Allen-Bradley ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions
Allen-Bradley ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers are designed for use in industrial or control room environments, offering reliable performance and a range of connectivity options. These computers are equipped with a galvanically isolated DC-DC converter board for enhanced electrical noise immunity and feature protection against reverse polarity, temporary overvoltage, and inrush current. With a robust design, these computers are suitable for various applications requiring reliable data processing and communication in demanding industrial settings.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Original Instructions ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Bulletins 6300B - 6300P, Family EW1 Equipment with the UL/cUL mark complies with the requirements of UL 61010-1, UL 61010-2-201, CSA C22.2 No. 61010-1, and CSA C22.2 No. 610102-201. Copies of the certificate of compliance are available at rok.auto/certifications. Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Page Updated paragraph DC Power Supply Guidelines 5 Safety instructions ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to EN 613261. Without appropriate precautions, there can be potential difficulties with electromagnetic compatibility in other environments caused by conducted as well as radiated disturbance. In addition to this publication, see the following: • Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements. • UL 50, UL 50E, CSA C22.2, No. 94.1, and CSA C22.2, No. 94.2, as applicable, for explanations of the degrees of protection provided by enclosures. European Union Directive and UKCA Compliance This equipment meets the European Union Directive and UK requirements when installed within the European Union, UK, or EEA regions and have the CE or UKCA marking. A copy of the declaration of the conformity is available at rok.auto/certifications. ATTENTION: This computer is intended to operate in an industrial or control room environment, which uses some form of power isolation from the public low-voltage mains. All I/O circuits are rated for use with indoor cables only. Installation Requirements Follow these guidelines to make sure that your computer provides service with excellent reliability. • When choosing the installation site, consider the following: - The site must have sufficient power. - The site must be indoors and non-hazardous. - The site must not expose the computer to direct sunlight. • The computer can operate in the following environmental conditions: - Operating temperature: 0…50 °C (32…122 °F). - Storage temperature: -10…+60 °C (-4…+140 °F). Panel Installation min. clearance Wall mount Installation min. clearance Y -20° Y X 0° +20° X Z X Installation max. tilt* X Y Z Y * The vertical position can be tilted up to 20° forward or 20° backward from the upright position. However, this acceptable tilt angle range decreases the maximum operating air temperature to 45 °C (113 °F). Operation/storage relative humidity (RH) non condensing: 20…90%. Follow these requirements to mount the computer. • Choose a suitable mounting height. • To help prevent overheating and to provide access to the I/O ports for cable connections, mount the computer with the following minimum clearances from all four sides of the outer frame and back of the computer chassis: - X and Z direction ≥ 50 mm (1.97 in.) - Y direction ≥ 100 mm (3.94 in.) • For optimal performance, mount the computer in the horizontal orientation and vertical (upright) position, so the I/O ports face down. ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions Panel PC installation: prepare the Cutout Observe these guidelines to install the computer in a panel. WARNING: Failure to follow these guidelines can result in personal injury or damage to the panel components. Take precautions so any metal fragments during the panel cutout do not enter components that are installed already in the panel. AVERTISSEMENT: Le non-respect de ces directives peut entraîner des blessures ou des dommages aux composants du panneau. Prendre des précautions pour que les fragments métalliques pendant la découpe du panneau n’entrent pas dans les composants déjà installés dans le panneau. • • Plan the panel cutout area that is needed for your computer, consider minimum clearance provided, see Installation Requirements. To ensure installation with the proper IP protection grade, the following conditions must be satisfied: • The mounting panel material must be 2…6 mm (0.08…0.24 in.) thick with a max deformation limit on the plane of 0.5 mm (0.02 in.). • For a uniform gasket seal, the roughness of the panel surface must be ≤ 120 microns (Rz 120). • Verify that the area around the panel is clear of obstructions. Panel Cutout Areas Table 1 - Cutout Dimensions Panel Cutout Dimensions(1) [mm (in.)] Display Size, in. Cat. No. A B 10.4 6300P-EW110D 280.0 (11.02) 12.1 6300P-EW112E 315.0 (12.40) 15.0 6300P-EW115E 17.0 6300P-EW117G 19.0 6300P-EW119G (1) Panel Cutout Dimensions(1) [mm (in.)] Display Size, in. Cat. No. A B 225.0 (8.86) 12.1 W 6300P-EW112F 300.0 (11.81] 202.0 (7.95) 250.0 (9.84) 15.6 W 6300P-EW115L 387.5 (15.26] 237.5 (9.35) 370.0 (14.57) 295.0 (11.61) 18.5 W 6300P-EW118L 453.0 (17.83] 274.5 (10.81) 435.0 (17.13) 335.0 (13.19) 21.5 W 6300P-EW121L 520.0 (20.47] 312.0 (12.28) 470.0 (18.50) 368.0 (14.49) 24.0 W 6300P-EW124L 576.0 (22.68] 344.5 (13.56) A B Tolerance ±1 mm (0.04 in.). Panel installation: required tools Supplied tools 1 Tools required: • Panel cutout tools. • Hexagonal key 1.5 mm (0.06 in.) (supplied) and torque limiting screwdriver (not supplied) with a 1.5 mm (0.06 in.) hex key bit. • Mounting clips (supplied), for the needed quantity, see Figure 1. • Safety glasses for operator to wear during installation. 2 Sequence No. Description 1 Clip 2 Hexagonal key 1.5 mm (0.06 in.) Installation To install the computer in the panel cutout, perform the following steps. IMPORTANT • • • • Remove all electrical power from the panel before you make the cutout. Cut an opening in the panel area to the dimensions needed for your computer. After the cutout is completed, clean the panel area of all debris and metal fragments. Make sure that the sealing gasket is positioned properly on the computer. IMPORTANT 1. You need two people to install the computer; one person holds the computer in place while the second person installs the mounting clips. The gasket is a part of the display and forms a compression-type seal. Do not use sealing compounds. From the front of the panel insert the computer into the cutout (A) and rotate it (B) until it is completely against the panel (C). A 2. 2 B C Insert the mounting clips into the holes (D) on all four sides of the computer and repeat the procedure in step 3 through step 4 for all the clips. Rockwell Automation Publication 6300-IN002B-EN-P - July 2024 ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions D 3. 4. E G F Rotate it down (E) and pull it outward (F). According to the tighten sequence in Figure 1, tighten the mounting clips (G) with the supplied hexagonal key and verify the torque of 0.2 N•m (1.8 lb•in) with a limiting screwdriver [requires a 1.5 mm (0.06 in.) hex key bit]. Figure 1 - Mounting clips tighten and torque sequence by display size ATTENTION: Tighten the mounting clips to the specified torque to provide a proper seal and to help prevent product damage. Rockwell Automation assumes no responsibility for water or chemical damage to the computer or other equipment within the enclosure because of improper installation. 10.4 - 12.1 in. (8 clips) 5 8 1 10 1 3 7 12.1 - 18.5 - 21.5 - 24.0 in. (14 clips) 8 12 3 13 1 5 11 I/O Ports 14 6 4 8 9 7 11 6 5 15 I/O Ports 4 12 18 8 1 9 2 7 11 6 2 7 17 19 4 6 5 15 3 12 20 8 1 9 14 18 10 C D 2 7 23 17 9 21 11 4 20 I/O Ports 16 6 5 15 13 19 I/O Ports 16 2 21.5 - 24.0 in. (24 clips) 11 13 14 10 9 18.5 in. (20 clips) 3 13 16 2 17 9 4 3 6 7 5 8 I/O Ports 4 2 9 12 1 10 8 I/O Ports 6 15.6 in. (18 clips) 1 11 3 I/O Ports 4 7 10 10 1 12.1 - 15.6 in. (12 clips) 5 3 6 2 8 5 I/O Ports 4 12.1 in. (11 clips) 15.6 - 17.0 - 19.0 in. (10 clips) 14 3 12 22 24 18 10 2 7 Box PC Wall mount installation: Approximate dimensions Cat. No. System config. 