Allen-Bradley 800G Latch Mount Back-of-Panel Modules Installation Instructions
Allen-Bradley 800G Latch Mount Back-of-Panel Modules are designed for use in hazardous areas where machine functions are activated by pressing a button or actuating a switch. They feature self-cleaning contacts and N.O. contacts with positive break operation. These modules are compatible with all 800G non-illuminated operators and the panel mount cover accessory. They are also available as power modules and power modules with contact blocks, which can be used to visually indicate the functional status of machines by lighting up or turning off.
PDF
Document
Advertisement
Advertisement
Bul. 800G Publication 800G-IN003C-EN-P - May 2022 en Installation instructions Latch Mount Back-of-Panel Modules de Montageanweisung fr Notice de montage it Istruzioni di montaggio zh es Instrucciones de montaje ru Инструкция по монтажу pt Instruções de instalação ko 설치 매뉴얼 At the end of its life, this equipment should be collected separately from any unsorted municipal waste. ATTENTION: To help prevent electrical shock, disconnect from Product Description • Contact block (catalog number 800G-XLSx-EX) power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from Contact blocks are used within hazardous areas where machine functions are activated by pressing a button or actuating a switch. These contact blocks are designed with self-cleaning contacts and N.O. contacts feature positive break operation. Contact blocks are compatible with all 800G non-illuminated operators and the panel mount cover accessory (catalog number 800G-APMC). contaminants. Only suitably trained personnel can install, adjust, commission, use, assemble, disassemble, and maintain the product in accordance with applicable code of practice. If a malfunction or damage occurs, do not attempt to repair the product. IMPORTANT • Power module (catalog number 800G-DLSx-EX) When working in hazardous areas, the safety of personnel Power modules are used within hazardous areas to indicate the functional status of respective machines visually by lighting up or turning off. Power modules are compatible with all 800G pilot light operators and the panel mount cover accessory (catalog number 800G-APMC). and equipment depends on compliance with the relevant safety regulations. The people in charge of installation and maintenance bear a special responsibility. They must be knowledgeable of the applicable rules and regulations. These instructions provide a summary of the most important • Power module with contact block (catalog number 800G-DLSxXx-EX). installation measures. Everyone working with the product must read these instructions so that they are familiar with the Power module with contact block combination units are used within hazardous areas where machine functions are activated by depressing a push button and the corresponding functional status is visually indicated. These units are compatible with all 800G illuminated push button operators and the panel mount cover accessory (catalog number 800G-APMC). correct handling of the product. Keep these instructions for future reference as they must be available throughout the expected life of the product. Contact Block (Screw Termination Certifications ATEX IECEx UKEx CCC INMETRO Gas Protection Type Dust Type (with 800G-APMC cover only) Ambient Temperature Range Power Module (Screw Termination) • Module: CML 17 ATEX 1107 U • Module and cover: CML 17 ATEX 1118 X • Module: IECEx CML 17.0047U • Module and cover: IECEx CML 17.0056X Service Temperature Range (Screw Termination) • Module: CML 17 ATEX 1108 U • Module and cover: CML 17 ATEX 1118 X • Module: CML 21 UKEX 11394 U • Module and cover: CML 21 UKEX 11395 X • Module: 2020322304001834 • Module and cover: 2020322304002149 • Module: UL-BR 14.0567U • Module and cover: UL-BR 14.0568X • Module: II 2 G Ex db eb IIC Gb • Module and cover: II 2 G Ex db eb IIC T6 Gb II 2 D Ex tb IIIC T80°C Db IP 66 -55…+40 °C (-67…+104 °F) @ 16 A -55…+60 °C (-67…+140 °F) @ 11 A Power Module with Contact Block • Module: IECEx CML 17.0048U • Module and cover: IECEx CML 17.0056X • Module: CML 21 UKEX 11393 U • Module and cover: CML 21 UKEX 