Installation Instructions
Original Instructions
58UHF RFID Short-range Transceiver
Catalog Numbers 58UHF-TR-100-SR15US, 58UHF-TR-100-SR15EU
Status Indicator Functionality
WARNING: Never disassemble or modify the scanner. Doing so
could result in an accident such as fire or electric shock.
Features
•
Global Ultra-High Frequency (UHF) RFID solution
- 865...868 MHz EU and UK model (CE)
- 902...928 MHz US and North America model (FCC)
Tag compatibility: ISO 18000-63 (EPC global Gen2) compliant
Sensing range up to 1.5 m (4.92 ft)
Built-in status indicators for diagnostics
All-in-one linear and circular antennas
Excellent reliability in harsh environments
•
•
•
•
•
Name
Typical Applications
•
•
•
•
•
Asset tracking
Data acquisition
Product handling
Automotive
Food and pharmaceutical
MOD
State
Indicates
Off
No power
Steady green
Indicates
Flashing green
status of the
transceivers Flashing red
Steady red
Device operational
Standby (device has not been configured)
Major recoverable fault
Major nonrecoverable fault
Flashing green/red Self-test (power-up testing)
Specifications
Attribute
Description
Value
Enclosure rating
IP66/67
Operating temperature [°C (°F)]
-20…+55 (-4…+131)
Storage temperature [°C (°F)]
-40…+85 (-40…+185)
Relative humidity (1)
• Operating: 35...95%
• Storage: 25...85%
Vibration
10 g at 10...500 Hz
Shock resistance [g]
50
Off
No link
Steady green
Link
Indicates
Steady yellow
status of
Link1/2
Ethernet (E1/ Flashing green
E2) port
Flashing yellow
Port disabled
Port activity (data packets currently being
exchanged)
Collision
Steady red
Major NIC fault
Off
No power or powered on with no IP address
Flashing green
Indicates
status of the
connections Steady green
No connections (IP address, but no CIP™
connections are
established, and an exclusive owner
connection has timed
out)
Tag compatibility
ISO 18000-63
Sensing distance, max (2) [m (ft.)]
1.5 (4.92)
Compliance
FCC, UL/cUL, CE, UKCA, and ISED
Flashing red
Connection timeout
Connector
• EtherNet/IP™: M12 4-pin plug DC Micro
• Power and I/O: M12 4-pin socket DC Micro
Steady red
Duplicate IP
Communication protocol
EtherNet/IP
Supply voltage
19.2…26.4V DC
Current consumption at 24V DC, max
• Supply: 1 A CLASS2/SELVS
• Input: 15 mA
• Output: 0.5 A
Communication rate
• RFID: 1024 bps
• Ethernet: 10/100 Mbps, half or full-duplex
Frequency
• 865.7…867.5 MHz EU and UK model (at 600 kHz intervals, 4
channels total)
• 902.75…927.25 MHz US and North America model (at 500
kHz intervals, 50 channels total)
(1)
(2)
No condensation
The setting limits depend on the country or the function. This reference value can vary depending on
the operating environment tag type.
NET
Connected
Flashing green/red Self-test (power-up testing)
Off
Steady green
R/W
Flashing green
Indicates
status of the
read/write
Steady yellow
commands
No power
Powered but idle
Transmitting RF carrier wave (no tags
detected)
Succeeded at tag operation (tag read/write
complete)
Flashing yellow
Failed at tag operation (tag read/write
incomplete)
Flashing red
RF transmit failure
58UHF RFID Short-range Transceiver Installation Instructions
FCC Notice (For U.S. Customers)
IMPORTANT
Installation must be in accordance with local and/or
national codes. Servicing energized industrial control
equipment can be hazardous if not in accordance to
recommended safety procedures.
Connector Pinouts
Changes and modifications that are not expressly approved by Rockwell
Automation can void your authority to operate this equipment under Federal
Communications Commissions rules.