6300B-EW1 A B C Dimensions [mm (In.)] A B C D E F 183.4 28.4 (1.12) 303.4 (7.22) 55.8 (2.20) 6.0 5.0 4.0 (11.94) 215.5 (0.24) (0.20) (0.16) (8.48) 76.8 (3.02) A E B F Wall mount installation: required tools • • Drill, 4.5 mm drill bit and M4 screw tap Qty 4 M4x20 Stainless steel screws, nuts, washers (customer supplied) • • Level • Safety glasses 2.5 mm Philips screwdriver • • Ruler Pencil For some wall materials you may need alternate tools and hardware. Installation Rockwell Automation Publication 6300-IN002B-EN-P - July 2024 3 ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions To execute the wall mount installation perform the following steps. IMPORTANT • • You need two people to install the box PC; one person holds the box PC in place while the second person installs the mounting screws. Determinate the placement of your Box PC. See Approximate dimensions. Level, measure, then mark the top of the selected holes (method 1) or keyhole slots (method 2) of the attached brackets. Method 1 (x4) • • Method 2 (x4) Drill holes in your mounting surface to accommodate for the four M4x20 stainless steel screws (not supplied). Insert the washers into the four M4x20 stainless steel screws. Method 2 (x4) Method 1 (x4) • • • • Hold the Box PC aligning the 4 holes in the bracket with the 4 holes in the mounting surface. Insert and partially tighten the four M4x20 stainless steel screws to the nuts as in the picture above. Insert and partially tighten the four M4x20 stainless steel screws into the nuts as in the picture above, leaving a gap equivalent to the bracket thickness. Lift and align the top set of mounting holes of the brackets on your Box PC with the top two screws. Align the bottom two screws. Slide your Box PC downward until all four M4x20 stainless steel screws are at the top of each bracket slot. • • • Fully tighten the four M4x20 stainless steel screws against the nuts with a torque that is appropriate for the screw and mounting surface. If you are attaching your Box PC to steel material, the recommended torque of the M4x20 stainless steel screws is 0.8...0.9 N•m (7.0...7.9 lb•in) Connectors/LEDs/Buttons Connect peripheral cables to the appropriate I/O ports on the computer. To comply with EN 61326-1, use the following for cable types. All I/O cables must be used only indoors, and USB cables must be less than 3 m (9.84 ft) long. 17 18 2 3 19 16 4 15 14 20 13 1 5 6 7 21 12 8 9 10 11 Table 2 - Connectors/LEDs/Buttons LED Color Description 1 Front Power On LED See 12 LED Power On explanation. 6300P-EW1*****A 6300P-EW1*****B 6300P-EW1*****C 2 Ground screw Ground the system All catalog numbers 4 Required cable Sys. Power State Item No. Function Rockwell Automation Publication 6300-IN002B-EN-P - July 2024 Cat. Nos. ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions Table 2 - Connectors/LEDs/Buttons Required cable Sys. Power State LED Color Item No. Description 3 UPS Tx/Rx - PS/Sys Off UPS Tx/Rx - PS/Sys Off connector 4 DC power Unshielded Power connector 5 1 x COM Shielded, Lenght: max. max 30m (98.42 ft) 1 x RS232/422/485 isolated serial port connector (DB9M). 6 1 x Display Port Shielded, Lenght: max. max 5m (16.40 ft) 1 x DisplayPort++ V1.2 connector. Unshielded, Lenght: <3m (9.84 ft) 4 x USB 3.1 Gen. 2 (Type A) connectors. Function 7 USB 8 LAN Shielded — 1 x Multi-Gig 2.5 Gigabit Ethernet (RJ45). 9 LAN Shielded — 2 x Gigabit Ethernet (RJ45). LED Thermal alarm / Low Battery / 10 Function 11 Red If the LED is blinking red, the CR2032 battery voltage is below 2.5V and the battery should be replaced with a new one. In this case, replace the RTC battery before going down to 2V because at such voltage there flashing could be loss of date and time. LED Mass Storage LED Power On Red If the LED is solid red, please shut off the system and check its cooling and power consumption. The measuring point is close to CPU and the Thermal limit is set to 100 °C (212 °F). Off No system error or warning. Green Access to