Allen-Bradley ASEM 6300M DC Powered Panel Monitors Installation Instructions
Allen-Bradley ASEM 6300M DC Powered Panel Monitors offer a range of display sizes and resolutions, with IP65 environmental protection making them suitable for demanding applications like food processing and life sciences. They can be used in both non-hazardous and hazardous locations with long-distance capabilities for connecting to a computer up to 100 meters away.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Original Instructions ASEM 6300M DC Powered Panel Monitors Catalog Numbers 6300M-xxxBA and 6300M-xxxBB Topic Page Summary of Changes 1 Product Overview 1 UL/cUL Mark Compliance 1 Environment Information 2 Installation Requirements 2 Installation 4 Connection 5 Touch Screen Calibration 6 Additional Resources 6 Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Page Removed “VersaView” as product discription Updated DC power connector assembly instructions throughout 5 L ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Product Overview The ASEM™ 6300M DC powered panel monitor family is available in various display sizes and resolutions, and either standard or low profile bezel units. IP65 (model dependent) environmental protection makes your 6300M DC powered panel monitor an excellent match for wash-down applications such as food processing and life sciences. Some 6300M DC powered panel monitors have long-distance capabilities, which means they can be connected to a personal computer up to 100 m (328 ft) apart. Your panel can be used in either non-hazardous and hazardous locations. UL/cUL Mark Compliance Equipment with the UL/cUL mark complies with the requirements of UL 61010-1, UL 61010-2-201, CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201. A copy of the certificate of compliance is available at rok.auto/certifications. European Union Directive Compliance This equipment meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking. A copy of the declaration of the conformity is available at rok.auto/certifications. ATTENTION: This equipment is intended to operate in an industrial or control room environment, which uses some form of power isolation from the public low-voltage mains. Some computer configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union. All I/O cables must be used only indoors. ASEM DC Powered Panel Monitors Installation Instructions Environment Information ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/EN 61326-1. Without appropriate precautions, there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbance. This equipment is considered open equipment, which means it must be mounted in an enclosure where the equipment can be operated from the front panel. The enclosure in which this equipment is installed must be accessed only with a key or tool, and only by trained and authorized personnel. In addition to this publication, see the following: • Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements. • UL 50, CSA C22.2 No. 94.1, and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures. Your 6300M DC powered panel monitor can operate at a range of extremes. However, the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature, which includes the touch screen and LCD panel. • Installation Requirements DC Power Requirements IMPORTANT ASEM 6300M DC powered panel monitors for hazardous locations are intended only for USA and Canada applications. These monitors are suitable for use in Class I, Division 2 Groups A, B, C, D hazardous locations, or only in non-hazardous locations, with a temperature code of T5. WARNING: Explosion Hazard. • Substitution of any components can impair suitability for hazardous locations. • This equipment is an open-type device and is meant to be installed in an enclosure suitable for the environment such that the equipment is only accessible with the use of a tool. • Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations. • Peripheral equipment must be suitable for the location where it is used. • The front USB port is not for use in hazardous locations. Only use the front USB port for installation and maintenance. • In the U.S., all wiring must be in accordance with Class I, Division 2 wiring methods of Article 501 of the National Electrical Code, and in accordance with the authority having jurisdiction. • In Canada, all wiring must be in accordance with Section 18-1J2 of the Canadian Electrical Code, and in accordance with the authority having jurisdiction. Your 6300M DC powered panel monitor with DC power input must: • be connected to a 24V (18-32V) power supply that satisfies the requirements of safe extra low voltage (SELV) in accordance with IEC/EN/ DIN EN/UL60950-1 and as defined in