Allen-Bradley 1492 Analog and Digital IO Conversion Module Installation Instructions
Allen-Bradley 1492 Analog and Digital IO Conversion Module allows you to convert legacy 1771 analog and digital I/O modules to newer 1756 ControlLogix modules without removing field wires. This conversion eliminates the need to rewire your existing system and offers a cost-effective way to upgrade your automation infrastructure. The module supports various configurations, including converting 1771 4-channel analog I/O modules to 1756 8-channel analog I/O modules, 1771 4-point digital I/O modules to 1756 8-point digital I/O modules, and more.
PDF
Download
Document
Advertisement
Advertisement
Analog and Digital I/O Conversion Module (Cat 1492-CM1771-LA003) I. Description This I/O Conversion Module provides for the conversion of (1) 1771, 4 Ch Analog I/O module to be converted to (1) 1756, 8 Ch Analog I/O module and consists of the following: (1) Conversion Module: 1492-CM1771-LA003 (1) Cable: 1492-CONACAB005E, 1492-CONACAB005E8V, or 1492-CONACAB005E8C (Table 2) (1) Conversion Mounting Assembly: 1492-MUA… (Table 1) This I/O Conversion Module provides for the conversion of (1) 1771, 4 Ch Analog I/O module to be converted to (1) 1756, 6 Ch Analog I/O module and consists of the following: (1) Conversion Module: 1492-CM1771-LA003 (1) Cable: 1492-CONACAB005E (Table 2) (1) Conversion Mounting Assembly: 1492-MUA… (Table 1) This I/O Conversion Module also provides for the conversion of (2) 1771 Digital I/O modules that also use the 1771-WC swing arm. In this case, this I/O conversion modules provide for the conversion of (2) 1771, 4 pt. Digital I/O modules to be converted to (1) 1756, 8 pt. Digital I/O module and consists of the following: (2) Conversion Module: 1492-CM1771-LA003 (1) Cable: 1492-C005005E8V or 1492-C005005E8C (Table 2) (1) Conversion Mounting Assembly: 1492-MUA… (Table 1) This I/O Conversion Module also provides for the conversion of (2) 1771 Digital I/O modules that also use the 1771-WC swing arm. In this case, this I/O conversion modules provide for the conversion of (2) 1771, 8 pt. Digital I/O modules to be converted to (1) 1756, 16 pt. Digital I/O module and consists of the following: (2) Conversion Module: 1492-CM1771-LA003 (1) Cable: 1492-C005005XS (Table 2) (1) Conversion Mounting Assembly: 1492-MUA… (Table 1) These conversions are accomplished without the removal of any field wires from the existing 1771 Swing Arms. The existing 1771 Swing Arms fit directly onto the edge connector of the 1492 Conversion Modules. For the Analog I/O conversions, one end of the 1492 Cable has (1) connector for the Conversion Module and on the other end is (1) Removable Terminal Block (RTB) for the 1756 I/O module. For the Digital I/O conversions, one end of the 1492 Cable has (2) connectors, one for each of the (2) Conversion Modules and on the other end is (1) Removable Terminal Block (RTB) for the 1756 I/O module. See the photos below. The I/O signals are routed through the 1492 Conversion Module(s) and the 1492 Cable to the appropriate terminals on the 1756 I/O module per the Wiring Diagrams in Section V. As standard, the 1492 Cables are 0.5M long, but we also offer a 1.0M cable length. Refer to the footnotes in Table 2 for further details. WARNING PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E Printed in U.S.A. De-energize and lockout any and all power to all I/O field devices connected to the A-B 1771 I/O chassis, and the power to the 1771 I/O chassis