Allen-Bradley ArmorBlock 2-port EtherNet/IP Modules Installation Instructions
Allen-Bradley ArmorBlock 2-port EtherNet/IP Modules are sealed IP65, IP66, IP67, and IP69K modules that require no enclosure. This means that the module can be installed in a harsh environment like a factory floor, without needing to be housed in a separate enclosure. They are a reliable and robust choice for industrial applications. With the dual Ethernet ports and embedded Ethernet switch, they connect to your network easily, simplifying network installation.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Original Instructions ArmorBlock 2-port EtherNet/IP Modules Catalog Numbers 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R, 1732E-16CFGM12P5QCWR Topic Summary of Changes Before You Begin Install the Module Set the Network Address Mount the Module Connect the I/O, Network, and Auxiliary Cables to the Module Configure the Module Interpret Status Indicators Specifications Additional Resources Page 1 3 5 5 5 6 9 10 12 14 Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Added inclusive language acknowledgment Updated Certifications Page 2 14 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 岤䠑㖈㸝鄳ծꂁ縨ծ乼⡲ㄤ絶䫡劥❡ㅷ霼ꢓ靀劥俒咓⟄⿺ Ⱖ➭餴彂 鿈ⴔⴀ涸剣Ⱒ霃㢊㸝鄳ծꂁ縨ㄤ乼⡲涸湱䎾俒咓կꤑ✫䨾剣鷓欽錞薴ծ岁䖒ㄤ叻ⲥ涸 湱Ⱒ銳宠⛓㢪欽䨪鵮䗳곢擿䜪㸝鄳ㄤ䱹絁霹僈կ 㸝鄳ծ靈侮ծ䫏鵘ծ⢪欽ծ絆鄳ծ䬒⽸ㄤ絶䫡瘝ぐ고乼⡲䗳곢歋絑鵂鷓䔲雲絅涸⚁⚌➃プ䭽撑鷓欽涸乼⡲錞薴㹊倶կ 㥵卓劢䭽撑ⵖ鸣㉁䭷㹁涸倰䒭⢪欽霪霃㢊ⴭ〳腊⠔䰀㹲霃㢊䲿⣘涸⥂䫡կ ATENCIÓN: Antes de instalar, configurar, poner en funcionamiento o realizar el mantenimiento de este producto, lea este documento y los documentos listados en la sección Recursos adicionales acerca de la instalación, configuración y operación de este equipo. Los usuarios deben familiarizarse con las instrucciones de instalación y cableado y con los requisitos de todos los códigos, leyes y estándares vigentes. El personal debidamente capacitado debe realizar las actividades relacionadas a la instalación, ajustes, puesta en servicio, uso, ensamblaje, desensamblaje y mantenimiento de conformidad con el código de práctica aplicable. Si este equipo se usa de una manera no especificada por el fabricante, la protección provista por el equipo puede resultar afectada. ATENÇÃO: Leia este e os demais documentos sobre instalação, configuração e operação do equipamento que estão na seção Recursos adicionais antes de instalar, configurar, operar ou manter este produto. Os usuários devem se familiarizar com as instruções de instalação e fiação além das especificações para todos os códigos, leis e normas aplicáveis. É necessário que as atividades, incluindo instalação, ajustes, colocação em serviço, utilização, montagem, desmontagem e manutenção sejam realizadas por pessoal qualificado e especializado, de acordo com o código de prática aplicável. Caso este equipamento seja utilizado de maneira não estabelecida pelo fabricante, a proteção fornecida pelo equipamento pode ficar prejudicada. ВНИМАНИЕ: Перед тем как устанавливать, настраивать, эксплуатировать или обслуживать данное оборудование, прочитайте этот документ и документы, перечисленные в разделе «Дополнительные ресурсы». В этих документах изложены сведения об установке, настройке и эксплуатации данного оборудования. Пользователи обязаны ознакомиться с инструкциями по установке и прокладке соединений, а также с требованиями всех применимых норм, законов и стандартов. Все действия, включая установку, наладку, ввод в эксплуатацию, использование, сборку, разборку и техническое обслуживание, должны выполняться обученным персоналом в соответствии с применимыми нормами и правилами. Если оборудование используется не предусмотренным производителем образом, защита оборудования может быть нарушена. : ACHTUNG: Lesen Sie dieses Dokument und die im Abschnitt „Weitere Informationen“aufgeführten Dokumente, die Informationen zu Installation, Konfiguration und Bedienung dieses Produkts enthalten, bevor Sie dieses Produkt installieren, konfigurieren, bedienen oder warten. Anwender müssen sich neben den Bestimmungen aller anwendbaren Vorschriften, Gesetze und Normen zusätzlich mit den Installations- und Verdrahtungsanweisungen vertraut machen. Arbeiten im Rahmen der Installation, Anpassung, Inbetriebnahme, Verwendung, Montage, Demontage oder Instandhaltung dürfen nur durch ausreichend geschulte Mitarbeiter und in Übereinstimmung mit den anwendbaren Ausführungsvorschriften vorgenommen werden. Wenn das Gerät in einer Weise verwendet wird, die vom Hersteller nicht vorgesehen ist, kann die Schutzfunktion beeinträchtigt sein. ATTENTION : Lisez ce document