The Allen-Bradley GuardShield Muting Distribution Block is designed for quick and easy setup of Bulletin 450L-E GuardShield safety light curtains in muting applications. It supports both 2- and 4-sensor muting configurations, allowing for customized safety solutions. The distribution block can be used with RightSight polarized retroreflective muting sensors, as well as other compatible sensors.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Original Instructions GuardShield Muting Distribution Block Catalog Numbers 450L-AMOD-MUT-8, 800F-MUT-2-MS ATTENTION: This muting distribution block is used only in combination with the Bulletin 450L GuardShield™ safety light curtains. Installation Table 2 - Two Principal Installation Options Setup Description Summary of Changes 1 2 Muting distribution block that is connected to the connection plug-in (Cat. No. 450L-APR-MU-8 Two-sensor muting (see Figure 3) on port 5) and to the cascading plug-in (Cat. No. 450L-APC-IO-8 on port 4) 3 Muting distribution block that is connected to the connection plug-in (Cat. No. 450L-APR-MU-8 Four-sensor muting (see Figure 4) on port 5) and to the cascading plug-in (Cat. No. 450L-APC-IO-8 on port 4) This publication contains updates to Table 4 on page 2. Description The muting distribution block allows for quick setup and fast implementation of a Bulletin 450L-E GuardShield safety light curtain in applications that require muting. The muting distribution block can be used for 2- and 4-sensor muting. The desired muting type functionality must first be set with DIP switches at the Bulletin 450L GuardShield muting connection plug-in (catalog number 450L-APR-MU-8). Details for the DIP switch settings, the confirmation procedure, and installation hints for the muting sensors are provided in publication 450L-UM001. Figure 1 - Bulletin 450L Muting Distribution Block Remark Muting distribution block that is connected to the connection plug-in only (Cat. No. 450L-APR-MU-8 on port 6) Two-sensor muting (see Figure 2) Depending on the risk assessment, some muting applications require an override switch and a muting lamp. We offer a pre-assembled Bulletin 800F muting station with integrated muting lamp and reset/override keyswitch. This muting station allows a quick connection of these components to the muting distribution block. For the connection examples in this document, the RightSight™ polarized retroreflective muting sensor (catalog number 42EF­P2MPB­F4) is recommended [reflector (catalog number 92-93) and tilt-swivel mounting bracket (catalog number 60-2649)]. Other sensors that we offer can also be used if the pinning and the output polarity match. Setup 1 includes two muting sensors, a muting distribution block connected to the Bulletin 450L plug-in (catalog number 450L-APR-MU-8) only. Figure 2 - Setup 1 Tx Rx The muting distribution block can be mounted to the stand with two M4 (UNC 5/32) screws. The box cannot be mounted directly on the light curtain. Connection Plug-in 450L-APR-MU-8 Table 2 shows the setup options for the Bulletin 450L safety light curtain. Power Specifications Table 1 - Muting Distribution Block (Cat. No. 450L-AMOD-MUT-8) Attribute Value Body Size 191 x 24 x 28.4 mm (7.52 x 0.94 x 1.12 in.) See Figure 10 on page 4 Material PBT Screw hole size M4 Enclosure rating IP65 (all plugs that are connected and appropriately tightened) Operating temperature -10…+55 °C (14…131 °F) Supply voltage 24V DC ±20%, Class 2 Weight 140 g (4.94 oz) Certification c-UL-us, CE, RoHS, WEEE 800F-MUT-2-MS 6 5 4 3 2 1 0 Sealing Caps S1 S2 Safety Circuit ATTENTION: For Setup 1 (Figure 2), if the muting distribution block is connected to the Bulletin 450L connection plug-in, only the keyswitch at the muting station (catalog number 800F-MUT-2-MS) works. The orange muting indicator and the green OSSD status indicator on the muting station are always OFF. GuardShield Muting Distribution Block Installation Instructions Setup 2 includes two muting sensors, a muting distribution block connected to the connection plug-in (catalog number 450L-APR-MU-8), and the cascading plug-in (catalog number 450L-APC-IO-8). Pin Assignment Table 3 - Pin Assignments for Port 0 and Port 3 Description for Port 0 (Male, 8-pin) 2 3 8 1 Figure 3 - Setup 2 Rx Tx Cascading plug-in 450L-APC-IO-8 4 6 5 4 3 2 1 0 800F-MUT-2-MS Sealing Cap S1 S2 Safety Circuit For four sensor muting, two splitters (catalog number 879D-F5DM) Setup 3 has to be used to connect the cables of muting sensors S1-S4. Figure 4 - Setup 3 (1) Cascading plug-in 450L-APC-IO-8 Pin Number Setup 1 Setup 2 1 — AUX (OSSD emulation) Power 800F-MUT-2-MS A B S4 24V DC 24V DC 24V DC 3 Ground Ground Ground 4 — External device monitoring — 5 OSSD1 OSSD1 Reset (1)/Mute dependent override 6 OSSD2 OSSD2 Aux (muting or mute dependent override active) 7 0V 0V 0V 8 Reset (mute dependent override) Reset (mute dependent override) Muting lamp If configured at the connection plug-in, catalog number 450L-APR-MU-8. Description for Port 1 (Female, 5-pin) 1 A B S1 1 24V DC 24V DC S3 2 Sensor 4 Sensor 3 4 3 3 0V 0V 4 Sensor 2 Sensor 1 5 Not used Not used The pin assignment of port 4 matches the pin assignment of the cascading plug-in catalog