itself. Ensure all power is de-energized and locked out to any device in the control cabinet where the conversion is to be performed. Ensure work is performed by qualified personnel. (1) 1492-CM1771-LA003 Conversion Module Conversion Compatibility and Product I.D. Label 37-Pin Connector for cable 1492-CONACAB005E Conversion Compatibility and Product I.D. Label 37-Pin Connector for cable 1492-C005005__ Conversion Compatibility and Product I.D. Label 37-Pin Connector for cable 1492-CONACAB005___ PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (2) II. Installation The 1492 Conversion Modules must be installed in a 1492 Conversion Mounting Assembly (see Table 1 below). A complete System Installation Manual ships with the 1492 Conversion Mounting Assembly. 1) Determine the quantity of each type of 1771 I/O modules used in the 1771 I/O Chassis to be converted. 2) Select the applicable 1492 Conversion Modules from Table 2, Section III. 3) Review the Max Slots for I/O and Chassis Width data from the Table 1 below. 4) Select a 1756 I/O Chassis which has enough I/O Slots. NOTE: (2) I/O slots are required in the 1756 Chassis for conversions where (1) 1771 I/O module converts to (2) 1756 I/O modules. 5) Select the 1492 Conversion Mounting Assembly which has enough Conversion Module slots. NOTE: (2) Conversion Module slots are required in the 1492 Conversion Mounting Assembly for conversions where (2) 1771 I/O module convert to (1) 1756 I/O modules. NOTE: The 1492 Conversion Mounting Assembly has the same Height & Width foot-print as the 1771 Chassis and is designed to use the same mounting hardware. The combined Depth of the 1492 Conversion Mounting Assembly with the 1756 Chassis mounted on top is 10.25 inches (Controller w/key) or 10.0 inches (Controller w/o key). Dimension drawings are included in the System Installation Manual that ships with the 1492 Conversion Mounting Assembly. @ - # * + ( B C D E F G # C C D I 5 6 # K E L L I M E # " # # # * + ( 3 1 " 4 4 ( ) - Q A # 7 % ; 8 < * 4 ( 7 % = ; ? 8 : = * 5 0 7 % ; c T R J M K ! # $ % , . # * + - 6 # ( # & ' ( ) * 7 % 8 9 5 6 # 6 " ( 9 : * : * * 7 % 7 % 8 * 8 7 % 7 7 = 7 ! > % ; 7 % 8 7 % 8 = < * : < * : 8 * 8 < < < 8 8 < = 7 ! > % = ; 7 % 7 % : ? 8 * : : : % < * : = : < * : = 9 " ! < 9 D 1 < S ! K ) M P 2 R J / 4 R " 2 R * 2 - P 3 2 O , . 0 N - L ! / E d * . J , H ! A 8 < = 7 ! > 9 % 7 % : 7 % = < * 9 % 9 = = * 9 7 % 9 = = * 9 7 % 8 ; = 8 * : 7 % 8 < = 7 ! > % 8 7 % 7 % = 8 * : = < * : c 1771-A3B is not listed as it is used for 19 inch wide instrumentation panels. d Notice that the 1756 Chassis Width sometimes exceeds the 1771 Chassis Width, with or without the Power Supply. The CoverPlate of the 1492 Conversion Mounting Assembly allows the 1756 Chassis to be Left justified, Right justified or Centered. A complete System Installation Manual ships with the 1492 Conversion Mounting Assembly. PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (3) III. Compatibility q U W X Y Z [ \ ] v v w w v v v w w w w w w v v x x w x y x v y x { X Y Z [ \ ] v | w } | | x x } } y y x x y _ j v v v w w v w w v w w w w x v v w x v x x v x { | ~ ~ { | { Y ~ X l \ c } w ~ v v v v Foot Notes: cTo understand any issues concerning I/O module compatibility, refer to the Installation Manuals for the specific 1771 and 1756 I/O modules involved. dThe 3 numbers indicate the length of the 1492 Cable. Recommended cable lengths of 0.5M are shown. Additional cable lengths are as follows: 1.0M = 1492-CONACAB010E eThe 6 numbers indicate the