et les documents listés dans la section Ressources complémentaires relatifs à l’installation, la configuration et le fonctionnement de cet équipement avant d’installer, configurer, utiliser ou entretenir ce produit. Les utilisateurs doivent se familiariser avec les instructions d’installation et de câblage en plus des exigences relatives aux codes, lois et normes en vigueur. Les activités relatives à l’installation, le réglage, la mise en service, l’utilisation, l’assemblage, le démontage et l’entretien doivent être réalisées par des personnes formées selon le code de pratique en vigueur. Si cet équipement est utilisé d’une façon qui n’a pas été définie par le fabricant, la protection fournie par l’équipement peut être compromise. : , , , . , . , , , , , , . . ATTENZIONE Prima di installare, configurare ed utilizzare il prodotto, o effettuare interventi di manutenzione su di esso, leggere il presente documento ed i documenti elencati nella sezione “Altre risorse”, riguardanti l’installazione, la configurazione ed il funzionamento dell’apparecchiatura. Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio, oltre ai requisiti previsti dalle leggi, codici e standard applicabili. Le attività come installazione, regolazioni, utilizzo, assemblaggio, disassemblaggio e manutenzione devono essere svolte da personale adeguatamente addestrato, nel rispetto delle procedure previste. Qualora l’apparecchio venga utilizzato con modalità diverse da quanto previsto dal produttore, la sua funzione di protezione potrebbe venire compromessa. DİKKAT: Bu ürünün kurulumu, yapılandırılması, işletilmesi veya bakımı öncesinde bu dokümanı ve bu ekipmanın kurulumu, yapılandırılması ve işletimi ile ilgili İlave Kaynaklar bölümünde yer listelenmiş dokümanları okuyun. Kullanıcılar yürürlükteki tüm yönetmelikler, yasalar ve standartların gereksinimlerine ek olarak kurulum ve kablolama talimatlarını da öğrenmek zorundadır. Kurulum, ayarlama, hizmete alma, kullanma, parçaları birleştirme, parçaları sökme ve bakım gibi aktiviteler sadece uygun eğitimleri almış kişiler tarafından yürürlükteki uygulama yönetmeliklerine uygun şekilde yapılabilir. Bu ekipman üretici tarafından belirlenmiş amacın dışında kullanılırsa, ekipman tarafından sağlanan koruma bozulabilir. 岤䠑✲갪㖈㸞酤鏤㹁乽⡲䧴笞隌劥欴ㅷ锞⯓ꠗ隡姽俒⟝⟃⿻倴 չⰦ➮须彂պ畎眏⚥剤ꡠ㸞酤鏤㹁莅乽⡲姽鏤⪔涸俒⟝⢪欽罏䗳갭擿䜫㸞酤ㄤꂂ箁䭸 爚⚛痘ざ䨾剤岁鋊岁䖒ㄤ垦彋銴宠 ⺫䭍㸞酤锅侮❜➰⢪欽⢪欽穉酤䬓⽹ㄤ笞隌瘞⹛⡲鿪䗳갭❜歋䊺竤麕黠殹鎯箻涸➃㆞鹎遤⟃痘ざ黠欽涸㻜⡲岁鋊 㥶卓㼟鏤⪔欽倴ꬌ醢鸤㉂䭸㹁涸欽鸁儘〳腋剚鸤䧭鏤⪔䨾䲿⣘涸⥃隌⸆腋「䴦 POZOR: Než začnete instalovat, konfigurovat či provozovat tento výrobek nebo provádět jeho údržbu, přečtěte si tento dokument a dokumenty uvedené v části Dodatečné zdroje ohledně instalace, konfigurace a provozu tohoto zařízení. Uživatelé se musejí vedle požadavků všech relevantních vyhlášek, zákonů a norem nutně seznámit také s pokyny pro instalaci a elektrické zapojení. Činnosti zahrnující instalaci, nastavení, uvedení do provozu, užívání, montáž, demontáž a údržbu musí vykonávat vhodně proškolený personál v souladu s příslušnými prováděcími předpisy. Pokud se toto zařízení používá způsobem neodpovídajícím specifikaci výrobce, může být narušena ochrana, kterou toto zařízení poskytuje. UWAGA: Przed instalacją, konfiguracją, użytkowaniem lub konserwacją tego produktu należy przeczytać niniejszy dokument oraz wszystkie dokumenty wymienione w sekcji Dodatkowe źródła omawiające instalację, konfigurację i procedury użytkowania tego urządzenia. Użytkownicy mają obowiązek zapoznać się z instrukcjami dotyczącymi instalacji oraz oprzewodowania, jak również z obowiązującymi kodeksami, prawem i normami. Działania obejmujące instalację, regulację, przekazanie do użytkowania, użytkowanie, montaż, demontaż oraz konserwację muszą być wykonywane przez odpowiednio przeszkolony personel zgodnie z obowiązującym kodeksem postępowania. Jeśli urządzenie jest użytkowane w sposób inny niż określony przez producenta, zabezpieczenie zapewniane przez urządzenie może zostać ograniczone. OBS! Läs detta dokument samt dokumentet, som står listat i avsnittet Övriga resurser, om installation, konfigurering och drift av denna utrustning innan du installerar, konfigurerar eller börjar använda eller utföra underhållsarbete på produkten. Användare måste bekanta sig med instruktioner för installation och kabeldragning, förutom krav enligt gällande koder, lagar och standarder. Åtgärder som installation, justering, service, användning, montering, demontering och underhållsarbete måste utföras av personal med lämplig utbildning enligt lämpligt bruk. Om denna utrustning används på