Advertisement
Advertisement
THE SOLIS CEILING FAN INSTALLATION INSTRUCTIONS Please read and save these instructions These instructions are to be used in the installation of the following OXYGEN fans... The Solis © 2018 oxygen Lighting. All Rights Reserved. 201 Railhead Rd • Fort Worth, TX 76106 • (877) 607-0202 • FAX (877) 607-0203 IO005-10/18 OXYGEN'S UNIQUE LIMITED LIFETIME WARRANTY This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. WHAT IS COVEREDExcept as specified below, the manufacturer of this product warrants it to be free of all defects in workmanship and material. WHAT IS NOT COVERED BY THIS WARRANTY1. All costs of removal or reinstallation of the fan. 2. Damage resulting from failure to follow instructions contained herein. 3. Damage occurring during shipment of the product (claims must be presented to the carrier). 4. Damage resulting from accident, misuse, abuse, or neglect. 5. Damage resulting from the application of any exterior coating, or by the addition of any unapproved accessories. 6. Damage resulting from repair or attempted repair by anyone other than the manufacturer. technical skill, competence, or experience of the user. superior product if the defective unit is returned prepaid to us. 8. Light bulbs, glass or acrylic components or accessories. TO GET WARRANTY SERVICE To obtain warranty service, the product must be returned prepaid to Oxygen. (This warranty is not enforceable outside the United States.) Details regarding return shipment are explained elsewhere in this manual. Whenever warranty service is required, you must present a copy of the original dated sales receipt as proof of coverage. 9. Minor occurrences of wobble are accepted as normal and should not necessarily be considered a defect. WHO MAY ENFORCE WARRANTYThis warranty may be enforced only by the original purchaser. The end user must possess a dated proof of purchase from an authorized Oxygen dealer to establish a warranty claim. LENGTH OF THE WARRANTY 1. For the fan motor - for the lifetime of the original purchaser. 2. For everything else, except blades and finish - one year from the date of purchase. 3. For fan blades and finish - 90 days from the date of purchase. WHAT WE WILL PAY FOR We agree to correct defects outlined in the warranty without charge, or at our option replace the fan with an equivalent or There is no other express warranty. Oxygen hereby disclaims any and all implied warranties, including but not limited to those of merchantability of fitness for a particular purpose to the extent permitted by law. Oxygen shall not be liable for incidental, consequential, or special damages arising out of or in connection with the product use or performance except as may otherwise be accorded by law. The duration of any implied warranty which cannot be disclaimed is limited to the periods specified above in the express warranty. 7. Damage resulting from causes other than product defects, including lack of WARRANTY SERVICE 1. Most problems can be handled by our customer service agents over the telephone. Customers seeking warranty repair or replacement for any fan or component are encouraged to call us for assistance. All returns must be issued a Return Goods Authorization number (RGA) prior to returning the defective unit or part. Call (877) 607-0202 Monday thru Friday 8:00 a.m. - 5:00 p.m. CST to obtain a RGA number. 2. Arriving shipments will be refused if they do not bear a valid RGA number on the outside packaging. 3. A dated proof of purchase must accompany any fan or component clearly indicating the name of the original purchaser. 4. To avoid damage in transit, the product should be returned in its original box and packaging. Oxygen will not bear responsibility for any shipping damage. 5. Any return of a fan or component must be shipped freight and insurance prepaid. FOR YOUR RECORDS Purchased From City State Fan Model No. Date Purchased Complete and mail the enclosed warranty card within 10 days to ensure your warranty is registered. If you have any questions regarding the warranty, or the procedures for obtaining service, please call us at (877) 607-0202 - Monday thru Friday 8:00 a.m. - 5:00 p.m. CST. 1. SAFETY RULES 1. To avoid possible electric shock, turn off the electricity at the main fuse box or circuit panel before you begin the fan installation or before servicing the fan or installing accessories. 2. Read all instructions and safety information carefully before installing your fan and save these instructions. 