KTR MONITEX BT Operating/Mounting Instructions
KTR MONITEX BT is a flexible jaw coupling with integrated measurement of torque and speed. It features a coupling hub with integrated measurement electronics and an inductive energy transducer. The measuring data is transmitted wirelessly to a mobile device or PC, and can also be viewed on the coupling's rotating display. Additionally, a digital-to-analog converter is optionally available, providing the data as analog output values. This robust coupling is suitable for a variety of applications requiring accurate torque and speed measurement.
PDF
Download
Document
Advertisement
Advertisement
MONITEX® BT measuring hub Operating/Assembly instructions KTR-N Sheet: Edition: 49110 EN 1 of 21 3 MONITEX® BT Flexible jaw coupling with integrated measurement of torque and speed MONITEX® BT is a flexible jaw coupling with integrated torque and speed measurement. It is composed of a coupling hub with integrated measurement electronics and an inductive energy transducer (inductive head). The measuring data are contactlessly transmitted to a mobile device or PC and can be additionally read via a display on the coupling with rotation. A digital-to-analog converter is optionally available providing the data as analog output values. KTR PC software 1 KTR mobile apps Display DAC analog output IoT Edge Device 1) 1) Please contact KTR for further details about „IoT Edge Device“. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions KTR-N Sheet: Edition: 49110 EN 2 of 21 3 Table of contents 1 Technical data 3 2 Advice 5 2.1 2.2 2.3 2.4 2.5 5 5 5 6 6 3 4 General advice Safety and advice symbols General hazard warnings Intended use Reference to EC Machinery Directive 2006/42/EC Storage, transport and packaging 6 3.1 3.2 6 6 Storage Transport and packaging Assembly 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 5 6 7 Mounting instructions of the MONITEX® BT measuring hub Components of the MONITEX® BT measuring coupling Technical description Advice for finish bore of ROTEX®/ROTEX® GS hub resp. coupling flange N Assembly of the coupling (general) Assembly of the hub resp. coupling flange N and the MONITEX® BT measuring hub Displacements - alignment of the ROTEX® GS couplings Assembly of the MONITEX® BT inductive head (energy transducer) 7 7 8 8 9 9 10 11 Start-up 12 5.1 5.2 12 12 Electrical connections Operation DAC analog output 13 6.1 6.2 13 14 DAC connections and technical data DAC operation 7 Disposal 15 8 Maintenance and service 15 9 Services, customer service addresses 15 10 Description of the MONITEX® BT app 16 10.1 System requirements 10.2 Linking of hardware 10.3 Measuring mode 10.4 Settings 10.5 Saving of measuring data 16 16 17 18 19 Declaration of conformity 20 11.1 EU Declaration of conformity 11.2 UK Declaration of conformity 20 21 11 Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 KTR-N Sheet: Edition: MONITEX® BT measuring hub Operating/Assembly instructions 1 49110 EN 3 of 21 3 Technical data MONITEX® BT measuring hub Illustration 1: MONITEX® BT measuring hub Table 1: Dimensions MONITEX® BT size 28/200 42/800 DA 112.4 138.4 DH 65 95 DN 90 120 D4 54 80 Dimensions in mm D5 44 65 L5 1.5 1.5 L7 28 33 N 10 10 Zx M 8x M6 12x M8 Table 2: Technical data Coupling size of MONITEX® BT 28/200 42/800 Electrical data Supply voltage DC in V Max. current consumption in mA 24 ±4 200 Torque measurement Measuring range - rated torque TKN in Nm -200 … +200 -800 … +800 Measuring frequency of PC software in Hz 500 Measuring frequency of mobile device (Android, iOS) in Hz 60 Error in linearity in % 1) ±0.25 1) Influence of temperature in %/10K 0.05 1) Nominal temperature range in °C 0 - 55 Speed measurement Measuring range in rpm 30 - 3500 Inaccuracy in rpm 1 Measuring frequency of PC software in Hz 5 Measuring frequency of mobile device (Android, iOS) in Hz 3 Display Number of digits of torque 3 + 1 decimal places + sign Number of digits of speed 4 300 Switch-on threshold in rpm Mechanical data Static load limit TKmax. in % 1) 150 150 Breaking load TK break in % 1) 300 300 Max. bending torque in Nm 22.0 86.0 Max. radial force in N 250 700 Max. axial force in kN 8.0 20.0 Weight in kg 0.84 1.72 Torsion spring stiffness CT in Nm/rad 46000 194000 Torsion angle with TKN in degrees 0.25 0.24 Mass moment of inertia in kgmm2 765.0 2690.0 Max. speed in rpm 3500 1) Referring to rated torque TKN (different TKN figures of spider, see table 3) Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 KTR-N Sheet: Edition: MONITEX® BT measuring hub Operating/Assembly instructions 1 49110 EN 4 of 21 3 Technical data