XPR SC24000 Owner's Manual
xpr SC24000 is a standalone access control unit designed for two doors with features like programmable readers, 4000 user capacity, anti-passback option, and adjustable door relay time. It can be used for secure access control in various applications, including offices, buildings, and other facilities.
PDF
Document
Advertisement
Advertisement
SC24000 EN 2 Door standalone access control unit CONTENTS: 1. Features .................................................................................................. 1 2.Mounting .................................................................................................. 2 3.Typical two door application .......................................................... ............. 2 4.Terminal block description ....................................................................... 3 5. DIP switch settings .................................................................................... 3 6. Wiring ................................................................................................. 4 7. Factory reset .................................................................................... 4 8. Programming .................................................................................... 5 9. Anti Pass Back .................................................................................... 7 10. Examples ................................................................................................. 8 11. Programming with Keypad (LCSP, VKP, INOX, MTPAD-M) ............. ... 8 12. Programming in double security mode (LCSP) ........................................... 9 1. FEATURES Electrical Characteristics Operating Voltage: Current consumption : Door Relays: Output Relays: 8 to 15V DC max. 180 mA (without readers) 250 VAC/4A 250 VAC/4A Environmental Characteristics Operating Temperatures : Operating Humidity : 0ºC to +50ºC 0 to 95% (non-condensing) PCB Dimensions (mm) 102 L x 86 W 61 mm • Programmable trough readers • 4000 users (Cards) • 2 reader inputs (Auto detect Wiegand26 / Wiegand34) • 2 door relays (2 x 250VAC/4A) • 2 door sensor inputs • 2 push button inputs • 2 Alarm relays: Output 1 (door forced alarm), Output 2 (door left open alarm) • Programming done with Master1&2, Delete, Reset APB, Master 1 and Master 2 card • Adjustable Door relay time (1 - 250sec, or ON/OFF(toggle) mode) • Anti Pass Back option • Normal wiegand mode (card only) and LCSP mode (card and PIN code) on any reader • Shadow delete card - per user or per group of users • Max. Users in 1 groups: 4000 (each group has 1 card) • Single door mode / 2 readers (one reader on each side of the door) • 2 door mode / 2 readers (one reader on each door) • 60 sec lockout after 15 invalid cards • Enroll sequential block of cards - max. block of 100 cards v.b2 107 mm 90 mm www.xprgroup.com 1 2. MOUNTING Rear view On wall 74,35mm m ,35m 74 On DIN Rail 3. TYPICAL TWO DOOR APPLICATION www.xprgroup.com 2 4. TERMINAL BLOCK DESCRIPTION Reader 1 Led Green Led Red GND power supply 12 VDC Data0 wiegand Data1 Reader 2 Led Green Led Red GND power supply 12 VDC Data0 wiegand Data1 12 VDC GND 12 VDC GND led’s NC COM NO NC COM NO led’s (NC) Door Sensors Exit Buttons (NO) (NC) (NO) Power Supply Door Sensor 1 GND Push Button 1 Door Sensor 2 GND Push Button 2 Door 1 Relay Door 2 Relay Alarm Outputs NC COM NO NC COM NO Door Left Open Alarm Forced Door Alarm Output 1 (door left open alarm) - ON if any door is left open by the time set in: ”Set door left open Alarm” - OFF when door is closed NOTE: If Door Sensors are not being used, the terminal blocks Door Sensor1 and Door Sensor 2 should be shorted with GND. By factory default, the controller will be delivered with shorted Door sensors. Output 2 (forced door alarm) - ON if any door is open by force - OFF when the door is closed NOTE: Do not connect different Wiegand type of readers. Both readers should be either Wiegand 26bit or Wiegand 34bit. 5. DIP SWITCH SETTINGS ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON Double Wiegand on Reader 1 Double Wiegand on