Allen-Bradley 193 E100, 193-EGJ and 193-ERR Installation Instructions
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Bulletin 193 E100 Ground Fault / Jam and Remote Reset Module Application and Installation At the end of its life, this equipment should be collected separately from any unsorted municipal waste. (Cat 193-1EGJ, 193-1ERR) WARNING: Only personnel familiar with the module and associated machinery should plan to install, start up, and maintain the system. Failure to comply may result in personal injury and/or equipment damage. WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. Follow NFPA70E requirements. WARNING: Do not use automatic reset mode in applications where unexpected automatic restart of the motor can cause injury to persons or damage to equipment. WARNING: The module contains ESD (electrostatic discharge)-sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing, or repairing this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Rockwell Automation publication 8000-4.5.2, "Guarding Against Electrostatic Damage", or any other applicable ESD protection handbook. WARNING: Do not apply external voltage to R1, R2, S1 and S2. Equipment damage may occur. Installation with 100-C CLICK 2 4 3 USE THE CONTACTOR ADAPTER THAT IS NOT MARKED IN THIS LOCATION CLICK 1 Installation with 100-E CLICK 1 3 4 USE THE CONTACTOR ADAPTER THAT IS MARKED "B" IN THIS LOCATION 2 CLICK Wiring Diagram # Wires Range 2 With Remote Indication Display Torque 0.2…2.5 mm Stranded / Solid / 1 Wire (24...12 AWG) 0.55 N•m Flexible Stranded 0.2…1.0 mm 2 (5 lb-in) w/ Ferrule 2 Wires* (24...16 AWG) *FOR MULTIPLE CONDUCTOR APPLICATIONS THE SAME SIZE AND STYLE WIRE MUST BE USED. Recommend use of twisted pair for remote reset and ground fault sensor, 24 AWG Minimum R2 S2 193-CBCT+ S1 (Cat 193-ERID, 193-1ERIDN) R1 Wire Type R1 A2 A1 24 - 240V 47-63 HZ or DC +Please see 193-CBCT* instructions for CT wiring and selection. A2 A1 R2 Main Connections 2 Bulletin 193 E100 Ground Fault / Jam and Remote Reset Module Settings Changes to settings will not take effect when the motor is running. Adjustment Settings Communication Loss DIP Switch Left Trip on COM Loss: Down Don't Trip on COM Loss: Up DIP Switch Right Not Used Not Used Jam Level (%FLA) Jam Detection Disabled. Setting on Jam Delay Ignored. OFF 125…600 Jam Warning/Trip Level 125…600 % FLA Jam Delay (Sec) 0.1…10 Jam Trip Delay Set to 0.1…10 s Ground Fault Level (Amp) Ground Fault Detection Disabled OFF 0.02…5 Ground Fault Detection Set to 0.02…5 A Status LED: The status LED will indicate the module status by flashing a red trip code. The number of flashes followed by a pause identifies the specific trip code as follows: (1) - Overload Trip, (2) - Phase Loss, (3) - Ground Fault, (5) - Jam, (8) - Short Circuit, (10) - COM Loss, (11) - Test Trip Green flash - module powered Green solid - module powered plus motor current present Amber flash - warning Red flash - fault detected and overload relay tripped Red solid - hardware fault: internal hardware fault detected and overload relay trip attempted. Recover fault by cycling overload relay accessory supply voltage If hardware fault is encountered, the user could: a) verify that supply voltage is within limits; b) veriy that wiring to the terminals is correct; c) verify that the pins which connect the accessory to the overload relay are not damaged or misaligned; d) verify that operating temperature of the devices are within specification limits; e) refer to user manual for additional support. 193-1EGJ Maximum Frequency Turns Current Ratio Catalog Number Sensor Window I.D. Sensor Type Customer Sensor Termination 193-CBCT1 45A 50/60 Hz 1000:1 19.1 mm (.75 in.) Supplied 193-CBCT2 90A 50/60 Hz 1000:1 39.6 mm (1.56 in.) Ring Lug Required 193-CBCT3 180A 50/60 Hz 1000:1 63.5 mm (2.5 in.) Ring Lug Required 193-CBCT4 420A 50/60 Hz 1000:1 82.3 mm (3.25 in.) Ring Lug Required Maximum Recommended Cable Size 8 AWG @ 600V (10mm²) 2 AWG @ 600V ( 35mm²) Ref: IEC Ref: Contactor NEMA Catalog Contactor Number Size 100-C09 THRU 00....2 100-C37 100-C09 THRU 100-C85 250MCM @ 600V 100-C09 (120mm²) THRU 100-D180 350MCM @ 600V 100-C09 (10mm²) THRU 193-1ERR For a three phase system with one cable per phase Pour un système triphasé avec un câble par phase Für ein 3-Phasen-System mit einer Leitung pro Phase Para un sistema de tres fases con un cable por fase Para um sistema trifásico com um cabo por fase Per un sistema trifase con un cavo per fase 00....3 00....4 00....5 For a three phase system with two cables per phase. Pour un système triphasé avec deux câbles par phase. Für ein dreiphasiges System mit zwei Kabeln pro Phase. Para un sistema de tres fases con dos cables por fase. Per un sistema trifase con due cavi per fase. Para um sistema trifásico com dois cabos por fase. 100-D420 Ground Fault/Jam Operation Motor Status Stopped Star ng At Speed Ground Fault Protec on Enabled Disabled Enabled Jam Protec on Disabled Disabled Enabled Accessories Panel Mount Installation Adjustment Cover Installation (Cat 193-1EMC) 1 (Cat 193-1EIKIT1) 2 0.8 x 2.5 mm MAX mm [in.] For Technical Support, visit rok.auto/support. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Product certificates are located in the Rockwell Automation Literature Library: rok.auto/certifications. EEE Yönetmeliğine Uygundur. expanding human possibility TM AMERICAS: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: 414.382.2000, Fax: (1) 414.382.4444 EUROPE/MIDDLE EAST/AFRICA: Rockwell Automation NV, Pegasus Park, De Kleetlan 12a, 1831 Diegem, Belgium, Tel: (32) 2663 0600, Fax: (32) 2663 0640 ASIA PACIFIC: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2501846 Publication 193-IN082D-EN-E - May 2022, Supersedes 193-IN082C-EN-E - November 2021 Copyright © 2022 Rockwell Automation, Inc. All Rights Reserved. Printed in USA. PN-510674 DIR 10004184772 (Version 03) ">

Public link updated
The public link to your chat has been updated.
Advertisement