MONITEX® BT measuring coupling in combination with a coupling flange Illustration 2: MONITEX® BT measuring coupling with coupling flange Table 3: Dimensions and technical data MONITEX® BT size Size 28/200 28 42/800 42 ROTEX® GS Spider GS Rated torque TKN shore hardness in Nm 92 ShA 95 98 ShA 160 57 ShD 178 64 ShD 200 72 ShD 260 98 ShA 450 57 ShD 495 64 ShD 560 72 ShD 1) 728 Dimensions 2) in mm Max. finish bore D D1 DA DH DBSE DN DN2 35 30 112.4 65 54.5 90 42 55 45 138.4 95 65.0 120 62 Dimensions 2) in mm MONITEX® BT size D4 L L1 L2 L5 L7 E B1 S 28/200 42/800 54 80 125 166 35 50 35.5 51.0 35 50 28 33 20 26 15 20 2.5 3.0 Cap screws DIN EN ISO 4762 Number Z M TA in Nm 8 M6 17 12 M8 41 1) When using the 72 ShD spider, we recommend to use hubs made of steel. 2) For dimensions G, G1, T and T1 see table 4 Please note that with the use of the 72 ShD spider of ROTEX® GS size 28 the max. permissible torque of MONITEX® BT (see table 2) must not be exceeded. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 2 Advice 2.1 General advice KTR-N Sheet: Edition: 49110 EN 5 of 21 3 Read carefully through these operating/assembly instructions before you start up the measuring coupling. Pay special attention to the safety instructions! The operating/assembly instructions are part of your product. Please store them carefully and close to the measuring coupling. The copyright for these operating/assembly instructions remains with KTR. 2.2 Safety and advice symbols Warning of potentially explosive atmospheres This symbol indicates notes which may contribute to preventing bodily injuries or serious bodily injuries that may result in death caused by explosion. Warning of personal injury This symbol indicates notes which may contribute to preventing bodily injuries or serious bodily injuries that may result in death. Warning of product damages This symbol indicates notes which may contribute to preventing material or machine damage. Warning of electromagnetic field This symbol indicates notes which may contribute to preventing injuries resulting from electromagnetic radiation. General advice This symbol indicates notes which may contribute to preventing adverse results or conditions. 2.3 General hazard warnings STOP ! STOP With assembly, operation and maintenance of the measuring coupling it has to be made sure that the entire drive train is secured against accidental switch-on. You may be seriously hurt by rotating parts. Make absolutely sure to read through and observe the following safety indications. • All operations on and with the measuring coupling have to be performed taking into account "safety first". • Make sure to switch off the power pack before you perform your work on the measuring coupling. • Secure the power pack against accidental switch-on, e. g. by providing warning signs at the place of switch-on or removing the fuse for current supply. • The front side of the MONITEX® BT inductive head must not have any contact with metallic surfaces when switched on. Metallic surfaces reduce the transmission performance and may damage the electronics assembly with permanent contact. The minimum distance to metallic surfaces should not fall below 10 mm. • Do not reach into the operating area of the measuring coupling as long as it is in operation. • Secure the rotating components of the measuring coupling against accidental contact. Provide for the necessary protection devices and covers. The device must not be used by persons with a pacemaker, since the energy needed for the operation is transmitted by an inductive head. We cannot rule out that the emerging electromagnetic radiation may generate malfunctions or damages on vital medical devices. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 2 Advice 2.4 Intended use KTR-N Sheet: Edition: 49110 EN 6 of 21 3 You may only assemble, operate and maintain the measuring coupling if you • have carefully read through the operating/assembly instructions and understood them • are technically qualified and specifically trained (e. g. safety, environment, logistics) • are authorized by your company The measuring coupling may only be used in accordance with the technical data (see chapter 1). Unauthorized modifications on the measuring coupling design are not admissible. We will not assume liability for any damage that may arise. In the interest of further development we reserve the right for technical modifications. The MONITEX® BT measuring hub described in here corresponds to the state of the art at the time of printing of these operating/assembly instructions. 