The Allen-Bradley 440G-EZ Interlocking Safety Switch is designed for door position monitoring. It features a magnetic locking device for process protection, ensuring safety by preventing unauthorized access or operation. The switch is compatible with various mounting options, including surface and flush mount. The 440G-EZ also supports mounting multiple safety switches with proper spacing, allowing for customized safety solutions.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Original Instructions 440G-EZ Interlocking Safety Switch Catalog Numbers 440G-EZS21STL05J, 440G-EZS21STL05H ATTENTION: Read this document and the documents that are listed in Additional Resources on page 4 about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions, and requirements of all applicable codes, laws, and standards. Only suitably trained personnel must perform activities including installation, adjustments, commissioning, use, assembly, disassembly, and maintenance in accordance with applicable code of practice. If this equipment is used in a manner that the manufacturer does not specify, the protection that is provided by the equipment may be impaired. Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Updated Figure 3 table. Replaced Table 2. Added IP69K to enclosure ingress rating in Specifications table. Intended Use The 440G electromagnetic switch is suitable for monitoring the position of guard doors. It has a magnetic locking device for process protection only. ATTENTION: Locking force is not monitored. Locking force is not a safety-related function. Mount Multiple Safety Switches IMPORTANT Figure 1 - Spacing Requirement [mm (in.)] Page 2 3 3 260 (10.24) 260 (10.24) Installation Installation of the 440G-EZ safety switch must be in accordance with the following steps and stated specifications and implemented by suitably competent personnel. The unit is not to be used as a mechanical stop. Guard stops and guides must be mounted. Adherence to the recommended maintenance instructions forms part of the warranty. ATTENTION: The presence of spare actuators can compromise the integrity of the safety systems. Personal injury or death, property damage, or economic loss can result. Appropriate management controls, working procedures, and alternative protective measures should be introduced to control their use and availability. WARNING: Do not defeat, tamper, remove, or bypass this unit. Severe injury to personnel could result. This device must be provided with a 24V DC PELV or SELV power supply that conforms to the requirements of 414-3 of IEC 60364-4-41 where provisions have been taken to confirm that, even if an internal fault is present, the voltage at the outgoing terminals cannot exceed 60V DC. Improper selection or installation of the devices affects the integrity of the safety systems. When several safety switches are mounted, the minimum distance between the individual systems must be followed to avoid mutual interference. Mounting The sensor can be mounted in the following ways: • • Surface mount — The sensor is mounted on the fixed part of the protective device (for example, door frame). Flush mount — The sensor is mounted in the fixed part of the protective device (for example, door frame). There must be a suitable recess in the mounting surface. The thickness of the mounting surface must be between 1.5…3 mm (0.06…0.12 in.) For recess dimensions for flush mounting, see Figure 4 on page 4. IMPORTANT Install the safety switch horizontally to help increase protection against manipulation. 440G-EZ Interlocking Safety Switch Installation Instructions Mount the Sensor 1. Mount the Actuator Unscrew the fixing screw (hexagon socket, 2 mm [0.08 in.]) and remove the cover plate. 1. 