IEC-61010-2-201, power supply per UL. • use an isolated power supply with galvanic isolation to help prevent common mode noise at low/medium frequencies on the power supply line, ground loop noise, and extra-voltage caused by lightning. • To minimize ground loop currents and noise, Allen-Bradley® recommends that your DC powered model uses only one grounded connection. Power Consumption The following table shows the power consumption in watts of your 6300M DC powered panel monitor. See the product label on the back side of your 6300M DC powered panel monitor to determine its catalog number. Table 1 - Maximum Power Consumption (Watts) Access is gained only by service personnel or by users who have been instructed on the reasons for restrictions to a location and about any precautions to be taken. Access is by using a tool, a lock and key, or other means of security controlled by the authority responsible for the location. 2 Your installation site: - must have sufficient power, - must be indoors and non-hazardous except where the monitor is rated for hazardous locations (see Hazardous Locations), and 4:3 18.1 22.7 16:10 13.2 18.4 1024 x 768, XGA 4:3 15.3 20.5 15.6 1920 x 1080, FHD 16:9 25.9 30.3 17 1280 x 1024, SXGA 5:4 22.8 27.7 18.5 1920 x 1080, FHD 16:9 28.2 33.3 19.0 1280 x 1024, SXGA 5:4 22.3 27.3 1920 x 1080, FHD 16:9 27.4 32.4 21.0 26.2 21.5 24 (1) 6300M-xxxD 1024 x 768, XGA 15 Follow these environment requirements to make sure that your 6300M DC powered panel monitor provides service with excellent reliability. 6300M-xxxB 1280 x 800, WXGA 12.1 Environment Requirements • Power Consumption (Watts), Max (1) Display Size Resolution (W x H) Aspect Ratio For hazardous locations, verify that restricted access locations meet these conditions for your 6300M DC powered panel monitor: • In environments with electrical noise, use an isolated power source and electromagnetic compatibility (EMC) filter to help provide a reliable touch screen operation. Use an analog resistive touch screen where you anticipate EMC noise. Display Information Restricted Access Locations • Your 6300M DC powered panel monitor can be stored in a surrounding air temperature range of -5…+60 °C (23…140 °F). The relative humidity of the ambient air must be 20…90% noncondensing at 0…40 °C (32…104 °F), and 20…80% noncondensing at 41…50 °C (105…122 °F). • Hazardous Locations IMPORTANT - must not expose your panel PC to direct sunlight. The ambient air temperature range is 0…50 °C (32…122 °F), and have a temperature code of T5. - The surrounding air temperature must not exceed this maximum temperature, especially when mounted in an enclosure. • Add 2.5 W of power consumption for any USB port that is used. Rockwell Automation Publication 6300M-IN002C-EN-P - March 2023 ASEM DC Powered Panel Monitors Installation Instructions DC Power Supply Requirements Figure 1 - Minimum Clearance [cm (in.)] Horizontal Orientation, Rear View 10 (3.94) Follow these requirements to select the power supply for your 6300M DC powered panel monitor with DC power input. • • • • • The monitor must be powered with a voltage of 24V DC (18…32V DC SELV input voltage range). The nominal output power must be 25% larger than the rated power of this DC powered panel monitor. The output voltage rise time has to be less than 100 ms. Consider the working temperature and the thermal derating of the power supply. Able to supply the inrush current of this monitor which will not exceed peak current of 10A and a pulse width time of 400 µs. 7 (2.75) 7 (2.75) I/O Ports Face Downward Peripheral Connection Requirements IMPORTANT To comply with EN 61326-1, all cable types must be shielded and must be used only indoors, and USB cables must be less than 3 m (9.84 ft) in length. IMPORTANT Before connecting or disconnecting peripheral cables from I/O ports, verify that you are in a non-hazardous location before you connect or disconnect any peripheral connections. The front USB port on your 6300M-xxxBA and 6300M-xxxBB DC powered panel monitor is not for use in hazardous locations. Only use the front USB port for installation and maintenance purposes. Follow these requirements to for the panel cutout. • • 7 (2.75) 10 (3.94) Panel Cutout Requirements • • Vertical Upright Position, Side View The mounting surface material must be 2…6 mm (0.08…0.24 in.) thick. For a uniform gasket seal, the roughness of the panel surface must not exceed 120 microns (Rz 120). Verify that the area around the panel is clear of obstructions. The panel cutout area depends upon the display size and format of your 6300M DC powered panel monitor. See Table 2. Table 2 - Panel Cutout Area [mm (in.)] Table 3 - I/O Ports and Slot Locations B B A Standard Standard DC Powered Panel Monitor