3. Make sure all electrical connections comply with local codes or ordinances as well as the National Electrical Code. If you are unfamiliar with electric wiring, please use a qualified and licensed electrician. 4. Make sure you have a location selected for your fan which allows clear space for the blades to rotate, and at lease seven (7) feet of clearance between the floor and the fan blade tips. Model #3-107-xx: 18.96 lbs 5. The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 50 pounds. To reduce the risk of fire, electric shock, or personal injury, use only an outlet box clearly labeled "Acceptable for Fan Support of 15.9 kg (35 lbs) or Less." 6. To reduce the risk of personal injury use only approved hanging brackets and screws supplied with the outlet box for mounting to the outlet box. 7. After installation is complete, check that all connections are absolutely secure. 10. Do not attempt to control the operation of the fan (or an optional light kit) from any wall control that is not approved by Oxygen for use with its fans. Do not use solid state wall controls. The use of any unapproved control voids the fan's warranty. TOOLS REQUIRED FOR INSTALLAITON Phillips Screwdriver Wire Cutters Electrical Tape Step Ladder 8. Do not insert anything into the fan blades while they are rotating. 9. To operate the reverse function on the fan, press the reverse button on the wall transmitter while the fan is running. 2. UNPACKING YOUR FAN Unpack your fan and check the contents. Do not discard the carton. If warranty replacement or repair is ever necessary the fan should be returned in original packaging. Remove all parts and hardware. Do not lay motor housing on its side - because the decorative casing may shift. Check all visible screws, bolts and nuts for tightness. Examine all parts. The following parts should be included: 1. Set of PC blades (a) 2. Blade support plates (b) 3. Hanging bracket (c) 4. Canopy (d) 5. Canopy cover (e) 6. Downrod rubber cover (f) 7. Downrod assembly (6"+4") (g) 8. Yoke cover (h) 9. Fan motor assembly (i) 10. Decorative cover (j) 11. Wall switch. 2 mounting screws and 3 wire nuts, Wall plate w/2 mounting screws and 2 machine screws (k) 12. Parts bags (l) containing: Blade attachment hardware (Screws/washers, washers may be attached to screws) Mounting hardware (wire nuts, wood screws, machine screws, lock washers, spring washers, metal washers.) 13. Blade balancing kit (m) a. NOTE: Some Oxygen fan models will have slightly different parts than what is shown here depending upon the design you have chosen. Basic installation procedures are similar for all models. j. d. e. f. g. h. b. k. l. m. i. c. IF YOU FIND THAT PARTS ARE MISSING. CONTACT YOUR DEALER FOR REPLACEMENT, OR CALL OXYGEN DIRECTLY AND WE WILL MAIL REPLACEMENTS TO YOU IMMEDIATELY. 3. MOUNTING OPTIONS 1. Disconnect the power by removing fuses or turning off circuit breakers. 2. If there is an existing outlet box, ensure it is clearly marked "Acceptable for Fan Support of 15.9 kg (35 lbs) or Less". If it is not so marked, it must be replaced with an approved one. 3. Secure the outlet box (or make sure the existing box is secured) directly to the building structure. Use appropriate fasteners and building materials. 4. Figures 1,2 and 3 are examples of different ways to mount the outlet box in different situations. A longer downrod may be required in sloped ceiling situations to maintain proper blade clearance. 5. To hang the fan in locations where no ceiling joist is available, a hanger support bar may be required (Figure 3). Hanger support bars are available at most area home centers. WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, FIRE, OR PERSONAL INJURY, MOUNT THE FAN ONLY TO AN OUTLET MARKED ACCEPTABLE FOR FAN SUPPORT AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX. Fig. 1 Fig. 2 Ceiling Joists Ceiling Joists Outlet Boxes Outlet Boxes Fig. 3 Ceiling Joists Fig. 4 Ceiling Joist Hanger Support Bar Ceiling Joist Angled ceiling maximum 25º angle Recessed outlet Boxes (with 4" downrod) Outlet Boxes CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, INSTALL THE PRIMARY MOUNTING MEANS AND USE ONLY THE HARDWARE PROVIDED WITH THE FAN. 4. HANGING YOUR FAN WARNING -Turn off the power! DO NOT fasten the blades to the fan until it is assembled and hanging from the ceiling. To do so now will likely bend the blade arms and almost certainly cause wobble. Fig. 5 Fig. 7 Downrod assembly 1. If not already affixed to the hanger bracket, place the rectangular rubber isolators between the hanger bracket and outlet box. Secure the hanger bracket to the outlet box using the 2 long steel screws supplied with the outlex box. 2. Remove the set pin and safety lock clip from the yoke on top of the motor assembly. Slide the downrod through the canopy and canopy cover. Slide the yoke cover onto the downrod (Fig. 5). Feed the wires and safety cable from the fan motor through the downrod assembly. 