Allen-Bradley 1494V Variable Depth Disconnect Switch Installation Instructions
Allen-Bradley 1494V Variable Depth Disconnect Switch is a robust and versatile component designed for various electrical applications. This switch features variable depth adjustment allowing installation in enclosures with different flange thicknesses, offering flexibility in design and installation. It's equipped with a disconnect handle with a built-in spring bracket and a defeater lever, ensuring reliable operation. This switch is designed for 400A applications and is available with both right-hand and left-hand mechanisms.
PDF
Download
Document
Advertisement
Advertisement
1 2 3 4 5 6 7 8 A Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator. Table of Contents Page Quick Installation Guide - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod 2 Quick Installation Guide (continued) - Connecting Rod Installation 3 Connecting Rod Adjustment Procedure 4 Enclosure Without Handle Cutout - Locate Handle - Drill Handle Holes 5 Door Catch Mounting Bracket Installation 6 Disconnect Switch Installation - Locate Disconnect Switch - Install Disconnect Switch - Assemble and Install Line Terminal Guard 7 Trailer Fuse Block Installation 8 Phase Barrier Replacement and Terminal Adapter Installation 9 Fuse Clip Installation 10 Bulletin 1494V Disconnect Switch Kit 11 Bulletin 1494V Disconnect Switch Kit Optional Accessory List 12 B C D E F G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. G. Ushakow CHKD. M. Jutz APPD. J. Koziczkowski DR. ANGLES: 42052 N/A DATE 12-03-07 12-03-07 DATE 12-03-07 DATE DWG. SIZE B SHEET 1 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A QUICK INSTALLATION GUIDE 1 Disconnect Switch Installation (Right hand installation shown. For left hand installation follow similar procedure.) Use template D to locate handle holes on mounting plate. 5 Overlay template E (400 A) over D . 5- 4 7 Install disconnect switch. 1/2 5 2 TO P B 2 P LE ND HA LE HO 11 Sw an E) TuOnch-TIT P r p (TA nte g Cermin fo TO TO RE HE E H SU F T UR US EA O OS FL IDE M IDE CL S N LD INS RE IN F E HOTO SU O O P O CL T EN F O TAPE M TTO BO d SaH re h thUitcE lesfoFr LwID TO Ho LsD h sS E RE HE gE hoOlewit IN UR SU F T tiUnR2" HedTO OS EA O unS 1/3 vid CL M IDEMCoL(4O) 1 pro EN S hENrill ws F IN c O itF d d scre O P A P TO LE ND HA ec Dis 3 D at 6 e (4 00 A) 3/4 h itc nn HsiTte si po RIG op de se E 1 (1) 58-0 52-1 420 ed in . U.S.A Print Center punch and drill (4) holes for 5/16-18 thread forming screws provided with switch. 9/32" Dia. 1 TT BO w tS co (U H US FL IDE TO LD INS RE RE HE E O U SU F T UR H TO OS EA O OS CL M IDE CL EN S N IN F E OF O P TO /2 pl m onn) n Te ti tio llaallatio ca e Lo stainst Hol Inhand ndleft Ha for 4- LE HO 6-1 TT BO D 90 -130 lb-in 2 Disconnect Handle Installation C 2 Install handle and spring bracket. 1 Install gasket. 3 Install defeater lever. 60-80 lb-in IMPORTANT: Apply grease to O-Ring to retain into handle groove. D 7-11 lb-in 3 Cutting Connecting Rod (Cut (2) Connecting Rods; first rod connects the handle to the switch, second rod provides stiffening for the enclosure flange) Mounting Plate Enclosure Working Depth (Inside Flange of Enclosure to Mounting Plate) 3 Remove burrs. 2 Measure, mark and 1 Measure working depth of enclosure. E cut (2) connecting rods. N /4" s inu N F 3-3 m (2) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------CHKD. - - - - - - APPD. - - - - - - DR. ANGLES: 42052 N/A DATE DATE DATE ------------------- DWG. SIZE B SHEET 2 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A QUICK INSTALLATION GUIDE (CONTINUED) 4 Connecting Rod Installation First rod connects the handle to the switch 1 Verify that disconnect switch and handle are in "OFF" position. (Switch blades will be visible) Pull rod up and verify if rod is touching bottom of spring bracket. (If not, rotate rod until it touches spring bracket) B 4 3 2 Drive Bar Rotate connecting rod into drive bar 16 turns. Zero Clearance C Hitch Pin 7 Connecting Rod 6 5 D Primary Link 8 Second rod provides stiffening for the enclosure flange 11 150 - 200 lb-in 9 E 10 ATTENTION: CHECK FOR PROPER OPERATION F (3) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------CHKD. - - - - - - APPD. - - - - - - DR. ANGLES: 