A Widescreen Front Bezel View 6 Bottom View (1) Dimension A (2) Dimension B (2) 315 (12.4) 250 (9.84) 203 (7.99) Display Size Format 12.1 Standard 12.1 Widescreen 301 (11.8) 15 Standard 370 (14.57) 295 (11.61) 15.6 Widescreen 388 (15.28) 238 (9.37) (1) 17 Standard 435 (17.13) 335 (13.19) 18.5 Widescreen 453 (17.83) 274 (10.79) 19 Standard 470 (18.5) 368 (14.49) 21.5 Widescreen 520 (20.47) 312 (12.28) 24 Widescreen 577 (22.71) 344 (13.54) 5 1 Front Bezel View 6 Bottom View 5 Follow these requirements to mount your 6300M DC powered panel monitor. Choose a suitable mounting height. For optimal performance: To help prevent overheating and to provide access to the I/O ports for cable connections, provide minimum clearances specified in Figure 1 around the perimeter of the outer frame and the back of the chassis. IMPORTANT Required for hazardous locations: You must mount your panel PC horizontally in a 0° vertical (upright) position with the I/O ports facing downward. 3 8 Mounting Requirements • • 4 Long Distance DC Powered Panel Monitor Standard format is offered with an analog resistive touch screen. Widescreen format is offered with analog resistive and projective capacitive (PCAP) touch screens. All dimensions are ± 1 mm (0.04 in.). (2) 3 2 8 (1) (2) (3) 7 4 Item No. Cable Type Required Attribute 1 DisplayPort 2 DVI-D 3 USB Hub 4 USB 2.0 (3 quantity) 5 USB 2.0 (1) 6 USB 2.0 (2) 7 RVL (3) 8 DC Power Shielded Shielded Unshielded Optional feature. Only certain models offer a USB 2.0 port on the front bezel. IMPORTANT: USB ports on front bezels are not for use in hazardous locations. RVL (remote video link) requires specific Ethernet cables. Contact Rockwell Automation for ordering information. Rockwell Automation Publication 6300M-IN002C-EN-P - March 2023 3 ASEM DC Powered Panel Monitors Installation Instructions Required Tools and Hardware 4. Hand-tighten the mounting clips according to the tighten sequence shown. 12.1, 15, and 17 in. Display Sizes 1 8 You need the following tools to install and connect your panel PC. • • • • • • • • DC power supply (see DC Power Supply Requirements) Cutout tools appropriate for mounting material Safety glasses Torque limiting screwdriver with 1.5 mm hex key Wire stripper, cutter, and crimper tool Small screwdriver Adjustable torque screwdriver with M2 and M3 flat blade bits Peripheral cables (see Peripheral Connection Requirements) 15.6 and 19-in. Display Sizes 1 5 10 12 3 5 7 3 I/O Ports I/O Ports 6 4 8 4 2 7 11 18.5 in. Display Size 1 10 5 10 6 2 9 21.5 and 24-in. Display Sizes 12 5 1 13 Installation 8 Prepare the Panel Cutout 3 I/O Ports 1. 2. 3. Disconnect all electrical power before you make the cutout. Cut an opening in the mounting material according to the dimensions specified for your model shown in Panel Cutout Requirements on page 3. Clean the panel area of all debris and metal fragments. 2. 2 8 14 IMPORTANT 6. 7. From the front of the panel, insert your 6300M DC powered panel monitor into the cutout as shown. 6 2 9 Use a torque limiting screwdriver and 1.5 mm hex key bit, tighten the mounting clips to a torque of 0.2 N•m (1.8 lb•in) in the tighten sequence performed in step 4. Make sure that the sealing gasket is positioned properly on your 6300M DC powered panel monitor. All monitors have a gasket that forms a compression-type seal. Do not use sealing compounds. 9 4 I/O Ports 11 5. To ease installation, two people should install your 6300M DC powered panel monitor; one person to hold it in place and the other to install the mounting clips. IMPORTANT 3 7 6 Install the Monitor into the Panel Cutout 1. 7 4 The mounting clips must be tightened to a torque of 0.2 N•m (1.8 lb•in). Doing so provides a proper seal and to help prevent product damage. Allen Bradley assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation. Repeat step 5 at least three times until all mounting clips are torqued to 0.2 N•m (1.8 lb•in). Verify that the gasket is compressed uniformly against the panel. If the gasket is not compressed uniformly: loosen the mounting clips by tightening sequence, then repeat steps 5…7. Grounding and Bonding Whenever two connected pieces of equipment are far apart, it is possible that their ground connections could be at a different potential level. To overcome possible grounding problems, the following bonding methods are recommended: • Bonding Method 1: Connect the data cable shields to the Equipotential bonding rail on both sides before connecting the cable to the interfaces. 3. Slide the mounting clips into the holes on all four sides of 6300M DC powered panel monitor as shown. • B A C 4 Bonding Method 2: Use an Equipotential bonding cable (16 mm2 or AWG 6) to connect the grounds between your 6300M DC powered panel monitor and PC. Install the Ground Wire 1. 