Allen-Bradley 1492 Field Conversion Module Installation Instructions
Allen-Bradley 1492 Field Conversion Module enables smooth transition from 1771 to 1756 I/O modules. It eliminates field wire removal, directly accommodating existing 1771 Swing Arms. The module's compact design and flexible cable options ensure seamless integration. The 1492 Conversion Module is compatible with a range of 1771 and 1756 I/O modules, providing reliable performance for your automation needs.
PDF
Download
Document
Advertisement
Advertisement
Digital I/O Conversion Module (Cat 1492-CM1771-LD006) I. Description This Digital I/O Conversion Module provides for the conversion of (1) 1771, 16 point I/O modules to be converted to (1) 1756, 16 point I/O module OR (1) 1771, 16 point I/O module to (2) 1756, 8 point I/O modules, and consists of the following: (1) 1771 Module (16pt) to (1) 1756 Module (16pt) (1) Conversion Module: 1492-CM1771-LD006 (1) Cable: 1492-CONCAB005X (Table 2) (1) Conversion Mounting Assembly: 1492-MUA… (Table 1) (1) 1771 Module (16pt) to (2) 1756 Module (8pt) (1) Conversion Module: 1492-CM1771-LD006 (1) Cable: 1492-CONCAB005S2 (Table 2) (1) Conversion Mounting Assembly: 1492-MUA… (Table 1) This conversion is accomplished without the removal of any field wires from the existing 1771 Swing Arms. The existing 1771 Swing Arm fits directly onto the edge connectors of the 1492 Conversion Module. On one end of the 1492 Cable is (1) connector for the Conversion Module. On the other end are (1) or (2) Removable Terminal Blocks (RTBs) for the 1756 I/O module(s), as shown in the photos below. The I/O signals are routed through the 1492 Conversion Module and the 1492 Cable to the appropriate terminals on the 1756 I/O module(s) per the Wiring Diagrams in Section V. As standard, the 1492 Cables are 0.5M long, but we also offer a 1.0M cable length. Refer to the footnotes in Table 2 for further details. Conversion Compatibility and Product I.D. Label 25-Pin Connector for cable 1492-CONCAB005X Cable 1492-CONCAB005S2 Conversion Compatibility and Product I.D. Label 37-Pin Connector for cable 1492-CONCAB005S2 1492-CM1771-LD006 Conversion Module WARNING PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E Printed in U.S.A. De-energize and lockout any and all power to all I/O field devices connected to the A-B 1771 I/O chassis, and the power to the 1771 I/O chassis itself. Ensure all power is de-energized and locked out to any device in the control cabinet where the conversion is to be performed. Ensure work is performed by qualified personnel. II. Installation The 1492 Conversion Modules must be installed in a 1492 Conversion Mounting Assembly (see Table 1 below). A complete System Installation Manual ships with the 1492 Conversion Mounting Assembly. 1) Determine the quantity of each type of 1771 I/O modules used in the 1771 I/O Chassis to be converted. 2) Select the applicable 1492 Conversion Modules from Table 2, Section III. 3) Review the Max Slots for I/O and Chassis Width data from the Table 1 below. 4) Select a 1756 I/O Chassis which has enough I/O Slots. NOTE: (2) I/O slots are required in the 1756 Chassis for conversions where (1) 1771 I/O module converts to (2) 1756 I/O modules. 5) Select the 1492 Conversion Mounting Assembly which has enough Conversion Module slots. NOTE: (2) Conversion Module slots are required in the 1492 Conversion Mounting Assembly for conversions where (2) 1771 I/O module convert to (1) 1756 I/O modules. NOTE: The 1492 Conversion Mounting Assembly has the same Height & Width foot-print as the 1771 Chassis and is designed to use the same mounting hardware. The combined Depth of the 1492 Conversion Mounting Assembly with the 1756 Chassis mounted on top is 10.25 inches (Controller w/key) or 10.0 inches (Controller w/o key). Dimension drawings are included in the System Installation Manual that ships with the 1492 Conversion Mounting Assembly. Table 1: Bulletin 1771 to 1756 Chassis Conversion 1771 Chassis 1756 Chassis Conversion Mounting Assembly (2) Cat. No. Max Slots for I/O 1771-A1B 4 1771-A2B 8 Chassis Width without Power Supply with Power Supply 9.01 12.61 14.01 17.61 Cat. No. Max Slots for I/O Chassis Width Cat. No. Max Slots for Conversion Modules Chassis Width 1492-MUA1B-A4-A7 4 9.01 1756-A4 3 10.35 1756-A7 6 14.49 1756-A7 1756-A10 6 9 14.49 19.02 1492-MUA2B-A7-A10 8 14.01 1771-A3B1 12 19.01 1756-A10 1756-A13 9 12 19.02 23.15 1492-MUA3-A10-A13 12 19.01 1771-A4B 16 24.01 1756-A13 1756-A17 12 16 23.15 29.06 1492-MUA4-A13-A17 16 24.01 (1) Foot Notes: 1771-A3B is not listed as it is used for 19 inch wide instrumentation panels. Notice that the 1756 Chassis Width sometimes exceeds the 1771 Chassis Width, with or without the Power Supply. The Cover-Plate of the 1492 Conversion Mounting Assembly allows the 1756 Chassis to be Left justified, Right justified or Centered. A complete System Installation Manual ships with the 1492 Conversion Mounting Assembly. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E (2) III. Compatibility Table 2: Bulletin 1771 to 1756 Conversion Modules and Cables 1756 1771 Digital I/O Module Digital I/O Module 1771-IGD 1756-IG16 1771-OAD 1756-OA16 1771-OBD 1756-OB16E 1771-OBDS 1756-OB16E 1771-OGD 1756-OG16 1771-OMD 1756-OA16 1771-OND 1756-ON8 (Qty 2) 1492 Conversion Module 1492-CM1771-LD006 1492-CM1771-LD006 1492-CM1771-LD006 1492-CM1771-LD006 1492-CM1771-LD006 1492-CM1771-LD006 1492-CM1771-LD006 1492 Cable 1492-CONCAB005X 1492-CONCAB005X 1492-CONCAB005X 1492-CONCAB005X 1492-CONCAB005X 1492-CONCAB005X 1492-CONCAB005S2 Foot Notes: )To understand any issues concerning I/O module compatibility, refer to the Installation Manuals for the specific 1771 and 1756 I/O modules involved. The 3 numbers indicate the cable length of each portion of the 1492 Cable. Recommended cable length of 0.5M is shown. Additional cable lengths are as follows: 1.0M = 1492-CONCAB010X or 1492-CONCAB010S2 The two 1756 modules must be located directly next to each other in the 1756 chassis. V. Conversion Module Specifications (Operating specifications are when installed in the Conversion System base / cover-plate assembly) Specification Dimensions Approximate Shipping Weight Storage Temperature Operating Temperature Operating Humidity Shock Non operating Operating Operating Vibration Maximum Operating Voltage Max. Module Operating Current Per Point: Per Module: Value 11.81 in. (height) x 4.38 in. (depth) x 1.5 in. (width) 300 mm. (height) x 111.25 mm (depth) x 38.1 mm (width) 250.6 g (0.55 lbs) (includes carton) -40 to +85°C (-40 to +185°F) 0 to 60°C (32 to 140°F) 5 to 95% at 60°C (non-condensing) 50g 30g 2g at 10 to 500Hz (Agrees with 1756 I/O module specifications) 132 Vac at 47 to 63Hz or 132 Vdc 2 Amps 4 Amps Agency Certifications Refer to the Wiring Diagram(s) for current limits for a specific configuration. UL Classified: Under UL File Number E113724 CSA CE: compliant for all applicable directives Pollution Degree 2 Environmental Rating IP20 NOTICE PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E (3) V. Wiring Diagrams Conversion: 1771-IGD to 1756-IG16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING Conversion Module 1492-CM1771-LD006 + - - DC Input Device + + dc + dc + dc + dc Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 08 Input 09 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 - dc E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-IG16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1771-IGD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IG16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-IGD module output current limits versus 1756-IG16 limits are as follows: a) Current/Point b) Current/Module 1771-IGD 122mA 500mA 1756-IG16 w/ 1492-CONCAB005X 110mA 110mA The 1771-IGD is rated 5V DC. The 1756-IG16 is rated 4.5V to 5.5V DC. Refer to your 1771-IGD and 1756-IG16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E [Reference Doc: 41171-004 (Version 00)] (4) V. Wiring Diagrams WARNING Conversion: 1771-OAD to 1756-OA16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD006 L1 L2 Output Device L1 L1 L1 L1 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 Cable 1492-CONCAB005X A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 E 1756-OA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L2-1 1771-WH, WHF, WHFB Swing Arm From 1771-OAD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OAD module output current limits versus 1756-OA16 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/point 1771-OAD 2A 8A 25A for 100ms 1756-OA16 w/ 1492-CONCAB005X 0.5A 4A 5A for 43ms The L2 terminal (Terminal E) on the 1771-OAD module was an optional connection, but it is required for the 1756-OA16. This connection must be added if it was not connected. The 1771-OAD is rated 10V to 138V AC. The 1756-OA16 is rated 74V to 256V AC. Refer to your 1771-OAD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E [Reference Doc: 41170-935 (Version 01)] (5) V. Wiring Diagrams (Cont’d) WARNING Conversion: 1771-OBD to 1756-OB16E There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD006 + dc + dc + dc + dc Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 + - - dc Output Device + L2 Cable 1492-CONCAB005X A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 E 1756-OB16E 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1771-OBD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OBD module output current limits versus 1756-OB16E limits are as follows: a) Current/Point b) Current/Module c) Surge Current/point 1771-OBD 2A 8A 4A for 10ms 1756-OB16E w/ 1492-CONCAB005X 1A 4A 2A for 10ms The 1771-OBD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OB16E is electronically fused per group. Refer to the 1756-OB16E Installation Manual for details on electronic fusing. The 1771-OBD is rated 10V to 60V DC. The 1756-OB16E is rated 10V to 31.2V DC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module. Refer to your 1771-OBD and 1756-OB16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E [Reference Doc: 41170-936 (Version 01)] (6) V. Wiring Diagrams (Cont’d) WARNING Conversion: 1771-OBDS to 1756-OB16E There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD006 + - - dc Output Device + + dc + dc + dc + dc Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 - dc E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OB16E 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1171-OBDS Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OB16E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OBDS