ett sätt som inte anges av tillverkaren kan det hända att utrustningens skyddsanordningar försätts ur funktion. LET OP: Lees dit document en de documenten die genoemd worden in de paragraaf Aanvullende informatie over de installatie, configuratie en bediening van deze apparatuur voordat u dit product installeert, configureert, bediend of onderhoudt. Gebruikers moeten zich vertrouwd maken met de installatie en de bedradingsinstructies, naast de vereisten van alle toepasselijke regels, wetten en normen. Activiteiten zoals het installeren, afstellen, in gebruik stellen, gebruiken, monteren, demonteren en het uitvoeren van onderhoud mogen uitsluitend worden uitgevoerd door hiervoor opgeleid personeel en in overeenstemming met de geldende praktijkregels. Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant, dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt. Rockwell Automation recognizes that some of the terms that are currently used in our industry and in this publication are not in alignment with the movement toward inclusive language in technology. We are proactively collaborating with industry peers to find alternatives to such terms and making changes to our products and content. Please excuse the use of such terms in our content while we implement these changes. 2 Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Environment and Enclosure ATTENTION: This equipment is intended for use in overvoltage Category II applications (as defined in EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments. This equipment is supplied as Type 1 enclosed equipment (only when provided with dust cap on the Input and Output connectors or terminated with cables). It should not require additional system enclosure when used in locations consistent with the equipment Enclosure Type Ratings. Subsequent sections of this publication may contain more information regarding specific enclosure type ratings, beyond what this product provides, that are required to comply with certain product safety certifications. In addition to this publication, see the following: • Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for additional installation requirements. • NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures. ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle the module. Prevent Electrostatic Discharge ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • Use a static-safe workstation, if available. • Store the equipment in appropriate static-safe packaging when not in use. ATTENTION: • Make sure that all connectors and caps are securely tightened to properly seal the connections against leaks and maintain Type 1 and IP enclosure type requirements. • Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. • Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle the module. • Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents. Electrical Safety Considerations ATTENTION: This device is intended only for installation on Industrial Machines in accordance with NFPA79. Due to the nature of these devices (fixed equipment using cable connections) they are not suitable for installation in accordance with the NEC (NFPA70). Before You Begin The ArmorBlock® I/O modules communicate via EtherNet/IP™. The sealed IP65, IP66, IP67, and IP69K housing of these modules requires no enclosure. The I/O modules have dual Ethernet ports and use an embedded Ethernet switch. See Figure 1 to familiarize yourself with major parts of the module. Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 3 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Figure 1 - Module Identification 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R 1732E-16CFGM12P5QCWR 1 2 1 1 LINK 1 PORT 1 LINK 1 LINK 2 MOD NET PORT 2 3 LINK 2 5 3 4 5 5 8 4 8 7 7 6 AUX POWER Component Description 1 Description EtherNet/IP D-coded M12 connector 5 Description M12 style I/O connectors 2 Functional Earth(1) 6 Mini-style auxiliary power out 3 Status indicators 7 4 Node address switches 8 Protective Earth(2) Mini-style auxiliary power in (1) Functional earth grounds the I/O block EtherNet/IP communication circuitry, which is designed to mitigate the effect of noise on the network. See EtherNet/IP Connector on page 8. (2) Protective earth is provided for the grounding of field devices and is internally connected to each Pin 5 of the M12 I/O connectors. See I/O Connectors on page 7. Catalog Number Explanation Catalog Number 1732E-IB16M12R 1732E-OB16M12R 1732E-IB16M12DR 1732E-OB16M12DR 