Installation Instructions
Original Instructions
58UHF RFID Long-range Transceiver
Catalog Numbers 58UHF-TR-200-LR50US, 58UHF-TR-200-LR50EU
Status Indicator Functionality
WARNING: Never disassemble or modify the scanner. Doing so
could result in an accident such as fire or electric shock.
Features
•
Global Ultra-High Frequency (UHF) RFID solution
- 865...868 MHz EU and UK model (CE)
- 902...928 MHz US and North America model (FCC)
Tag compatibility: ISO 18000-63 (EPC global Gen2) compliant
Inventory speed up to 500 tags/sec (FCC)
Sensing range up to 5 m (16.4 ft)
Built-in status indicators for diagnostics
All-in-one linear and circular antennas
Excellent reliability in harsh environments
DLR support
•
•
•
•
•
•
•
Name
Typical Applications
•
•
•
•
•
•
•
•
•
•
Asset tracking
Data acquisition
Product handling
Automotive
Food and pharmaceutical
As part of track and trace solution
Traceability control
Gate control
Location control (warehouse)
Pallet and returnable package management (for sustainability)
MOD
Link1/2
Description
Indicates status of
Ethernet (E1/E2) port
Value
Enclosure rating
IP66/67
Operating temperature [°C (°F)]
-20…+55 (-4…+131)
Indicates
Off
No power
Steady green
Device operational
Indicates status of the Flashing green
transceivers
Flashing red
Specifications
Attribute
State
Standby (device has not been
configured)
Major recoverable fault
Steady red
Major nonrecoverable fault
Flashing green/red
Self-test (power-up testing)
Off
No link
Steady green
Link
Steady yellow
Port disabled
Flashing green
Port activity (data packets
currently being exchanged)
Flashing yellow
Collision
Steady red
Major NIC fault
Off
No power or powered on with
no IP address
Flashing green
No connections (IP address, but
no CIP™ connections are
established, and an exclusive
owner connection has timed
out)
Connected
Storage temperature [°C (°F)]
-40…+85 (-40…+185)
Relative humidity
• Operating: 35...95%
• Storage: 25...85%
Vibration
10 g at 10...500 Hz
Steady green
Shock resistance [g]
50
Flashing red
Connection timeout
Tag compatibility
ISO 18000-63
Steady red
Duplicate IP
Sensing distance, max (1) [m (ft.)]
5 (16.4)
Flashing green/red
Self-test (power-up testing)
Compliance
FCC, UL/cUL, CE, UKCA, and ISED
Off
No power
Connector
• EtherNet/IP™: M12 4-pin plug DC Micro
• Power and I/O: M12 4-pin socket DC Micro
Steady green
Powered but idle
Communication protocol
EtherNet/IP
Flashing green
Supply voltage
19.2…26.4V DC
Transmitting RF carrier wave
(no tags detected)
Current consumption at 24V DC,
max
• Supply: 1 A CLASS2/SELVS
• Input: 15 mA
• Output: 0.5 A
Communication rate
• RFID: 2048 bps
• Ethernet: 10/100 Mbps, half or full-duplex
Frequency
• 865.7…867.5 MHz EU and UK model (at 600 kHz intervals, 4
channels total)
• 902.75…927.25 MHz US and North America model (at 500 kHz
intervals, 50 channels total)
(1)
The setting limits depend on the country or the function. This reference value can vary depending on
the operating environment tag type.
NET
R/W
Indicates status of the
connections
Indicates status of the
read/write commands Steady yellow
Succeeded at tag operation (tag
read/write complete)
Flashing yellow
Failed at tag operation (tag
read/write incomplete)
Flashing red
RF transmit failure
58UHF RFID Long-range Transceiver Installation Instructions
FCC Notice (For U.S. Customers)
IMPORTANT
Installation must be in accordance with local and/or
national codes. Servicing energized industrial control
equipment can be hazardous if not in accordance to
recommended safety procedures.
