Allen-Bradley ASEM 6300B Box PCs and 6300T Thin Clients are rugged, reliable, and designed for industrial environments. These devices offer a wide range of features for various applications. The ASEM 6300B series is suitable for use in hazardous locations and non-hazardous locations. The 6300T series includes thin clients that are designed for use in industrial environments. The ASEM 6300B and 6300T devices offer various I/O ports and options for expanding their capabilities, providing flexibility for different needs.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Original Instructions ASEM 6300B Box PCs and 6300T Thin Clients Catalog Numbers 6300B-xxA, 6300B-BMB, 6300B-xxF, 6300B-xxN, 6300T-BA, 6300T-BB The following catalog numbers are ASEM™ 6300B Edge Box PCs intended for use with FactoryTalk® Edge™ Manager: • 6300B-BMBDNE-3DBAE01FNNBNN-NN1S • 6300B-BMBDNE-3DBAE01NNNBNN-NN1S • 6300B-BMBDNE-7EDAE01FNNDNN-NN1S • 6300B-BMBDNE-7EDAE01NNNDNN-NN1S These catalog numbers have a unique Edge Virtualization Engine operating system (EVE-OS) orchestrated from FactoryTalk Edge Manager. If you have sent the product to be returned or repaired, the device software and data has been erased and the EVE-OS has been reinstalled. For more information on FactoryTalk Edge Manager, see publication 95055-UM007-EN-P and publication 95055-QS003-EN-P. Topic Page Summary of Changes 1 Compliance 1 Environment Requirements 2 Hazardous Locations 2 Installation Requirements 3 Mount the Product 4 Connect the DC Power Wiring 4 Technical Data 7 Additional Resources 10 Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Page Updated Hazardous Locations information 2 Compliance UL/cUL Mark Compliance Equipment with the UL/cUL mark complies with the requirements of UL 121201, UL 61010-1, UL 61010-2-201, CSA C22.2 No. 213, CSA C22.2 No 61010-1, and CSA C22.2 No. 61010-2-201. A copy of the certificate of compliance is available at rok.auto/certifications. European Union and UK Directive Compliance This equipment meets the European Union and UK Directive requirements when installed within the European Union, UK, or EEA regions and have the CE or UK marking. A copy of the declaration of the conformity is available at rok.auto/certifications. ATTENTION: This equipment is intended to operate in an industrial or control room environment, which uses some form of power isolation from the public low-voltage mains. Some computer configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union or UK. All I/O cables must be used only indoors. ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions Environment Requirements ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/EN 61326-1. Without appropriate precautions, there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbance. This equipment is considered open equipment, which means it must be mounted in an enclosure where the equipment can be operated from the front panel. The enclosure in which this equipment is installed must be accessed only with a key or tool, and only by trained and authorized personnel. In addition to this publication, see the following: • Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements. • UL 50, CSA C22.2 No. 94.1, and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures. Follow these environment requirements to make sure that your ASEM 6300B box PC or 6300T thin client provides service with excellent reliability. • Your installation site: - must have sufficient power, - must be indoors and non-hazardous, - must not expose your box PC or thin client to direct sunlight, and - must be placed in an industrial or control room environment, which uses some form of power isolation from the public, low voltage mains. • The surrounding air temperature must not exceed the maximum temperature for your box PC or thin client, especially when mounted in an enclosure. The surrounding air temperature ranges are: - 0…55 °C (32…131 °F) with the Intel Atom® x5 processor - 0…50 °C (32…122 °F) with the Intel Atom x7 processor and Intel® Core™ i3, Core i5, and Core i7 processors • Your 6300B box PC or 6300T thin client can be stored in a surrounding air temperature range of -10…+60 °C (+14…+140 °F). • Operating and storage: 20%…90% relative humidity (RH) noncondensing Hazardous Locations The location categories for hazardous locations are listed below. IMPORTANT Only