The Allen-Bradley 1494C Cable Operated Disconnect Switch Kit and Acessories (600A) is a powerful and reliable solution for controlling electrical circuits up to 600 amps. It features a cable-operated mechanism for remote control, and can be configured for right-hand or left-hand operation. The kit includes a disconnect switch, handle, cable mechanism, fuse block and fuse clips. It is designed for use in a variety of industrial applications and is known for its durability and ease of installation.
PDF
Download
Document
Advertisement
Advertisement
1 2 3 4 5 6 7 8 A Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ _ _ Series 2 : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator. B C D Table of Contents Page Quick Installation Guide - Disconnect Switch Installation - Disconnect Handle Installation - Cable Mechanism Installation - Connecting Rod Adjustment Procedure 2,3 3 4 5 Conversion from Right Hand to Left Hand Operation 6 Enclosure Without Handle Cutout - Locate Handle - Drill Handle Holes 7 Door Catch Mounting Bracket Installation 8 Trailer Fuse Block Installation (600A) 9 Fuse Clip Installation (600A) 10 Bulletin 1494C Cable Operated Disconnect Switch Kit Components 11 Bulletin 1494C Cable Operated Disconnect Switch Kit Optional Accessory List 12 E F 42052-190-01 (1) Printed in U.S.A. G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. G. Ushakow CHKD. M. Jutz APPD. J. Koziczkowski DR. ANGLES: 42052 N/A DATE 7-30-07 7-30-07 DATE 7-30-07 DATE DWG. SIZE B SHEET 1 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A QUICK INSTALLATION GUIDE IMPORTANT: When locating the 600A switch, verify that the minimum diameter for the loop of the cable between the switch mechanism and handle mechanism is not less than 16 inches. Any reduction to the diameter of the bend loop for the cable will reduce the efficiency of the cable system, and create additional drag and friction within the cable conduit. IMPORTANT: Verify that the cable assembly does not interfere with any mechanical and moving parts. Keep the cable conduit a minimum of 1/2" from all heat sources and current carrying terminals, fuses, transformers, etc. 1 Disconnect Switch Installation B 1a Locate switch with right hand mechanism 15" C 15" 8-1/4" 8-1/4" (4) - 9/32" Dia. Mounting Holes (4) - 9/32" Dia. Mounting Holes 16" Dia. Minimum 16" Dia. Minimum Enclosure with Right Hand Flange D Enclosure with Left Hand Flange 1b Locate switch with left hand mechanism 15" 15" E 8-1/4" 8-1/4" (4) - 9/32" Dia. Mounting Holes (4) - 9/32" Dia. Mounting Holes 16" Dia. Minimum 16" Dia. Minimum Enclosure with Right Hand Flange F Enclosure with Left Hand Flange (2) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 2 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A 1 Disconnect Switch Installation (Cont'd) 2 Rotate crossbar to closed position. 3 Assemble the cable mechanism bracket to the disconnect switch. B 90 - 130 lb-in C 4 5 Turn the connecting rod counter-clockwise (less than 1 turn) Turn the connecting rod clockwise (approximately 9 - 10 turns) until jam nuts touch drive bar until hole in threaded rod aligns with hole in cable mechanism lever. D Drive Bar Threaded Rod Jam Nuts E Cable Mechanism Lever F (3) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 3 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A 1 Disconnect Switch Installation (Cont'd) 6 7 Attach threaded rod to cable mechanism lever. Threaded Rod Assemble disconnect switch assembly to mounting plate. 90 - 130 lb-in 90 - 130 lb-in 90 - 130 lb-in 2 1 B Cable Mechanism Lever (4) - 5/16-18 thread forming screws provided with disconnect switch. C 2 Disconnect Handle Installation 1 2 Install gasket. 3 Install handle and mechanism bracket. Install defeater lever. (Right Hand Flange Mounted Shown) 60 - 80 lb-in 7-11 lb-in NOTE: Apply grease from capsule to gasket or groove to retain gasket to handle. D 3 Cable Mechanism Installation 1 Verify that disconnect switch and handle are in the "ON" position. 2 Rotate connecting rod (clockwise) into drive bar until it begins to exit the drive bar (approximately 18 full turns). E C L O S E D F (4) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 4 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A 3 Cable Mechanism Installation (Cont'd) 3 Align connecting rod with primary link. Connecting Rod 4 Install hitch pin clip Hitch Pin Clip Primary Link B 5 Turn disconnect handle "OFF" and install handle mechanism C spring. D 4 Connecting Rod Adjustment Procedure "OFF" Position "ON" Position ➊ Move disconnect handle to the "OFF" position. ➋ If switch does not fully open, return handle to "ON" position. ➌ Remove hitch pin and link spring, then disengage the connecting rod ➊ Move disconnect handle to the "ON" position. ➋ If switch does not fully close, return handle to "OFF" position. ➌ Remove link spring hitch pin and disengage the connecting rod E ➍ ➎ ➏ ➐ from the