42052 N/A DATE DATE DATE ------------------- DWG. SIZE B SHEET 3 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Connecting Rod Adjustment Procedure B Drive Bar C Hitch Pin Connecting Rod D Primary Link 1 "ON" Position ➊ Move disconnect handle to the "ON" position. ➋ If switch does not fully close, return handle to "OFF" position. ➌ Remove link spring hitch pin and disengage the connectiong rod from the primary link. ➍ Turn connecting rod counter-clockwise (1 or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring E 2 "OFF" Position ➊ Move disconnect handle to the "OFF" position. ➋ If switch does not fully open, return handle to "ON" position. ➌ Remove hitch pin and link spring, then disengage the connectiong rod from the primary link. ➍ Turn connecting rod clockwise (1 or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test. ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring F (4) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------CHKD. - - - - - - APPD. - - - - - - DR. ANGLES: 42052 N/A DATE DATE DATE ------------------- DWG. SIZE B SHEET 4 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Enclosure without Handle Cutout ● Enclosures with a Flange Thickness less than 3/16" use dimensions below to install disconnect handle. ● Enclosures with a Flange Thickness 3/16" and greater use dimensions in Alternate Mounting Kit 1494V-H6 to install disconnect handle. 1 Locate Handle B 1 - 1/8" Max. 1 - 1/8" Max. 1 - 3/8" Min. 1 - 3/8" Min. 14 - 3/8" Min. 14 - 3/8" Min. Top Handle Hole C Right Hand Flange D Left Hand Flange 2 Drill Handle Holes (2) .328 Dia. Holes Top Handle Hole 5/16" Square corners or up to 1/4" radius 5 - 1/2" 6 - 1/2" 1/2" 1/4" E F (5) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------------- DWG. SIZE B SHEET 5 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures) Door Catch Mounting Bracket: ● Provided with projections for welding. ● Projections can also be used as a guide for drilling holes. ● Can be used as a template to drill corresponding holes in the enclosure door. ● User to supply the hardware for fastening the bracket. ● Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. ● The bracket hardware must be inaccessible to unauthorized personnel. ● Dimension K (3/4" to 1") ● When using large disconnect handle kit only (1494F-M2 or -S2), use door catch provided with handle kit. ● When using large disconnect handle kit and small door hardware kits (1494V-L1, -LL1, -L2 or -LL2), use door catch B provided with door hardware kit. Dimension K (1-1/8" to 1-3/8") ● When using large disconnect handle kit only (1494F-M2 or -S2), use door catch (40492-080-02) which can be ordered from factory. ● When using large disconnect handle kit and large door hardware kits (1494V-L3 or -LL3), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top C 22 - 37 lb-in Door Catch TOP VIEW Flange Thickness Enclosure Door K Door Catch Mounting Bracket C Enclosure Base Door Catch B D D Enclosure Dimensions NEMA SIZE A (min) B (min) C (max) D E 400A 14 - 3/8" 1 - 3/8" 1 - 1/8" 1 - 5/8" 3 -3/4" C C B B A A E E E Top Handle Hole Door Catch Mounting Bracket Door Catch Mounting Bracket D D Right Hand Flange F Left Hand Flange (6) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 6 OF 13 42052-154 B-vertical.ai 1 A 2 3 4 5 6 7 8 Disconnect Switch Installation 1 Locate Disconnect Switch CC EE A A AA CC FF FF B BB BB DD DD Top Handle Hole HH HH GG GG C Right Hand Flange Left Hand Flange Panel Mounting Dimensions Switch Size 400A AA BB CC DD EE FF (4 Mounting Plate Holes) GG HH 5" 5-1/2" 2" 11" 5" 9/32" Dia. 4-3/4" 1-3/8" 2 Install Disconnect Switch 3 Assemble and Install Line Terminal Guard D LIN ET ER 1 AL GU AR D 2 90 - 130 lb-in LIN ET ER MIN AL E F MIN GU AR D (7) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 7 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Trailer Fuse Block Installation (Switch Rating 400A) Fuse Block Location 1 Trailer Note: Not required for non-fusible disconnect switch applications. 