 12V, care should be taken about the programmable controller’s ON voltage. The sensor switch’s internal voltage drop could prevent use of the device. 2. Measured by Koganei test standard. 3. Lead wire lengthR: C; 5000mm [197in.] Internal Circuit and Outline of Operations ●The strong magnetic field resistant sensor switch can be used in locations subjected to disturbance by AC magnetic fields (areas near AC welders, etc.). The strong magnetic field resistant sensor switch has a function of changing its output only when the magnetic field is applied for a fixed period of time in an ON or OFF state. Magnetic fields generated by welding currents at areas near the AC welder change the current at set intervals, and the magnetic field is not continuously generated longer than the time required for changing the sensor switch output. Therefore, the sensor switch output is not affected by magnetic fields generated by welding current from AC welders. (4) Load Brown(+) Switch main circuit Sensor element DC10〜28V Blue(−) (3) (External circuit) (Internal circuit) Caution: ZD136C is a non-polarity type. Connect either the brown or the blue lead wire to the load. Caution : The sensor switch cannot be used in areas near DC welders (including inverters), because the magnetic fields generated by the DC welder remain constant. Outline of operations ●In the case of no disturbance by an AC magnetic field Magnetic field No disturbance by an AC magnetic field Disturbance by an AC magnetic field Sensor switch Without magnet With magnet Without magnet With magnet Sensor element OFF ON OFF←→ON OFF←→ON Sensor switch output OFF ON OFF ON When a sensor element detects the magnetic field of a magnet, the sensor switch output changes to ON about 40ms later. When the magnetic field generated by the magnet disappears, sensor switch output returns to the OFF position about 65ms later. ●In the case of existing disturbance by an AC magnetic field Disturbance by an AC magnetic field causes sensor elements to switch repeatedly from ON to OFF states regardless of whether there is a magnet or not. However, use of an ON delay or OFF delay circuit allows sensor switch output to proceed without effect from disturbances by the AC magnetic field. Dimensions (mm) ●ZD136C Indicator lamp (φ9) 11 22 2-φ3.5 20 φ6 (4) (4) 8 6 9 (7) Maximum sensing location (Cylinder mounting surface) (20) 30 5000 60 Products compliant with the EMC Directive CS5T□, CS11T□ Reed Switch Type Sensor Switch Applicable cylinders ● Knock cylinders double acting type ● Multi mount cylinders ● DYNA cylinders ● SD cylinders ● TDAφ φ 6[0.236in.] ● AMT ● ARTB ● ACY (For the intermediate stopper) ● ORKφ φ 16[0.630in.] ● RAP ● RAN ● Swing cylinders Specifications Model Item CS5T□ CS11T□ 2-lead wire Wiring type Load voltage DC5〜28V, AC85〜115V (r.m.s.) DC10〜28V Load current DC0.1〜40mA, AC2〜25mA DC5〜40mA Internal voltage drop Note 1 2.1V MAX. (At 40mA load current) 0.1V MAX. (At 40mA load current) 0mA Leakage current 1ms MAX. Response time 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Insulation resistance Dielectric strength AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) AC1000V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 2 294.2m/s2 [30G] (Non-repeated shock) Vibration resistance Note 2 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 2750±250Hz IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection − Operation indicator When ON: Red LED indicator lights up Lead wire Note 3 PVC 0.2SQ×2-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range Contact protection Required (See contact protection on p.1566.) Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit CS5T□ CS11T□ LED indicator Brown Brown (+) Blue Blue (−) Dimensions (mm) CS5T□ CS11T□ Model marking surface 8 (10) Maximum sensing location (Cylinder mounting surface) (23) (60) R φ3 φ3 4 3.6 3.6 4 (1.5) 4 Model marking surface Indicator lamp (1.5) 4 (10) 26 (10) Maximum sensing location (Cylinder mounting surface) (60) R Products compliant with the EMC Directive ZC201□, ZC205□ Reed Switch Type Sensor Switch Applicable cylinders ●Pen cylinders Specifications Model Item ZC201□ ZC205□ 2-lead wire Wiring type Load voltage DC5〜28V, AC85〜115V (r.m.s.) DC10〜28V Load current DC0.1〜40mA, AC2〜25mA DC5〜40mA Internal voltage dropNote 1 2.1V MAX. (At 40mA load current) Note1 0.1V MAX. (At 40mA load current) 0mA Leakage current 1ms MAX. Response time 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Insulation resistance Dielectric strength AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) AC1000V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistanceNote 2 294.2m/s2 [30G] (Non-repeated shock) Vibration resistanceNote 2 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 2750±250Hz IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection − Operation indicator When ON: Red LED indicator lights up Lead wireNote 3 PCCV 0.2SQ×2-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range Contact protection Required (See contact protection on p.1566.) Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit ZC201□ ZC205□ LED indicator Brown Brown (+) Blue Blue (−) Dimensions (mm) ZC201□ ZC205□ Model marking surface (1.5) (10) Maximum sensing location (Cylinder mounting surface) (8) 23 φ3 (1.5) φ3 □4 Model marking surface Indicator lamp (60) R □4 (10) 26 (10) Maximum sensing location (Cylinder mounting surface) (60) R Products compliant with the EMC Directive CS3M□, 4M□, 5M□ Reed Switch Type Sensor Switch Applicable cylinders ● Slim cylinders ● Twinport cylinders ● GA ● ORC ● ORCA ● ORGA ● ORK Note ● MRG ● RAK ● Swing cylinders ● Twist cylinders Note: Excluding φ16 [0.630in.]. Specifications Model Item CS3M□ CS4M□ CS5M□ 2-lead wire Wiring type DC10〜30V Load voltage Load current AC85〜230V (r.m.s.) 10〜50mANote 1 Internal voltage drop Note 2 Note 1 10〜50mA(AC85〜115V) 5〜15mA(AC115〜230V)Note 1 2.5V MAX. (At 50mA load current) DC10〜30V AC85〜115V (r.m.s.) DC3〜30V AC85〜115V (r.m.s.) 5〜25mANote 1 5〜20mANote 1 0.1〜60mA 2〜25mA 2.2V MAX. (At 25mA load current) Leakage current 0.2V MAX. (At 60mA load current) 0mA Response time 1ms MAX. Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end ) Dielectric strength AC2200V (50/60Hz) in 1 minute (Between case and lead wire end) AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistanceNote 3 294.2m/s2 [30G] (Non-repeated shock) Vibration resistanceNote 3 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 5000±400Hz Operation indicator − When ON: Red LED indicator lights up Lead wireNote4 PVC 0.2SQ×2-lead×R Ambient temperature 0〜60°C [32〜140°F] Storage temperature range −10〜70°C [14〜158°F] Contact protection Required (See contact protection on p.1566.) Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. Ta=37°C [98.6°F] 2. The internal voltage drop depends on load current. 3. Measured by Koganei test standard. 4. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit CS3M□ CS4M□ CS5M□ Brown (+) Brown (+) Brown Blue (−) Blue (−) Blue The polarity is for DC. The polarity is for DC. Dimensions (mm) CS5M□ Indicator lamp 22 Maximum sensing location (Cylinder mounting surface) R (8) (60) φ3.4 0.5 7.3 (11) 7 10 0.5 7 7.3 10 φ3.4 7 7 CS3M□, CS4M□ (11) 22 Maximum sensing location (Cylinder mounting surface) R (8) (60) Products compliant with the EMC Directive CS3H□, 4H□, 5H□ Reed Switch Type Sensor Switch Applicable cylinders ● Jig cylinders J series ● TDAφ φ 10[0.394in.]〜 〜 φ 32[1.260in.] (previous type) ● Slide Units Specifications Model Item CS3H□ CS4H□ CS5H□ 2-lead wire Wiring type Load voltage DC10〜30V AC85〜115V (r.m.s.) DC10〜30V AC85〜115V (r.m.s.) DC3〜30V AC85〜115V (r.m.s.) Load current 10〜50mANote 1 10〜50mANote 1 5〜25mANote 1 5〜20mANote 1 0.1〜60mA 2〜25mA Internal voltage drop Note 2 2.5V MAX. (At 50mA load current) 2.2V MAX. (At 25mA load current) Leakage current 0mA Response time 1ms MAX. 0.2V MAX. (At 60mA load current) Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 3 294.2m/s2 [30G] (Non-repeated shock) Vibration resistance Note 3 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz) − Environmental protection Operation indicator − When ON: Red LED indicator lights up Lead wire Note 3 PCCV 0.2SQ×2-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range Contact protection Required (See contact protection on p.1566.) Mass 30g [1.06oz.] (For lead wire length A: 1000mm) Notes: 1. Ta=37°C [98.6°F] 2. The internal voltage drop depends on load current. 3. Measured by Koganei test standard. 4. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit CS3H□ CS4H□ CS5H□ Brown (+) Brown Blue (−) Blue (−) Blue The polarity is for DC. The polarity is for DC. Brown (+) Dimensions (mm) Indicator lamp (CS5H□ is not included.) 9 10 1 2 R 8.5 7 CS3H□, CS4H□, CS5H□ Maximum sensing location (8) 22 Products compliant with the EMC Directive ZC301□, ZC305□ Reed Switch Type Sensor Switch Applicable cylinders ● AGTB ● AGTC ● ORCJ ● MRC Specifications Model Item ZC301□ ZC305□ Wiring type 2-lead wire Load voltage DC5〜28V AC85〜115V (r.m.s.) Load current 0.1〜40mA 2〜25mA Internal voltage drop Note 1 DC10〜28V 5〜40mA 0.1V MAX. (At 40mA load current) 2.1V MAX. (At 40mA load current) Leakage current 0mA Response time 1ms MAX. 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Insulation resistance Dielectric strength AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) AC1000V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 2 294.2m/s2 [30G] (Non-repeated shock) Vibration resistance Note 2 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 2750±250Hz IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection − Operation indicator When ON: Red LED indicator lights up Lead wire Note 3 PCCV 0.2SQ×2-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range Contact protection Required (See contact protection on p.1566.) Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit ZC301□ ZC305□ LED indicator Brown Brown (+) Blue Blue (−) Dimensions (mm) ZC301□ ZC305□ Model marking surface Model marking surface Indicator lamp (1.5) (1.5) SUS plate 4 1 (8) φ3 φ3 4 4 SUS plate (10) Maximum sensing location (23) (60) R 4 1 (10) 26 (8) Maximum sensing location (60) R Products compliant with the EMC Directive ZC601□, ZC605□ Reed Switch Type Sensor Switch Applicable cylinders ●Axis cylinders Specifications Model Item ZC601□ ZC605□ Wiring type 2-lead wire Load voltage DC5〜28V AC85〜115V (r.m.s.) DC10〜28V Load current DC0.1〜40mA AC2〜25mA DC5〜40mA Internal voltage drop Note 1 0.1V MAX. (At 40mA load current) 2.1V MAX. (At 40mA load current) 0mA Leakage current 1ms MAX. Response time 100MΩ MIN.