2. Turn off the main power switch or breaker. Remove the ground screw, eyelet terminal, and washers from the bottom of your 6300M DC powered panel monitor. 3. For earth ground, install a grounding wire to the eyelet terminal. a. Use a 2.5 mm2 (14 AWG) or larger external wire to the eyelet terminal. Use a grounding wire with an insulation color that is approved by local inspection authority. b. Strip 5 mm (0.20 in.) from the covering at the end of the grounding wire. c. Insert the stripped end of the grounding wire into the open end of the eyelet terminal, and crimp it securely to the wire. D Rockwell Automation Publication 6300M-IN002C-EN-P - March 2023 ASEM DC Powered Panel Monitors Installation Instructions 4. Reinstall the eyelet terminal and washers to the ground screw in the sequence shown. 1 5. 2 3 4 5 9. Sequence No. Description 1 Toothed washer 2 Eyelet terminal 3 Washer 4 Lock washer 5 Ground Screw Tighten the ground screw to the monitor chassis. Install the white label supplied with the kit (E of Figure 2). The white label can be used for identification or other information. 10. Align and install the other connector clamp half to complete the assembly (F of Figure 2). When it is installed correctly, both tabs of the clamp half lock into place (G of Figure 2). 11. Connect the DC terminal block with the connector assembly to the chassis of your 6300M DC powered panel monitor. 12. Torque the DC terminal block flange screws to the values in Table 4. Connection Install the DC Power Connector Assembly The DC power connector assembly that is shipped with your 6300M DC powered panel monitor must be assembled. This connector assembly provides strain relief for the DC power wires by reducing their movement. To assemble, wire, and install the DC power connector on the monitor, perform the following steps. IMPORTANT Verify that you are in a non-hazardous location before you connect or disconnect any power connections. WARNING: Explosion Hazard. For 6300M DC powered monitors that are used in hazardous locations: Do not connect or disconnect when energized. IMPORTANT Before connecting or disconnecting peripheral cables from I/O ports, verify that you are in a non-hazardous location before you connect or disconnect any peripheral connections. The front USB port on your DC powered panel monitor is not for use in hazardous locations. Only use the front USB port for installation and maintenance purposes. Figure 2 - DC Power Connector Assembly B A C D 1. G F E 2. H 3. 4. Table 4 - DC Terminal Block Specifications Be sure you are complying with all actions listed in Mounting Requirements on page 3. Connect peripheral cables to the appropriate I/O ports of your 6300MDC powered panel monitor. See Table 3 on page 3 for I/O port locations. See the installation guides and user manuals for your other components to properly connect the free end of the peripheral cables. Connect the DC power to your 6300M DC powered panel monitor. The LED status indicator(s) illuminate. 5 See LED Status Indicators and Buttons for status. 4 3 1 5. 2 4 3 If necessary, use the display buttons located underside of your 6300M DC powered panel monitor to enter, navigate, and adjust various display setting menus. 5 Note No. Description Value 1 DC+ (24V DC nominal) recommended power wire size 2 DC- (0V DC) recommended power wire size 2.5 mm2 (14 AWG) 3 Stripped wire length 7 mm (0.275 in.) 4 Torque range to secure DC power wires 0.5...0.6 N•m (0.37...0.4 lb•ft) 5 Torque value to reinstall DC terminal block to product 0.3 N•m (0.22 lb•ft) 1. 2. 3. 6. 7. 8. LED Status Indicators and Buttons When the DC power is connected to your 6300M DC powered panel monitor, various LED status indicators will illuminate. For all 6300M models, the LED status indicator on the front bezel will illuminate. Table 5 - LED Status Indicator: All 6300M Models Lay out the DC power connector assembly kit (A of Figure 2). Insert the cable tie through the slots of the appropriate connector half (B of Figure 2).. Verify the stripped ends of each DC power wire is 7 mm (0.275 in.). If necessary, adjust the stripped length. IMPORTANT 4. 5. See LED Status Indicators and Buttons for button functions. DC power wires must be of stranded copper and certified for at least 85 °C (185 °F) operation. Insert each stripped end into the DC terminal block as shown in Table 4. Tighten the screws on top of the terminal block to secure the DC power wires to the torque value in Table 4. Slide the connector half with the attached tie onto the end of the DC terminal block (C of Figure 2). Tighten the cable tie so it is snug against the terminal wires. Use cutting pliers to cut the excess part of the cable tie (D of Figure 2). 