Allen-Bradley 1492 Fusible Interface Module is a versatile device designed for use in control systems. It provides a secure and reliable interface for connecting various I/O modules to a control system. The module features a removable terminal block for easy wiring and maintenance. It is compliant with industry standards for safe operation and suitable for hazardous environments.
PDF
Download
Document
Advertisement
Advertisement
Fusible Interface Module Module d’interface à fusible Schnittstellenmodul mit Sicherung Modulo di interfaccia con fusibili Módulo de interface con fusible (Cat 1492-IFM20F-F24A-2, -RIFM20F-F24A-2, -IFM20F-F120A-2, -RIFM20F-F120A-2) To prevent electrical shock, disconnect from power source before installing or servicing. FM Class 1, Div.2 requires device installation in a tool-accessible enclosure compliant with ANSI/ISA S82. AVERTISSEMENT Avant le montage et la mise en service, couper l'alimentation secteur pour éviter toutes décharges. FM Classe 1, Div. 2 nécessite l'installation de l'équipement dans une armoire accessible aux interventions, conforme à ANSI/ISA S82. Vor Installations- oder Servicearbeiten Strom-versorgung unterbrechen, um Elektroschocks zu vermeiden. FM-Klasse 1, WARNUNG Gruppe 2 erfordert die Installation des Gerätes in einem Gehäuse, das für Werkzeuge zugänglich ist und den Anforderungen gemäß ANSI/ISA S82 entspricht. Per prevenire infortuni, togliere tensione prima dell’installazione o manutenzione. FM Classe 1, Divisione 2 richiede AVVERTENZA l'installazione del dispositivo in un alloggiamento con capacità di accesso per strumenti conforme allo standard ANSI/ISA S82. Desconéctese de la corriente eléctrica, antes de la instalación o del servicio, a fin de impedir sacudidas eléctricas. El ADVERTENCIA requisito de FM (Factory Mutual) Clase 1, Div. 2, establece que el dispositivo debe instalarse en un envolvente que permita la introducción y uso de herramientas y cumpla con la norma ANSI/ISA S82. WARNING Fuse Clips and Blown Fuse Indicators: See page 3 for fuse installation/removal. Porte-fusibles et voyants de fusibles grillés: voir page 3 l'installation et le retrait des fusibles. Sicherungshalterungen und Anzeige einer durchgebrannten Sicherung. Ein-und Ausbau der Sicherung siehe Seite 3. Morsetti dei fusibili e indicatori dei fusibili bruciati: vedere il montaggio/smontaggio dei fusibili a pagina 3. Sujetadores de fusibles e indicadores de fusible fundido: Vea la página 3 para obtener información sobre la instalación/extracción de fusibles. Module Identification Area. Identification du module. Modulkennzeichnungsbereich Area per l'identificazione del modulo Area de identificación del módulo. = Connector Pin = Broche de connexion = Steckerstift = Pin del connettore = Pasador de conector 20 (IFM40...) 2 1 = Field-side Terminals = Borne exterieure = Feldseitiger Terminal = Terminale lato-campo = Terminal de campo 19 (IFM20...) B1 A1 Lower = A 1492-EAJ35 35 mm DIN Rail 199-DR1 199-DR4 1492-DR7 Upper = B 1 1 Adhesive Label Card. Provides terminal wiring identification and LED labels. Carte étiquette adhésive. Identifie le câblage des bornes et les étiquettes des LED. Aufklebbare Etiketten zur Kennzeichnung der Klemmenverdrahtung und LED-Anzeigen. Scheda etichette adesive. Fornisce l'identificazione del cablaggio dei terminali e le etichette LED. Tarjeta de etiquetas adhesivas. Proporciona identificación de cableado del terminal y etiquetas para los indicadores LED. PN-23246 DIR 40063-280 (Version 09) Printed in U.S.A. Module Installation / Removal Montage / Retrait Installation / Entfernen Montaggio / Smontaggio Instalación / Extracción Remvable Terminal Block Installation / Removal Montage / Retrait Installation / Entfernen Montaggio / Smontaggio Instalación / Extracción 1492-N90 1492-N90 3.5-4.5 lb-in (0.38-0.50 Nm) 2 2 1 0.32 in (8 mm) 1 2 #22-#12 AWG (0.2-4 mm2) Cu only Cu seulement nur Cu Solo Cu Cu solamente 3.5-4.5 lb-in (0.38-0.50 Nm) Applies to modules with fixed and removable (R) terminal block Cable Matrix Matrice des câbles Kabelmatrix Matrice cavi Matriz de cables I/O Module