Reader 2 APB follow sensor ON Anti Pass Back option ON Enroll Master Card ON Factory Reset ON 2 DOOR Mode Not used OFF Single Wiegand on Reader 1 Single Wiegand on Reader 2 APB follow sensor OFF Anti Pass Back option OFF Enroll Master Card OFF Factory Reset OFF 1 DOOR Mode Not used NOTE: Double wiegand is used for double security(Card + PIN Code). When LCSP-EM/MF is connected and LCSPEM/MF is set in double security mode, put the dipswitch 1 or 2 to position ON. NOTE: If Door sensors are not used, dipswitch No.3 should stay OFF. NOTE: In 1 Door Mode, both readers are assigned to Door1. User Card can be programmed to trigger both relays, which gives the option the second door relay to be used as alarm. www.xprgroup.com 3 6. WIRING 6.1 WIRING KEPADS LCSP, VKP, INOX, MTPAD-M 7. FACTORY RESET 1. Turn OFF the power Supply 2. Put DIP Switch 6 in position ON 3. Turn ON the power supply - Green LED - ON, Red LED - blinking 4. Put DIP Switch 6 in position OFF - Green LED - OFF, Red LED - blinking and goes OFF (wait for the Red LED to go OFF) www.xprgroup.com 4 8. PROGRAMMING IMPORTANT: Connect Proximity Reader(Wiegand26 or Wiegand34) to READER 1 Input, including its free tension LED’s.The Reader’s Free tension LED’s are used for visual indication during the programming process. Insert Master cards 1. Turn OFF the power supply 2. Push the dip switch no.5 in position ON 3. Turn ON the power supply Red LED - ON 4. On Reader1, present the master cards in this order: Master1&2, Delete, Reset APB, Master1, Master2 Note: For the first inserted card, the green led will blink once, for the second, the green led will blink twice...etc System can work without all master cards inserted (ex. Only Master, Delete and APB can be active). Minimum master cards are two (Master1&2 and Delete) 5. Put the dip switch in position OFF (SC24000 will return to operational mode) Mark the master cards with the stickers provided in the kit MASTER1&2 Card DELETE Card 217 40278 204 27141 Master1 Card Reset APB Card 205 49142 224 33143 Master2 Card 101 00147 NOTE: Changing Master and Delete Card is done with the same procedure. Old Master/Delete Cards are deleted automatically. Enroll a User 1. Present Master Card 2. Present Shadow Card 3. Present User Card - Green LED (or multiple User cards) 4. Present Master Card - Green LED - Green LED - ON, Red LED - ON Green LED - ON, Red LED - OFF blinks twice on each user card - OFF, Red LED - OFF Note: If the user is enrolled using MASTER1 card, the same user will have access only on DOOR1. If the user is enrolled using MASTER2 card, the same user will have access only on DOOR2. If the user is enrolled using Master1&2 card, the same user will have access on DOOR1 and DOOR2. NOTE: Shadow card can be issued for 1 user or for group of users. In both cases, write the name of the user on the shadow card and keep all of the shadow cards on safe place. NOTE: If more than one user is associated to same shadow card, deleting with that shadow card will result with deletion of all the Users associated to that shadow card. NOTE: If a shadow card needs to be changed, just enroll the same User with different Shadow card. Shadow Card 1 130 22346 Shadow Card 2 130 22345 Shadow Card 3 130 22344 User Card 1 User Card 1 130 22349 130 22349 User Card 2 130 22348 OR Group Shadow Card 233 26735 User Card 2 130 22348 User Card 3 User Card 3 130 22347 130 22347 www.xprgroup.com 204 27142 5 Enroll Sequential Block of Cards Note: There is no sequence of numbering Mifare cards. Enroll a Block of 100 sequential cards assigned to Door1: 1. Present Master1 Card 2. Present Shadow Card 3. Present the beginning card of the block 3 times 4. Present the ending card of the block 3 times 5. Present Master1 Card - Green LED- ON, Red LED - ON Green LED - ON, Red LED - OFF Green LED - blinks twice Green LED - blinks twice Green LED - OFF, Red LED - OFF Note: Before enrolling block of cards, make sure that the numbers are in sequence and that sequence is smaller than 100. Delete a User with its shadow card 1. Present Delete Card 2. Present Shadow Card - Green LED - ON, Red LED - ON Green