Allen-Bradley Embedded I/O Expansion Board is a versatile expansion module designed to enhance the functionality of your Allen-Bradley system. It provides 10 outputs, each capable of sinking or sourcing up to 0.5A of current, making it ideal for controlling a range of field devices. Featuring short-circuit protection and pilot duty rating, the board ensures reliable operation and safety. The board is compatible with the 1799ER-IQ10XOQ10 main board and can be mounted using stand-off rods. Flexible wiring options allow for various configurations, providing the user with a wide range of application possibilities.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Embedded I/O Expansion Board with 10 Outputs Catalog Number 1799-OQ10X Topic Page Important User Information 2 Environment and Enclosure 3 About the Board 4 Install the Board 6 Mount the Board 6 Connect the Board 8 Interpret the Status Indicators 11 Specifications 13 2 Embedded I/O Expansion Board with 10 Outputs Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING IMPORTANT ATTENTION Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and recognize the consequences. SHOCK HAZARD Labels may be on or inside the equipment (for example, drive or motor) to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment (for example, drive or motor) to alert people that surfaces may reach dangerous temperatures. Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 3 Environment and Enclosure ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances. This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA, V2, V1, V0 (or equivalent) if non-metallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. In addition to this publication, see: • Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 1770-4.1., for additional installation requirements. • NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Publication 1799-IN013B-EN-P - May 2013 4 Embedded I/O Expansion Board with 10 Outputs ATTENTION Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • Use a static-safe workstation, if available. • Store the equipment in appropriate static-safe packaging when not in use. ATTENTION ATTENTION ATTENTION Do not wire more than 2 conductors on any single terminal. To comply with the CE Low Voltage Directive (LVD), this equipment and all connected I/O must be powered from a source compliant with the following: Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV). To comply with UL restrictions, this equipment and all connected I/O must be powered from a source compliant with the following: 10…30V DC Class 2 Power Supply or a 10…30V DC UL Listed or Recognized Power Supply with isolated outputs limited to 200 volt-amperes in each ungrounded output line. This equipment and its power source must be mounted in a suitable enclosure with proper spacings maintained. About the Board The 1799-OQ10X is an expansion 10-point Output board that works only with 1799ER-IQ10XOQ10 as an expansion I/O module. This board has 10 outputs, that are self-protected 24V DC sinking or sourcing. Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 5 45076 Parts List Your package contains: • one 1799-OQ10X board. • ribbon expansion cable • four stand-off rods • four countersunk screws • four roundhead screws • these installation instructions. Required Hardware All mating connectors must be ordered separately. This table identifies the different connector and hardware options. Option Catalog Number Third-party Supplier & Part Number 2, 12-position, gold-plated I/O mating connectors 1799-12SPCON Phoenix - FK-MC 0.5/12-ST-2.5AU - 1923432 2-position plug for auxiliary power 1799-AUXCON Phoenix Contact, Part number MSTB2.5/2-ST-5.08 BK/AU 1765551) Publication 1799-IN013B-EN-P - May 2013 6 Embedded I/O Expansion Board with 10 Outputs Install the Board To install the board: • mount the board (on 1799ER-IQ10XOQ10). • connect the board (Auxiliary Power, I/O, ribbon expansion cable). More detailed information about each of these steps is in the following procedures. Mount the Board You can mount the board to the main board, 1799ER-IQ10XOQ10 using stand-off rods. 1. Place the four stand-offs onto the mounting screws and tighten them. 2. Place the screws through the expansion board into the stand-offs and tighten them. Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 7 DIN Rail DIN Rail Bracket or or 20 mm Stand-off 18 mm Mounting Plate 45074 3. Connect the expansion board to the base board with the ribbon expansion cable. IMPORTANT With the addition of the expansion board, the depth of the pair of boards is approximately 45 mm ( 1.77 in.). Publication 1799-IN013B-EN-P - May 2013 8 Embedded I/O Expansion Board with 10 Outputs Board Dimensions 67.1 mm ( 2.64 in ) 19.1 mm ( 0.75 in ) 11.4 mm ( 0.45 in ) 11.4 mm ( 0.45 in ) 87.6 mm ( 3.45 in ) 149.9 mm ( 5.90 in ) 44999 Connect the Board Use these illustrations and tables to help you connect the board. Output Connector (P2) Aux Power (P3 ) Expansion Board Connector (P1) 45076 Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 9 These tables identifies the signal for the connectors on the 1799-OQ10X. P3 Auxiliary Power Connector Pin Signal 1 24V DC 2 24V DC Ret P2 Output Connector Pin Signal 1 Output 0 2 Output 1 3 Output 2 4 24V DC Ret 5 Output 3 6 Output 4 7 Output 5 8 Output 6 9 24V DC 10 Output 7 11 Output 8 12 Output 9 Connect the Field Output Device to the I/O Connector (P3) The 1799-OQ10X board has outputs that supply current to your field output device (sourcing outputs) or sink current from your field output device (sinking outputs). Use these wiring diagrams to connect the outputs on this board. Publication 1799-IN013B-EN-P - May 2013 10 Embedded I/O Expansion Board with 