cable length of each portion of the 1492 Cable. Recommended cable lengths of 0.5M / 0.5M are shown. Additional cable lengths are as follows: 1.0M / 1.0M = 1492-C010010 0.5M / 1.0M = 1492-C005010 1.0M / 0.5M = 1492-C010005 ④These cables have a maximum operating voltage of 160VDC, 2A maximum per pin, 12A maximum per cable. IV. Conversion Module Specifications (Operating specifications are when installed in the Conversion System base / cover-plate assembly) Specification Dimensions Approximate Shipping Weight Storage Temperature Operating Temperature Operating Humidity Shock Non -operating Operating Operating Vibration Maximum Operating Voltage Max. Module Operating Current Per Point: Per Module: Value 11.81 in. (height) x 4.38 in. (depth) x 1.5 in. (width) 300 mm. (height) x 111.25 mm (depth) x 38.1 mm (width) 250.6 g (0.55 lbs) (includes carton) -40 to +85 C (-40 to 185 F) 0 to 60 C (32 to 40 F) 5 to 95% at 60 C (non-condensing) 50g 30g 2g at 10 to 500Hz (Agrees with 1756 I/O module specification) 30 Vdc 2 Amps 12 Amps NOTICE PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E Agency Certifications Refer to the Wiring Diagram(s) for current limits for a specific configuraUL Classified: Under UL File Number E113724 CSA CE : compliant for all applicable directives Pollution Degree Environmental Rating 2 IP20 (4) \ Y | n \ l Y { | { | { | ~ | | | n t p n r | c | i | Z h | o g x x y Y y x y y x x v v x x v v v v v j c Z x b x v a x v w [ x v w w v v ` w w v U X w v [ w v x v i n v x h m x l x x g x v c x v } k x v v X v [ v } v ^ ~ v ] ~ z d z c ~ } Z z z b ~ } y y } a z z x x | w y y } } w v U [ x x | w v } } | v f ` | w w e _ | v v V ^ w w W v d v { { c v z z Z v { v y y b { z { z a z y x z y y x v U [ x v w v w v v w w U ` w w v V _ w v v ^ V u s V. Wiring Diagrams Conversion: 1771-OFE1 to 1756 -OF8I (Voltage) WARNING using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 d Cable 1492-CONACAB005E8Vc e £ ¤ ¡ ¨ « ¦ ¨ © ª § ¨ ª ¤ ¡ ¡ ª ¢ £ © ¡ ¬ © ¬ ¥ § ¨ ¥ ¨ ¢ ¦ § ª ¨ ­ ¤ ¦ ¢ © ¤ § « ¦ ¥ § ¡ ¦ ¢ ¥ ¢ 1756-OF8I 2 6 1 5 10 14 9 13 3 4 7 8 11 12 15 16 17 18 19 20 21 22 SH OUT_0/V RTN_0 OUT_1/V RTN_1 OUT_2/V RTN_2 OUT_3/V RTN_3 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. e d Conversion Module Installation and Application Considerations c Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) d shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-CONACAB005E8V] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e f Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and [Reference Doc: 10002306852] PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (5) V. Wiring Diagrams WARNING Conversion: 1771-OFE1 to 1756 -OF6VI (Voltage) There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 d Cable 1492-CONACAB005Ec e ® ¯ ° ¶ · ® ¯ º ± ´ » ¾ ¹ º ¹ º ¯ » ¼ ½ ± » ± ¯ ¯ ¯ ½ ³ ® ¿ ¼ ² ¿ ± ¸ µ º » ± ± ¸ ¯ » ¯ ´ ¹ º ½ » À · ± ¹ µ ¼ · ³ ¸ ° ³ ¹ ² ¯ ¯ ² ¾ ± ± ¼ ¶ µ · ³ ³ ½ ´ ² ² ¯ ¯ ´ µ ´ ± ® ¯ ° ± ® ¯ ° ¯ µ ¯ ¯ ¸ ° ± ® ¯ ° 1756-OF6VI 1 5 2 6 7 11 8 12 15 19 16 20 13 14 OUT-0 RTN-0 OUT-1 RTN-1 OUT-2 RTN-2 OUT-3 RTN-3 OUT-4 RTN-4 Not Used Not Used Not Used Not Used SH e d Conversion Module Installation and Application Considerations c Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF6VI [1492-CONACAB005E] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e The 1771-OFE1 analog output range was configured by jumpers, the output range for the 1756-OF6VI is software configured. Please ensure the correct output range is configured in the 1756-OF6VI. f