3. (Fig. 6) Attach the downrod assembly by feeding the wires and safety cable through the yoke cover, canopy cover, canopy and downrod assembly. Insert the downrod into the yoke. Slide the set pin through the yoke and downrod and secure with safety lock clip. Tighten the screws on yoke. Lower the yoke cover to conceal the yoke. Hanger bracket Ceiling canopy Canopy cover Yoke cover Fig. 6 Downrod rubber cover Downrod Canopy 4. Place downrod rubber cover onto the hanger ball. (Fig. 6) Canopy cover 5. Lift the fan motor without the blades and place into the hanger bracket, rotating the ball until the groove engages the tab on the hanger bracket. This locks the ball mount and fan motor, preventing fan rotation during operation. (Fig. 7) Yoke cover Yoke Set pin 6. Secure the safety cable to the building structure using a wood screw (not included). (Fig. 7) Safety cable Set screw Safety lock clip Downrod 5. ELECTRICAL CONNECTIONS REMEMBER -Turn off the power! 3. Inside the ceiling junction box be sure to spread the wires apart so that the black connection is on one side of the outlet box and the white/white and green/copper connections are on the other side. 5. Inside the ceiling junction box be sure to spread the wires apart so that the black connection is on one side of the outlet box and the white/white and green/copper connections are on the other side. Hook up in "series only" do not connect the hot and neutral wires of electric circuit to the wall control - damage to the wall control and possible fire could occur. Fig. 8 GROUND 2. (Fig. 9) Connect the BLACK building supply wire to the BLACK fan wire. Connect the WHITE building neutral wire to the WHITE fan neutral wire. Connect the COPPER building ground wire to the GREEN fan ground wire. Use ONLY wall controls approved by OXYGEN. Use of unapproved wall controls will cause unacceptable humming noise, and avoids the fan warranty. WH 1. Spread the wires apart so that the black wire from the fan is on one side of the mounting bracket and the white wire and green ground wire are on the other side. Carefully tuck the connected wires inside the junction box. Secure the wall control with the two screws provided. Attach the face plate over the wall control with the two screws provided. BLK Use the wire nuts supplied with your fan when making connections. Secure the connectors with electrical tape and make sure there are no loose connections or wire strands. BLK House supply wire Outlet box Connect one BLACK wire from the wall to one BLACK wire (labeled "TO FAN") from the wall control. Connect the other BLACK wire (labeled "TO POWER SUPPLY") from the wall control to the remaining BLACK wire from the wall (A/C supply source). If your junction box has a ground wire (green or bare copper), connect the wall control's ground wire to it. Otherwise, connect the wall control ground wire directly to one of the screws from the outlet box. GRN Remove the existing wall plate and switch from the wall junction box. WH BLK 4. Connect the wiring from the wall switch receptacle to wall control unit. Ceiling Fan canopy Wall control 6. COMPLETING THE INSTALLATION 1. Make sure the wiring is safely inside the Fig. 9 outlet box as instructed in Step 5 Electrical Connections. To install the canopy, slide the canopy up to hanger bracket and place the key hole on the Hanger canopy over the screw on the hanger bracket bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 9) Align the circular hole on canopy with the remaining hole on the hanger bracket, secure by tightening the two set screws, lift canopy cover and attach by turning Screws clockwise. Note: Adjust the canopy screws as necessary until the canopy and canopy cover are snug. (Fig. 9) Fig. 11 Outlet box Screws Canopy Canopy cover 2. Blade Assembly & Installation (Fig. Fig. 10 10) Using the supplied blade screws and blade support plates, attach the blades to the motor assembly by sliding blades through blade slots. In some cases the metal washer is permanently fixed to the screw head. Ensure all screws are used for each blade. DO NOT bend the blade arms when installing the blades. Decorative cover 3. Attaching the Decorative Cover (Fig. 11) Attach the decorative cover to the mounting plate by turning clockwise until snug. Blade support plate A certain amount of wobble may be considered normal, especially if the