the 6300B-xxN and 6300T-BB catalog numbers are rated for use in hazardous locations. All other product families in this document (6300B-xxA, 6300T-BA) are rated for use in ordinary locations only. IMPORTANT All systems that have "-C" as the final character in the catalog number are not ATEX compliant. Examples: • 6300B-xxxxxx-xxxxxxxxxxxxx-xxxx-C • 6300T-xxxxxx-xxxxxx-xxx-C Location Categories for Hazardous Locations Region United States Canada Rating Class I Zone 2, IIC, T4 Class I Division 2, Groups A, B, C, D T4 Class I Zone 2, IIC, T4 Europe (ATEX) United Kingdom (UK) 2 Temperature Range Class I Division 2, Groups A, B, C, D T4 II 3 G, Ex ec IIC T4 Gc == = II 3 G, Ex ec IIC T4 Gc Storage: -20 °C ≤ Ta ≤ +60 °C (-4 °F ≤ Ta ≤ +140 °F) Operating: 0…+50 °C (32…+122 °F) Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions North American Hazardous Location Approval The following information applies when operating this equipment in hazardous Informations sur l’utilisation de cet équipement en environnements dangereux. locations. Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. product is supplied with markings on the rating nameplate indicating the hazardous Chaque produit est livré avec des marquages sur sa plaque d'identification qui location temperature code. When combining products within a system, the most indiquent le code de température pour les environnements dangereux. Lorsque adverse temperature code (lowest "T" number) may be used to help determine the plusieurs produits sont combinés dans un système, le code de température le plus overall temperature code of the system. Combinations of equipment in your system défavorable (code de température le plus faible) peut être utilisé pour déterminer le are subject to investigation by the local Authority Having Jurisdiction at the time of code de température global du système. Les combinaisons d'équipements dans le installation. système sont sujettes à inspection par les autorités locales qualifiées au moment de l'installation. WARNING: AVERTISSEMENT: Explosion Hazard – Risque d’Explosion – • Do not disconnect equipment unless power has been removed • Couper le courant ou s'assurer que l'environnement est classé or the area is known to be nonhazardous. non dangereux avant de débrancher l'équipement. • Do not disconnect connections to this equipment unless power • Couper le courant ou s'assurer que l'environnement est classé has been removed or the area is known to be nonhazardous. non dangereux avant de débrancher les connecteurs. Fixer tous Secure any external connections that mate to this equipment les connecteurs externes reliés à cet équipement à l'aide de vis, by using screws, sliding latches, threaded connectors, or other loquets coulissants, connecteurs filetés ou autres moyens means provided with this product. fournis avec ce produit. • Substitution of components may impair suitability for Class I, • La substitution de composants peut rendre cet équipement Division 2. inadapté à une utilisation en environnement de Classe I, • If this product contains batteries, they must only be changed in Division 2. an area known to be nonhazardous. • S'assurer que l'environnement est classé non dangereux avant de changer les piles. Restricted Access Location UL/cUL Mark Compliance WARNING: ASEM 6300 devices for hazardous locations must be installed in a restricted access location. Verify that restricted access locations meet these conditions for the ASEM 6300 devices for hazardous locations: • Access is gained only by service personnel or by users who have been instructed on the reasons for restrictions to a location and about any precautions to be taken. • Access is by using a tool, a lock and key, or other means of security controlled by the authority responsible for the location. AVERTISSEMENT: Les dispositifs ASEM 6300 pour environnement dangereux doivent être installés dans une zone d’accès restreint. Vérifiez que les zones d’accès restreint répondent aux conditions suivantes d’installation pour dispositifs ASEM 6300 adaptés aux environnements dangereux: • L’accès est réservé au personnel de service ou aux utilisateurs qui sont informés des motifs de restrictions d’accès à cette zone et des précautions à prendre. • L’accès se fait à l’aide d’un outil, un verrou et une clé, ou tout autre moyen de sécurité contrôlé par l’autorité responsable de la