Refer to your 1771-OFE1 and 1756-OF6VI Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E [Reference Doc: 41170-949] (6) V. Wiring Diagrams Conversion: 1771-OFE2 to 1756 -OF8I (Current) WARNING using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Current Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 1771-WC Swing Arm From 1771-OFE2 d e Cable 1492-CONACAB005E8Cc 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 Á Â Ã É Ê Á Â Â Í Ó Ì Í Â Î Ï Ð Ä Î Ä Â Â Â Ð Æ Á Ò Ï Å Ò Ä Ë È Í Î Ä Ä Ë Â Î Â Ç Ì Í Ð Î Ê Ä Ì È Ï Ê Í Ñ Ç Î Ñ Æ Ë Ä Æ Ì Å Â Ã Å Ì Ä Ä Ï É È Ê Æ Æ Ð Ç Å Å Ä Â Á Ä Â Ç Â Â Á È Ç Â Ã Â Ã Ë Ã Ä Á Â Ã È Â 1756-OF8I 4 6 3 5 12 14 11 13 1 2 7 8 9 10 15 16 17 18 19 20 21 22 SH OUT_0/I RTN_0 OUT_1/I RTN_1 OUT_2/I RTN_2 OUT_3/I RTN_3 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. e d Conversion Module Installation and Application Considerations c Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) d shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-CONACAB005E8C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e f Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and [Reference Doc: 10002306853] PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (7) V. Wiring Diagrams WARNING Conversion: 1771-OFE2 to 1756-OF6CI (Current) There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Current Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B Cable 1492-CONACAB005Ec 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE2 d Ô Õ Ü Ö Ý Ô × Õ Õ à Ú á ä ß ß × ã × × Ù Ù ã Ú Ú Û Û Õ × Ô Õ Ö × Ô Õ Ö Õ Õ Õ Õ Û Ý Ø Ø â Ú Ü Õ Õ â á Ù Ô å á Þ Ö × Ô Õ 1756-OF6CI 1 5 2 6 7 11 8 12 15 19 16 20 13 14 Õ ã à Õ × Þ â Ø å Õ á Û à á × × Þ æ Ý Õ Ú ß à ã á à × ß Û â Ý ä Þ × Ù ß Ù Õ Ö Ø Ø Ö OUT-0 RTN-0 OUT-1 RTN-1 OUT-2 RTN-2 OUT-3 RTN-3 OUT-4 RTN-4 Not Used Not Used Not Used Not Used SH d Conversion Module Installation and Application Considerations c Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF6CI [1492-CONACAB005E] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e IMPORTANT: The 1771-OFE2 module required the use of an external power supply to drive the analog device. The 1756-OF6CI analog output provides the drive power to the analog device. ENSURE the external power supply is REMOVED from the current loop before applying power to the 1756-OF6CI module or the analog output module may be damaged. f The 1771-OFE2 analog output ranges were factory set, the output range for the 1756-OF6CI is software configured. Please ensure the correct output range is configured in the 1756-OF6CI. g The 1756-OF6CI module can drive a load up to 550 ohms with the standard pre-configured cable [1492-CONACAB005E]. If greater than a 550 ohm drive current is required, the pre-wired cable can be modified at the 1756-OF6CI terminal block to drive up to a 1000 ohms. Refer to the 1756-OF6CI Installation Manual for modification details. h Refer to your 1771-OFE2 and 1756-OF6CI Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E [Reference Doc: 41170-948] (8) V. Wiring Diagrams Conversion: (2)1771-OFE1 to 1756 -OF8I (Voltage) WARNING using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B d 13 25 24 23 22 21 19 18 17 16 ç è é ï ð ç ê è è ê ì ó í ô ÷ ò î è ó ñ ù ÷ ò ô è ø e ë ì ì õ í ê ë ö î ê è ï ê ö ê ì ç ñ õ ö ó è ê ô ô õ ë ø è ð è ó ô ê ê î ò ó ö ô í ê ò õ ð ì ñ é ë ò ë è ð í ç ê è é è è î è è ç è í î é ñ é è ê ç è é 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 1756-OF8I 1492-C005005E8Vc Cable “A” 2 6 1 5 10 14 9 13 OUT_0/V