a mass storage device (SSD or CFast) is happening through a SATA channel. flashing OFF 12 Cat. Nos. Off No access to a mass storage device (SSD or CFast) is happening and O.S. is running. — The system is not powered. Power supply only ON Green It is safe to turn off power supply. Operating system shutdown procedure is terminated. fading Full ON Green Full ON Green The system is running with UPS. flashing Power is drawing from the input power supply. System core is full-on. 13 Power Button Used to wake the processor from power button press. This Power Button will cause an internal CPU message to indicate a system request to go to a sleep or power down state. If the system is already in a sleep or power down state, this signal will cause a wake or power up event. If this button is pressed for more than 4 seconds this will cause an unconditional transition (power button override) to power down status. 14 Function Button Available for applications, push button state is readable by software. 15 Reset Button Reset button. Forces an internal reset, as if power was lost temporarily and then returned. IMPORTANT: Use this button only if there are no better options, like keyboard or mouse commands, or if the resumed DC power does not restart the computer. System reset can cause data loss and possible corruption to the operating system 16 Add-On area position B (Optional Add-on modules configurable alternatively when ordering) 1 x Gigabit Ethernet (RJ45) 1 x RVL (RJ45) 6300P-EW1*****B 6300B-EW1*B 6300P-EW1*****C 6300B-EW1*B 17 Expansion Slot (Card opening for optional riser cards) 1 x PCI half-length or 1 x PCIe x4 half-length, on riser card 6300P-EW1*****C 6300B-EW1*C 18 Add-On area position A (Optional Add-on modules configurable alternatively when ordering) 2 x RS232/422/485 isolated (DB9M) 2 x USB 2.0 (Type-A) 1 x Gigabit Ethernet (RJ45) + 1x USB 2.0 (Type-A) 6300P-EW1*****B 6300B-EW1*B 6300P-EW1*****C 6300B-EW1*C 19 CFast & Battery Slot cover CFast & Battery Slot cover. See publication 6300-UM003 on how to remove the cover. 20 Battery tray Slot Battery tray Slot. See publication 6300-UM003 on how to replace the RTC battery. 21 CFast Slot. See publication 6300-UM003 on how to replace the CFast. CFast Slot All catalog numbers DC Power Supply Guidelines All computers have the following features: • The internal power supply of the computer has a galvanically isolated DC-DC converter board for increased electrical noise immunity. • Reverse polarity circuitry, temporary overvoltage, and a 8 A soldered fuse provide input power protection. Inrush current lInrush, pk (<15 A) Follow these guidelines to select the DC power to supply the computer. • The system must only be connected to a 24V DC SELV ( ) [maximum admissible operating • • voltage range 18...32V DC ( )] . The nominal output power should be 25% larger than the drained power. The output voltage rise time has to be less than 100 ms. T<2 ms lInrush, pk: Inrush Peak Current T: time Rockwell Automation Publication 6300-IN002B-EN-P - July 2024 5 ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions • 6300P-EW1 has a max. power consumption of 85W: - Iin= 3.5A max. @24V (nominal voltage). - Iin= 4.7A max. @18V (min. voltage). - Iin= 2.6A max. @32V (max. voltage). 6300B-EW1 has a max. power consumption of 60W: - Iin= 2.4A max. @24V (nominal voltage). - Iin= 3.3A max. @18V (min. voltage). - Iin= 1.8A max. @32V (max. voltage). • Connect DC Power ATTENTION: The system must be powered with a 24V DC (18...32V) power supply which satisfies the requirements of safe extra low voltage (SELV) in accordance with IEC/EN/DIN EN/UL61010-1 and UL61010-2-201. The power supply has to fulfill the requirements NEC Class2 or LPS in accordance with IEC/EN/DIN EN/UL61010-1 and UL61010-2-201. To minimize ground loop currents and noise, we recommend that DC powered models use only one grounded connection. Install the Factory-supplied DC Power Connector Assembly Tools required: • Adjustable torque screwdriver with M2 and M3 flat-blade screw bits. • Wire stripper, cutter, and crimper tool. • Cutting pliers. Terminal block cabling procedure Table 3 - Terminal Block Connection Specifications Item No. Description • • 1 DC+ (24V DC nominal) 2 DC- (0V DC nominal) 3 Stripped wire length 4 Terminal block DC power connector assembly Value A wire (not included) with a cross-section of 1.5 mm² [16 AWG] with copper conductor, certified for operation at least 75 °C (167 °F). 