(At DC500V Megger, between case and lead wire end) Insulation resistance Dielectric strength AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) AC1000V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 2 294.2m/s2 [30G] (Non-repeated shock) Vibration resistance Note 2 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 2750±250Hz IP67 (IEC standard), JIS C0920 (Water-proof type) Environmental protection − Operation indicator When ON: Red LED indicator lights up Lead wire Note 3 PCCV 0.2SQ×2-lead×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range Contact protection Required (See contact protection on p.1566.) Mass 20g [0.71oz.] (For lead wire length A: 1000mm) Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit ZC601□ ZC605□ LED indicator Brown Brown (+) Blue Blue (−) Dimensions (mm) ZC601□ ZC605□ Indicator lamp Model marking surface 4 4 Model marking surface 3.5 3.5 16.5 (16.5) 33 φ3 φ3 1.5 1.5 16.5 (8) Maximum sensing location (Cylinder mounting surface) (60) R (16.5) 33 (8) Maximum sensing location (Cylinder mounting surface) (60) R Products compliant with the EMC Directive ZE101□, 102□, 201□, 202□ Reed Switch Type Sensor Switch Applicable cylinders ● Jig cylinders C series ● Jig cylinders JC series ● Mini guide sliders ● Jig cylinders with guides ● Twin rod cylinders B series ● Rod sliders ● Multi sliders ● WT ● ACY Note ● ACZ Note ● WS ● Flat rodless cylinders ●ORV Note ●ORS Note ●MRS Note ●ORW, MRW ●RAG ●RAT ●DJ cylinders Note: Only the horizontal lead wire type is available. Specifications Model Item ZE101□ ZE102□ ZE201□ ZE202□ 2-lead wire Wiring type Horizontal Lead wire direction Vertical Load voltage DC5〜28V, AC85〜115V DC10〜28V, AC85〜115V DC5〜28V, AC85〜115V DC10〜28V, AC85〜115V Load current DC40mA MAX., AC20mA MAX. DC5〜40mA, AC5〜20mA DC40mA MAX., AC20mA MAX. DC5〜40mA, AC5〜20mA Internal voltage dropNote 1 0.1V MAX. (At DC40mA load current) 3.0V MAX. 0.1V MAX. (At DC40mA load current) 3.0V MAX. 0mA Leakage current 1ms MAX. Response time Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC1500V (50/60Hz) in 1 minute (Between case and lead wire end) 294m/s2 [30G] (Non-repeated shock) Shock resistanceNote 2 2 Note 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 2750±250Hz Vibration resistance Environmental protection IP67 (IEC standard), JIS C0920 (Water-proof type) Operation indicator None None When ON: Red LED indicator lights up Lead wireNote 3 When ON: Red LED indicator lights up PCCV 0.2SQ×2-lead (Brown and blue)×R 0〜60°C [32〜140°F] Ambient temperature −10〜70°C [14〜158°F] Storage temperature range Required (See contact protection on p.1566.) Contact protection 15g [0.53oz.] (For lead wire length A: 1000mm), 35g [1.23oz.] (For lead wire length B: 3000mm ) Mass Notes: 1. The internal voltage drop depends on load current. 2. Measured by Koganei test standard. 3. Lead wire length R: A; 1000mm [39in.], B; 3000mm [118in.] Internal Circuit ZE102□, ZE202□ ZE101□, ZE201□ Brown Brown (+) Blue Blue (−) Dimensions (mm) ●Horizontal lead wire ZE101□, ZE102□ ●Vertical lead wire ZE201□, ZE202□ M2.5 Slotted setscrew M2.5 Slotted setscrew Indicator lamp (For ZE102□) (8) φ2.6 R 4.6 (8) Maximum sensing location R 11.5 22.5 φ2.6 60±10 4.5 (10) 60±10 4 4 Indicator lamp (For ZE202□) (10) Maximum sensing location 22 CS2F, 3F, 4F, 5F Reed Switch Type Sensor Switch Applicable cylinders ● Slim cylinders Note ● DYNA cylinders ● GA ● Swing cylinders Note: Excluding Slim block cylinder φ16 [0.630in.] Specifications Model Item Wiring type CS2F CS3F CS4F CS5F 2-lead wire Load voltage AC85〜230V (r.m.s) DC5〜30V DC5〜30V DC3〜30V Load current 2〜200mA 10〜46mANote 1 5〜25mANote 1 0.1〜80mA 0.1V MAX. (At 200mA load current) 3V MAX. (At 46mA load current) Note 2 2.8V MAX. (At 25mA load current) Note 2 Internal voltage drop Leakage current 1mA MAX. (AC100V) 2mA MAX. (AC200V) Response time 2ms MAX. 0mA 1.2ms MAX. Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 3 Vibration resistance 0.1V MAX. (At 80mA load current) 294.2m/s2 [30G] (Non-repeated shock) Note 3 2 88.3m/s [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 5000±400Hz − Environmental protection Operation indicator − When ON: Red LED indicator lights up When ON: Red neon lamp turns off With DIN connector (Cabtyre outer diameter φ6.5 [0.256in.] MAX.,Wireφ1.25SQ MAX.) Method of wiring Ambient temperature 0〜60°C [32〜140°F] −10〜70°C [14〜158°F] Storage temperature range Contact protection Not required Required (See contact protection on p.1566.) Mass 40g [1.41oz.] Notes: 1. Ta=37°C [98.6°F] 2. The internal voltage drop depends on load current. 3. Measured by Koganei test standard. Internal Circuit CS2F CS3F CS4F CS5F q(+) q(+) q(+) q w(−) w(−) w(−) w Z The numbers in circle show the terminal numbers of the F type connector. Dimensions (mm) CS5F 13 Indicator lamp 13 CS2F, CS3F, CS4F 24 28 28 □15 12 Maximum sensing location R10 39 19 7 12 7 12 19 4 4 29 29 φ6.5 12 φ6.5 24 □15 Maximum sensing location (16) (15) R10 39 (16) (15) CS2B, 3B, 4B, 5B Reed Switch Type Sensor Switch Specifications Model Item CS2B CS3B CS4B CS5B 2-lead wire Wiring type Load voltage AC85〜230V (r.m.s) DC5〜30V DC5〜30V DC3〜30V Load current 2〜200mA 10〜46mA Note 1 5〜25mA Note 1 0.1〜80mA 0.1V MAX. (At 200mA load current) 3V MAX. (At 46mA load current) Note 2 2.8V MAX. (At 25mA load current) Note 2 0.1V MAX. (At 80mA load current) Internal voltage drop Leakage current 1mA MAX. (AC100V) 2mA MAX. (AC200V) Response time 2ms MAX. 0mA 1.2ms MAX. Insulation resistance 100MΩ MIN. (At DC500V Megger, between case and lead wire end) Dielectric strength AC500V (50/60Hz) in 1 minute (Between case and lead wire end) Shock resistance Note 3 294.2m/s2 [30G] (Non-repeated shock) Vibration resistance Note 3 88.3m/s2 [9G] (Total amplitude 1.5mm [0.06in.], 10〜55Hz), Resonance frequency 2200±300Hz − Environmental protection Operation indicator − When ON: Red LED indicator lights up When ON: Red neon lamp turns off Lead wire VCT 0.3SQ×2-lead×1500mm [59in.] Ambient temperature 0〜60°C [32〜140°F] −10〜70°C [14〜158°F] Storage temperature range Contact protection Not required Required (See contact protection on p.1566.) Mass 60g [2.12oz.] Notes: 1. Ta=37°C [98.6°F] 2. The internal voltage drop depends on load current. 3. Measured by Koganei test standard. Internal Circuit CS2B CS3B CS4B CS5B White Red (+) Red (+) White Black Black (−) Black (−) Black Z Dimensions (mm) CS2B, CS3B, CS4B 1500 (5) (10) 4 8 (5) 18 18 4.8 10.6 (16) 1500 35 (10) 4.8 Indicator lamp 2 10 10.6 35 4 8 CS5B (16) Maximum sensing location (Cylinder mounting surface) Maximum sensing location (Cylinder mounting surface) ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Reed Switch Type
- 2-lead wire
- DC5〜28V, AC85〜115V (r.m.s.) load voltage
- DC0.1〜40mA, AC2〜25mA load current
- Pen cylinders
- IP67 environmental protection
Frequently asked questions
It is a Reed Switch Type Sensor Switch.
It has a load voltage of DC5〜28V, AC85〜115V (r.m.s.)
The load current is DC0.1〜40mA, AC2〜25mA.
It has an IP67 environmental protection rating.
It is designed for Pen cylinders.