2.5 Reference to EC Machinery Directive 2006/42/EC The measuring equipment supplied by KTR should be considered as components, not machines or partly completed machines according to EC Machinery Directive 2006/42/EC. Consequently KTR does not have to issue a declaration of incorporation. For details about safe assembly, start-up and safe operation refer to the present operating/assembly instructions considering the warnings. 3 Storage, transport and packaging 3.1 Storage ! 3.2 ! Humid storage rooms are not suitable. Make sure that condensation is not generated. The best relative air humidity is less than 65 %. Transport and packaging In order to avoid any injuries and any kind of damage always make use of proper transport and lifting equipment. The measuring couplings are packed differently each depending on size, number and kind of transport. Unless otherwise contractually agreed, packaging will follow the in-house packaging specifications of KTR. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 4 Assembly 4.1 Mounting instructions of the MONITEX® BT measuring hub ! KTR-N Sheet: Edition: 49110 EN 7 of 21 3 Opening the housing is not required and may cause damage to the measuring shaft. • Protection class The MONITEX® BT measuring hub complies with protection class IP51 acc. to DIN EN 60529. • Maintenance The MONITEX® BT measuring hub is maintenance-free. Lubrication or cleaning is not necessary. • Calibration The transducer is calibrated when supplied. We recommend an annual inspection of the calibration. The mounting position of MONITEX® BT is variable. The measurement system can be mounted both horizontally and vertically. Vertical assembly may require a support in the bottom coupling hub. 4.2 Components of the MONITEX® BT measuring coupling Components of the MONITEX® BT measuring coupling Component 1 2 3 1) 4 2) 5 2) 6 2) 7 2) 8 2) Quantity 1 1 1 1 1 1 see table 3 2 Subassembly MONITEX® BT measuring hub MONITEX® BT inductive head (inductive current transmission) MONITEX® BT connection cable ROTEX®/ROTEX® GS hub ROTEX® GS spider ROTEX® coupling flange N Cap screws DIN EN ISO 4762 - 12.9 Setscrew DIN EN ISO 4029 1) not graphically displayed in illustration 3 2) Optionally available Illustration 3: MONITEX® BT measuring coupling Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 KTR-N Sheet: Edition: MONITEX® BT measuring hub Operating/Assembly instructions 4 Assembly 4.3 Technical description 49110 EN 8 of 21 3 1. General description The MONITEX® BT measuring hub has an integrated measuring system for measuring the current torque and speed. These data can be directly received by bluetooth compatible devices, e. g. mobile phones or tablets. Free apps for Android and iOS are available in the app stores. Those PCs that are able to receive data via bluetooth are also supported. The PC software can be downloaded via the KTR homepage. 4.4 STOP Please consider the respective system requirements of your device (see chapter 10.1). Advice for finish bore of ROTEX®/ROTEX® GS hub resp. coupling flange N The maximum permissible bore diameters D (see chapter 1 - technical data) must not be exceeded. If these figures are disregarded, the coupling may tear. Rotating particles may cause danger to life. • Bores machined or remachined by the customer have to observe concentricity respectively axial runout (see illustration 4). • Make absolutely sure to observe the figures for ØD. • Carefully align the hubs when the finish bores are drilled. • Provide for a setscrew according to DIN EN ISO 4029 with a cup point or an end plate to axially fasten the hubs. Illustration 4: Concentricity and axial runout ! The customer bears the sole responsibility for all machining processes performed subsequently on unbored or pilot bored as well as finish machined coupling components and spare parts. KTR does not assume any warranty claims resulting from insufficient remachining. Table 4: Setscrew DIN EN ISO 4029 Size Dimension G, G1 in mm Dimension T, T1 in mm Tightening torque TA in Nm Please observe protection note ISO 16016. Drawn: Verified: 28 M8 15 10 2024-02-07 Pz/Da 2024-02-08 Pz 42 M8 20 10 Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 4 Assembly 4.5 Assembly of the coupling (general) KTR-N Sheet: Edition: 49110 EN 9 of 21 3 We recommend to inspect bores, shaft, keyway and feather key for dimensional accuracy before assembly. Heating the hub or coupling flange lightly (approx. 80 °C) allows for an easier mounting on the shaft. STOP Touching the heated components causes burns. Please wear safety gloves. ! With the assembly make sure that the distance dimension E or DBSE (see table 3) is observed to allow for axial clearance of the spider when in operation. Disregarding this advice may cause damage to the coupling. 