Module E/S E/A-Modul Modulo I/O Módulo de E/S 1746-IA16 1746-IB16 1746-IH16 1746-IN16 1746-ITB16 1746-OV16 1746-OVP16 1756-IA16 TC-IDA161 1756-IB16 TC-IDD161 1756-IN16 1756-IV16 1769-IA16 1769-IQ16 1769-IQ16F 1769-OV16 1771-IAD 1771-IBD 1771-ICD 1771-IND 1794-IB16 1794-IB8 1492-CABA69 Cables are available in 0.5m, 1.0m, 2.5m and 5.0m lengths (005=0.5m, 010=1.0m, 025 = 2.5m, 050=5.0m). Custom length cables also available. Contact local Sales Office for more information. Câbles disponibles en 0,5m, 1,0m, 2,5m et 5,0m de longueur (005=0,5m; 010=1,0m; 025=2,5m; 050=5,0m). Câbles sur mesure à la demande. Contactez e bureau le plus proche. Verfügbare Kabellängen 0,5m, 1,0m, 2,5m und 5,0m (005=0,5m; 010=1,0m; 025=2,5m; 050=5,0m). Anwenderspezifizifische Längen stehen ebenfalls zur Verfügung. Kontaktieren Sie bitte Ihr lokales Vertriebsbüro für weitere Informationen. I cavi sono disponibili in lunghezze di 0,5m, 1,0m, 2,5m e 5,0m (005=0,5m; 010=1,0m; 025=2,5m; 050=5,0m). Sono disponibili anche cavi su misura. Per ulteriori informazioni, contattare l’ufficio vendite locale. Cables disponibles en longitudes de 0,5m, 1,0m, 2,5m, 5,0m (005=0,5m; 010=1,0m; 025=2,5m; 050=5,0m). Hay disponibles cables de varias longitudes. Para más información comuníquese con la oficina de ventas. 1492-CABLEF Supports Removable Terminal Block (RTB) plug. Compatible screw style plug, 1492-RTB20N (pkg. qty. 2). Compatible push-in style plug 1492-RTB20P (pkg. qty. 2). Order plugs separately. 1492-CABLEA 1492-CABLEB 1492-CABLEB 1492-CABLEE 1492-CABLEE 1492-CABLEX 1492-HWCABX 1492-CABLEX 1492-CABLEX 1492-CABB69* 1492-CABB69* 1492-CABE69 1492-CABLEF 1492-CABLEF 1492-CABLEF 1492-CABA94 1492-CABA94 #22-#12 AWG (0.2-4 mm2) Cu only Cu seulement nur Cu Solo Cu Cu solamente Applies to modules with removable terminal block plugs (1492-RIFM_) 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-RIFM20F-F24A-2 1492-RIFM20F-F120A-2 1492-CABLEB 0.32 in (8 mm) 2 1492-CABLEB 1492-CABLEX 1492-HWCABX Cable is limited for use within the control panel unless it is run through conduit. Cable is ITC (Instrumentation Tray Cable) rated. *1769-IQ16, 1769-IQ16F I/O SINK MODE ONLY PN-23246 DIR 40063-280 (Version 09) (2) Pinout Brochage Anschlußbelegung Disposizione dei piedini Esquema de pins 1492-IFM20F-F24A-2 1492-RIFM20F-F24A-2 1492-IFM20F-F120A-2 1492-RIFM20F-F120A-2 1 B1 2 B2 3 B3 18 B18 19 B19 20 B20 A1 A11 A2 A3 A18 A19 Blown Fuse Indicator Circuit Circuit du voyant de rupture de fusible Anzeigeschaltung für durchgebrannte Sicherung Indicatore dei fusibili bruciati Circuito del indicador de fusible fundido A10 A20 Fuse Installation/Removal Installation/retrait des fusibles Ein- und Ausbau der Sicherung Montaggio/smontaggio dei fusibili Instalación/extracción de fusibles 5 x 20 mm (max. 2.0A per output; 12A per module) (2,0 A par sortie maximum; 12 A par module) (max. 2,0 A je Ausgang; 12 A je Modul) (max 2 A per uscita; 12 A per modulo) (2.0 A máx. por salida; 12 A por módulo) 1 3 GOULD 34-015G LITTELFUSE 097023 BUSSMAN FP-A3 2 2 1 4 PN-23246 DIR 40063-280 (Version 09) (3) I/O Wiring Data Wiring information for your I/O module, AIFM module and cable (e.g. wiring diagram and pinouts)are available online at www.rockwellautomation.com/en/e-tools. To obtain information follow this procedure. NOTICE 1) In the Catalog Number BOX at the above online site type in the catalog number of the IFM, AIFM, etc. module you are using and click on Submit. 2) At the next screen displayed, click on the Modify key (lower left of screen). 3) Click on the areas that indicate NO SELECTION and enter your specific configuration information (e.g. I/O platform, I/O MODULE, ETC.). NOTE: To obtain the wiring diagram, you must select th Pre-Wired Cable Connector selection. 4) Configure your 1492 cable by filing in the NO SELECTION areas. 5) Click on the ACCEPT key for the configured 1492 cable. At the next screen click on ACCEPT for the 1492 module. 