Installation Instructions
Original Instructions
22 mm Compact Metal Safety Limit Switches with 5-Pin Micro (M12) Plug
Connectors — 2 N.C.
Catalog Numbers 440P-AA1LB02D5, 440P-ADPB02D5, 440P-ARPB02D5, 440P-ASLB02D5
Summary of Changes
Specifications
This publication contains the following new or updated information. This list
includes substantive updates only and is not intended to reflect all changes.
Attribute
Value
Standards
IEC 60947-5-1, ISO 14119, EN IEC 60947-1
Topic
Certifications
cULus Listed, TÜV Certified, and CE Marked for all applicable EU
directives, UKCA Marked for all applicable regulations
rok.auto/certifications
Functional safety data
B10d: 2x106 operations
Intended application
Roller plunger (Figure 4 on page 3): Fulfills IEC 60947-5-1 requirements.
Type 1 interlocking devices according to ISO 14119.
Page
Updated Standards, Certifications, Intended application, Functional
safety data, and Enclosure type rating
1
Updated Table 1
2
Updated Declaration of Conformity
3
IMPORTANT
Save these instructions for future use. This publication
does not include all specifications, dimensions, or special
installation considerations.
ATTENTION: To avoid electrical shock and unintended operation
of equipment, disconnect all power to the safety limit switch and
the controlled equipment before you replace or adjust the safety
limit switch.
Improper selection or installation of the devices affects the
integrity of the safety systems and can result in personnel injury
or death, property damage, or economic loss.
Comply with ISO 14119 including selection, accessibility to the
installation, arrangement and fastening, possible substitute
actuation, access to the escape release, motivation to defeat, and
actuation mode.
Use management controls, working procedures, training and
additional procedures to minimize the motivation to defeat.
Comply with ISO 13857 and ISO 13855 for guard openings and
minimum (safe) distances.
Outputs
Safety contacts
2 N.C. snap action
Thermal current (/lth)
3A
Rated insulation voltage (ui)
250V AC
Short circuit protection
3 A max fast acting fuse IEC 269 type gG or equivalent
Operating Characteristics
Actuation speed, max
[mm/s (in/s)]
250 (9.84)
Actuation speed, min
[mm/min. (in/min.)]
100 (3.94)
Actuation frequency, max
[ops/hr]
6000
Mechanical life
1 x 107 operations at room temperature
Power source, max [AC/DC]
60V 3 A
Torque settings
[N•m (lb•in)]
• Operator head screws (see Figure 7 on page 3): 0.8 (7.1)
• Short and wide roller lever arm hex nut (see Figure 6 on page 3):
1.0 (8.85)
• Lever arm screw (see Figure 7 on page 3): 1.8...2.8 (15.93...24.78)
• Lever arm collar screw (see Figure 7 on page 3): 3.2 (28.32)
• Panel mount nut: 1.5 (13.28)
Environmental
Enclosure type rating
IMPORTANT
• Before installation in a safety application, perform a risk
assessment to determine whether the specifications of this
device are suitable for the foreseeable operational and
environmental characteristics of the machine that the
device controls.
• Follow all applicable standards for the application when you
deploy these safety limit switches.
• Follow operation specifications.
• Place the actuator beyond the point where direct opening
action occurs.
• Do not use these devices to control a motor directly.
NEMA 1, IP65/IP67
Operating temperature
[C° (F°)]
2...70 (35.6...158)
Pollution degree
3
General
Material
• Housing: Die cast alloy
• Actuator: Various polymers and metals
Mounting
2 x M4, any position
Vibration
IEC 60068-2-6, 10...55 Hz, 0.35 mm (1.38 in.) amplitude
Shock
IEC 60068-2-7, 30 Gn 3 pulses per axis
Connection
15 cm (6 in.) 5/22 AWG UL AWM 2464 pigtail with 5-pin M12 QD plug
Enclosure color
Red body/black head
Intended use
Cam actuated
Interlocking and coding type (1) Type 1, uncoded
(1)
ISO 14119 defines types of interlocking devices and coding.
WARNING:
• For safe operation, the M12 socket of the connecting cable
must be rated 60V 3 A or higher per standard EN 61984.
• The M12 socket connector of the connecting cable must have a
minimum sealing of IP65 to maintain a pollution degree 3
rating.
22 mm Compact Metal Safety Limit Switches with 5-Pin Micro (M12) Plug Connectors — 2 N.C. Installation Instructions
Figure 1 - Wiring Diagram
Installation
IMPORTANT
Installation of Allen-Bradley® Guardmaster® products must
be in accordance with local and/or national codes.
Servicing energized industrial control equipment can be
hazardous if not in accordance with recommended safety
procedures.
EN ISO 14119 replaces EN 1088 as the harmonized standard
for interlocking devices associated with guards.
See publication SAFETY-SR001.
Safety Input 1
Safety Output 1
Safety Input 2
Safety Output 2
ZA
Figure 2 - Contact Opening Characteristics
Plunger Type
Plunger Type
0 mm
1.4 mm
Lever Type
Lever Type
2.6 mm
60°
Open
Open
Wiring
2
1
3
4
Pin
Color
Type
Contact
1
Brown
Safety output 1
N.C.
2
Blue
Safety input 1
N.C.
3
Green/yellow
Common
Ground
4
Black
Safety input 2
N.C.
5
Black/white
Safety output 2
N.C.