RTN_0 OUT_1/V RTN_1 OUT_2/V RTN_2 OUT_3/V RTN_3 d SH e Conversion Module 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used 1771-WC Swing Arm From 1771-OFE1 d e A 0 1 2 3 4 5 6 7 B Cable “B” 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 ç è é ï ð ç ê è ê ì ó î ñ è ô ò ó è õ ê ô ö ê ë ë ö î ê è ð ì ì õ í ï ê è è ô ö ì ç ø è õ ë ø ê ñ î ó ô ê ê í ò ó è ö ô ù ð ê ò õ ð ó ÷ í ô ÷ ò ñ é ë ì è è ò ë è ê è í î í î è è ç è é ç è é ñ é ê ç è é d SH e 18 22 17 21 26 30 25 29 3 4 7 8 11 12 15 16 19 20 OUT_4/V RTN_4 OUT_5/V RTN_5 OUT_6/V RTN_6 OUT_7/V RTN_7 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 27 28 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Conversion Module Installation and Application Considerations c This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OF8I. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. d shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-C005005E8V] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e f Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (9) [Reference Doc: 10002306858] V. Wiring Diagrams Conversion: (2)1771-OFE2 to 1756 -OF8I (Current) WARNING using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Current Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 d ú û ü ú ý ü þ ý û ý û e þ ÿ þ ÿ ý û ý ú ý ÿ û û ý þ ý û ý ý ÿ ÿ û û þ û ú ý ü û û û û û ú û ü û ü ý ú û ü 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 1756-OF8I 1492-C005005E8Cc Cable “A” 4 6 3 5 12 14 11 13 OUT_0/I RTN_0 OUT_1/I RTN_1 OUT_2/I RTN_2 OUT_3/I RTN_3 d SH e Conversion Module 1492-CM1771-LA003 Current Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 d Cable “B” e ú û ü ú ý û ý ÿ ý ÿ û û ý þ þ û ÿ ÿ ý ú ý û û þ û ý ý û ý ü þ ÿ û û þ û ú û ü ý ú û ü û ý û û ü ý ú û ü d SH e 20 22 19 21 28 30 27 29 1 2 7 8 15 16 15 16 17 18 OUT_4/I RTN_4 OUT_5/I RTN_5 OUT_6/I RTN_6 OUT_7/I RTN_7 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Conversion Module Installation and Application Considerations c This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OF8I. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. d shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-C005005E8C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e f Refer to your 1771-OFE2 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (10) [Reference Doc: 10002306859] V. Wiring Diagrams WARNING Conversion: 1771-IG (2) to 1756-IG16 (1) There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Cable 1492-C005005XSc - + DC Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Common + 5V DC SUPPLY - Input Device + - A 0 1 2 3 4 5 6 7 B 1771-WC Swing Arm From 1771-IG 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 + " / 0 % & % ' & ( ' 1 2 . 1756-IG16 2 10 1 2 3 4 5 6 7 8 9 20 11 12 13 14 15 16 17 18 19 ' $ , # * ! ) . ( + DC -0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 - DC -0 + DC -1 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 - DC -1 SH Conversion Module 1492-CM1771-LA003 + DC Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Common + 5V DC SUPPLY - Input Device + - 1771-WC Swing Arm From 1771-IG A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 " + # % % ' $ , * ! ) & & ' ' ( ( - . / 0 1 2 / 2 SH Conversion Module Installation and Application Considerations c This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IG16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. d The input delay times for the 1771-IG module versus the 1756-IG16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IG 