1732E-16CFGM12R 1732E-IB16M12SOEDR 1732E-16CFGM12P5QCWR 4 Description Network Connector 16 channel 24V DC digital input dual-port Ethernet/IP module 16 channel 24V DC digital output dual-port Ethernet/IP module Dual D-coded M12 16 channel 24V DC digital input dual-port Ethernet/IP module with sensor source diagnostics 16 channel 24V DC digital output dual-port Ethernet/IP module with individually fused outputs and diagnostics 16 channel 24V DC self-configurable I/O dual-port Ethernet/IP module with individually fused outputs Dual D-coded M12 16 channel 24V DC digital I/O dual-port Ethernet/IP with sensor source diagnostics and Sequence of Events support 16 channel 24V DC self-configurable digital I/O dual-port Ethernet/IP metal WeldBlock module with QuickConnect Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 Auxiliary Power Single 4-pin mini Single 4-pin mini Dual 5-pin mini ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Install the Module To install the module: 1. 2. 3. Set the Network Address Mount the Module Connect the I/O, Network, and Auxiliary Cables to the Module Set the Network Address The I/O block ships with the rotary switches set to 999 and Dynamic Host Configuration Protocol (DHCP) enabled. To change the network address, you can do one of the following: • • • Adjust the switch on the front of the module. Use a DHCP server, such as Rockwell Automation® BootP/DHCP. Retrieve the IP address from nonvolatile memory. The I/O block reads the switches first to determine if the switches are set to a valid number. To set the network address: 1. 2. 3. 4. Rotate the three switches on the front of the module using a small blade screwdriver. Align the small notch on the switch with the number setting you wish to use. Valid settings range from 001…254. Cycle power. Set Network Address Example shows the default node address set at 163. When the switches are set to a valid number, the I/O block IP address is 192.168.1.xxx (where xxx represents the number set on the switches). The I/O block subnet mask is 255.255.255.0 and the gateway address is set to 0.0.0.0. When the I/O block uses the network address set on the switches, the I/O block does not have a host name assigned to it or use any Domain Name Server. If the switches are set to an invalid number (for example, 000 or a value greater than 254 excluding 888), the I/O block checks to see if DHCP is enabled. If DHCP is enabled, the I/O block asks for an address from a DHCP server. The DHCP server also assigns other Transport Control Protocol (TCP) parameters. If DHCP is not enabled, the I/O block uses the IP address (along with other TCP configurable parameters) stored in nonvolatile memory. Mount the Module Two sets of mounting holes are used to mount the module directly to a panel or machine. Mounting holes accommodate #8 (M4) pan head screws. The torque specification is 1.13 N•m (10 lb•in). Product Dimensions See Figure 2 for the mounting dimensions illustration to help you mount the module. Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 5 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Figure 2 - Module Dimensions 1732E-16CFGM12P5QCWR 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R 65 mm (2.56 in.) 60.4 mm (2.38 in.) 43.25 mm (1.70 in.) 26.5 mm (1.04 in.) 28 mm (1.1 in.) PORT 1 LINK 1 45 mm (1.77 in.) LINK 1 LINK 2 MOD NET PORT 2 LINK 2 200 mm (7.87 in.) 179 mm (7.05 in.) 189.6 mm (7.46 in.) 169 mm (6.65 in.) AUX POWER Front view Side view Front view Side view Mount the Module in High Vibration Areas If you mount the module in an area that is subject to shock or vibration, we recommend you use a flat and a lock washer to mount the module. Mount the flat and the lock washer as shown in the mounting illustration. Torque the mounting screws to 1.13 N•m (10 lb•in). Figure 3 - High Vibration Area Mounting Lock washer Flat washer Connect the I/O, Network, and Auxiliary Cables to the Module The ArmorBlock EtherNet/IP family has 5-pin micro-style connectors. We provide caps to cover the unused connectors on your module. Connect the quick-disconnect cord sets you selected for your module to the appropriate ports. 