Table 1 - EtherNet/IP (1)
DC M12, D-coded, 4-pin Plug
Pin
Signal
Color
1
1
TxData +
White/orange
4
2
3
(1)
This transmitter must not be co-located or operated in conjunction with any other
antenna or transmitter. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: (1) This device will not cause
harmful interference; and (2) This device must accept any interference received,
including interference that can cause undesired operation of the device.
2
Recv Data +
White/green
3
TxData -
Orange
4
Recv Data -
Green
This equipment is tested and found to comply with the limits for a Class A digital
device, according to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
ATTENTION: This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, can cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference, in which case you must correct the interference
at your own expense.
E1 - Standard right-angle Ethernet cables point left.
E2 - Standard right-angle Ethernet cables point right.
Table 2 - Power I/O
DC M12, D-coded, 4-pin Socket
Pin
Signal
Color
1
1
+24V DC
Brown
2
Input
White
3
0V DC
Blue
4
Output
Black
4
2
3
2
IMPORTANT
This equipment complies with FCC radiation exposure
limits for an uncontrolled environment and meets the FCC
radio frequency (RF) Exposure Guidelines. When you install
and operate this equipment, keep a minimum of 35 cm
(13.78 in.) between the radiator and a person’s body.
Rockwell Automation Publication 58UHF-IN001A-EN-P - December 2022
58UHF RFID Short-range Transceiver Installation Instructions
ISED Information
Declaration of Conformity
This device complies with the Industry Canada license-exempt RSS Industry
Canada license-exempt RSS standards. Operation is subject to the following two
conditions: (1) This device may not cause interference; and (2) This device must
accept any interference, including interference that may cause undesired
operation of the device.
CE Conformity
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IMPORTANT
This equipment complies with ISED radiation exposure
limits for an uncontrolled environment and meets RSS 102
of the ISED radio frequency (RF) Exposure rules. When you
install and operate this equipment, keep a minimum of
35 cm (13.78 in.) between the radiator and a person’s body.
Cet équipement est conforme aux limites d’exposition aux
rayonnements énoncées pour un environnement
non-contrôlé et respecte les règles d’exposition aux
fréquences radioélectriques (RF) CNR 102 de l’ISDE. Cet
équipement doit être installé et utilisé en gardant une
distance de 35 cm (13.78 in.) ou plus entre le radiateur et le
corps humain.
Rockwell Automation, Inc. declares that the radio equipment type
58UHF-TR-100-LR15EU is in compliance with the 2014/53/EU Radio Equipment
Directive and the 2011/65/EU RoHS Directive.
For a comprehensive CE certificate visit: rok.auto/certifications.
UKCA Conformity
Rockwell Automation, Inc. declares that the radio equipment type
58UHF-TR-100-LR15EU is in compliance with the Radio Equipment Regulations
(2017 No. 1206) and the Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulations (2012 No. 3032).
For a comprehensive UKCA certificate visit: rok.auto/certifications.
Türkiye Cumhuriyeti: AEEE Yönetmeliðine Uygundur
Application
Frequency Range
Power
UHF RFID
865…868 MHz
2 W e.r.p.
Rockwell Automation Publication 58UHF-IN001A-EN-P - December 2022
3
Rockwell Automation Support
Use these resources to access support information.
Technical Support Center
Find help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates.
Local Technical Support Phone Numbers
Locate the telephone number for your country.
rok.auto/support
rok.auto/phonesupport
Technical Documentation Center
Quickly access and download technical specifications, installation instructions, and user manuals.
rok.auto/techdocs
Literature Library
Find installation instructions, manuals, brochures, and technical data publications.
rok.auto/literature
Product Compatibility and Download Center (PCDC)
Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes.
rok.auto/pcdc
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
Waste Electrical and Electronic Equipment (WEEE)
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
CIP and EtherNet/IP are trademarks of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 58UHF-IN001A-EN-P - December 2022 | Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the Japan
10007125910 Ver 00
">