400 Amp Trailer Fuse Block (1494V-FS400) Fuse B Amps Voltage Class 200 200 200 200 400 400 400 400 250 600 600 600 250 600 600 600 H/R H/R J HRCII-C H/R H/R J HRCII-C A Torque (lb-in) Fuse Clip Fuse Lug to Wire Block Terminal into Lug 7-11/16" 10-3/16" 16-22 6-3/8" 6-3/8" 8-11/16" 11-11/16" 22-37 7-3/16" 8-11/16" 90-130 175-200 275-305 A C 4 - 3/4" 2 Install Trailer Fuse Block D E 90 - 130 lb-in F (8) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 8 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Phase Barrier Replacement Kit (Switch Rating 400A) 1494F-PH5 20 - 30 lb-in 3 B 1 4 2 C CLICK Terminal Adapter Installation - Conversion from Fusible to Non-Fusible (Switch Rating 400A) D 3 90 - 110 lb-in 175 - 200 lb-in 1 35 - 50 lb-in 2 E F (9) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 9 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Fuse Clip Installation (Switch Rating 400A) 1 1 Switch for Right Hand Mechanism 1 - 1/8" 200A Fuse Clips 400A Fuse Clips Switch for Left Hand Mechanism 200A Fuse Clips 400A Fuse Clips 16 - 22 lb-in 22 - 37 lb-in 16 - 22 lb-in 22 - 37 lb-in 2 2 B 1 1 C 2 Switch for Right Hand Mechanism 200A Fuse Clips 400A Fuse Clips D 2 Switch for Left Hand Mechanism 23 - 37 lb-in 40 - 55 lb-in 2 1 E 1 2 200A Fuse Clips 400A Fuse Clips F 23 - 37 lb-in 40 - 55 lb-in (10) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 10 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Bulletin 1494V Disconnect Switch Kit Disconnect Kit Catalog Number and Description Switch with Right Hand Mechanism 1494V-DS400 (400A) B Switch Switch with Left Hand Mechanism 1494V-DSX400 (400A) C Handle 1494F-M2 (7-1/2" Painted Metal) (400A / 600A) 1494F-S2 (7-1/2" Stainless Steel) (400A / 600A) 1494V-RB3 (Standard) (400A) Enclosure Working Depth: 9-1/2" to 10" Connecting Rod 1494V-RB4 (Extended)(400A) Enclosure Working Depth: 9-1/2" to 23" D Fuse Block E Fuse Clips F 1494V-FS400 (400A) 1401-N45 (Class H, J, 200A-250V, 200A-600V) 1401-N46 (Class H, J, 400A-250V, 400A-600V) 1401-N54 (Class R, 200A-250V, 200A-600V) 1401-N55 (Class R, 400A-250V, 400A-600V) (11) G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 11 OF 13 42052-154 B-vertical.ai 1 2 3 4 5 6 7 8 A Bulletin 1494V Disconnect Switch Optional Accessory List Optional Accessories (Installation Instructions Included with Accessory Kits) Catalog Number and Description Switch with Right Hand Mechanism 1495-N43 (1-N.O./N.C.) 1495-N44 (2-N.O./N.C.) Electrical Interlock B Switch with Left Hand Mechanism 1495-N41 (1-N.O./N.C.) 1495-N42 (2-N.O./N.C.) Auxiliary Contact 1495-N8 (1-N.O.) (400A) 1495-N9 (1-N.C.) (400A) Auxiliary Contact Adapter Kit 1495-N25 (400A) (Required only for Switch with Left Hand Mechanism) C 1494R-N14 (CU Wire Size 2 - #1/0 -250 MCM) (400A) Lug Connectors 1494R-N15 (CU Wire Size #4 . . 500 MCM) (400A) D Phase Barrier 1494F-PH5 (400A) Switch Rating Fuse Cover with Door E Fuse Class Fuse Clip Rating 250V 600V Cat No. 400A Non-Fusible ---- ---- 1495-N68➀ 400A Non-Fusible ---- ---- 1495-N63➁ 400A H, J, R 200A 400A 200A 400A 1495-N68➀ 400A H, J, R 200A 400A 200A 400A 1495-N63➁ ➀ Switch with right hand mechanism ➁ Switch with left hand mechanism F 42052-154-01 (2) Printed in U.S.A. G REFERENCE REVISION AUTHORIZATION 1 1023056 2 1030857 BULLETIN 1494V 400A VARIABLE DEPTH DISCONNECT SWITCH INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 12 OF 13 42052-154 B-vertical.ai ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Variable depth adjustment
- 400A Rating
- Right/Left-hand mechanisms
- Disconnect handle
- Spring bracket
- Defeater lever
Frequently asked questions
The variable depth adjustment enables installation in enclosures with different flange thicknesses, providing flexibility in design and installation.
The 1494V Variable Depth Disconnect Switch is rated for 400A.
The right-hand mechanism is operated by moving the handle to the right for the 'ON' position and left for the 'OFF' position. The left-hand mechanism works in reverse, with the handle moving left for 'ON' and right for 'OFF'.
Refer to the 'Quick Installation Guide,' page 2 of the manual, for step-by-step instructions on how to install the handle and bracket.
Yes, the switch can be used for both fusible and non-fusible applications. The optional accessory kit 1495-N25 allows for conversion from a fusible to a non-fusible configuration.