1ms (+/-10ms) 1ms (+/-10ms) 1756-IG16 w/ 1492-C005005XS 270ms max (plus selectable filter) 390ms max (plus selectable filter) e The 1771-IG module is rated 5V DC TTL INPUT MODULE. The 1756-IG16 module is rated 5V DC TTL INPUT MODULE only. f Refer to your 1771-IG and 1756-IG16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E [Reference Doc: 41171-027] (11) Conversion: 1771-OG (2) to 1756-OG16 (1) V. Wiring Diagrams WARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Cable 1492-C005005XSc S + DC Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Common + 5V DC SUPPLY - Output Device + - A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OG 3 4 5 ; < 3 6 4 > ? 6 9 @ C 6 < @ D P F G Q H 6 I M K J U V W X T 9 7 : 6 4 9 3 4 < 8 8 6 3 10 1 2 3 4 5 6 7 8 9 20 11 12 13 14 15 16 17 18 19 : 4 4 5 4 4 9 : 4 3 4 L 5 = K 5 M L N M 1756-OG16 X 5 4 R 6 7 B ; 4 B 6 A 8 6 3 = O A @ 7 4 6 @ B ? T 4 A > D 4 : ? @ 6 = E 9 > ? 4 B @ ? 6 > : A < > = 5 8 C 8 4 4 7 7 N + DC -0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 - DC -0 + DC -1 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 - DC -1 SH Conversion Module 1492-CM1771-LA003 + DC Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Common + 5V DC SUPPLY - Output Device + - A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OG 3 4 5 ; < 3 6 4 6 8 > ? 9 @ C C @ D G P H Q I J M 6 K K 9 : ; 6 4 < 7 8 8 B 6 4 9 3 3 4 : 9 : 4 4 4 5 4 5 = 5 4 R 6 7 A 8 6 4 B 6 @ 7 4 A B ? 3 = O F 6 6 @ A > D 4 4 ? @ 6 = E < 4 : > ? B @ ? 9 6 > : A < > 8 = 5 7 7 4 4 3 4 L L 5 M M N N S T U V W X U X SH Conversion Module Installation and Application Considerations c This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OG16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. d The input delay times for the 1771-OG module versus the 1756-OG16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-OG 1ms (+/-10ms) 1ms (+/-10ms) 1756-OG16 w/ 1492-C005005XS 45ms max (plus selectable filter) 145ms max (plus selectable filter) e The 1771-OG module is rated 5V DC TTL INPUT MODULE. The 1756-OG16 module is rated 5V DC TTL INPUT MODULE only. f Refer to your 1771-OG and 1756-OG16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. [Reference Doc: 41171-028] (12) PN-114289 DIR 10000060100 (Version 02) Publication 1492-IN047C-EN-E (7) Printed in U.S.A. PN-114289 ">
Advertisement
Key Features
- Legacy to ControlLogix conversion
- Field wire compatibility
- Analog and Digital I/O support
- Multiple module configurations
- Easy installation and application
Frequently Answers and Questions
What types of 1771 I/O modules can be converted using this module?
This module can convert a single 1771, 4 Ch Analog I/O module to a 1756, 8 Ch Analog I/O module or a single 1771, 4 Ch Analog I/O module to a 1756, 6 Ch Analog I/O module. It can also convert two 1771, 4 pt. Digital I/O modules to a single 1756, 8 pt. Digital I/O module or two 1771, 8 pt. Digital I/O modules to a single 1756, 16 pt. Digital I/O module.
How long are the standard cables provided with the conversion module?
The standard cables are 0.5M long, but a 1.0M cable length is also available. Refer to Table 2 in the viewed document for more information.
What are the operating temperature and humidity ranges for the conversion module?
The operating temperature range is 0 to 60 C (32 to 40 F), and the operating humidity range is 5 to 95% at 60 C (non-condensing). Refer to the 'Conversion Module Specifications' section of the viewed document for further details.