Connector Pinouts
Changes and modifications not expressly approved by Rockwell Automation can
void your authority to operate this equipment under Federal Communications
Commissions rules.
Table 1 - EtherNet/IP (1)
DC M12, D-coded, 4-pin Plug
1
4
2
3
(1)
This transmitter must not be co-located or operated in conjunction with any other
antenna or transmitter. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: (1) This device will not cause
harmful interference; and (2) this device must accept any interference received,
including interference that may cause undesired operation of the device.
Pin
Signal
Color
White/orange
1
TxData +
2
Recv Data +
White/green
3
TxData -
Orange
4
Recv Data -
Green
This equipment is tested and found to comply with the limits for a Class A digital
device, according to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
ATTENTION: This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, can cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference, in which case you must correct the interference
at your own expense.
E1 - Standard right-angle Ethernet cables point left.
E2 - Standard right-angle Ethernet cables point right.
Table 2 - Power I/O
DC M12, D-coded, 4-pin Socket
Pin
Signal
Color
1
1
+24V DC
Brown
4
2
3
2
2
Input
White
3
0V DC
Blue
4
Output
Black
IMPORTANT
This equipment complies with FCC radiation exposure
limits for an uncontrolled environment and meets the FCC
radio frequency (RF) Exposure Guidelines. When you install
and operate this equipment, keep a minimum of 90 cm
(35.4 in.) between the radiator and a person’s body.
Rockwell Automation Publication 58UHF-IN002A-EN-P - December 2022
58UHF RFID Long-range Transceiver Installation Instructions
ISED Information
Declaration of Conformity
This device complies with Innovation, Science and Economic Development Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference; and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
CE Conformity
Le présent appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
IMPORTANT
This equipment complies with ISED radiation exposure
limits for an uncontrolled environment and meets RSS-102
of the ISED radio frequency (RF) Exposure rules. Install and
operate this equipment keeping a minimum of 90 cm
(35.4 in.) between the radiator and a person’s body.
Cet équipement est conforme aux limites d’exposition aux
rayonnements énoncées pour un environnement
non-contrôlé et respecte les règles d’exposition aux
fréquences radioélectriques (RF) CNR-102 de l’ISDE. Cet
équipement doit être installé et utilisé en gardant une
distance de 90 cm (35.4 in.) ou plus entre le radiateur et le
corps humain.
Rockwell Automation, Inc. declares that the radio equipment type
58UHF-TR-200-LR15EU is in compliance with the 2014/53/EU Radio Equipment
Directive and the 2011/65/EU RoHS Directive.
For a comprehensive CE certificate visit: rok.auto/certifications.
UKCA Conformity
Rockwell Automation, Inc. declares that the radio equipment type
58UHF-TR-200-LR15EU is in compliance with the Radio Equipment Regulations
(2017 No. 1206) and Restriction of the Use of Certain Hazardous Substances in
Electrical and the Electronic Equipment Regulations (2012 No. 3032).
For a comprehensive UKCA certificate visit: rok.auto/certifications.
Türkiye Cumhuriyeti: AEEE Yönetmeliðine Uygundur
Application
Frequency Range
Power
UHF RFID
865…868 MHz
2 W e.r.p.
Rockwell Automation Publication 58UHF-IN002A-EN-P - December 2022
3
Rockwell Automation Support
Use these resources to access support information.
Technical Support Center
Find help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates.
Local Technical Support Phone Numbers
Locate the telephone number for your country.
rok.auto/support
rok.auto/phonesupport
Technical Documentation Center
Quickly access and download technical specifications, installation instructions, and user manuals.
rok.auto/techdocs
Literature Library
Find installation instructions, manuals, brochures, and technical data publications.
rok.auto/literature
Product Compatibility and Download Center (PCDC)
Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes.
rok.auto/pcdc
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
Waste Electrical and Electronic Equipment (WEEE)
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
CIP and EtherNet/IP are trademarks of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 58UHF-IN002A-EN-P - December 2022 | Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the Japan
10007114406 Ver 00
">