11395 X • Module: 2020322310002148 • Module and cover: 2020322304002149 • Module: UL-BR 14.0566U • Module and cover: UL-BR 14.0568X -55…+50 °C (-67…+122 °F) or 60 °C (140 °F) if Ue ≤26.4V -55…+85 °C (-67…+185 °F) Mechanical and Electrical Ratings Rated Insulation Voltage Power Consumption 690 V — Rated Voltage (Ue) AC 250V and 400V; DC 24V and 110V Illumination Colors (LED) Contact Options Utilization Category (AC) Utilization Category (DC) — 1 N.O./1 N.C., 2 N.O., 2 N.C. AC-12: 16 A, 400V, AC-15: 10A, 400V Conventional Thermal Current (Ithe ) Conductor Size Degree of Protectio 300 V ≤1W Ta <50 °C (122 °F): 12…250V AC, 12…60V DC Ta <60 °C (140 °F): 12…24V AC/DC Red, green, blue, white, or yellow — — — 1 N.O., 1 N.C AC-15: 1 A, 230V DC-13: 0.25 A, 24V DC-13: 1A, 24V, DC-13:0.5 A, 110V 16 A/40 °C (104 °F) — — 11 A/60 °C (140 °F) 0.75 - 2.5 mm2 (18...14 AWG) IP20 (module only); IP64/IP66 (module and operator); IP66/IP67 (module, operator, and cover) DIR 10001129318 (Version 03) 2/4 Installation instruction for BUL.800G, Latch Mount Back-of-Panel Modules Additional Contact Block and Power Module Information Front-of-panel operators are inserted into a mounting hole in an “Ex e” enclosure or control panel. The respective back-of-panel module is connected to the operator using a bayonet lock. The conductor connection is made by wiring the conductors to terminals at the back of the contact block, power module, or power module with contact block combination unit. Panel Mount Cover (Catalog Number 800G-APMC) The panel mount cover accessory allows a conductor cable to be connected to the latch mount contact block, power module, or power module with contact block combination unit through a cable gland. The cover provides an increased ingress protection (IP) rating and is connected to the back-of-panel component by tightening two screws. Special Conditions for Safe Use The contact block, power module, and power module with contact block devices must be installed in a manner that protects against mechanical damage and electrostatic charges. Harmonized/Designated Standards Conformed To Contact Block, Power Module, and Power Modules with Contact Block Components • EN 60079-0 • EN 60079-1 • EN 60079-7 • IEC 60079-0 • IEC 60079-1 • IEC 60079-7 Back-of-Panel Components with Panel Mount Cover Accessory Installed • EN 60079-0 • EN 60079-1 • EN 60079-7 • EN-60079-31 • IEC 60079-0 • IEC 60079-1 • IEC 60079-7 • IEC 60079-31 Assemble, Install, and Commission Configured Catalog Number (Installed) Cat. No. Components 800G-XLSxZ-EX 800G-XLSx-EX + 800G-APMC 800G-DLSxZ-EX 800G-DLSx-EX + 800G-APMC 800G-DLSxXxZ-EX 800G-DLSxXx-EX + 800G-APMC Compatibility ATTENTION:Risk of serious injury due to incorrect assembly, installation, and commissioning. • Only qualified personnel are allowed to assemble, disassemble, install, and commission the device. • Protect devices against mechanical damage or electrostatic discharge. • Use suitable tools and install cable firmly. Contact blocks, power modules, and power module with contact block combination units are compatible with specific front-of-panel operators. Back-of-Panel Front-of-Panel Contact block Non-illuminated operator Power module Pilot light Power module and contact block Illuminated push button Safety Instructions Improper installation can cause malfunctioning and the loss of explosion protection. All back-of-panel modules and operators can only be used within the specified ambient temperature range (depending on the voltage and current). Use in areas other than those areas specified or the modification of the product by anyone other than the manufacturer is not permitted and exempts Rockwell Automation from liability for defects and any further liability. The applicable statutory rules and other binding directives that relate to workplace safety, accident prevention, and environmental protection must be observed. • Use cable that is rated with an appropriate temperature range suitable for the application. Assemble and Disassemble — Modules IMPORTANT The components that are pictured within this publication serve as an example of all back-of-panel modules. To mount the contact block or power module, follow these steps: “Click” 1. Verify that the contact block or power module is intact (no cracks). 