1 Front Bezel, Bottom Left Note No. Description 1 Color Function Green Correct video signal input Amber Unsupported video signal Flashing Yellow No video signal Status Rockwell Automation Publication 6300M-IN002C-EN-P - March 2023 5 For 6300M DC powered panel monitors with RVL, LED status indicators will illuminate on the underside of your 6300M DC powered panel monitor. Touch Screen Calibration Table 6 - LED Status Indicators: With RVL Connection ASEM 6300M DC powered panel monitor with analog resistive touch screens uses an eGalax Touch (touch panel) driver and can be field calibrated. ASEM 6300M DC powered DC panel monitors with PCAP touch screens use the native Microsoft Windows® Human Interface Device (HID) driver and cannot be field calibrated. For more information on field calibration, see 6300M Panel Monitor User Manual, publication. Underside, Middle 1 2 3 4 Additional Resources Note No. Description Color Function 1 Link Green The monitor is linked to a remote, RVL capable PC. 3 Video Flashing Yellow The monitor is receiving streaming video from the remote PC. 4 Run Flashing Green The remote computer is operating correctly. 5 Power Green The monitor RVL port is operating correctly. Provides instruction to operate and ASEM 6300M DC Powered Panel Monitor User troubleshoot ASEM 6300M DC powered panel Manual, publication 6300M-UM001 monitors. Use the on-screen display buttons located underside of your 6300M DC powered panel monitor to enter, navigate, and adjust various display setting menus. ASEM 6300 Industrial Computer and Monitor Provides technical specifications about all 6300 industrial PCs, thin clients, and Specifications Technical Data, monitors. publication IC-TD003 Table 7 - Display Buttons Industrial Automation Wiring and Grounding Provides general guidelines for installing a Rockwell Automation industrial system. Guidelines, publication 1770-4.1 This publication provides basic installation instructions. For more information, see the following Rockwell Automation publications at https://rok.auto/literature. Resource Product Certifications website, rok.auto/certifications. Note No. Description Provides declarations of conformity, certificates, and other certification details. 3 1 Underside, Far Right Description 2 4 Function 1 + (<—) Increase the value of the selected control or selects the next menu item. 2 – (—>) Decreases the value of the selected menu item or selects the previous menu item. 3 Menu/Select Push to enter the main menu. Push to select a highlighted menu option, which can prompt a submenu. Push to exit from current menu (back option). 4 ESC (Exit) Exits the menu. Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. For technical support, visit rok.auto/support. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, ASEM, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 6300M-IN002C-EN-P - March 2023 | Supersedes Publication 6300M-IN002B-EN-P - October 2021 Copyright © 2023 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. *PN-647949* PN-647949 Vendor Code 80460082.02 DIR 10006408102_02 ">
Advertisement
Key features
- IP65 Protection
- Various display sizes
- Non-hazardous & hazardous locations
- Long-distance capabilities
- DC power input
- Touch screen calibration
- UL/cUL certified
- CE marked
- RVL (remote video link)
Frequently asked questions
The monitor can operate in a temperature range of -5°C to 60°C and a relative humidity of 20% to 90% non-condensing. It is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications, at altitudes up to 2000 meters. The monitor should be installed indoors unless rated for hazardous locations.
The monitor requires a 24V DC power supply (18-32V DC SELV input voltage range). The nominal output power of the power supply should be 25% larger than the rated power of the monitor. Allen-Bradley recommends using a single grounded connection for the DC powered model to minimize noise.
The monitor should be mounted horizontally in a 0° vertical position with the I/O ports facing downward. The mounting surface material must be 2-6 mm thick, and the roughness of the panel surface must not exceed 120 microns.
Yes, certain models are rated for use in Class I, Division 2 Groups A, B, C, D hazardous locations with a temperature code of T5. However, the front USB port is not for use in hazardous locations. Only use the front USB port for installation and maintenance purposes.
ASEM 6300M models with analog resistive touch screens use an eGalax Touch driver and can be field calibrated. Models with PCAP touch screens use the native Microsoft Windows HID driver and cannot be field calibrated. Refer to the 6300M Panel Monitor User Manual for more information on field calibration.