zone. EXPLOSION HAZARD: Do not connect or disconnect any accessories to ASEM 6300 devices for hazardous locations unless power has been switched off and the area is known to be non-hazardous. Before power is switched on, verify that any adapter, cable, or power connection accessory is fully inserted in its port. For adapter and cable accessories, verify that latches are engaged, and any screws are fully engaged and tightened. Failure to do so could result in an electric arc that can cause an explosion in a hazardous location. RISQUE D’EXPLOSION: Ne pas connecter ou déconnecter tout accessoire destinés aux dispositifs ASEM 6300 pour environnement dangereux tant que l’alimentation n’a pas été coupée et que la zone n’est pas réputée non dangereuse. Avant la mise sous tension, vérifiez que tous les adaptateurs, câbles ou accessoires de connexion d’alimentation sont correctement insérés dans leur port. Pour les accessoires d’adaptateur et de câble, vérifiez que les verrouillages sont engagés et que les vis sont complètement insérées et serrées. Le non respect de cette précaution pourrait entraîner un arc électrique susceptible de provoquer une explosion dans un environnement dangereux. Installation Requirements Follow these requirements to make sure that your 6300B box PC or 6300T thin client provides service with excellent reliability. DC Power Supply Guidelines Follow these guidelines to select the DC power supply for your box PC or thin client. ATTENTION: For applications with an AC power source, the shipped AC-to-DC power adapter must be plugged into a grounded outlet to maintain an electrically safe installation. An AC power supply cannot be used in a hazardous location. • • • • • Your 6300B box PC or 6300T thin client must be powered with a voltage of 24V DC (18…32V DC). The DC supply should be able to provide momentary current of at least 10 A for up to 400 µs for 6300B box PC or 6300T thin client inrush current. The nominal output power must be 25% larger than the drained power. The output voltage rise time has to be less than 100 ms. Consider the working temperature and thermal derating of the power supply. Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 3 ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions Mounting Requirements Follow these requirements to mount your 6300B box PC or 6300T thin client. • For use in a hazardous location, the 6300B must be installed in an enclosed panel. • Choose a suitable, ergonomic mounting height. • Only mount your 6300B box PC or 6300T thin client in a vertical, 0° upright) position where the ground screw is at the bottom. • Mount your 6300B box PC or 6300T thin client so there is at least 20 mm (0.79 in.) of clearance on each side for the circulation necessary for cooling. Required Tools and Hardware To mount and connect your 6300B box PC or 6300T thin client, the following tools and hardware are required: • Safety glasses • Drill and 4 mm drill bit • #2 Phillips screwdriver • Adjustable torque screwdriver with bits • DIN Rail (for DIN Rail installation only • Wire stripper/crimper/cutter tool • Various I/O shielded cables • DC power supply Mount the Product Follow these steps to mount your 6300B box PC or 6300T thin client. Select models feature optional PCIe slots, removable drive slots, an internal USB port, and/or CFAST slot. Before mounting, install these peripherals. See Table 3 on page 6 for peripheral locations and the User Manual for your respective model (see Additional Resources on page 10) to properly install these peripherals. Use the Supplied Brackets To mount your 6300B box PC or 6300T thin client with supplied brackets: 1. Locate and drill holes for four M4x20 stainless steel screws against your mounting surface. See Approximate Dimensions on page 7. 2. Partially tighten the four M4x20 stainless steel screws (not supplied) into your mounting surface. Leave enough space to hang the brackets. 3. Align the keyhole slots on the top bracket with the top two screws. 4. Align the slots on the bottom bracket with the bottom two screws. 5. Slide your box PC or thin client downward until all four screws are at the top of each bracket slot. 6. Tighten the four screws flush against your mounting surface. Use a DIN Rail Bracket — 6300B-DRF, 6300B-DRN, and 6300T-BBD IMPORTANT 1. 