2. Confirm the back-of-panel module is compatible with the installed operator (see Compatibility ). 3. Position the bayonet lock facing toward the mounted front-ofpanel operator. 4. Turn the locking bolt to secure the contact block or power module to the front-of-panel operator. Installation — Modules In hazardous areas, the contact block or power module must be used: Before you commission or restart operation, check compliance with all applicable laws and directives. • In appropriate enclosures with “Ex e” increased safety type of protection. The clearance and creepage distances under IEC/ EN 60079-7 Clauses 4.3 and 4.4 must be observed. All back-of-panel modules can be used only if they are in a clean and undamaged condition. Do not modify these modules in any way. • In an enclosure that corresponds to another approved type of protection that is specified in IEC/EN 60079-0 Clause 1. Publication 800G-IN003C-EN-P- May 2022 DIR 10001129318 (Version 03) Installation instruction for BUL.800G, Latch Mount Back-of-Panel Modules Take care when following these steps to connect the cable: 10. Tighten the sealing nut (6) with a torque of 1.3 N·m / 11.5 lb·in (lock nut (7) has a max. torque of 0.6 N·m / 5.3 lb·in). 1. Strip 40 mm (1.575 in.) of sheath off the cable. 2. Remove approximately 6 mm (0.236 in.) of insulation from the conductors. 11. If necessary, remove the label (8), mark it, and reinstall. 3. Prepare the ends of the fine-stranded and multi-stranded conductors. Crimp wire end sleeves with suitable crimp tools. Connection cross-sections: 0.75...2.5 mm2 (18...14 AWG). Commissioning — Cover and Modules 4. Open terminal cage and insert conductors. Before commissioning, check the following: 5. Tighten the terminals to a torque range of 0.4…0.7 N·m (3.5…6.2 lb·in). • The device has been installed in compliance with regulations. • The device is not damaged. • The connection has been established properly (verify that the conductors are secure). Terminals Contact Block 1 N.O. and 1 N.C. Contact 2 N.C. Contacts 2 N.O. Contacts 13 21 11 21 13 23 14 22 12 22 14 24 Power Module Maintenance ATTENTION: Risk of serious injury due to incorrect maintenance. Power Module with Contact Block X1 1 N.O. 3 1 N.C. X1 1 X1 • Only qualified personnel are allowed to do any maintenance and fault clearance. X2 You must keep the contact block, power module, and panel mount cover devices in good condition, operate them properly, monitor them, and clean them regularly. • IEC/EN 60079-17 must be observed. X2 4 X2 2 Assemble/Disassemble — Panel Mount Cover To install the panel mount cover, follow these steps: 1. Verify that the cover and the fitted sealing are intact (no cracks). 2. Install the sealing gasket (1) with the round side facing downwards into the groove of the back-ofpanel device. 3. Strip 40 mm (1.575 in.) sheath from the cable and remove approx. 6 mm (0.236 in.) insulation from the conductors. 4. Open the sealing nut (2) enough to allow the cable to be inserted. 5. Feed the cable (3) into the cable gland on the cover until there is sufficient length available for preparing the cable connection. 6. Close the sealing nut (2). 7. Connect the conductors (4) as shown in Installation — Modules . 8. Push the panel mount cover firmly onto the contact block, power module, or power module with contact block combination unit. 9. Tighten the screws (5) with a torque of 0.5…0.6 N·m (4.4…5.3 lb·in). Publication 800G-IN003C-EN-P - May 2022 • Check all contact blocks, power modules, panel mount covers, and cables regularly for cracks and damage. Verify that they are properly installed. IMPORTANT Do not clean contact blocks, power modules, or power module with contact block combination units with compressed air. Repair and Replacement ATTENTION: Defective contact blocks, power modules, and panel mount covers cannot be repaired; they must be replaced. • Back-of-panel devices are defective if the contact block does not function properly or the status indicator does not illuminate on the power module. • Devices must be replaced with an equivalent catalog number from the manufacturer. • Panel mount covers are defective if they are damaged or if the cable no longer fits securely to maintain IP rating. Accessories and Replacement Parts For more accessories and replacement parts that Rockwell Automation offers, see https://ab.rockwellautomation.com/Push-Buttons/ Hazardous-Location/800G . DIR 10001129318 (Version 03) 3/4 4/4 Installation instruction for BUL.800G, Latch Mount Back-of-Panel Modules Disposal At the end of its life, this equipment must be collected separately from any unsorted municipal waste. Follow all local and national requirements for disposal of this product. 