module output current limits versus 1756-OB16E limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OBDS 1A 8A 4A for 10ms 1756-OB16E w/ 1492-CONCAB005X 1A 8A 2A for 10ms The 1771-OBDS has a single 12A, 250V rectifier fuse (1/4 x 1-1/4 inch). The 1756-OB16E is electronically fused per group. Refer to the 1756-OB16E Installation Manual for details on electronic fusing. The 1771-OBDS is rated 10V to 40V DC. The 1756-OB16E is rated 10V to 31.2V DC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module. Refer to your 1771-OBDS and 1756-OB16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E [Reference Doc: 41171-005 (Version 00)] (7) V. Wiring Diagrams (Cont’d) Conversion: 1771-OGD to 1756-OG16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING Conversion Module 1492-CM1771-LD006 + - - dc Output Device + + dc + dc + dc + dc Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 - dc E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OG16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1171-OGD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OG16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OGD module output current limits versus 1756-OG16 limits are as follows: a) Current/Point b) Current/Module 1771-OGD 1mA 310mA 1756-OG16 w/ 1492-CONCAB005X 24mA 384mA The 1771-OGD has a single 10A, 250V rectifier fuse (1/4 x 1-1/4 inch). The 1756-OG16 is electronically fused per group. Refer to the 1756-OG16 Installation Manual for details on electronic fusing. The 1771-OGD is rated 10V to 60V DC. The 1756-OG16 is rated 10V to 31.2V DC. Refer to your 1771-OGD and 1756-OG16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E [Reference Doc: 41171-006 (Version 00)] (8) V. Wiring Diagrams (Cont’d) Conversion: 1771-OMD to 1756-OA16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING Conversion Module 1492-CM1771-LD006 L1 L2 - LOAD + L1 L1 L1 L1 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L2 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green L1-0+ L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1+ L2-1 1771-WH, WHF, WHFB Swing Arm From 1771-OMD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OMD module output current limits versus 1756-OA16 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OMD 2A 8A 25A for 100ms 1756-OA16 w/ 1492-CONCAB005X 0.5A 4A 5A for 43ms The 1771-OMD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OA16 has a mechanical 3.15A @250V AC slow blow fuse. Refer to the 1756-OA16 Installation Manual for details on electronic fusing. The 1771-OMD is rated 184V to 250V AC. The 1756-OA16 is rated 74V to 265V AC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module. Refer to your 1771-OMD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E [Reference Doc: 41171-007 (Version 00)] (9) V. Wiring Diagrams (Cont’d) WARNING Conversion: 1771-OND to 1756-ON8 (2) There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Cable 1492-CONCAB005S2 Conversion Module 1492-CM1771-LD006 L1 L1 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L2 E L1 L1 L1 L2 Output Device 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red 1756-ON8 2 4 6 8 10 9 1 3 5 7 11 13 15 17 Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black 19 Black/White 14 16 18 20 Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red 1756-ON8 Red/Green 2 4 6 8 10 9 1 3 5 7 11 13 15 17 1771-WH, WHF Swing Arm From 1771-OND 19 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-ON8 RTB. Recommended cable lengths of 14 16 18 20 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OND module output current limits versus (2)1756-ON8 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OND 2A 8A 25A for 100ms 1756-ON8 w/ 1492-CONCAB005S2 2A 5A 20A for 43ms The L2 terminal (Terminal E) on the 1771-ON8 module was an optional connection, but it is required for the 1756-OA16. This connection must be added if it was not connected. The 1771-OND is rated 24V AC. The 1756-ON8 is rated 10V to 30V AC. Refer to your 1771-OND and 1756-ON8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E L1-0 L1-0 L1-0 L1-0 L1-0 NOT USED OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 NOT USED L1-1 L1-1 L1-1 L1-1 L1-1 [Reference Doc: 41171-008 (Version 00)] (10) L1-0 L1-0 L1-0 L1-0 L1-0 NOT USED OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 NOT USED L1-1 L1-1 L1-1 L1-1 L1-1 PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E (11) PN-114278 DIR 10000060089 (Version 01) Publication 1492-IN036B-EN-E Printed in U.S.A. ">
Key Features
- 1771 to 1756 conversion
- Swing arm compatibility
- Compact design
- Cable options
- I/O module compatibility
- UL, CSA, CE certified
Frequently Answers and Questions
What I/O modules can I convert using the 1492 Field Conversion Module?
Refer to Table 2 in Section III of the viewed document for compatible 1771 and 1756 I/O module pairs.
How do I install the 1492 Conversion Module?
The 1492 Conversion Module should be installed in a 1492 Conversion Mounting Assembly. Refer to the Installation Manual for instructions.
What are the dimensions of the 1492 Conversion Module?
The dimensions of the 1492 Conversion Module are 11.81 in. (height) x 4.38 in. (depth) x 1.5 in. (width).