2. A DIN Rail is not supplied with the book mount bracket. An installed DIN Rail is the responsibility of the customer. Plan your DIN Rail installation according to the approximate dimensions shown in Figure 5 on page 8. Install your box PC onto the installed DIN Rail according to the DIN Rail installation instructions, publication 6300V-IN002. Connect the DC Power Wiring Follow these steps to connect your 6300B box PC or 6300T thin client to a DC power source. ATTENTION: Your 6300B box PC or 6300T thin client must have its own supply disconnect. If your 6300B box PC or 6300T thin client features an universal power supply (UPS) connection, use a UPS (not supplied) to help protect against unexpected power failure or power surges. Install the Ground Wire 4 1. 2. Turn off the main power switch or breaker. Remove the supplied nut, eyelet terminal, and washers from the ground screw. 3. 4. 5. 6. For earth ground, fasten a 2.5 mm2 (14 AWG) or larger external wire to the eyelet terminal. Use a ground wire with an insulation color approved by local inspection authority. Install the ground wire to the ground screw in the sequence shown at the right. Tighten the nut to the ground screw. 1 2 Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 3 4 5 Sequence No. Description 1 Toothed washer 2 Eyelet terminal 3 Washer 4 Lock washer 5 Nut ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions Attach the Power Connector Assembly The factory-supplied connector assembly provides strain relief for the DC power wires by reducing their movement. Perform the following steps to attach the power connector assembly. For 6300B-BMA, 6300B-BMB, 6300B-DRA, and 6300T-BA IMPORTANT The DC terminal block that is shown is for illustrative purposes only. Your DC terminal block may differ in size, shape, and color. Figure 1 - DC Power Connector Assembly Steps E B A C F D Table 1 - DC Power Connection Assembly: 6300B-BMA, 6300T-BA, 6300B-BMB 6300B-BMB 6300B-xxA and 6300T-BA 5 5 1 3 4 2 3 4 1 3 4 2 3 4 5 1. 2. 3. 4. Description 1 DC+ (24V DC nominal) recommended power wire size 2 DC- (0V DC) recommended power wire size 6300B-BMA, 6300T-BA 6300B-BMB 1.5 mm2 (16 AWG) 2.5 mm2 (14 AWG) 3 Stripped wire length 7 mm (0.275 in) 7 mm (0.275 in) 4 Torque range to secure DC power wires 0.22...0.25 N•m (0.16...0.18 lb•ft) 0.5...0.6 N•m (0.37...0.4 lb•ft) 5 Torque value to reinstall DC terminal block to the chassis 0.3 N•m (0.22 lb•ft) 0.3 N•m (0.22 lb•ft) Remove the DC terminal block from the chassis of your box PC. Open the power connector assembly kit that ships with your box PC or thin client (A of Figure 1). Insert the cable tie through the slots of the appropriate connector half (B of Figure 1). Strip the end of each DC power wire to the length specified in Table 1. IMPORTANT 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 5 Note No. DC power wires must be of stranded copper and certified for at least 85 °C (185 °F) operation. Insert each stripped end into the DC terminal block as shown in the figure at right. Tighten the screws on top of the terminal block to secure the DC power wires to the torque value in Table 1. Slide the connector half with the attached tie onto the end of the DC terminal block (C of Figure 1). Tighten the cable tie so it is snug against the terminal wires. Use cutting pliers to cut the excess part of the cable tie (D of Figure 1). Optional: Write an identification or other information on the white label. Install the white label supplied with the kit (E of Figure 1). Align and install the other connector clamp half to complete the assembly (F of Figure 1). When it is installed correctly, both tabs of the clamp half lock into place. Reconnect the DC terminal block with the connector assembly to the chassis of your box PC or thin client. Torque the DC terminal block flange screws to the values in Table 1. For 6300B-xxF, 6300B-xxN, and 6300T-BB Table 2 - DC Power Connection Assembly 2 1 1. 2. 3 2 1 4 3 Note No. Abbreviation Function 1 + + Input voltage (fused) 2 — - Input voltage 3 SYS OFF System OFF input 4 PS Power status output (0.5 A limited) Remove the DC terminal block from the chassis of your box PC. Strip 10 mm (0.4 in.) from the end of four different-colored wires. IMPORTANT 3. 4. 5. 6. 