6 Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions I/O Connectors See the pinout diagrams for the I/O connectors. Figure 4 - Micro-style 5-pin input Female Connector 1 2 5 4 3 View into Connector Pin 1 2 3 4 5 Function Sensor source voltage Input B Return Input A Protective Earth Figure 5 - Micro-style 5-pin Output Female Connector 1 2 5 4 3 View into Connector Pin 1 2 3 4 5 Function Not used Output B Return Output A Protective Earth Self-configuring Modules The 1732E-16CFGM12R and 1732E-16CFGM12P5QCWR self-configuring modules contain both input and output functionality. • • • If an I/O point is to be an output, dedicate that point as an output with a wired load and energize it through a control program. Energized outputs show an associated active input that can be used as a feedback mechanism to verify that the output is On. If an I/O point is to be an input, wire the input device as normal and leave the associated output de-energized at all times. Figure 6 - Micro-style 5-pin Selectable Point Connector 1 2 5 4 3 View into Connector Pin 1 2 3 4 5 Function Sensor source voltage Input or Output B Return Input or Output A Protective Earth ATTENTION: Make sure that all connectors and caps are securely tightened to properly seal the connections against leaks and maintain Type 1 and IP enclosure and requirements. I/O Self-configure Circuitry Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 7 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions EtherNet/IP Connector Figure 7 - D-coded Micro Network Female Connector Pin Function 1 M12_Tx+ 2 M12_Rx+ 3 M12_Tx- 3 4 M12_Rx- View into Connector 1 5 Connector shell shield ground Pin Function 1 M12_Rx+ 2 M12_Tx+ 5 1 4 2 3 2 4 3 M12_Rx- 5 4 M12_Tx- View into Connector 2 5 Connector shell shield ground 1 IMPORTANT Use one of the following mating connectors for the D-coded M12 female network connector: • Polyamide small body unshielded (1585D–M4DC–H) • Zinc die-cast large body shielded (1585D–M4DC–SH) Enable QuickConnect To enable QuickConnect for the Ethernet ports, use the RSLogix 5000® or Studio 5000 Logix Designer® application Module QuickConnect tab and check the Enable QuickConnect option. For more information on the QuickConnect system setup, see EtherNet/IP QuickConnect Application Technique, publication ENET-AT001. After the QuickConnect feature is set to ON, the module must be power cycled. QuickConnect is active during the next connection. Once active, the QuickConnect feature automatically sets all Ethernet ports to: • • • • Speed = 100 Mbps Duplex = Full Auto-negotiate = Off Automatic Cross-over Cable Detection (auto-MDIX) = Off If you configure BootP/DHCP, QuickConnect changes the configuration to retain the current IP address. Disabling the QuickConnect feature automatically sets all Ethernet ports to Automatic Cross-over Cable Detection (auto-MDIX) = On. To reset the Ethernet ports to Auto-negotiate or the IP address to DHCP request, do one of the following: • • • Change the setting on the module webpage Change the setting in the RSLogix 5000 or Studio 5000 Logix Designer application Perform a factory reset Auxiliary Power Connector The 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-OB16M12R, 1732E-OB16M12DR, and 1732E-16CFGM12R modules use 4-pin auxiliary power connections. Attach the mini-style 4-pin connector to the mini-style 4-pin receptacle as shown in Figure 8. Figure 8 - Mini-style 4-pin Receptacle Male Input 4 3 Female Output 2 1 View into Connector 1 8 Pin Function 1 Output power+ 2 Sensor/MDL power+ 3 Sensor/MDL power- 4 Output power- Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 2 4 1 3 View into Connector 1 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions The 1732E-16CFGM12P5QCWR module use 5-pin auxiliary power connections. Attach the mini-style 5-pin connector to the mini-style 5-pin receptacle as shown in Figure 9. Figure 9 - Mini-style 5-pin Receptacle Male Input 5 1 Female Output Pin Function 1 Output power- 2 Sensor/MDL power- 5 4 3 Protective Earth 3 4 Sensor/MDL power+ View into Connector 1 5 Output power+ 2 4 1 2 3 View into Connector 1 The grounds for both module power and output power are shared. ATTENTION: This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbance. Auxiliary power is based on a 4-pin and 5-pin connector system and is used to provide 24V DC power to I/O modules and other devices. Running separate power to these devices is most typically used for I/O devices with output connections to prevent power supply interruption due to switching of outputs. However, some devices require separate auxiliary power to power them regardless of the presence of outputs. Depending on the devices used, it may be possible to provide power through only one pair of the four available pins, and in this case the other available pair may be used for single