136 (5.35) 130 (5.1) Panel Mount Cover and Panel Mount Panel Mount Cover and Panel Mount Power Approximate Dimensions Dimensions are shown in millimeters (inches). 68 (2.7) 68 (2.7) Power Module (Cat. No. 800G-DLSxZ-EX) Module with Contact Block (Cat. No. 800G-DLSxXx-EX) Declaration of Conformity Ø 19 (0.75) Contact Block (Cat. No. 800G-XLSx-EX) Power Module (Cat. No. 800G-DLSx-EX) 68 (2.7) 38 (1.5) 72 (2.8) Ø 19 (0.75) Power Module with Contact Block (Cat. No. 800G-DLSxXx-EX) 57 (2.24) 38 (1.5) 104 (4.1) 76.5 (3) 72 (2.8) Panel Mount Cover Panel Mount Cover and Panel Mount (Cat. No. 800G-APMC) Contact Block (Cat. No. 800G-XLSxZ-EX) Rockwell Automation, Inc. declares that the 800G-XLSx-EX, 800G-DLSx-EX, and 800G-DLSxXx-EX Series A latch mount contact blocks, power modules, and power module with contact block units are in compliance with Essential Health and Safety Requirements of Directive 2014/34/EU (ATEX) and Derective UKSI 2016:1107(as amended) as follows: • Equipment Group II, Equipment Category 2 • Type of Protection “Ex db eb IIC Gb” • Compliance to standards EN 60079-0:2018, EN 60079-1:2014, and EN 60079-7:2015+A1:2018 per ATEX Type Examination Certificates CML 17ATEX1107U and CML 17ATEX1108U; and UKEx Type Examination Certificate CML 21UKEX11394U and CML 21UKEX11393U Hereby, Rockwell Automation, Inc. declares that the 800G-XLS*ZEX, 800G-DLS*Z-EX, and 800G-DLS*X*Z-EX Series A latch mount contact blocks, power modules, and power module with contact block units with the panel mount cover accessory installed (800G-APMC) are in compliance with Essential Health and Safety Requirements of Directive 2014/34/EU (ATEX) and Directive UKSI 2016:1107 (as amended) as follows: • Equipment Group II, Equipment Category 2 • Type of Protection “Ex db eb IIC Gb / Ex tb IIIC T80°C Db IP66” • Compliance to standards EN 60079-0:2018, EN 60079-1:2014, and EN 60079-7:2015+A1:2018 per ATEX Type Examination Certificates CML 17ATEX1118X and UKEx Type Examination Certificate CML 21UKEX11395X The full text of the EU declarations of conformity is available at the following website: http://www.rockwellautomation.com/global/certification For Technical Support, visit rok.auto/support. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Product certificates are located in the Rockwell Automation Literature Library: rok.auto/certifications. EEE Yönetmeliğine Uygundur. expanding human possibility TM AMERICAS: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: 414.382.2000, Fax: (1) 414.382.4444 EUROPE/MIDDLE EAST/AFRICA: Rockwell Automation NV, Pegasus Park, De Kleetlan 12a, 1831 Diegem, Belgium, Tel: (32) 2663 0600, Fax: (32) 2663 0640 ASIA PACIFIC: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2501846 Publication 800G-IN003C-EN-P - May 2022 Copyright © 2021 Rockwell Automation, Inc. All Rights Reserved. Printed in USA. DIR 10001129318 (Version 03 ) ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- Hazardous area use
- Self-cleaning contacts
- Positive break operation
- Compatibility with 800G operators
- Panel mount cover accessory
- Power modules
- Visual status indication
- Illuminated push button operators
Frequently asked questions
These modules are used in hazardous areas for activating machine functions and visually indicating their status.
They are compatible with all 800G non-illuminated operators and the panel mount cover accessory. They can also be used with illuminated push button operators when a power module with contact block is used.
These modules have various certifications, including ATEX, IECEx, UKEx, CCC, and INMETRO.