2. Align the actuator to the mounted sensor. Mount the actuator on the moving part of the protective device (for example, door) with 4 x M4 screws. Tightening torque: 1 N•m (8.9 lb•in). Use disposable screws if possible. • Maximum angle between sensor and actuator when protective device is closed: 3° ≤3° 3. Cover drill holes of the actuator with protective caps. Wiring 2. Mount the sensor on the fixed part of the protective device with 4 x M4 screws and secure it with four nuts. • For surface mount: mount the sensor on the fixed part of the protective device. The screws can be set in the front or the back. Figure 2 - Device Connection Pin Assignment (Male Connector, M12, 5-pin, A-coded) 2 1 5 3 4 Pin Wire Color (1) Designation 1 Brown +24V DC Safety switch voltage supply 2 White OSSD 1 Safety output 0V DC voltage supply Description 3 Blue 0V 4 Black OSSD 2 Safety output 5 Gray Magnet Magnet activation 24V DC (1) Applies to the extension cables recommended as accessories. Tightening torque: 1 N•m (8.9 lb•in) IMPORTANT Pay attention to tightness of the plug connector. Figure 3 - Device Connection Pin Assignment (Male Connector, M12, 8-pin, A-coded) • For flush mount: mount the sensor in the fixed part of the protective device. 2 3 8 4 1 5 7 6 Pin Tightening torque: 1 N•m (8.9 lb•in) 3. 4. 2 (1) (2) Set cover plate on the sensor. Tighten the fixing screws to 1 N•m (8.9 lb•in). Wire Color (1) Designation Description Application diagnostic output (not safe) 1 White Aux 2 Brown +24V DC Safety switch voltage supply 3 Green Magnet Magnet activation 24V DC 4 Yellow OSSD IN2 Safety input (2) 5 Gray OSSD 1 Safety output 6 Pink OSSD 2 Safety output 7 Blue 0V 8 Red OSSD IN1 0V DC voltage supply Safety input (2) Applies to the extension cables recommended as accessories. When used as an individual safety switch or as the first safety switch in a cascade apply 24V DC. IMPORTANT Pay attention to tightness of the plug connector. Rockwell Automation Publication 440G-IN019C-EN-P - November 2020 440G-EZ Interlocking Safety Switch Installation Instructions Status Indicators Specifications The switch has two status indicators: Attribute 440G-EZS21STL05J, 440G-EZS21STL05H Functional Safety Data (Guard door sensing) • PFHd= 1.5 x 10-8 at 40 °C (104 °F) and 1000 m (3280.8 ft) above sea level • Mission time/PTI: 20 years Table 1 - Status Indicator States Operating Characteristics 1 Item 1 2 (1) Name Color OSSD Green/Red LOCK Yellow Open 8-pin 5-pin (1) (2) 15 mm (0.59 in.) Safe switch off distance 45 mm (1.77 in.) Holding force 500 N Retaining force 25 N Maximum actuation frequency 0.5 Hz Alignment tolerance for locking device • Vertical: 5 mm (0.2 in.) • Horizontal: 5 mm (0.2 in.) 2 Aperture angle 3° Offset tolerance 5 mm (0.2 in.) • Green when the OSSD pair is in the ON state. • Red when the OSSD pair is in the OFF state. (1) Rated voltage 24V DC Insulation voltage Ui 32V Turns ON when the magnet is supplied with voltage. Rated impulse withstand voltage Uimp 1.5 kV Table 2 - Switch Status During Normal Operation Door/Guard Status 4 mm (0.16 in.) Typical switch on distance Description When a load is applied to the application diagnostic output that is too high, the red OSSD status indicator remains continuously ON. The actual switching behavior of the safety switch is not affected. Pins Safe switch on distance OSSD Inputs (1) On or Off OSSD Indicator Red AUX Status Off OSSD Outputs Off Closed On Green On (2) On (2) Open Off Red Off Off Closed Off Red Off Off Open — Red — Off Closed — Green — On (2) OSSD input only available for use with 8-pin version. The AUX output and OSSD outputs are OFF if the device is in a fault state. Maintenance Supply voltage when an individual safety switch is connected 24V DC (19.2…28.8 V DC) Class 2 supply Supply voltage UV when a cascade is connected • Sensor: 24V DC (22.8…28.8 V DC) Class 2 supply • Magnet: 24V DC (21.6…28.8 V DC) Class 2 supply Power consumption • Locking active: 350 mA • Locking deactivated: 50 mA Switching frequency ≤0.5 Hz Type of output OSSD Maximum Output current ≤100 mA Diagnostic output ≤25 mA, short-circuit protected Cable capacitance 400 nF (for OUT A and OUT B) Response time 50 ms Enable time 100 ms Risk time 100 ms Power up delay 2.5 s Muting time when supply voltage is interrupted 4 ms Environmental Operating temperature -20…+55 °C (-4…+131 °F) Frequency Description Storage temperature -25…+70 °C (-13…+158 °F) • Ensure the alignment of the actuator to the switch and the correct operation of the switching