fan is on a downrod long than 12". Screws Blades 7. INSTALLING THE WALL CONTROL REMEMBER -Turn off the power! NOTE - Control must be installed within 30 feet of fan. 1. Remove the existing wall plate and switch from the wall junction box. 2. If your outlet box has a ground wire (green or bare copper) connect the wall control's ground wire to it; otherwise connect the wall control's ground wire directly to one of the screws from the outlet box. 3. (Fig. 12) Carefully tuck the wire connections inside the junction box. Secure the wall control with the two screws provided. Attach the wall plate over the wall control and secure with the two screws provided. Fig. 12 8. FAN OPERATION AND CARE Restore power to ceiling fan and test for proper operation. A. The fan 4-speed control knob is used to control the fan blade speed as follows: 0 = Turns the fan off 1 = High Speed 2 = Medium Speed 3 = Medium Low Speed 4 = Low Speed 1. A ceiling fan is an environmentally smart choice to cool as well as to help warm your home or office. Adjust your HVAC thermostat during fan use to save additional energy and money on your air conditioning and heating utility bills. You should see a significant reduction in both your heating and cooling costs by regular use of your fan. Do not hesitate to use your fan during summer and winter months. In summer, (Fig. 14) using the reverse switch, adjust the fan's direction so cool air is blown down, producing a cooling breeze. In winter, (Fig. 15) reverse the fan so that an upward airflow will push warm air off the ceiling and circulate it downwards into the living area. In winter months, use the fan at a lower speed than summer. 2. Periodically check tightness of all screws securing the blades to the blade arm attachment points. A clicking or a rattling noise is a sure indication of loosening screws. Since screws will invariably work loose over time, at least once a year, tighten all the screws attaching blades to blade arms. Do not bend blade arms when cleaning or servicing the fan. Fig. 13 Fig. 14 3. Clean you fan periodically using only a cloth dampened with a mild detergent solution for all hardware - never use solvents. The finish plating is lacquered to prevent tarnishing. Use a lint-free cloth with clean water to clean blades. 4. You will never need to oil or lubricate your fan. Its permanently sealed bearings will provide trouble free, silent operation for many years. 5. If repairs or servicing are ever required, to avoid possible electric shock, turn off the electricity at the main fuse or circuit panel before you begin. Fig. 15 WINTER 9. TROUBLESHOOTING FAN WILL NOT START 1. Check that the electricity has been turned on at the circuit breaker which had probably been turned off during installation. 2. Turn off the electricity. Check all connections in the wiring of the fan at the ceiling and make sure it follows the wiring instructions outlined in this manual. NOISE Note: Always allow a day or two "run-in" time for any new fan at medium or high speed. When attempting to diagnose noise, listen carefully from several sides to try and isolate the location of the noise (blade, upper end, motor, light kit, etc.) 1. Tighten all screws attaching blades to blade arms. Remember to tighten these screws at least once a year because they may loosen slowly over time and cause a clicking noise. 2. Turn off the power. Loosen the canopy and check that the wiring and/or wire nut connectors are not resting against the canopy, possibly vibrating while the fan is on. 3. Use of a standard light rheostat or an unapproved fan wall control to control the fan speed will always cause an annoying "hum". Many fan motors do not work quietly with solid state variable speed controls. 4. Check that the rubber gasket on the mounting bracket has been installed if called for in the installation instructions. 5. Check that the canopy in not touching the ceiling. 6. Check that all screws on the motor housing and the bottom housing are tight. FAN TURNS, BUT DOES NOT MOVE MUCH AIR 1. The fan may be running in reverse. The reverse switch located on the top of motor housing. (see Fig. 16) 2. The distance from the ceiling to the blades may be too small. For downrod fans, optimal placement would be 8-9 feet from the floor. 3. The room may contain items which obstruct the air flow. 4. The fan may be too small for the size of the room. Fig. 16 Reverse switch EXCESSIVE WOBBLE Note: A small amount of wobble is considered acceptable and should not be considered a defect. REPLACEMENT PARTS For replacement parts, contact your local dealer. ">
Advertisement