channel E-stop by using special E-stop drop or power T-ports and shorting plugs. Allen-Bradley® E-stop T-ports and shorting plugs are red for easy identification. Configure the Module See Figure 10 for configuration operations. Figure 10 - Configure Operations 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R EtherNet/IP D-coded M12 connector LINK 1 1732E-16CFGM12P5QCWR EtherNet/IP D-coded M12 connector LINK 2 PORT 1 LINK 1 LINK 2 MOD NET PORT 2 EtherNet/IP D-coded M12 connector Node address switches M12 style I/O connectors Mini-style auxiliary power in M12 style I/O connectors Node address switches Mini-style auxiliary power in M12 style I/O connectors Mini-style auxiliary power out AUX POWER See Essential Components Selection Guide, publication EC-CA100, for Rockwell Automation cable and cord set offerings or use the Product Selection and Configuration tools available at rok.auto/systemtools. Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 9 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions External Repository for Random Data (ERRD) The QuickConnect modules provide onboard nonvolatile memory, of up to 6K bytes, for storing block-specific data such as Tool ID and counter value. You can read from and write to the module memory. To read from the module 1. Send an EtherNet/IP Explicit Message with the following information: Service Code Class ID Instance ID Attribute ID Request Data 4C (hex) 6E (hex) 1 1 Data Payload (total 8 bytes): Offset Description 0x00 Address to Read from 0x04 Number of bytes to read (max 472 bytes) To write to the module 2. Send the following three EtherNet/IP Explicit Messages: Start Command Service Code Class ID Instance ID Attribute ID 06 (hex) 6E (hex) 1 1 Write Command Service Code 4D (hex) Class ID 6E (hex) Instance ID 1 Attribute ID 1 Data Payload (max 8+ 472 bytes): Offset Description Request Data 0x00 Address to Write to 0x04 Number of bytes to write (max 472 bytes) 0x08 User Data (Array of USINT) Stop Command Service Code Class ID Instance ID Attribute ID 07 (hex) 6E (hex) 1 1 Interpret Status Indicators This module has the following indicators: • • • 10 Network, Module, and Link status indicators for EtherNet/IP Auxiliary Power indicator Individual I/O status indicators for inputs and outputs Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Figure 11 - Status Indicators 1732E-16CFGM12P5QCWR 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R Network link status LINK 1 LINK 2 Network status indicator Module status indicator Network link status Module status indicator PORT 1 LINK 1 LINK 2 MOD NET PORT 2 Network status indicator Input status indicators I/O status indicators I/O status indicators Output status indicators Power status indicator AUX POWER Indicator Status for Modules Indicator Module status Status Off Flashing red/green Green Flashing red Red Off Flashing green Network status Network link status Power status Digital output status(1) Digital input status Green Flashing red Red Flashing red/green Off Green Flashing green Yellow Flashing yellow Off Green Off Yellow Red Flashing red Off Yellow Red Flashing red Description No power is applied to the device. The device is in self-test. The device is operating normally. Recoverable fault An unrecoverable fault – May require device replacement. The device is not initialized or the module does not have an IP address. The device has no CIP™ connections. The device has an IP address, but no CIP connections are established. The device is online, has an IP address, and CIP connections are established. One or more connections have timed out. The module has detected that its IP address is already in use. The module is performing a power-up self-test. No link is established. Link is established on the indicated port at 100 Mbps. Link activity is present on the indicated port at 100 Mbps. Link is established on the indicated port at 10 Mbps. Link activity is present on the indicated port at 10 Mbps. No power to the device or input not valid The power is applied to the device. The output is not energized. The output is energized and the output power is applied. The output is shorted. The output is open load condition. No valid input Valid input The sensor source voltage is shorted. The sensor source has an open wire condition. (1) Only the 1732E-IB16M12SOEDR diagnostic module has red I/O status indicators. IMPORTANT In non-QuickConnect mode, the module status indicator flashes red and green for a max of 5 s while the module completes a POST (power on self test). Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 11 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Specifications Input Specifications — 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-16CFGM12R, 1732E-16CFGM12P5QCWR Attribute Number of inputs Input type Voltage, off-state input, max Voltage, on-state input, min Voltage, on-state input, nom Voltage, on-state input, max Current, off-state input, max Current, on-state input, max Voltage, sensor source, min Voltage, sensor source, max Input delay time On to Off Off to On Isolation voltage 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-16CFGM12R 1732E-16CFGM12P5QCWR 16 Sink, 24V DC 5V DC 12V DC 24V DC 30V DC 1.5 mA @ 5V DC 5 mA @ 30V DC 10V DC 30V DC 0…16000 µs 0, 1, 2, 4, 8, 16 ms 50V (continuous), basic insulation type, inputs, and sensor power to the network. No isolation between individual Inputs or between network channels. Type tested at 707V DC for 60 s. No isolation Output Specifications — 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R, 1732E-16CFGM12P5QCWR Attribute 1732E-OB16M12R 1732E-OB16M12DR 1732E-16CFGM12R Number of outputs 16 Output type Source, 24V DC Voltage drop, on-state output, max 0.5V DC Voltage off-peak blocking, min 30V DC Voltage, on-state output, min 12V DC Voltage, on-state output, nom 24V DC Voltage, on-state input, max 30V DC Current, on-state output, max 2.0 A 0.5 A Current per module, max 8.0 A Leakage current, off-state output, 50 µA 500 µA 50 µA max 4.8 A for 10 ms, repeatable Surge current per output, min 1.2 A for 10 ms, repeatable every 2 s every 2 s Pilot duty rating DC-14 50V (continuous), basic insulation type, outputs, and output power to the network. No isolation between individual outputs or between outputs and output power Isolation voltage or between network channels. Type tested at 707V DC for 60 s 1732E-16CFGM12P5QCWR — No isolation General Specifications Attribute 1732E-IB16M12DR, 1732E-OB16M12R, 1732E-OB16M12DR 1732E-IB16M12R, 1732E-IB16M12SOEDR, 1732E-16CFGM12R 1732E-16CFGM12P5QCWR 30V DC 12V DC Voltage, auxiliary power, max Voltage, auxiliary power, min Current, Ethernet system power, max 0.4 A (pins 2, 3 sensor source/module power) Current, auxiliary power, max per output module (pins 2, 3 sensor source/module power plus 8 A pins 1, 4 for output loads) Current, auxiliary power connector, max 10 A per module Current, sensor source, per input, max 50 mA Current, sensor source, per connector, max 100 mA 12 1.2 A Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 1.0 A ArmorBlock 2-port EtherNet/IP Modules Installation Instructions General Specifications (Continued) Attribute Communication rate Status indicators Dimensions (HxWxD), approx. Weight, approx. Enclosure type rating Wiring category(1) (2) Onboard memory type Onboard memory, capacity, max 1732E-IB16M12DR, 1732E-OB16M12R, 1732E-OB16M12DR 1732E-IB16M12R, 1732E-IB16M12SOEDR, 1732E-16CFGM12R 1732E-16CFGM12P5QCWR EtherNet/IP 10/100 Mbps Full or half-duplex 100 m (328 ft) per segment Module status - Red/green Network status - Red/green Link status - Green/yellow Auxiliary power - Green I/O channels - Yellow I/O channels - Yellow/red – 1732E-IB16M12SOEDR only 179 x 65 x 43.25 mm (7.05 x 2.56 x 1.70 in.) 200 x 60.4 x 45 mm (7.87 x 2.38 x 1.77 in.) 340 kg (11.99 oz.) 510 g (17.99 oz.) Meets IP65/67/69K (when marked), and Type 1 with receptacle dust caps or cable termination. 1 – On signal ports 1 – On power ports 1 – On communications port Ferroelectric Nonvolatile RAM (FRAM) 6K bytes (1) Use this conductor category information for planning conductor routing as described in Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) Use this Conductor Category information for planning conductor routing as described in the appropriate System Level Installation Manual. Environmental Specifications Attribute Temperature, operating Temperature, ambient, max Temperature, nonoperating Relative humidity Vibration Shock, operating Shock, nonoperating Emissions ESD immunity Radiated RF immunity EFT/B immunity Surge transient immunity Conducted RF immunity 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-16CFGM12P5QCWR 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20 °C < Ta < +60 °C (-4 °F < Ta < +140 °F) 60 °C (140 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40…+85 °C (-40…+185 °F) IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5…95% noncondensing IEC60068-2-6 (Test Fc, Operating): 5 g @ 10…500 Hz