circuit. • Check for signs of abuse or interference. • Inspect the switch casing and actuator for damage and replace if needed. Relative humidity 50% at 70 °C (158 °F) (IEC 60947-5-2) Every week Enclosure ingress rating IP67, IP69K EMC IEC EMC: EN IEC 61326-3-1, EN IEC 60947-5-2, EN IEC 60947-5-3 • • • • • Vibration resistance 1 mm/10…55 Hz (IEC 60068-2-6) Shock resistance 30 g, 11 ms (IEC 60068-2-27) At least every 6 months Isolate all power. Remove the lid and end cover. Inspect all terminals for tightness. Clean out any accumulation of fine dirt. Check for any sign of wear of damage, for instance, actuator wear, cam assembly wear, contact oxidization and replace if needed. • Replace cover and tighten screws to specified settings. • Reinstate the power and check for correct operation. • Reapply tamper evident varnish or similar compound for mountings. Repair If there is any malfunction or damage, make no attempts at repair. Replace before machine operation is allowed. IMPORTANT Do not dismantle the unit. Outputs Safety outputs 2 x OSSDs, 2 x PNP, max 100 mA, short-circuit protected and overload-proof Auxiliary output 25 mA max, short-circuit protected (resistive load) Switching voltage • ON State: 19.2…28.8 V DC • OFF State: 0…2 V DC Switching current • ON State: ≤100 mA • OFF State: ≤500 µA Test pulse duration 300 µs Weight Sensor 510 g (18 oz) Actuator 210 g (7.4 oz) Material Sensor housing Anodized aluminum Actuator housing Fiberglass-reinforced PVC Anchor plate Nickel-plated steel Rockwell Automation Publication 440G-IN019C-EN-P - November 2020 3 Approximate Dimensions Figure 6 - Sensor [mm (in.)] 122 (4.8) Figure 4 - Flush Mounting [mm (in.)] 44 (1.73) 15.2 (0.60) 14.4 (0.57) 42 (1.65) 22 (0.87) 22 (0.87) 28 (1.10) 4.5 (0.18) 44 (1.73) 44 (1.73) 5.7 (0.22) Ø5 (0.20) x 4 L Figure 5 - Actuator [mm (in.)] (1) 120 (4.72) 16.8 (0.66) 16.8 (0.66) 10 (0.39) 44 60 (1.73) (2.36) 12.5 (0.49) 32 (1.26) 83.5 (3.29) 6.5 (0.26) 14.4 (0.57) Ø42 (1.65) 16.3 (0.64) 5.5 24 (0.22) 34 (1.34) (0.94) 14.5 (0.57) (1) 120 (4.73) L = 150±2 mm (5.91±0.79 in.) Additional Resources These documents contain additional information concerning related products from Rockwell Automation. 44 (1.73) 60 (2.36) 44 (1.73) Resource Description 440G-EZ Interlocking Safety Switch User Manual, publication 440G-UM003 Provides information that is needed during the lifecycle of the 440G-EZ safety switch. Industrial Automation Wiring and Grounding Provides general guidelines for installing a Rockwell Automation industrial system. Guidelines, publication 1770-4.1 Product Certifications website: rok.auto/certifications 4x 4.5 (0.18) 32 (1.26) Provides declarations of conformity, certificates, and other certification details. You can view or download publications at rok.auto/literature. Waste Electrical and Electronic Equipment (WEEE) At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. For technical support, visit rok.auto/support. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, expanding human possibility, Guardmaster, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 440G-IN019C-EN-P - November 2020 | Supersedes Publication 440G-IN019B-EN-P- June 2020 Copyright © 2020 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. 10005248682 Ver 02 8025119/19G3/2020-11-03 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Door Position Monitoring
- Magnetic Locking Device
- Surface and Flush Mount
- Multiple Switch Mounting
- OSSD Outputs
- IP67, IP69K Enclosure Rating
- Diagnostic Output
Frequently asked questions
The 440G-EZ is used to monitor the position of guard doors. It provides a magnetic locking device for process protection, preventing unauthorized access and ensuring safety.
It can be mounted in two ways: surface mount on the fixed part of the protective device, or flush mount in a suitable recess. The manual provides detailed instructions and dimensions for both mounting types.
The OSSD (Output Safety Signal Device) outputs are used to send safety signals to other devices in the safety system. The 440G-EZ provides two OSSD outputs that are PNP and short-circuit protected.