Allen-Bradley DNet ArmorBlock Network Powered 8-input/8-output Module IN is a stand-alone 24V DC I/O module that communicates via the DeviceNet network. It features a sealed IP69K housing, requiring no additional enclosure for most applications. The module offers 8 inputs and 8 outputs, each with a 0.5 A current rating, and utilizes M12-style connectors for both I/O and network connections. This module is ideal for industrial environments where reliable, robust, and easily-installed I/O control is required.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions DeviceNet ArmorBlock Network Powered 8-input/8-output Module Catalog Number 1732D-8I8O1212D Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic Discharge 3 About the Module 4 Install the Module 5 Mount the Module 6 Communicate with Your Module 11 Interpret the Status Indicators 12 Specifications 14 2 DeviceNet ArmorBlock Network Powered 8-input/8-output Module Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING IMPORTANT ATTENTION Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and recognize the consequences. SHOCK HAZARD Labels may be located on or inside the equipment (for example, drive or motor) to alert people that dangerous voltage may be present. BURN HAZARD Labels may be located on or inside the equipment (for example, drive or motor) to alert people that surfaces may be dangerous temperatures. Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 3 Environment and Enclosure ATTENTION This equipment is intended for use in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 meters (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances. This equipment is supplied as enclosed equipment. It should not require additional system enclosure when used in locations consistent with the enclosure type ratings stated in the Specifications section of this publication. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings, beyond what this product provides, that are required to comply with certain product safety certifications. In addition to this publication, see: • Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1, for additional installation requirements. • NEMA Standards 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Prevent Electrostatic Discharge ATTENTION This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment. • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • Use a static-safe workstation, if available. • Store the equipment in appropriate static-safe packaging when not in use. Publication 1732D-IN010A-EN-E - April 2009 4 DeviceNet ArmorBlock Network Powered 8-input/8-output Module About the Module The DeviceNet 1732D ArmorBlock I/O family consists of stand-alone 24V DC I/O modules that communicate via the DeviceNet network. The sealed IP69K housing of these modules requires no enclosure. Note that it is possible that environmental requirements other than IP69K require an additional appropriate enclosure. I/O connectors are sealed M12 style. The DeviceNet network uses advanced network technology, producer/consumer communication, to increase network functionality and throughput. Visit our web site at http://www.ab.com/networks for producer/consumer technology information and updates. M12-style DeviceNet connectors Module status indicator DNet In DNet Out Network status indicator MOD NET I-0 I-7 O-0 O-7 I-1 I-6 Input status indicator (8) O-1 O-6 Output status indicator (8) I-2 I-5 O-2 O-5 I-6 I-4 O-3 O-4 12 mm I/O connector (8) 0 0 2 8 8 6 4 X10 2 6 Node address 4 X1 44762 Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 5 Catalog Number Explanation The catalog number 1732D-8I8O1212D identifies a DeviceNet 24V DC 8-port, with one input and one output per port, 8-input 8-output 0.5 A M12-style network connector module. Install the Module To install the module: • Set the node address • Mount the module • Connect the cord sets Set the Node Address Valid node addresses are 00 through 63. Set the node address using either the rotary switches, RSNetWorx for DeviceNet, DeviceNetManager, or another software configuration tool. Setting the switches at any number from 64 through 99 lets the software have address control. Each module is shipped set for node address 63. Remove the caps on the front of the module to access the switches. The two switches are: • X10 (most significant digit) - left side of module • X1 (least significant digit) - right side of module Publication 1732D-IN010A-EN-E - April 2009 6 DeviceNet ArmorBlock Network Powered 8-input/8-output Module To reset the node address: 1. Rotate the switches using a small blade screwdriver. 2. Line up the small black dot on the switch with the number setting you wish to use. 3. Cycle power. Example shows default node address set at 63. 43968 The rotary switches are read periodically. If the switches have been changed since the last time they were read and they no longer match the online address, a minor fault occurs, which is indicated by a flashing red MOD LED. Settings of 64 through 99 cause the module to use the last valid node address stored internally. For example, the last setting internally was 40. If a change is made to 68, and then you power up, the address defaults to 40. The module is equipped with AutoBaud detect. AutoBaud lets the module read the settings already in use on your DeviceNet network and automatically adjusts to those settings. Mount the Module Two sets of mounting holes are used to mount the module directly to a panel or machine. Mounting holes accommodate #6 (M3) pan head screws. The torque specification is 0.64 Nm (6 in-lb). Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 7 Product Dimensions Refer to the mounting dimensions illustration to help you mount the module. Module Dimensions 65 mm (2.56 in.) 43.25 mm (1.70 in.) 26.5 mm (1.04 in.) DNet In DNet Out MOD NET I-0 I-7 O-0 O-7 I-1 I-6 O-1 O-6 I-2 I-5 O-2 O-5 I-6 I-4 O-3 O-4 179 mm (7.05 in.) 169 mm (6.64 in.) 0 0 2 8 8 6 4 X10 2 6 4 X1 44761 Front view Side view Publication 1732D-IN010A-EN-E - April 2009 8 DeviceNet ArmorBlock Network Powered 8-input/8-output Module Mounting the Module in High Vibration Areas If you mount the module in an area that is subject to shock or vibration, we recommend that you use a flat and a lock washer to mount the module. Mount the flat and the lock washer as shown in the mounting illustration. Torque the mounting screws to 0.64 Nm (6 in-lb). Lock washer Flat washer 44766 Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 9 Connect the I/O Cord Sets to the Module The ArmorBlock DeviceNet family has 5-pin micro-style connectors. We provide caps to cover the unused connectors on your module. Connect the quick-disconnect cord sets that you selected for your module to the appropriate ports. Network Connector Refer to the pinout diagram for the network connector. M12-style Input Connectors Male Female (View into Connector) Pin 1 Drain Pin 2 V+ (Red) Pin 3 V- (Black) Pin 4 CAN_H (White) Pin 5 CAN_L (Blue) 44175 41452 I/O Connector Refer to the pinout diagram for the I/O connector. M12-style 5-pin Female Input Connector (View into Connector) Pin 1 Sensor Source Voltage Pin 2 Output Pin 3 Return Pin 4 Input Pin 5 PE 41452 Publication 1732D-IN010A-EN-E - April 2009 10 DeviceNet ArmorBlock Network Powered 8-input/8-output Module Refer to publication M116-CA001 for Rockwell Automation cable and cord set offerings or access the Connection Systems website at http://www.ab.com/sensors/products/connection_systems/. ATTENTION ATTENTION If any I/O devices connected to this equipment require Class 2 power to operate, this equipment and all connected I/O must be powered by a Class 2 source. To comply with the CE Low Voltage Directive (LVD), this equipment and all connected I/O must be powered from a source compliant with the following: Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV). Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP enclosure type requirements. Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 11 Communicate with Your Module This module’s I/O is exchanged with the master through a cyclic, polled, or change-of-state connection. Cyclic - allows configuration of the block as an I/O client. The block will produce and consume its I/O cyclically at the rate configured. Polled - a master initiates communication by sending its polled I/O message to the module. The module consumes the message, updates outputs, and produces a response. The response has input data. Change-of-State - productions occur when an input changes or a fault condition occurs. If no input or fault condition change occurs within the expected packet rate, a heartbeat production occurs. This heartbeat production tells the scanner module that the I/O module is alive and ready to communicate. Consumption occurs when data changes and the master produces new output data to the I/O block. Refer to the Module Data Definitions table for more information. 1732-8I8O1212D Data Definitions Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Produce 0 I7 I6 I5 I4 I3 I2 I1 I0 Produce 1 In short Out short Consume 0 O7 O6 O5 O4 O3 O2 O1 O0 Where: I=Input Data; 0=Off, 1=On In Short 0=Working, 1=Sensor Source Voltage Fault Out Short 0=Working, 1=Output Fault (Short) O=Output Data; 0=Off, 1=On Publication 1732D-IN010A-EN-E - April 2009 12 DeviceNet ArmorBlock Network Powered 8-input/8-output Module Interpret the Status Indicators This module has the following indicators: • Network status indicator for DeviceNet • Module status indicator for DeviceNet • Individual I/O status indicators for inputs and outputs DNet In Module status indicator I/O status indicators DNet Out MOD NET I-0 I-7 O-0 O-7 I-1 I-6 O-1 O-6 I-2 I-5 O-2 O-5 I-6 I-4 O-3 O-4 0 Network status indicator I/O status indicators 0 2 8 8 6 4 X10 2 6 4 X1 44762 Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 13 Indicator Status Description Network status Off Device is not online. - Device has not completed dup_MAC-id test. - Device not powered – check module status indicator. Green Device operating normally and is online with connections in the established state. As a Group 2 module, it means that the module is allocated to a master. Flashing green Device is online with no connections in the established state. Module status I/O status Red Critical link failure – failed communications module. Flashing red Recoverable fault – an I/O connection has timed out. Off No power applied to the device. Green Device is operating normally. Flashing green Device needs commissioning due to missing, incomplete, or incorrect configuration. Flashing red Recoverable fault – input or output short circuit. Red Critical fault – Device timed out or has an unrecoverable fault. Off Output is not energized or input is not valid. Yellow Output is energized or input is valid. Publication 1732D-IN010A-EN-E - April 2009 14 DeviceNet ArmorBlock Network Powered 8-input/8-output Module Specifications DeviceNet 1732 ArmorBlock Network Powered 8-input/8-output Module, Series A - 1732D-8I8O1212D Inputs Attribute Value Number of inputs 8 Off-state input voltage, max 5V DC On-state input voltage, max 25V DC On-state input voltage, nom 24V DC On-state input voltage, min 11V DC Sensor source voltage, max 25V DC Sensor source voltage, min 11V DC Off-state input current, max 1.5 mA @ 5V DC On-state input current, max 5 mA @ 25V DC Input delay time(1) OFF to ON ON to OFF 0…16000 μs (1) Input OFF to ON or ON to OFF delay is time from a valid input signal to recognition by the module. Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 15 DeviceNet 1732 ArmorBlock Network Powered 8-input/8-output Module, Series A - 1732D-8I8O1212D Outputs Attribute Value Number of outputs 8 On-state output voltage drop, max 0.5V DC Off-peak blocking voltage, min 25V DC On-state output voltage, max 25V DC On-state output voltage, min 11V DC On-state output voltage, nom 24V DC On-state output current, max 0.5 A Current per module, max 4 A (all outputs) Off-state output leakage current, max 50 μA Surge current per output, max 1.2 A for 10 ms, repeatable every 2 s Publication 1732D-IN010A-EN-E - April 2009 16 DeviceNet ArmorBlock Network Powered 8-input/8-output Module General Specifications Attribute Value Power consumption 2.2 W Power dissipation 11.2 btu/h Isolation voltage No isolation DeviceNet power voltage, max 25V DC DeviceNet power voltage, min 11V DC DeviceNet current 100 mA plus sum of sensor and output currents Sensor source current per module, max 500 mA Communication rate 125 Kbps @ 500 m (1640 ft) for thick cable, flat media length 375 m (1230 ft) 250 Kbps @ 200 m (600 ft) for thick cable, flat media length 150 m (492 ft) 500 Kbps @ 100 m (330 ft) for thick cable, flat media length 75 m (246 ft) Pilot duty rating Not rated Enclosure type rating Meets IP65/66/67/69K (when marked), and NEMA 4X/6P with receptacle dust caps or cable termination Wiring category(1) 1 - on signal ports 1 - on power ports 2 - on communications ports Indicators 1 green/red module status 1 green/red network status 8 yellow input status and 8 yellow output status Dimensions (HxWxD), approx. 179 x 65 x 43.25 mm (7.05 x 2.56 x 1.70 in.) Weight, approx. 0.392 kg (0.864 lb) (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 17 Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20…60 °C (-4…140 °F) Temperature, non-operating IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold), IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat), IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal Shock): -45…85 °C (-49…185 °F) Relative humidity IEC 60068-2-30 (Test Db, Un-packaged Damp Heat): 5…95% non-condensing Vibration IEC60068-2-6 (Test Fc, Operating): 5 g @ 10…500 Hz Shock, operating IEC60068-2-27 (Test Ea, Unpackaged Shock): 30 g Shock, non-operating IEC60068-2-27 (Test Ea, Unpackaged Shock): 50 g Emissions CSPR 11: Group 1, Class A ESD immunity IEC 61000-4-2: 8 kV contact dischargess 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 1V/m with 1 kHz line-wave 80% AM from 2000…2700 MHz Publication 1732D-IN010A-EN-E - April 2009 18 DeviceNet ArmorBlock Network Powered 8-input/8-output Module Environmental Specifications (Continued) Attribute Value EFT/B immunity IEC 61000-4-4: ±3 kV at 5 kHz on power ports ±3 kV at 5 kHz on signal ports ±2 kV at 5 kHz on communications ports Surge transient immunity IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports ±2 kV line-earth(CM) on communications ports Conducted RF IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150…80000 kHz immunity Publication 1732D-IN010A-EN-E - April 2009 DeviceNet ArmorBlock Network Powered 8-input/8-output Module 19 Certifications Certification (when Value product is marked)(1) c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions ODVA ODVA conformance tested to DeviceNet specifications (1) See the Product Certification link at http://www.ab.com for Declaration of Conformity, Certificates, and other certification details. Publication 1732D-IN010A-EN-E - April 2009 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com. Installation Assistance If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your product up and running. United States 1.440.646.3434 Monday – Friday, 8 a.m. – 5 p.m. EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Allen-Bradley, ArmorBlock, RSNetWorx for DeviceNet, DeviceNetManager, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1732D-IN010A-EN-E - April 2009 PN-43626 Copyright © 2009 Rockwell Automation, Inc. All rights reserved. ">
Advertisement
Key features
- IP69K sealed housing
- 8-input/8-output configuration
- 0.5 A current rating per port
- M12 connectors
- DeviceNet communication
- AutoBaud detection
- Cyclic, Polled, and Change-of-State communication modes
- Modular design for easy installation
Frequently asked questions
You can set the node address using the rotary switches on the front of the module, or through software configuration tools such as RSNetWorx for DeviceNet or DeviceNetManager. The default node address is 63.
The module can be mounted directly to a panel or machine using #6 (M3) pan head screws. Two sets of mounting holes are provided for this purpose.
The module features a network status indicator, a module status indicator, and individual I/O status indicators. Refer to the "Interpret the Status Indicators" section in the manual for detailed descriptions of each indicator's status and meaning.
The communication rate depends on the cable type and length. For thick cable, rates can range from 125 Kbps at 500 m (1640 ft) to 500 Kbps at 100 m (330 ft). Flat media has shorter maximum distances.