LED-blinks twice, Red LED - ON 3. Present Delete Card - Green LED - OFF, Red LED - OFF (or multiple shadow cards) Note: By deleting a shadow card, all the Users associated to that shadow card will be deleted. Delete a User with user card 1. Present Delete Card 2. Present User Card - Green LED - ON, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Delete Card - Green LED - OFF, Red LED - OFF (or multiple user cards) Delete ALL Users 1. Present Delete Card 2. Present Master 1&2 Card 3 times 3. Present Delete Card - Green LED - ON, Red LED - ON Green LED - ON, Red LED - ON, Orange LED blinks once Green LED - OFF, Red LED - OFF Delete ALL Users assigned to DOOR1 1. Present Delete Card 2. Present Master 1 Card 3 times 3. Present Delete Card - Green LED - ON, Red LED - ON Green LED - ON, Red LED - ON, Orange LED blinks once Green LED - OFF, Red LED - OFF Delete ALL Users assigned to DOOR2 1. Present Delete Card 2. Present Master 2 Card 3 times 3. Present Delete Card - Green LED - ON, Red LED - ON Green LED - ON, Red LED - ON, Orange LED blinks once - Green Green LED - OFF, Red LED - OFF Reset All APB statuses 1. Present Reset APB card on any reader www.xprgroup.com 6 Set Door1 Open Time 1. Present Master 1 Card 3 times 2. Present Delete Card - Green LED - OFF, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Master 1 Card - Green LED - OFF, Red LED - OFF Present the card X times for X seconds (Door open Time) Set Door1 in Toggle (ON/OFF) Mode 1. Present Master 1 Card 3 times 2. Present Master 1 Card - Green LED - OFF, Red LED - ON Green LED - OFF, Red LED - OFF 1. Present Master 2 Card 3 times 2. Present Delete Card - Green LED - OFF, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Master 2 Card - Green LED - OFF, Red LED - OFF Set Door2 Open Time Present the card X times for X seconds (Door open Time) Set Door2 in Toggle (ON/OFF) Mode 1. Present Master 2 Card 3 times 2. Present Master 2 Card - Green LED - OFF, Red LED - ON Green LED - OFF, Red LED - OFF Set door left open Alarm To set 40 seconds for door left open time: 1. Present Master1&2 Card 3 times 2. Present Delete Card 4 times (4 x 10 sec. = 40 sec.) 3. Present Master1&2 Card To disable the alarm: Present Master1&2 Card 3 times Present Master1&2 Card Green LED - OFF, Red LED - ON Green LED - blinks twice, Red LED - ON - Green LED - OFF, Red LED - OFF - Red LED - ON Red LED - OFF 9. ANTI PASS BACK ON 1 2 3 4 5 6 7 8 DipSwitch No.4 - ON To enable the Anti Pass Back option simply put the dipswitch no.4 to position ON. If Door sensors are not being used at the installation, keep the dipswitch No.3 to position OFF. In this case, the APB Status shall be determined by a card punch (was the card presented or not). If Door sensors are used, then dipswitch. No3 should be in position ON. In this case, the APB status is determined by the door status (was the door open or not). www.xprgroup.com 7 10. EXAMPLES Task1: Make 1 Door installation with 1 Reader. Enroll 2 users to open the door. DIP switch settings: all are OFF 1. Present Master1 Card 2. Present Shadow Card 3. Present User Card 1 4. Present User Card 2 4. Present Master1 Card Task2: Make 1 Door installation with IN and OUT Reader. Enroll User1 with access to Door1 in Anti Pass Back Mode and additional User2 that will not have access to Door1, but will be able to turn the lights in the office ON/OFF. DIP switch settings: No.4-ON, all other are OFF Relay connection: Door relay1 - Door Lock; Door Relay 2 - Lights Main Switch 1. Present Master1 Card 2. Present Shadow Card 1 3. Present User Card 1 4. Present Master1 Card 1. Present Master2 Card 2. Present Shadow Card 2 3. Present User Card 2 4. Present Master2 Card User1 with Access to Door1 User2 to be able to activate Door Relay2 (Lights), but not Door Relay 1. 