4 Use stranded copper wire sized 1.5 mm2 (16 AWG) and certified for at least 85 °C (185 °F) operation. Press the spring connection tabs on the DC terminal block, and insert each stripped end of wire according to Table 2. Release the spring connection tabs after the stripped end of each wire has been fully inserted in the appropriate terminal connection. Reconnect the DC terminal block to the chassis of your box PC or thin client. Torque the DC terminal block flange screws to 0.3 N•m (0.22 lb•ft). Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 5 ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions Attach I/O Cables and DC Power IMPORTANT To comply with EN 61326-1, the following cable types must be shielded: Digital I/O, DisplayPort, DVI-D, LAN, RS-232 DB9M, USB 2.0, and USB 3.0. All I/O cables must be used only indoors, and USB cables must be less than 3 m (9.84 ft) in length. Whenever two connected pieces of equipment are far apart, it is possible that their ground connections could be at another potential level. To overcome these possible grounding problems, the following bonding methods are recommended: Method 1: Connect the data cable shields to the equipotential bonding rail on both sides before connecting the cable to the interfaces. Method 2: Use an equipotential bonding cable (16 mm2 or #6 AWG) to connect the grounds between the 6300B Box PC/6300T Thin Client and a connected monitor. IMPORTANT • All DC powered models require a safety extra low voltage (SELV) power supply. The internal power supply is protected against reverse polarity. • To minimize ground loop currents and noise, we recommend that DC powered models use only one grounded connection. See Install the Ground Wire on page 4 for the ground connection on these models. • Follow all guidelines as stated in DC Power Supply Guidelines on page 3. The I/O port and slot locations of your shipped product may vary from the drawings that are shown in Table 3. Table 3 - I/O Port and Peripheral Slot Locations 6300B-BMB Front View (Vertical Upright) 6300B-BxxF Front View (Vertical Upright) 6300B-BxxA, 6300T-BA Front View (Vertical Upright) 1 1 3 3 8 7 6 5 5 3 9 6300B-xxN and 6300T-BB Front View (Vertical Upright) 7 11 1 7 UPS Connection future option 2 3 3 5 5 10 4 3 2 Cable Type Required Attribute Note No. Cable Type 1 24V DC Power Input Unshielded 7 RS232-DB9M 2 Ethernet LAN 8 DVI-D 3 USB 3.0 4 USB 2.0 5 6 12 2 Note No. 1. 2. 9 SATA III Removable Drive 10 CFast Removable Drive DisplayPort 11 Battery Slot Digital I/O 12 PCIe (Generation 3) Expansion Shielded Required Attribute Shielded Connect the shielded I/O cables to your 6300B box PC or 6300T thin client. See Table 3 for I/O port locations and the required attribute of each cable. Connect the DC power to your 6300B box PC or 6300T thin client. Light-emitting diode (LED) status indicators illuminate on your 6300B box PC or 6300T thin client. For a description of these LED status indicators, see LED Status Indicators and Buttons on page 9. 6 UPS Connection future option 1 2 UPS Connection future option 2 Top View Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 — ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions Technical Data Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Figure 2 - 6300B-xxA and 6300T-BAx 6300B-BMA, 6300T-BAB Front View (Vertical Upright) 4.50 (0.18) 39.40 (1.55) 6300B-DRA, 6300T-BAD Front View (Vertical Upright) Side View Side View 8.00 (0.31) 1.50 (0.06) 4x Ø4.00 (0.16) 127.50 (5.02) 39.54 (1.56) 100.00 (3.94) 20.00 (0.79) 101.50 (4.00) 33.90 (1.33) 100.00 (3.94) 32.34 (1.27) 100.00 (3.94) 100.00 (3.94) 33.76 (1.33) 8.00 (0.31) 20.00 (0.79) 6.95 (0.27) 8.00 (0.31) 36.00 (1.42) 25.50 (1.00) 20.00 (0.79) 6.95 (0.27) Figure 3 - 6300B-BMB Box PC 6300B-BMBDNH*, 6300B-BMBDNI*, and 6300B-BMBDNJ* Front View (Vertical Upright) Side View 6300B-BMBDNE*, 6300B-BMBDNF*, 6300B-BMBDNG* Front View (Vertical Upright) Side View 4.20 (0.17) 5.50 (0.22) 5.50 4x Ø4.00 4x Ø 9.00 (0.35) (0.16) (0.22) 19.00 (0.75) 256.50 (10.10) 268.00 (10.55) 4.50 (0.18) 20.00 (0.79) 50.00 (1.97) 90.00 (3.54) 19.00 (0.75) 6.00 (0.24) 225.00 (8.86) Top View 20.00 (0.79) 256.50 (10.10) 268.00 (10.55) 230.00 (9.06) 25.00 (0.98) 19.00 (0.75) 100.00 (3.94) 150.00 (5.91) 4.00 (0.16) 230.00 (9.06) 19.00 (0.75) 6.00 25.00 (0.24) (0.98) 225.00 (8.86) Top View 150.00 (5.91) 90.00 (3.54) (in.)] Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 7 ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions Figure 4 - 6300B-BMF, 6300B-BMN, and 6300T-BBB 6300B-BMF Front View (Vertical Upright) 15.00 (0.59) 47.00 (18.50) 4.50 (1.85) 15.00 (0.59) 6300B-BMN, 6300T-BBB Front View (Vertical Upright) Side View 2.00 (0.08) 100.00 (3.94) 20.00 (0.79) 15.00 (0.59) 4.50 (1.77) 15.00 (0.9) 47.00 (1.85) 4x Ø4.00 (1.57) 20.00 (0.79) Side View 2.00 (0.79) 100.00 (3.94) 10.00 (0.39) 100.00 (3.94) 140.00 (5.51) 127.25 (5.00) 140.00 (5.51) 20.00 (0.79) 8.25 (0.32) 117.25 (4.61) 8.25 (0.32) 77.00 (3.03) 100.00 (3.94) 20.00 (0.79) 77.00 (3.03) Figure 5 - 6300B-DRF, 6300B-DRN, and 6300T-BBD Front View (Vertical Upright) 79.00 (3.11) 6300B-DRF 2.00 (0.08) Front View (Vertical Upright) Side View 2.00 (0.08) 79.00 (3.11) 100.00 (3.94) 50.00 (1.97) 26.00 (1.02) 26.00 (1.02) 100.00 (3.94) 47.00 (1.85) 8.50 (0.33) 50.00 (1.97) 100.00 (3.94) 100.00 (3.94) 47.00 (1.85) 20.00 (0.79) 20.00 (0.79) 27.00 (1.06) 100.00 (3.94) 23.00 (0.91) 23.00 (0.91) 100.00 (3.94) 6300B-DRN, 6300T-BBD Side View 26.00 (1.02) 27.00 (1.06) 26.00 (1.02) 20.00 (0.79) 8.50 (0.33) Battery Specifications AVERTISSEMENT: Risque d'explosion. Les piles ne doivent être remplacées que dans une zone exempte de concentrations de gaz inflammables. WARNING: Explosion hazard. Batteries must only be replaced in an area free of ignitable gas concentrations. Battery 8 Type Coin cell IEC Model No. CR2032 Voltage 3V Electrochemical System Lithium Battery Pack (accessory) Rating NiMH Voltage 12V Amperage 2500 mAh Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 ASEM 6300B Box PCs and 6300T Thin Clients Installation Instructions LED Status Indicators and Buttons ATTENTION: When you connect power to your box PC or thin client for the first time, these actions occur: • The default UEFI setting automatically starts your box PC or thin client after it is plugged into a power source. • For 6300B box PCs with a Microsoft Windows® operating system (OS), you must read and accept an End-User Setup procedure. Do not disconnect power from the system until after the Microsoft Windows Setup procedure is completed. If power is disconnected during this procedure, it can result in a corrupted system image. ‘’ Table 4 - Description of LED Status Indicators and Buttons Cat. No. Note No. 6300B-BMB Box PCs 1 Front View (Vertical Upright) 2 3 4 5 2 1 8 POWER UPS HDD OT/LB 6 10 11 WD PLC 7 3 9 BUS 4 5 Top View 13 12 13 12 Description Color Status/Function No Color The box PC or thin client is powered off. Power On Green The box PC or thin client is powered on. Yellow The box PC or thin client is safe to power off; the OS has been shut down successfully. No Color No UPS battery pack is installed. Green The box PC or thin client is powered by an external 24V DC source. UPS (optional) Yellow The UPS battery pack is disconnected. Flashing Green The external 24V DC source is lost, and the box PC or thin client is powered by the UPS. When lit, access to a mass storage device (SSD or CFast) is happening through a Mass Storage Yellow SATA channel. A thermal sensor on the motherboard near the CPU has exceeded the thermal limit of Red 85 °C (185 °F). Thermal Alarm / Low Battery The real-time clock (RTC) battery is lower than 2.5V. Replace before the battery goes lower Flashing Red and risks loss of date and time. Green The watchdog is working. Watchdog Red The watchdog timer has expired. 6 PLC 7 BUS 8 9 — Not applicable. Power On Button — System Reset — 10 Watchdog Reset — Turns the box PC on or off. Forces an internal reset, as if power was lost temporarily and then returned. IMPORTANT: Use system reset only if there are no better options, like keyboard or mouse commands. System reset can cause data loss and corruption to the OS. Turns off the watchdog LED (Note No. 5). 11 PLC Run / Stop / Reset — Not implemented. 12 Datalink No Color No Datalink is present. Green Datalink is established. Flashing Green Datalink is established and there is data transfer. 