10 Outputs Outputs Outputs (Sourcing) 0 1 2 24V dc 3 Return 4 5 6 24V dc 7 8 9 8 9 Load Outputs (Sinking) 0 1 2 24V dc 3 Return 4 5 6 24V dc 7 45081 Load Each output can be configured via a dip switch for sinking or sourcing output. Wire each output in accordance with your selected configuration. Default dip switch settings are at sinking output. Configure the switches before power-up. 10 9 8 7 6 5 4 3 2 1 O N OUT SINK OUT SOURCE 45073 Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 11 Interpret the Status Indicators This board has the following status indicators. • Power (1) • Individual output (10) Auxiliary Status Indicator I/0 Status Indicators 45075 Indicator Status Auxiliary status Output status Status Description Off No auxiliary power to device or input not valid. Green Auxiliary power applied to device. Off Output not energized. Yellow Output energized. Publication 1799-IN013B-EN-P - May 2013 12 Embedded I/O Expansion Board with 10 Outputs Communicate with Your Module 1799-OQ10X + 1799-OQ10X Data Definition (optional) Instance 161 - Consumed 20 Point Output Consumed Bit 7 Byte Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 Out7 Out6 Out5 Out4 Out3 Out2 Out1 Out0 1 Out15 Out14 Out13 Out12 2 Reserved 3 Reserved Out11 Out10 Out9 Out8 Out19 Out18 Out17 Out16 EtherNet/IP Connection with RSLogix 5000 The following instructions are for RSLogix 5000 version 17 or later. 1. Power down and connect the expansion board to base board. 2. Power up the board and obtain the IP address via DHCP. 3. In the General tab, click the Change button. 4. In the Module Definition screen, select 1799-OQ10X 10 Point 24V DC output for the expansion module. 5. Click the OK button, then click the Apply button. Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 13 Specifications Output Attribute Value Outputs per block 10 sinking or sourcing, 0.5A, short circuit protected, pilot duty Output auxiliary voltage 10...30V DC On-state voltage drop 250 mV max On-state current 0.5 A max Off-state leakage 20 μA max Card current (all outputs on) 4.0 A max Surge current - for 10ms, repeatable Every 2 s (individual outputs) 1.0 A General Attribute Value Auxiliary power voltage range 24V DC nominal (10...30V DC) Auxiliary power current outputs on 4 A max Auxiliary power current outputs off 36 mA Voltage rating Vi = 24V DC, Ii = 4A, Vout = 30V DC, Iout = 0.5A, Isurge=1A Dimensions (H x W x D), approx. 67.1 x 149.9 x 18 mm (2.64 x 5.97 x 0.71 in.) Weight, approx. 0.10 kg (0.22 lb) Enclosure type rating None (open-style) Pilot duty rating NEMA DC-14 Isolation voltage 50V (continuous), Basic Insulation Type, Outputs to System No isolation between individual Outputs, and Outputs to I/O (Aux) Power Type tested at 750V DC for 60 s. Publication 1799-IN013B-EN-P - May 2013 14 Embedded I/O Expansion Board with 10 Outputs General Attribute Value Power dissipation 1.12W @ 30V DC Auxiliary Power In I/O and auxiliary power wire size I/O: 0.13...0.5 mm² (26...20 AWG) solid or stranded copper wire rated at 75 oC (167 °F) or greater. 1.2 mm (3/64 in.) insulation max. Auxiliary power: 0.80...2.5 mm² (18...14 AWG) solid or stranded copper wire rated at 75 oC (167 °F) or greater. 1.2 mm (3/64 in.) insulation max. Wiring category(1) (1) 2 - on signal ports 2 - on power ports Use this Conductor Category information for planning conductor routing. Refer to publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines. Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20…70 °C (-4…158 °F) Temperature, storage IEC 60068-2-1 (Test Ab, Unpackaged Non-operating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Non-operating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Non-operating Thermal Shock): -40…85 °C (-40…185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5…95% non-condensing Vibration IEC60068-2-6 (Test Fc, Operating): 2 g @ 10…500 Hz Shock, operating IEC60068-2-27 (Test Ea, Unpackaged Shock): 30 g Shock, non-operating IEC60068-2-27 (Test Ea, Unpackaged Shock): 50 g Emissions CISPR 11: Group 1, Class A Publication 1799-IN013B-EN-P - May 2013 Embedded I/O Expansion Board with 10 Outputs 15 Environmental Specifications Attribute Value ESD immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kV at 5 kHz on power ports ±2 kV at 5 kHz on signal ports Surge transient immunity IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz Certifications (when product is marked)(1) Attribute Value c-UR-us UL Recognized Component Industrial Control Equipment, certified for US and Canada. See UL File E322657. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. Publication 1799-IN013B-EN-P - May 2013 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com. Installation Assistance If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your product up and running. United States 1.440.646.3434 Monday – Friday, 8 a.m. – 5 p.m. EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Allen-Bradley, TechConnect, RSLogix 5000, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1799-IN013B-EN-P - May 2013 Supersedes Publication 1799-IN013A-EN-P - March 2010 PN-204014 Copyright © 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. ">
Advertisement
Key features
- 10 outputs
- 0.5A sinking/sourcing
- Short circuit protection
- Pilot duty rating
- Compatible with 1799ER-IQ10XOQ10
- Stand-off rod mounting
- Flexible wiring options
Frequently asked questions
Each output of the 1799-OQ10X board can sink or source up to 0.5A of current.
The 1799-OQ10X board is specifically designed to work with the 1799ER-IQ10XOQ10 main board.
The output configuration is controlled by a dip switch. You can configure the outputs before powering up the board. The default configuration is for sinking outputs.