1. Present Master 2 Card 3 times 2. Present Master 2 Card Make Door relay 2 to work in ON/OFF Mode Task3: Make 2 Door installation. Enroll User 1 to open only DOOR1 and User 2 to open DOOR2 and User3 to open Door1 and Door2. DIP switch settings: 7 - ON; all others OFF Relay connection: Door relay1 - Door Lock; Door Relay 2 - Door Lock 1. Present Master1 Card 2. Present Shadow Card 1 3. Present User Card 1 4. Present Master1 Card 1. Present Master2 Card 2. Present Shadow Card 2 3. Present User Card 2 4. Present Master2 Card 1. Present Master1&2 Card 2. Present Shadow Card 3 3. Present User Card 3 4. Present Master1&2 Card User1 with Access to Door1 User2 with Access to Door2 User3 with Access to Door1 and Door2 11. PROGRAMMING WITH KEYPAD(LCSP, VKP, INOX,MTPAD-M) The programming with Keypad is same as programming with proximity reader. Please refer to programming explained on pages 4 to 7, just replace the word “Card” with “PIN Code” Keypad settings Set the keypad to be compatible with SC24000 Standalone Controller Press B+000000 to enter the menu Press 6 Press 1 Press A to exit the menu This will set the Keypad in “Wiegand26 bit Normal”, “4 Digits PIN Code” and “Card or PIN Code” mode(LCSP). For other settings (like changing PIN Code length), please refer to the keypad’s manual. www.xprgroup.com 8 12. PROGRAMMING IN DOUBLE SECURITY MODE(LCSP) Double Security Mode is possible only with double technology readers (proximity + keypad, LCSP) 1. If LCSP is connected to Reader1 Input put the dipswitch1 to position ON If LCSP is connected to Reader2 Input put the dipswitch2 to position ON 2. Set the keypad to double security mode Press B+000000 to enter the menu P ress 6 Press 4 Press 5 Press 3 Press A to exit the menu ON 1 2 3 4 5 6 7 8 This will set the Keypad in “Wiegand26 bit Double”, “4 Digits PIN Code” and “Card and PIN Code” mode. Insert Master cards 1. Turn OFF the power supply 2. Push the dip switch no.5 in position ON 3. Turn ON the power supply - Red LED - ON 4. On Reader1, present the master cards in this order: Master1&2 + ANY 4 digit Code Delete + ANY 4 digit Code Reset APB + ANY 4 digit Code Master1 + ANY 4 digit Code Master2 + ANY 4 digit Code Note: For the first inserted card, the green led will blink once, for the second, the green led will blink twice...etc System can work without all master cards inserted (ex. Only Master, Delete and APB can be active). Minimum master cards are two (Master1&2 and Delete) 5. Put the dip switch in position OFF (SC24000 will return to operational mode) Mark the master cards with the stickers provided in the kit MASTER1&2 Card 204 27141 DELETE Card 217 40278 Reset APB Card 205 49142 Master1 Card 224 33143 Master2 Card 101 00147 NOTE: Changing Master and Delete Card is done with the same procedure. Old Master/Delete Cards are deleted automatically. www.xprgroup.com 9 Enroll a User 1. Present Master Card 2. Present Shadow Card 3. Present User Card + + + ANY 4 digit Code ANY 4 digit Code ANY 4 digit Code - Green LED - ON, Red LED - ON Green LED - ON, Red LED - OFF Green LED - blinks twice on each user card 4. Present Master Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF (or multiple User cards + ANY 4 digit Code) Note: If the user is enrolled using MASTER1 card, the same user will have access only on DOOR1. If the user is enrolled using MASTER2 card, the same user will have access only on DOOR2. If the user is enrolled using MASTER1&2 card, the same user will have access on DOOR1 and DOOR2. IMPORTANT: With the procedure above, ONLY the Card is stored. To store the PIN Code, present the newly enrolled Card (the Orange LED will start blinking) and type the desired PIN code. In other words, after exiting the programming, the first time the card is punched, the first PIN Code typed becomes the Pin Code assigned to that card only. This feature can prevent the installer to know the PIN Code of the user. The user can choose his own PIN Code. NOTE: Shadow card can be issued for 1 user or for group of users. In both cases, write the name of the user on the shadow card and keep all of the shadow cards on safe place. NOTE: If more than one user is associated to same shadow card, deleting with that shadow card will result with deletion of all the Users associated to that shadow card. NOTE: If a shadow card needs to be changed, just enroll the same User with different Shadow card. Shadow Card 1 User Card 1 User Card 1 130 22349 130 22349 