1 6 2 Polarity symbol 6 Torque range to secure DC power wires 0.22...0.25 N•m (1.95...2.21 lb•in) 7 Torque value to reinstall DC terminal block to computer 0.3 N•m (2.65 lb•in) 8 Cable tie (qty: 1) — 9 Labels (qty: 2) — 10 Half cover with cable tie slot — 11 Half closing cover — 7 3 — 5 5 4 Terminal block cover kit — 11 10 9 8 Remove the DC terminal block (4) from the computer. Use wires (not included), (1) (2) with 1.5 mm2 (16 AWG) cross section with copper conductor certified for operation at least 75 °C (167°F). The colors of wires should follow regulations applicable where the system will be used. • Strip 7 mm (0.276 in.) from the end of each power wire (3), insert each stripped end into the DC terminal block and fix it with the corresponding screws (6) with 0.22...0.25 N•m (1.94...2.21 lb•in) torque. A • • • B C Terminal block cover assembly D E F Insert the cable tie (8) through the slots of the terminal block (10) connector clamp [step (A)]. Slide the connector half with the attached tie onto the end of the DC terminal block (4) [step (B)]. Tighten cable tie (8) and remove the excess part [step (C)] and install the white labels (9) supplied with the terminal block cover kit [steps (D) (E)]. The white label can be used for identification or other information. 6 G Rockwell Automation Publication 6300-IN002B-EN-P - July 2024 ASEM 6300B-EW1 and 6300P-EW1 Entry Level Industrial Computers Installation Instructions • Align and install half closing cover (11) [step (F)] to complete the assembly [step (G)]. When installed correctly, both tabs of the clamp lock into place. • Connect the DC terminal block (with cables and cover) to the computer chassis and fix it with the corresponding screws (7) with 0.3 N•m (2.66 lb•in) torque. Grounding and bonding Whenever two connected pieces of equipment are far apart, it is possible that their ground connections could be at a different potential level. To overcome possible grounding problems, the following bonding methods are recommended: • Method 1: Connect the data cable shields to the Equipotential bonding rail on both sides before connecting the cable to the interfaces. • Method 2: Use an Equipotential bonding cable 16 mm2 (5 AWG) to connect the grounds between pieces of equipment (for example ASEM 6300B/6300P computer and 6300M monitor). For further information, see Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Tools required: • Wire (not included) • Philips screwdriver • Crimp lug tool Installation • • • • • • • Turn off the main power switch or breaker and remove the supplied nut, eyelet terminal, and washers from the ground screw. For earth ground, fasten a 2.5 mm2 (14 AWG) external wire with copper conductor, certified for operation at least 75 °C (167 °F) to the eyelet terminal. Use a ground wire with an insulation color that is approved by local inspection authority. Strip 5 mm the covering from the end of the grounding wire. Insert the stripped end (2) of the grounding wire (1) into the open end of the Eyelet terminal (3) and crimp it securely to the wire. Install the ground wire to the ground screw. Tighten the screw to the system. • Wire stripper Ground wire assembly 1 Ground screw installation sequence 9 8 7 6 5 Safety glasses Sequence No. Dscription 1 Wire (not provided) 5 mm (0.20 in.) stripped 2 covering 3 Lug 3 2 • 4 Sequence No. Dscription 4 Ground screw 5 Lock washer 6 Washer Eyelet terminal with cable 7 crimped 8 Toothed washer 9 Chassis’ ground hole Start the Computer • • • Make sure that all necessary peripheral devices are connected to the corresponding I/O ports on the computer. Make sure any connected components with separate power supplies (such as an external display) are turned on first (all ASEM I/O are isolated, be sure third part I/ O are isolated before to be turned on). Apply power to the main power switch or breaker. Once power is applied, various light-emitting diode (LED) status indicators illuminate to display the state of your PC. See Table 2 for details of these LED status indicators. Install the factory-supplied metal retention plates to connect Ethernet cables The system is provided with metal retention plates, screws and zip ties provided in the box. Their purpose is to support Ethernet cables after you plug in the ports in Shock & Vibe environments. Tools required: • • • • Cutting pliers • Adjustable torque screwdriver with M2 and M3 flat-blade screw bits Position the metallic plate (1) in front of the LAN ports and secure it with the provided screw (2) with 0.22...0.25 N•m (1.95...2.21 lb•in) torque [step (A)]. Insert the LAN cable in the LAN port [step (B)]. Insert the zip tie around the LAN cable and the beveled edge of the plate, tighten the tie (3) and remove the excess part [step (C)]. Metal retention kit 1 2 3 Item No. A B C Rockwell Automation Publication 6300-IN002B-EN-P - July 2024 Description 1 Metallic plate 2 M3 screws (qty: 2) 3 Zip ties (qty: 3) 7 Battery removal This computer contains a sealed lithium battery that could need replacement during the life of the computer. For instructions to remove and replace the battery, refer to publication 6300P-EW1 Panel PC / 6300B-EW1 Box PC User Manual, 6300-UM003. At the end of its life, collect the battery contained in this computer separately from any unsorted municipal waste. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. You can view or download publications at rok.auto/literature. Resource Description 6300P-EW1 Panel PC / 6300B-EW1 Box PC User Manual, 6300-UM003 Provides details on how to install, configure, operate, and troubleshoot. ASEM 6300 Industrial PCs, Thin Clients, and Monitors Specifications 6300-TD001 Provides technical specifications. Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines to install a Rockwell Automation industrial system. Product Certifications Website, rok.auto/certifications Provides declarations of conformity, certificates, and other certification details. Rockwell Automation Support Use these resources to access support information. Technical Support Center Find help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates. Local Technical Support Phone Numbers Locate the telephone number for your country. rok.auto/support rok.auto/phonesupport Technical Documentation Center Quickly access and download technical specifications, installation instructions, and user manuals. rok.auto/techdocs Literature Library Find installation instructions, manuals, brochures, and technical data publications. rok.auto/literature Product Compatibility and Download Center (PCDC) Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes. rok.auto/pcdc Documentation Feedback Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. Waste Electrical and Electronic Equipment (WEEE) At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, ASEM, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 6300-IN002B-EN-P - July 2024 | Supersedes Publication 6300-IN002A-EN-P - April 2024 Copyright © 2024 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. *PN-706630* PN-706630 PN-706630 10007581217 (Version 01) Vendor Code: 80460182.01 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Galvanically isolated DC-DC converter
- Reverse polarity protection
- Temporary overvoltage protection
- Inrush current protection
- Multiple I/O ports
- Robust design
- Industrial environment suitability
Frequently asked questions
The operating temperature range is 0 to 50 °C (32 to 122 °F).
The computers require a 24V DC SELV power supply (18...32V DC). Refer to the Installation Instructions for detailed instructions on connecting the DC power supply.
Two grounding methods are recommended: Connecting data cable shields to the Equipotential bonding rail or using an Equipotential bonding cable to connect grounds between pieces of equipment.