6) The next screen (Configuration Results) displays the results of your specific configuration. The "supplementary Documents" column contains I/O wiring information for the configuration (e.g. I/O Wiring Diagrams). Specifications Spécifications Catalog No. Référence Bestell-Nr. N. Catalogo Referencia Technische Daten Specifiche Voltage Tension Spannung Tensione Voltaje 1492-IFM20F-F24A-2 10-30V AC/DC 1492-RIFM20F-F24A-2 1492-IFM20F-F120A-2 85-132V AC/DC 1492-RIFM20F-F120A-2 Especificaciones Current/Circuit Courant/Circuit Strom/Schaltkreis Corrente/circuito Intensidad/circuito Current/Module Courant/Module Strom/Modul Corrente/modulo Intensidad/módulo 2 Amps 12 Amps Operating Temperature Range Plage températures de fonctionnement Betriebstemperaturbereich Limiti temperatura di funzionamento Rango de temperatura de funcionamient 2.4 mA Maximum Recurring Peak Voltage Tension de crele réurrente maximale Maximale periodische Hochstspannung Tensione massima di cresta ricorrente Voltaje de cresta iterativo máximo Catalog No. Référence Bestell-Nr. N. Catalogo Referencia Indicator Circuit Current Courant circuit voyants Strom, Anzeigeschaltkreis Corrente circuito indicatori Intensidad del circuito de indicadores 0° C - 60° C 1.2 mA Humidity Humidité Feuchtigkeit Humedad Umidità Approx. Shipping Weight Poids d'embarquement approximatif Ungefähres Versandgewicht Peso approssimativo del carico Peso aproximado al momento de embarque Dimensions Dimensions Abmessungen Dimensioni Dimensiones Standards Normes Standards Standard Estándares cULus (File: E10314, Guide No. NRAG) Suitable for use in Class 1 Div 2 Groups A, B, C and D Hazardous and Non-Hazardous 4.33 in. (110 mm) W Locations. 3.27 in. (83 mm) H Temperature Code = T3C at 60°C CE: Compliant for all applicable directives 2.78 in (70.5 mm) D FM Class 1 Div 2 Groups A, B, C and D 1492-IFM20F-F24A-2 1492-RIFM20F-F24A-2 1492-IFM20F-F120A-2 1492-RIFM20F-F120A-2 600 Vp 5 - 95% .72 lb. (343 g.) Temperature Rating T3C = 60°C (J.I. 3000590, all except relay modules) For transients > 600 Vp use a UL recognized suppression device rated at 2.5 kV withstand. Pour des transitoires > 600 Vp utilisez un dispositif de suppression certifié UL à 2,5 kV nominal de tenue. Für Einschaltstöße > 600 Vp verwenden Sie einen UL anerkannten Entstörer, der bewertet wurde bei 2,5 kV standzuhalten. Per transitori > 600 Vp usare dispositivo di soppressione riconosciuto da UL capace di sopportare 2,5 kV. Para transitorios > 600 Vp use un dispositivo de supresión reconocido UL clasificado con 2,5 kV. Non-condensing Sans condensation Nicht kondensierend Senza condensa sin condensación Power, input and output (I/O) wiring must be in accordance with Class I Division 2 wiring methods - Artticle 501-10(B)(1) of the National Electrical Code. WARNING Explosion Hazard - substitution of components may impair suitability for Class I Division 2. Explosion Hazard - Do Not Disconnect Equipment unless power has been switched off or the area is known to be Non-Hazardous. Add 0.39 in. to the width dimension for 1492-Rxx type modules. SURGE SUPPRESSION follow the literature recommendations of the PLC module being used. SUPPRESSION DES SURTENSIONS se trouve à la suite de la littérature qui contient les recommandations relatives au module PLC utilisé. ÜBERSPANNUNGSSCHUTZ Bitte beachten Sie die Dokumentationsempfehlungen für das jeweils benutzte SPS-Modul. Per la SOPPRESSIONE DEI PICCHI TEMPORANEI, seguire le istruzioni riportate nella documentazione in dotazione al Modulo PLC utilizzato. SUPRESIÓN DE SOBRETENSIÓN, siga las recomendaciones indicadas en la documentación del módulo PLC respectivo. Reference Publications: Refer to 1770-4.1 and appropriate PLC I/O module installation manual. PN-23246 DIR 40063-280 (Version 09) Printed in U.S.A. ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Removable Terminal Block
- Class I Division 2 Compliant
- Secure Interface
- Easy Wiring
- Multiple Voltage Options
Frequently asked questions
The maximum current per output for the 1492-IFM20F-F24A-2 module is 2.0A. (viewed document)
The maximum current per module for the 1492-IFM20F-F24A-2 module is 12A. (viewed document)
The operating temperature range of the 1492-IFM20F-F24A-2 module is 0°C to 60°C. (viewed document)