6
-
Keyway
-
Recommended cable: Cat. No. 889D-F5AC-x
x = 2 (2 m [6.6 ft]), 5 (5 m [16.4 ft]) (recommended), or 10 (10 m [32.8 ft]) for standard cable
lengths. For other cable lengths, contact your local Allen-Bradley distributor or Rockwell
Automation sales office.
Approximate Dimensions
Ø13.0 (0.51)
Ø10.5
(0.14)
30.4
(1.2)
20.0
(0.79)
43.0
(1.69)
Ø7.2 (0.28)
20.0
(0.79)
25.0
(0.98)
Ø4.2 (0.17)
Electrical life depends on load, therefore, operations are
not applicable and withdrawn.
35.0
(1.38)
16.0
(0.63)
152.4 (6.00)
±5.0 (0.20)
Ø5.6 (0.22) ±0.1 (0.003)
45.0 (1.8)
±2.0 (0.08)
16.0 (0.6)
±1.0 (0.03) Ø14.5
(0.57)
2
85°
6
Figure 3 - Dome Plunger [mm (in.)]
These devices require little maintenance, but we recommend routine visual
inspection to help prevent the accumulation of foreign debris on the exterior
actuators and rollers. Do not remove the operator head.
26° 41°
Connector Pinout
60°
Maintenance
IMPORTANT
0°
Table 1 - 5-pin Micro (M12) Plug Connector
5
Some rotary switches include levers that mechanically couple to the actuating
shaft. You can remove and reinstalled the lever to adjust cam tracking. See Torque
settings on page 1.
26°
Positive
Opening
Point Point
Positive
Opening
Closed
Closed
30°
Lever Position
41°
11-12
21-22
Actuation Guidelines
30°
85°
5.5 mm
11-12
21-22
The method of actuation and over travel affects the service life of the safety limit
switch. To maximize the service life, we recommended that you provide an
actuator with a 30° pressure angle and a surface hardness of Rc-45 (max).
Gnd
Rockwell Automation Publication 440P-IN021B-EN-P - May 2023
M12 x 1
22 mm Compact Metal Safety Limit Switches with 5-Pin Micro (M12) Plug Connectors — 2 N.C. Installation Instructions
Figure 7 - Adjustable Roller Lever Arm [mm (in.)]
Ø16.5 (0.65) x 7
Figure 4 - Roller Plunger [mm (in.)]
30.4 (1.2)
3.8 (0.15)
Ø12 (0.47)
24
(0.94)
43
(1.69)
R27 (Min)
R105 (Max)
Ø7.2 (0.28)
20
(0.79)
25 (0.98)
43.4 (1.71)
38.2 (1.5)
3.5 mm
Operator
Head
Screw
4 mm Lever
Arm Screw
Ø4.2 (0.17)
Holes: 2 x Ø4.2 (0.17)
Countersink: Ø7.2 (0.28)
Depth: 4.2 (0.17)
18
(0.71)
35 (1.38)
16 (0.63)
3 mm Lever Arm
20 (0.79) Collar Screw
25 (0.98)
43
(1.69)
Figure 5 - Countersink Hole [mm (in.)]
25.0 (0.98)
20.0
(0.79)
Holes: 2 x Ø4.2 (0.17)
Countersink: Ø7.2 (0.28)
Depth: 4.2 (0.17)
35 (1.38)
16 (0.63)
Declaration of Conformity
CE Conformity
Lever Arm Switches
Lever arm versions are non-panel mount only.
IMPORTANT
Do not use operator heads with adjustable actuators for
safety applications.
Figure 6 - Short Roller Lever Arm [mm (in.)]
5.2
(0.2)
30.4 (1.2)
For a comprehensive CE certificate visit: rok.auto/certifications
UKCA Conformity
35.8 (1.41)
Rockwell Automation declares that the products that are shown in this document
are in compliance with 2016 No. 1091 Electromagnetic Compatibility Regulations
and 2008 No. 1597 Supply of Machinery (Safety) Regulations and that the respective
standards and/or technical specifications have been applied.
Ø13.5
(0.53)
25
(0.98)
Rockwell Automation declares that the products that are shown in this document
conform with the 2014/30/EU Electromagnetic Compatibility Directive (EMC) and
2006/42/EC Machinery Directive (MD) and that the respective standards and/or
technical specifications have been applied.
For a comprehensive UKCA certificate visit: rok.auto/certifications
18
(0.71)
43
(1.69)
Ø7.2
(0.28)
20
(0.79)
25
(0.98)
35 (1.38)
8Short
mmLever
Roller
Arm
8 mmArm
Hex Nut
Lever
Hex
Nut
Ø4.2
(0.17)
16 (0.63)
Rockwell Automation Publication 440P-IN021B-EN-P - May 2023
3
Rockwell Automation Support
Use these resources to access support information.
Technical Support Center
Find help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates.
Local Technical Support Phone Numbers
Locate the telephone number for your country.
rok.auto/support
rok.auto/phonesupport
Technical Documentation Center
Quickly access and download technical specifications, installation instructions, and user manuals.
rok.auto/techdocs
Literature Library
Find installation instructions, manuals, brochures, and technical data publications.
rok.auto/literature
Product Compatibility and Download Center (PCDC)
Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes.
rok.auto/pcdc
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
Waste Electrical and Electronic Equipment (WEEE)
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, Guardmaster, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 440P-IN021B-EN-P - May 2023 | Supersedes Publication 440P-IN021A-EN-P - May 2015
Copyright © 2023 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
*10000285540*
10000285540
PN-XXXXXX-XX
10000285540 Ver 02
">