number 450L-APC-IO-8 (for details see 450L-UM001). The pin assignment of port 5 and port 6 matches the pin assignment of the connection plug-in catalog number 450L-APR-MU-8 (for details see 450L-UM001). Cable Length, max [m (ft)] Cable Cat. No. (1) Safety controller or Port 0 of Bul. 450L safety monitoring relay in muting distribution block the control cabinet 30 (98.4) 889D-F8NB-x (2) Port 1 or 2 of Bul. 450L muting distribution block 10 (32.8) 889D-F5NCDM-x (2) Bul. 800F muting restart Port 3 of Bul. 450L muting and indication box distribution block 5 (16.4) 889D-F8NBDM-x (2) Cascading plug-in Port 4 of Bul. 450L muting (Cat. No. 450L-APC-IO-8) distribution block 2 (6.6) 889D-F8NBDM-x (2) Connection plug-in Port 5 or 6 of Bul. 450L (Cat. No. 450L-APR-MU-8) muting distribution block 2 (6.6) 889D-F8NBDM-x (2) Muting sensor 5 Pin Number Safety Circuit From Description for Port 2 (Female, 5-pin) 2 6 5 4 3 2 1 0 Follow these guidelines for maximum cable lengths: 2 — Table 4 - Pin Assignments for Port 1 and Port 2 Cable Lengths (2) 5 6 2 Connection plug-in 450L-APR-MU-8 (1) 7 6 Rx Tx S2 4 7 5 Connection plug-in 450L-APR-MU-8 Power Description for Port 3 (Female, 8-pin) 2 3 8 1 To The listed cable catalog numbers are for red cables. For other colors, visit ab.rockwellautomation.com/Connection-Devices/DC-Micro-Cordsets-and-Patchcords Replace the x with 2 (2 m [6.6 ft]), 5 (5 m [16.4 ft]), 10 (10 m [32.8 ft]), 15 (15 m [49.2 ft]), 20 [20 m (65.6 ft]), or 30 (30 m [98.4 ft]) for additional lengths. Rockwell Automation Publication 450L-IN005B-EN-P - March 2020 GuardShield Muting Distribution Block Installation Instructions Accessories Approximate Dimensions Figure 5 - 800F Muting Indication and Reset Block (Cat. No. 800F-MUT-2-MS) Figure 8 - Muting Cantilever Arm (Catalog Number 445L-AMSTDMUT) Dimensions [mm (in.)] Defined during installation 20 (0.79) 40 (1.57) 80 (3.15) 60 (2.36) The pre-assembled Bulletin 800F muting indication and reset block allows you to connect the muting indication, OSSD indication, and the reset/mute dependent override close to the light curtain. The use of this block is optional. The signal for reset/mute dependent overrides is also available at port 0 of the muting distribution block (see Table 3 on page 2), which is connected to the machine control. 500 (19.69) 503 (19.80) T-slot nut and screws for the RightSight bracket (catalog number 60-2649) are shipped with the cantilever arm. Attribute Value Housing 3-hole enclosure Size (body) 155 x 79 x 58 mm (6.10 x 3.11 x 2.28 in.) Enclosure rating IP66 Material PBT/polycarbonate blend Green ON OSSDs on Orange ON Muting or mute dependent override activated. Orange Blinking (1 Hz) • 90% ON/10% OFF: Timing error • 10%-ON/90%-OFF: Sequence error Orange OFF No muting Spring loaded keyswitch Reset Figure 9 - Mounting Stand (Cat. No. 445L-AMSTD2M) Dimensions [mm (in.)] (1)/mute dependent override Connector M12, 8-pin male Weight 380 g (13.4 oz) (1) 60 (2.36) 300 (11.81) Cover for Cable Gland Table 5 - Muting Indication and Reset Block for Cat. No. 800F-MUT-2-MS Indicators for Setup 2 (Table 2 on page 1) only 9.4 (0.37) 2000 (78.74) If configured at the connection plug-in, use catalog number 450L-APR-MU8. The yellow termination cap (included by default in the shipment of a Bulletin 450L muting distribution block), provides a seal rate of IP20. For applications that require a sealing rate of IP65, replace the yellow termination cap with a DC sealing cap (catalog number 889A-DCAP). 2015 (79.33) Figure 6 - IP65 Sealing Cap 60 (2.36) Figure 7 - T-connector for Four-sensor Muting Application (Cat. No. 879D-F5DM) 60 (2.36) 12 (0.47) 150 (5.91) 240 (9.45) Rockwell Automation Publication 450L-IN005B-EN-P - March 2020 3 Figure 10 - Distribution Box Dimensions [mm (in.)] 3.5 (0.14) 184 (7.24) 24 (0.94) 17 (0.67) Ø4.2 (0.16) 10.3 (0.4) 14.5 (0.57) 43 (1.69) 26 (1.02) 20.8 17 (0.67) (0.82) 14.8 (0.58) 28.4 (1.12) 184 (7.24) 191 (7.52) Waste Electrical and Electronic Equipment (WEEE) At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental information on its website at rok.auto/pec. Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. For technical support, visit rok.auto/support. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenkÖy, İstanbul, Tel: +90 (216) 5698400 EEE YÖnetmeliğine Uygundur Allen-Bradley, expanding human possibility, GuardShield, RightSight, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 450L-IN005B-EN-P - March 2020 | Supersedes Publication 450L-IN005A-EN-P - May 2019 Copyright © 2020 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. 10004745454 Ver 01 ">
Advertisement
Key features
- Supports 2- and 4-sensor muting
- Connects to Bulletin 450L safety light curtains
- Quick setup and installation
- IP65 enclosure rating
- Compatible with RightSight muting sensors
- Option for muting indication and reset block (800F-MUT-2-MS)
Frequently asked questions
This distribution block supports both 2- and 4-sensor muting configurations.
Yes, you can use other sensors if the pinning and output polarity match.
The maximum cable length for the connection between the muting distribution block and the muting sensors is 10 meters (32.8 feet).