130 22346 Shadow Card 2 User Card 2 130 22345 Shadow Card 3 130 22348 Group Shadow Card 233 26735 OR User Card 2 130 22348 User Card 3 User Card 3 130 22347 130 22347 130 22344 204 27142 Delete a User with its shadow card 1. Present Delete Card + ANY 4 digit Code 2. Present Shadow Card + ANY 4 digit Code - Green LED - ON, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF (or multiple shadow cards) Note: By deleting a shadow card, all the Users associated to that shadow card will be deleted. Delete a User with user card 1. Present Delete Card + ANY 4 digit Code 2. Present User Card + ANY 4 digit Code - Green LED - ON, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF (or multiple user cards) www.xprgroup.com 10 Delete ALL Users 1. Present Delete Card + ANY 4 digit Code 2. Present Master 1&2 Card + ANY 4 digit Code 3 times 3. Present Delete Card + ANY 4 digit Code - Green LED - ON, Red LED - ON Green LED - ON, Red LED - ON, Orange LED blinks once Green LED - OFF, Red LED - OFF - Green LED - ON, Red LED - ON Green LED - ON, Red LED - ON, Orange LED blinks once Green LED - OFF, Red LED - OFF - Green LED - ON, Red LED - ON Green LED - ON, Red LED - ON, Orange LED blinks once Green LED - OFF, Red LED - OFF 1. Present Master 1 Card + ANY 4 digit Code 3 times 2. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Master 1 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF - Green LED - OFF, Red LED - ON Green LED - OFF, Red LED - OFF 1. Present Master 2 Card + ANY 4 digit Code 3 times 2. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Master 2 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF - Green LED - OFF, Red LED - ON Green LED - OFF, Red LED - OFF Delete ALL Users assigned to DOOR1 1. Present Delete Card + ANY 4 digit Code 2. Present Master 1 Card + ANY 4 digit Code 3 times 3. Present Delete Card + ANY 4 digit Code Delete ALL Users assigned to DOOR2 1. Present Delete Card + ANY 4 digit Code 2. Present Master 2 Card + ANY 4 digit Code 3 times 3. Present Delete Card + ANY 4 digit Code Set Door1 Open Time Present the card X times for X seconds (Door open Time) Set Door1 in Toggle (ON/OFF) Mode 1. Present Master 1 Card + ANY 4 digit Code 3 times 2. Present Master 1 Card + ANY 4 digit Code Set Door2 Open Time Present the card X times for X seconds (Door open Time) Set Door2 in Toggle (ON/OFF) Mode 1. Present Master 2 Card + ANY 4 digit Code 3 times 2. Present Master 2 Card + ANY 4 digit Code Reset All APB statuses 1. Present Reset APB card + ANY 4 digit Code on any reader www.xprgroup.com 11 Set door left open Alarm To set 40 seconds for door left open time: 1. Present Master1&2 Card + ANY 4 digit Code 3 times 2. Present Delete Card + ANY 4 digit Code 4 times - Green LED - OFF, Red LED - ON Green LED - blinks twice, Red LED - ON 3. Present Master1&2 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF To disable the alarm: Present Master1&2 Card + ANY 4 digit Code 3 times Present Master1&2 Card + ANY 4 digit Code - Red LED - ON Red LED - OFF (4 x 10 sec. = 40 sec.) This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS2 directive EN50581:2012 www.xprgroup.com 12 ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- 2 Door Control
- 4000 User Capacity
- Anti-Passback
- Wiegand Reader Support
- Adjustable Door Relay Time
- Double Security Mode (LCSP)
- Master Cards
- Shadow Cards
- Programming with Keypad
Frequently asked questions
The SC24000 can store up to 4000 users (cards).
The SC24000 supports both Wiegand 26bit and Wiegand 34bit readers. However, you should not connect different Wiegand types of readers. Both readers should be the same type.
The maximum block of cards that can be enrolled sequentially is 100 cards.
To factory reset the SC24000, turn OFF the power supply, put DIP Switch 6 in position ON, turn ON the power supply, then put DIP Switch 6 in position OFF. Wait for the Red LED to go OFF.
To set the door open time, present the appropriate Master card 3 times, then present the Delete card, then present the Master card again. Present the card the desired number of times for the corresponding number of seconds.