EC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g EC 60068-2-27 (Test Ea, Unpackaged Shock): 50 g IEC 61000-6-4 IEC6100-4-2: 6 kV contact discharges 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz IEC 61000-4-4: ±4 kV @ 5 kHz on power ports ±4 kV @ 5 kHz on power ports ±3 kV @ 5 kHz on signal ports ±2 kV @ 5 kHz on signal ports ±3 kV @ 5 kHz on communications ports ±2 kV @ 5 kHz on communications ports IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports ±2 kV line-earth(CM) on communications ports ±2 kV line-earth(CM) on shielded ports IEC61000-4-6: 10V rms with 1 kHz sine-wave 80%AM from 150 kHz…80 MHz Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 13 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Certifications Certification (when product is marked)(1) c-UL-us CE RCM KC Morocco UKCA EtherNet/IP Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. European Union 2014/30/EU EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61131-2; Programmable Controllers EN 61000-6-4; Industrial Emissions European Union 2011/65/EU RoHS, compliant with: EN IEC 63000; Technical documentation Australian Radiocommunications Act, compliant with: AS/NZS CISPR11; Industrial Emissions. Korean Registration of Broadcasting and Communications Equipment, compliant with: Article58-2 of Radio Waves Act, Clause 3 Arrêté ministériel n° 6404-15 du 29 ramadan 1436 2016 No. 1091 – Electromagnetic Compatibility Regulations 2012 No. 3032 – Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations ODVA conformance tested to EtherNet/IP specifications. (1) See the Product Certification link at rok.auto/certifications for Declaration of Conformity, Certificates, and other certification details. Additional Resources For more information on the products that are described in this publication, use these resources. You can view or download publications at rok.auto/literature. Resource 1732E EtherNet/IP ArmorBlock Supporting Sequence of Events, publication 1732E-UM002 EtherNet/IP QuickConnect Application Technique, publication ENET-AT001 Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website: rok.auto/certifications 14 Description Detailed description of how to use and configure your 1732E-IB16M12SOEDR module. Detailed explanation on how to set up and use QuickConnect ArmorBlock modules. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 ArmorBlock 2-port EtherNet/IP Modules Installation Instructions Notes: Rockwell Automation Publication 1732E-IN009D-EN-P - June 2024 15 Rockwell Automation Support Use these resources to access support information. Technical Support Center Find help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates. Local Technical Support Phone Numbers Locate the telephone number for your country. rok.auto/support rok.auto/phonesupport Technical Documentation Center Quickly access and download technical specifications, installation instructions, and user manuals. rok.auto/techdocs Literature Library Find installation instructions, manuals, brochures, and technical data publications. rok.auto/literature Product Compatibility and Download Center (PCDC) Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes. rok.auto/pcdc Documentation Feedback Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. Waste Electrical and Electronic Equipment (WEEE) At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, ArmorBlock, expanding human possibility, Rockwell Automation, RSLogix 5000, Studio 5000 Logix Designer, and TechConnect are trademarks of Rockwell Automation, Inc. CIP and EtherNet/IP are trademarks of ODVA, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1732E-IN009D-EN-P - June 2024 | Supersedes Publication 1732E-IN009C-EN-P - November 2021 Copyright © 2024 Rockwell Automation, Inc. All rights reserved. ">
Key Features
- Sealed IP65, IP66, IP67, IP69K housing
- Dual Ethernet ports
- Embedded Ethernet switch
- 16 Channel I/O
- QuickConnect capability
- Nonvolatile memory for data storage
Frequently Answers and Questions
How do I set the network address for the module?
You can set the network address using the rotary switches on the front of the module, use a DHCP server, or retrieve the IP address from nonvolatile memory.
What are the mounting dimensions of the module?
You can find the mounting dimensions in Figure 2 of the manual.
How do I configure the module for QuickConnect?
Use the RSLogix 5000 or Studio 5000 Logix Designer application Module QuickConnect tab and check the Enable QuickConnect option.