Bul. 140G2
DIR 1000999R0505 Version 01 - 140G2-N-CIM, 140G2-N-VB3,140G2-N-VB4, 140G2-N-VT3, 140G2-N-VT4
Measuring Module and Cables for 140G2-N, 140G2-NS
Modulo di misura e cavi
Messmodul und Kabel
Módulo de medición y cables
Módulo de medição e cabos
Installation - Installazione - Installation - Installation Instalación - Instalação WARNING: To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
(Follow NFPA 70E requirements
Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire
appropriée. Protéger le produit contre les environnements agressifs.
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes.
140G2-N
140MG2-N
Clack!
140G2-NS
Clack!
Required Tools
A1
A2
B1
B2
C
D
E
F
xx lb-in
xx Nm
TX 10
Length
Cable
Cable
Cable
Cable
(short, 3p) (long, 3p) (short, 4p) (long, 4p)
Length
Dia.
3mm
8mm
(0.315") (0.118")
PH 1
PH 2
TX 8
Dia.
12 mm
3mm
(0.472" ) (0.118")
Screw
(cable)
Measuring
Module
140G2-N-CIM
Screw
(module)
xx lb-in
xx Nm
1
-
-
-
3
-
-
-
-
1
-
-
3
-
-
1
4p
-
-
1
-
4
-
-
-
4p
140G2-N-VB4 Bottom (SPARE)
-
-
-
1
4
-
-
1
140G2-N-CIM
-
-
-
-
-
1
2
-
140G2-N-VT3
Top
3p
3p
140G2-N-VB3 Bottom (SPARE)
140G2-N-VT4
Top
Publication 140G-IN169B-EN-P - April 2021
TX 6
TX 8
TX 10
Measuring Module and Cables for 140G2-N, 140G2-NS
2
1
3
140G2-NS
PH 1
PH 2
Example 140G2-NS
140G2-N
2
4
PH 1
5
TX 8
TX 6
6
1
2
Publication 140G-IN169B-EN-P - April 2021
PH 1
PH 2
DIR 1000999R0505 (Version 01)
Measuring Module and Cables for 140G2-N, 140G2-NS
3
7
PH 2
8
10
9
2
1
11
12
4
3
Publication 140G-IN169B-EN-P - April 2021
DIR 1000999R0505 (Version 01)
Measuring Module and Cables for 140G2-N, 140G2-NS
4
13
140G2-N-VT3
14
140G2-N-VT3
TX 10
C
1.8 Nm
15.9 lb in
140G2-N-BT3
15
A2
Publication 140G-IN169B-EN-P - April 2021
DIR 1000999R0505 (Version 01)
Measuring Module and Cables for 140G2-N, 140G2-NS
5
140G2-N-VT3
16
TX 10
C
1.8 Nm
15.9 lb in
140G2-N-VT4
17
140G2-N-VT4
18
TX 10
C
1.8 Nm
15.9 lb in
V3
Publication 140G-IN169B-EN-P - April 2021
V2
V1
VN
DIR 1000999R0505 (Version 01)
Measuring Module and Cables for 140G2-N, 140G2-NS
6
140G2-N-BT4
19
B2
140G2-N-BT4
20
PH 1
C
V3
F
V2
V1
VN
4
4
21
B1
B2
Publication 140G-IN169B-EN-P - April 2021
DIR 1000999R0505 (Version 01)
Measuring Module and Cables for 140G2-N, 140G2-NS
7
22
A1
A2
24
23
3
4
25
26
PH 2
2
1
Publication 140G-IN169B-EN-P - April 2021
DIR 1000999R0505 (Version 01)
Measuring Module and Cables for 140G2-N, 140G2-NS
8
27
29
TX 8
Example 140G2-NS
28
30
TX 6
140G2-NS
PH 1
31
140G2-N
Publication 140G-IN169B-EN-P - April 2021
PH 1
PH 2
DIR 1000999R0505 (Version 01)
PH 1
PH 2
Measuring Module and Cables for 140G2-N, 140G2-NS
9
32
Installation Procedure
[1] Insert Trip Test Unit (140G-ELTT)
[2] Turn on Trip Test Unit; wait 10 seconds
[3] Warning LED flashing
[4] Press the "INSTALL" button on the display
Make sure there are no alarm icons present.
In case of alarms, consult user manual.
[1] Inserisci Trip Test Unit (140G-ELTT)
[2] Attiva Trip Test Unit; attendere 10 secondi
[3] LED di avviso lampeggiante
[4] Premere il pulsante "INSTALL" sul display
Assicurarsi che non siano presenti icone di allarme.
In caso di allarmi, consultare il manuale dell'utente
1
[1] Trip Test Unit einsetzen (140G-ELTT)
[2] Testeinheit einschalten; warte 10 Sekunden
[3] Warn-LED blinkt
[4] Drücken Sie die "INSTALL" -Taste auf dem Display
Stellen Sie sicher, dass keine Alarmsymbole vorhanden
sind. Im Falle von Alarmen konsultieren Sie die
Bedienungsanleitung.
2
TURN ON
3
4
[1] Inserir Trip Test Unit (140G-ELTT)
[2] Ligue a unidade de teste de disparo; aguarde
10 segundos
[3] LED de aviso piscando
[4] Pressione o botão "INSTALAR" no visor
Verifique se não há ícones de alarme presentes.
Em caso de alarme, consulte o manual do usuário.
[1] Insertar Trip Test Unit (140G-ELTT)
[2] Encienda la unidad de prueba de disparo; espera 10 segundos
[3] LED de advertencia parpadeando
[4] Presione el botón "INSTALAR" en la pantalla
Asegúrese de que no haya iconos de alarma presentes
En caso de alarmas, consultar el manual del usuario.
For Technical Support, visit rok.auto/support.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Product certificates are located in the Rockwell Automation Literature Library: rok.auto/certifications.
EEE Yönetmeliğine Uygundur.
TM
expanding human possibility
AMERICAS
EUROPE/MIDDLE EAST/AFRICA
ASIA PACIFIC
Publication 140G-IN169B-EN-P- April 2021
Copyright © 2021 Rockwell Automation, Inc. A
l l Rights Reserved. Printed in USA.
DIR 1000999R0505 (Version 01)
(ECN000161649) - ECN000161649
">