13 6300B (-BMA, -BMF, -BMN, -DRF, -DRN) Box PCs and 6300T Thin Clients Front View (Vertical Upright) 1 2 3 4 7 RST 5 WDR 6 Data Speed 1 Standby / Power On 2 Mass Storage 3 ⚠ 4 Thermal Alarm/ Low Battery 5 Power / System Reset 6 WDR 7 Datalink 8 No Color 10 Mbps Green 100 Mbps Yellow 1000 Mbps (1 Gbps) No color Green Yellow The box PC or thin client is powered off. The box PC or thin client is powered on. The box PC or thin client is safe to power off; the OS has been shut down successfully. The box PC or thin client is in a low-power state; the current session information is being Flashing Green stored in RAM. Yellow When lit, access to a mass storage device (SSD or CF) is happening through a SATA channel. — Not implemented. A thermal sensor on the motherboard near the CPU has exceeded the thermal limit of Red 85 °C (185 °F). The clock battery power is below 2.5V; consider replacing. Flashing Red IMPORTANT: At 2V, data and time loss is possible. For the main reset of the system. — Press this button once to restart and reset the system state. — Not implemented. No color No Datalink is present. Green Datalink is established. Flashing Green Datalink is established and there is data transfer. 8 Data Speed No color 10 Mbps Green 100 Mbps Yellow 1000 Mbps (1 Gbps) Rockwell Automation Publication 6300B-IN001H-EN-P - June 2024 9 Additional Resources This publication provides basic installation instructions. For more information, see the following Rockwell Automation publications at https://rok.auto/literature. Resource Description ASEM 6300B Book/DIN Mount Box PCs and 6300T Book/ DIN Mount Thin Clients User Manual, publication 6300B-UM001 Provides details on how to install, configure, operate, and troubleshoot the 6300B book mount box PCs and 6300T book mount thin clients (Cat. Nos. 6300B-BMA, 6300B-BMB, and 6300T-BAx1). ASEM 6300B Wall Mount Box PCs User Manual, publication 6300B-UM002 Provides details on how to install, configure, operate, and troubleshoot the 6300B wall mount PCs (Cat. Nos. 6300B-PBCx and 6300B-PBDx). ASEM 6300B Machine Mount Box PC, publication 6300B-UM003 Provides details on how to install, configure, operate, and troubleshoot the 6300B machine mount box PCs (Cat. No. 6300B-MM). ASEM 6300 Industrial Computer and Monitor Specifications Technical Data, publication 6300-TD001 Provides technical specifications for ASEM 6300 industrial computers and monitors. Wall-mount and DIN Rail Brackets for 6300B Box PCs and 6300T Thin Clients, publication 6300V-IN002 Provides installation instructions to secure 6300V-BWALLA wall-mount brackets or 6300V-BDINA DIN Rail bracket to a 6300B box PC or 6300T thin client. FactoryTalk Edge Manager User Manual, publication 95055-UM007-EN-P FactoryTalk Edge Manager Quick Start Guide, publication 95055-QS003-EN-P Provides instructions on operating the FactoryTalk Edge Manager, applicable to these catalog numbers with EVE-OS installed: • 6300B-BMBDNE-3DBAE01FNNBNN-NN1S • 6300B-BMBDNE-7EDAE01FNNDNN-NN1S • 6300B-BMBDNE-3DBAE01NNNBNN-NN1S • 6300B-BMBDNE-7EDAE01NNNDNN-NN1S Provides quick start instructions for FactoryTalk Edge Manager, applicable to these catalog numbers with EVE-OS installed: • 6300B-BMBDNE-3DBAE01FNNBNN-NN1S • 6300B-BMBDNE-7EDAE01FNNDNN-NN1S • 6300B-BMBDNE-3DBAE01NNNBNN-NN1S • 6300B-BMBDNE-7EDAE01NNNDNN-NN1S Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines to install a Rockwell Automation industrial system. Product Certifications website, rok.auto/certifications Provides declarations of conformity, certificates, and other certification details. Waste Electrical and Electronic Equipment (WEEE) At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. For technical support, visit rok.auto/support. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 6300B-IN001H-EN-P - June 2024 | Supersedes Publication 6300B-IN001G-EN-P - January 2024 Copyright © 2024 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. *PN-592308* PN-592308 Vendor Code 80460002.07 DIR 10005614692 (Version 07) ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Rugged design
- Hazardous Location Compliance
- Industrial Ethernet
- Multiple I/O ports
- Expandibility Options
- Support for Different Processors
- FactoryTalk Edge Manager Compatibility
Frequently asked questions
The ASEM 6300B Box PC or 6300T Thin Client must be mounted in an enclosed panel when used in hazardous locations. It must be mounted vertically with at least 20 mm of clearance on each side for cooling.
The device requires a 24V DC power supply, but it can handle a range of 18V to 32V. It is important to note that using an AC power supply is not allowed in hazardous locations.
The operating temperature range depends on the processor used. For Intel Atom x5 processors, it's 0…55 °C (32…131 °F). For Intel Atom x7 and Intel Core i3, i5, and i7 processors, it's 0…50 °C (32…122 °F). The storage temperature range is -10…+60 °C (+14…+140 °F).