4.6 Assembly of the hub resp. coupling flange N and the MONITEX® BT measuring hub • Mount the coupling flange N on the shaft of the driving side and the hub on the shaft of the driven side (see illustration 5). • The internal sides of the components must be flush with the front sides of the shafts. • Fasten the hub and coupling flange by tightening the setscrews DIN EN ISO 4029 with a cup point (tightening torques see table 4). Illustration 5: Assembly of hub resp. coupling flange N • Insert the MONITEX® BT measuring hub in front of the coupling flange (see illustration 6). • Hand-tighten the components first. • Tighten the screws at the tightening torques TA specified in table 3 by means of a suitable torque key. Illustration 6: Assembly of the MONITEX® BT measuring hub • Insert the spider in the cam section of the hub (see illustration 7). • Shift the power packs in axial direction until the distance dimension E or DBSE is achieved (see illustration 2 and table 3). • Centre the spider between the hub and the coupling flange N and check the dimension E and S (see illustration 2 and table 3). Illustration 7: Assembly of spider ! Having started up the measuring coupling, the wear of the spider has to be inspected at regular maintenance intervals and the spider has to be replaced, if necessary. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 KTR-N Sheet: Edition: MONITEX® BT measuring hub Operating/Assembly instructions 4 Assembly 4.7 Displacements - alignment of the ROTEX® GS couplings 49110 EN 10 of 21 3 In order to ensure a long service life of the components, the shaft ends have to be accurately aligned. Please absolutely observe the displacement figures specified (see table 5). If the figures are exceeded, the measuring coupling will be damaged. The more accurate the alignment of the coupling, the longer is its service life. ! Please note: • The displacement figures specified in table 5 are maximum figures which must not arise in parallel. If axial, radial and angular displacement arises at the same time, these values must be reduced (see illustration 9). Inspect with a dial gauge, ruler or feeler gauge whether the permissible displacement figures specified in table 5 can be observed. Axial displacements Radial displacements Lmax = L +/- Ka Angular displacements Kw in mm = L1max - L1min Illustration 8: Displacements Examples of the displacement combinations specified in illustration 9: Example 1: Kr = 30 % Kw = 70 % Illustration 9: Combinations of displacement Example 2: Kr = 60 % Kw = 40 % Ktotal = Kr + Kw 100 % Table 5: Displacement figures MONITEX® BT size ROTEX® GS size 28/200 28 42/800 42 Please observe protection note ISO 16016. Spider GS shore hardness 92 ShA 98 ShA 57 ShD 64 ShD 72 ShD 98 ShA 57 ShD 64 ShD 72 ShD Drawn: Verified: Max. axial displacement Ka in mm +1.5 / -0.7 +2.0 / -1.0 2024-02-07 Pz/Da 2024-02-08 Pz Max. radial displacement Kr in mm 0.15 0.11 0.09 0.08 0.05 0.14 0.12 0.10 0.07 Replacing: Replaced by: Max. angular displacement Kw in degree 1.00 0.90 0.85 0.80 0.70 0.90 0.85 0.80 0.70 KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions KTR-N Sheet: Edition: 4 Assembly 4.8 Assembly of the MONITEX® BT inductive head (energy transducer) 49110 EN 11 of 21 3 a) Fastening of inductive head Mounting of the inductive head is made by fastening the mounting profile fitted on the back side to a suitable fixture. Illustration 10: Dimensions of inductive head b) Arrangement of inductive head The inductive head (energy transducer) is mounted radially beside the measuring hub inductively providing the rotating unit with energy. The following items should be observed: • The maximum distance is 10 mm, the maximum axial displacement from the centre is ±2.5 mm. • The orientation is directed vertically to the axis of rotation. • The front side of the transducer is directed to the external surface of the rotor. Illustration 11: Correct positioning of the inductive head Please observe protection note ISO 16016. Drawn: Verified: Illustration 12: Incorrect positioning of the inductive head 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 5 Start-up 5.1 Electrical connections KTR-N Sheet: Edition: 49110 EN 12 of 21 3 a) Connection cable The connection cable has a four-pole M8 circular connector that can be screwed together with the mating connector of the inductive head (see illustration 13). Table 6 shows the pin assignment. Table 6: Pin assignment Colour White Black Blue Brown Connection Operating voltage +24 V Operating voltage GND Not assigned Not assigned Illustration 13: Connector plug b) Operating voltage 24 V The supply voltage is 24 V ±4 V direct current voltage (DC). The current consumption is 200 mA at the maximum. c) Ground connection To avoid interferences, the mounting aid resp. the mounting bracket of the inductive head should be grounded (see illustration 14). Illustration 14: Grounding of inductive head 5.2 Operation a) Switching on Having positioned and connected the inductive head, the system can be switched on via the on/off switch. The orange function LED on the inductive head lights up. The LEDs integrated in the rotor light up one after another from inside to outside and indicate starting of the measurement. b) Bluetooth signal Having switched on the measuring hub the bluetooth signal is available for a mobile device or a PC. The bluetooth device resp. the PC can now be coupled with MONITEX® BT. Having opened the app resp.the PC software, the torque and speed signals are available. c) Display With speeds exceeding 300 rpm the rotating display switches on. The measurement values for torque and speed can be read out directly on the sensor. If the distance of the inductive head to the rotor is too big, the display shows the hint "distance" alerting about a termination of energy supply. In this case the distance between the inductive head and the rotor must be investigated and the alignment must be inspected. The centre of the display is 90 degrees at the right of the position of the inductive head. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 6 KTR-N Sheet: Edition: 49110 EN 13 of 21 3 DAC analog output MONITEX® BT DAC is an optionally available digital-to analog-converter. It automatically connects to a MONITEX® BT coupling and converts the measured values torque and speed to analog signals. 6.1 DAC connections and technical data 1 - Power supply input 2 - Voltage output of speed (0 - 10 V) 3 - Voltage output of torque (-10 … 10 V) 4 - Current output of torque (4 … 20 mA) 5 - Current output of speed (4 … 20 mA) 6 - Push button T1 7 - Status LED Connectors Würth Elektronik, Order No.: 691351500004 Connector type signal outputs Würth Elektronik, Order No.: 691351500002 Connector type 24 V DC power supply Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 KTR-N Sheet: Edition: MONITEX® BT measuring hub Operating/Assembly instructions 6 DAC analog output 6.1 DAC connections and technical data 49110 EN 14 of 21 3 Table 7: Technical data of DAC Electrical data Power supply DC in V Max. current consumption in mA 24 ± 4 < 100 Torque outputs -10 … +10 4 … 20 500 200 Voltage output in V Current output in mA Converter frequency in Hz Bandwidth in Hz Speed outputs 0 … 10 4 … 20 5 3.5 Voltage output in V Current output in mA Converter frequency in Hz Bandwidth in Hz Resistance values Output resistance of voltage output in ohm Maximum current loop resistance in ohm 1000 560 Inaccuracies of converter Voltage outputs in % 1) Current outputs in % 1) 0.05 0.1 Mechanical data Dimensions in mm (L x B x H) Weight in g 100 x 62 x 26 85 LED Status LED red = not connected green = connected 28/200 20 25 350 218.75 42/800 80 100 350 218.75 Scaling Coupling size of MONITEX® BT Voltage output torque in Nm/V Output current torque in Nm/mA Voltage output speed in rpm/V Output current speed in rpm/mA 1) Referring to upper range value 6.2 DAC operation a) DAC bluetooth connection The status LED shows the connection status: green = connected, red = not connected. During the first startup the DAC automatically connects to the next MONITEX ® BT coupling, which is not linked. The DAC memorises the connected MONITEX ® BT In the following connections the DAC will always pair with the memorised MONITEX® BT. If linking with another measuring hub is to be made, the already coupled MONITEX ® BT hub must be switched off while the new MONITEX® BT hub must be switched on. The new connection will be established when the push button T1 is pressed for > 3 seconds. The status LED flashes green for confirmation, afterwards the DAC connects to the new measuring hub. b) Auto offset If the push button T1 is pressed shortly, < 2seconds, the torque outputs of the DAC will be set to 0 Nm. The status LED flashes red once for confirming the auto offset. c) Reception error If the status LED flashes red during a connection, the bluetooth reception is poor. Reduce the distance to the measuring hub. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 7 KTR-N Sheet: Edition: 49110 EN 15 of 21 3 Disposal In respect of environmental protection we would ask you to dispose of the packaging resp. products on termination of their service life in accordance with the legal regulations resp. standards that apply. 8 Maintenance and service The MONITEX® BT is a low-maintenance torque measuring hub. We recommend to perform a visual inspection on the coupling at least once a year. Pay special condition to the condition of the spiders of the ROTEX ® GS coupling. • Since the flexible machine bearings of the driving and driven side settle during the course of load, inspect the alignment of the measuring coupling and re-align, if necessary. • The components have to be inspected for damages. • The screw connections have to be visually inspected. 9 Please consider our operating/assembly instructions KTR-N 45510 additionally when using the ROTEX® GS coupling. Services, customer service addresses If requested, we are pleased to perform the calibration of your measuring hub and other services. Contact addresses of the KTR partners for spare parts and orders can be obtained from the KTR homepage at www.ktr.com. KTR does not assume any liability or warranty for the use of spare parts and accessories which are not provided by KTR and for the damages which may incur as a result. KTR Systems GmbH Carl-Zeiss-Str. 25 D-48432 Rheine Phone: +49 5971 798-0 E-mail: [email protected] Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 10 KTR-N Sheet: Edition: 49110 EN 16 of 21 3 Description of the MONITEX® BT app 10.1 System requirements The KTR-MONITEX® BT app is available for Android and IOS in the app stores free of charge. Both versions have the same functionality. The versions of the operating systems from Android 6 and iOS 15.5 1) are supported. 1) On old devices with low processing power the performance may be affected with long measurements. MONITEX® BT Position the inductive head acc. to chapter 4.8 and switch on the power supply. An animation of the rotor display informs about the proper function. Switch-on animation Please switch to the system settings and activate the bluetooth mode. • With Apple devices you have to activate the function "allow new connections". The sensor is usually not displayed in the system menu, since linking is made by the app. • Even if the name of the sensor appears in the system menu, do not couple it at this point, but only with the app. If the sensor is coupled in the system menu, it is no longer visible for the app. Bluetooth menu 10.2 Linking of hardware Please start the app. Now the app is in the starting mode. Start screen. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 10 KTR-N Sheet: Edition: 49110 EN 17 of 21 3 Description of the MONITEX® BT app 10.2 Linking of hardware Having activated the scan button a new window is opened listing all MONITEX® BT sensors that are available. The number displayed corresponds to the last digits of the ident number of the sensor. The ident number can be found as a label on the outer edge of the coupling and in the calibration record. Please note that a sensor is not listed if it is already in connection with another device. If the sensor shall be used, its linking must be disconnected first. The maximum range may vary depending on the mounting situation. Scan function 10.3 Measuring mode Please select a sensor. The display switches into the measuring mode. Measuring is started via the button "play". The measuring data is automatically saved and can be processed later. Below the diagram a timer informs about the expired test duration. The display of the smartphone/tablet can be switched off during measuring. Measuring is continued in the background. Measuring mode The display limits comply with the measuring range of the connected sensor. The diagram can be shifted and zoomed in x and y direction. The button "reset zoom" allows to set back the display range to standard values. The curves can be shifted to the beginning of the measurement, so that incidents in the past can be analysed during the ongoing measurement as well. For that purpose simply shift the curve right as far as necessary. The button "go live" directs you to the end of the diagram again. The landscape view enlarges the respective diagram tapping the diagramme surface once. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 10 KTR-N Sheet: Edition: 49110 EN 18 of 21 3 Description of the MONITEX® BT app 10.3 Measuring mode Using the number and curve icon the current view can be switched between "number display" and "curve display". On the left side of the numerical display the current values are shown. On the right side maximum values, minimum values and average values of the ongoing measurement are continuously calculated. The period of calculation is displayed in a timer. The calculation of the extreme values starts again once the timer is reset. 10.4 Settings The gear wheel ícon refers to the menu "settings". The function "Auto offset" allows to set the torque output to 0 Nm. Limits serve for producing an alert in case if a defined range is exceeded or fallen below. The alert can be visually signalized by discolouration of the diagram background or acoustically by a warning signal. The volume can be set via the media volume in the system menu. The limits of the selected ranges are displayed in the diagram by dotted lines. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 10 KTR-N Sheet: Edition: 49110 EN 19 of 21 3 Description of the MONITEX® BT app 10.5 Saving of measuring data The measuring data is automatically saved as soon as the measurement is started via the button "play". If a measurement is finished by the stop button, the button "share" is displayed, it opens a window with possibilities to send or save thee measured data. The data format comprises a table in CSV format indicating the measuring time in s, the torque in Nm and the speed in rpm. The semicolon is used as a separator. The sampling frequency of the torque is 60 Hz. The sampling frequency of the speed signal is 3 Hz. Please observe protection note ISO 16016. Drawn: Verified: 2024-02-07 Pz/Da 2024-02-08 Pz Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 11 KTR-N Sheet: Edition: 49110 EN 20 of 21 3 Declaration of conformity 11.1 EU Declaration of conformity EU Declaration of conformity The manufacturer - KTR Systems GmbH, Carl-Zeiss-Str. 25, D-48432 Rheine - states that the MONITEX® BT measuring hub described in the present operating/assembly instructions is in accordance with the following directive: 2014/30/EU Directive of the European Parliament and European Council dated February 26. 2014 for harmonizing the legal provisions of the member states regarding electromagnetic compatibility Standards applied: EN IEC 61000-6-2: EN 61000-4-2: EN IEC 61000-4-3: EN 61000-4-4: EN 61000-4-6: EN IEC 61000-6-4: EN 55011: Rheine, Place Immunity standard for industrial environments Electrostatic discharge immunity test (ESD) Radiated, radio-frequency, electromagnetic field immunity test Electrical fast transient/burst immunity test Immunity to conducted disturbances, induced by radio-frequency fields Emission standard for industrial environments Intensity of radio interference area (class B) 2022-07-18 Date Please observe protection note ISO 16016. Drawn: Verified: i. V. Reinhard Wibbeling Engineering/R&D 2024-02-07 Pz/Da 2024-02-08 Pz i. A. Jürgen Kösters Product Manager Replacing: Replaced by: KTR-N dated 2023-06-20 MONITEX® BT measuring hub Operating/Assembly instructions 11 KTR-N Sheet: Edition: 49110 EN 21 of 21 3 Declaration of conformity 11.2 UK Declaration of conformity UK Declaration of conformity The manufacturer - KTR Systems GmbH, Carl-Zeiss-Str. 25, D-48432 Rheine - states that the MONITEX® BT measuring hub described in the present operating/assembly instructions is in accordance with the following directive: SI 2016/1091 Electromagnetic Compatibility Regulations 2016 Standards applied: EN IEC 61000-6-2: EN 61000-4-2: EN IEC 61000-4-3: EN 61000-4-4: EN 61000-4-6: EN IEC 61000-6-4: EN 55011: Immunity standard for industrial environments Electrostatic discharge immunity test (ESD) Radiated, radio-frequency, electromagnetic field immunity test Electrical fast transient/burst immunity test Immunity to conducted disturbances, induced by radio-frequency fields Emission standard for industrial environments Intensity of radio interference area (class B) Authorised representative: KTR U.K. Ltd. Robert House Unit 7, Acorn Business Park Woodseats Close Sheffield United Kingdom, S8 0TB Year of UKCA marking: 2022 Rheine, Place 2022-07-18 Date Please observe protection note ISO 16016. Drawn: Verified: i. V. Reinhard Wibbeling Engineering/R&D 2024-02-07 Pz/Da 2024-02-08 Pz i. A. Jürgen Kösters Product Manager Replacing: Replaced by: KTR-N dated 2023-06-20 ">
Advertisement
Key features
- Integrated torque & speed measurement
- Wireless data transmission
- Rotating display
- Optional DAC output
- IP51 protection class
- Maintenance-free
Frequently asked questions
The MONITEX BT uses Bluetooth to wirelessly transmit data to a compatible mobile device or PC.
No, the MONITEX BT is maintenance-free, requiring no lubrication or cleaning.
The maximum speed that the MONITEX BT can measure is 3500 rpm.