primary link. from the primary link. ➍ Turn connecting rod clockwise (1 or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and Turn connecting rod counter-clockwise (1 or more) full turns. Re-engage connecting rod in primary link of handle, insert hitch pin and re-test Repeat as necessary. Re-install link spring. ➏ ➐ ➊ ➎ re-test. Repeat as necessary. Re-install link spring. ➊ ➎ ATTENTION: CHECK FOR PROPER OPERATION. Upon completion of the installation instructions, no further adjustment of the cable mechanism is required. F (5) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 5 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Conversion from Right Hand to Left Hand Operation (If Required) IMPORTANT: Switch conversion to left-hand operation requires left-hand cable mechanism. B 1 Remove drive mechanism from right side of switch (3) - 5/16 - 18 Hex Head Screws with disconnect switch in the "OFF" position. C 2 Rotate crossbar to closed position. 3 Reinstall drive mechanism on left side of switch D ATTENTION: With switch in the "CLOSED" position, drive mechanism should align with crossbar. E 90 -130 lb-in F (6) G REFERENCE REVISION AUTHORIZATION 1 1029855 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 6 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Enclosure without Handle Cutout ● Enclosures with a Flange Thickness less than 3/16" use dimensions below to install disconnect handle. 1 Locate Handle B 1-1/8" 1-1/8" 1-3/8" 1-3/8" 18-3/16" 18-3/16" Top Handle Hole C Right Hand Flange Left Hand Flange 2 Drill Handle Holes D (2) .328 Dia. Holes 5/16" Top Handle Hole 1/2" 5-1/2" 6-1/2" 1/4" Square corners or up to 1/4" radius E F (7) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 7 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures) Door Catch Mounting Bracket: ● Provided with projections for welding. ● Projections can also be used as a guide for drilling holes. ● Can be used as a template to drill corresponding holes in the enclosure door. ● User to supply the hardware for fastening the bracket. ● Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. ● The bracket hardware must be inaccessible to unauthorized personnel. Dimension K (3/4" to 1") ● When using large disconnect handle kit only (1494F-M2 or -S2), use door catch provided with handle kit. B ● When using large disconnect handle kit and small door hardware kits (1494V-L1, -LL1, -L2 or -LL2), use door catch provided with door hardware kit. Dimension K (1-1/8" to 1-3/8") ● When using large disconnect handle kit and large door hardware kits (1494V-L3 or -LL3), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top C Door Catch TOP VIEW Flange Thickness Enclosure Door K Door Catch Mounting Bracket 1 - 1/8" Enclosure Base Door Catch 1 - 5/8" D 1 - 3/8" 1-1/8" 1-1/8" E 1-3/8" 1-3/8" 18-3/16" 18-3/16" 3-3/4" 3-3/4" Top Handle Hole Door Catch Mounting Bracket Door Catch Mounting Bracket 1-5/8" 1-5/8" F (8) Right Hand Flange Left Hand Flange G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 8 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Trailer Fuse Block Installation (Switch Rating 600A) Note: Not required for non-fusible disconnect switch applications. 2 Trailer Fuse Block Location 1 Trailer Fuse Block Location (400A Class H, J, R Fuses) (600A Class J Fuses) B C 8-1/4" 8-1/4" 6-3/4" A 6-3/4" A 3-3/16" 3" 3/8" 3/16" D 3-15/16" 3-15/16" Note: Terminal bolts need to be moved from disconnect switch load terminals to fuse block. 3" 2-13/16" 2-13/16" 3" 6-3/4" 6-3/4" 600 Amp Trailer Fuse Block (1494V-FS600) 400 Amp Trailer Fuse Block (1494V-FSV400) Fuse Amps Voltage Class 400 400 400 250 600 600 H/R H/R J A Fuse Clip Fuse Lug to Wire Block Terminal into Lug 22-37 90-130 175-200 275-305 E 1-3/4" 4-1/4" 1-1/8" Fuse Torque (lb-in) Amps Voltage Class 600 250 / 600 J A 4-3/8" Torque (lb-in) Fuse Bolt Fuse Lug to Wire Block Terminal into Lug 300-350 90-130 175-200 275-305 3 Trailer Fuse Block Location (600A - 250V / 600V Class H, R Fuses) Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 1491-N621 and 1491-R621). F (9) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 9 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Fuse Clip Installation (Switch Rating 600A) 400A Fuses (Class H, J, R) 600A Fuses (Class J) 300 - 350 lb-in 1 40 - 55 lb-in B 2 2 1 C 4 300 - 350 lb-in D 3 E 600A Fuses (Class H, R) Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 1491-N621 and 1491-R621). F (10) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 10 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Bulletin 1494C Cable Operated Disconnect Switch Kit Components Disconnect Switch Kit Cat No. Switch with Right Hand Mechanism 1494V-DS600 (600A) B Convertible in the field for Left Hand operation Switch Handle 1494F-M2 (7-1/2" Painted Metal) (400A / 600A) 1494F-S2 (7-1/2" Stainless Steel) (400A / 600A) C Cable Mechanism Cable with Right Hand Mechanism 1494C-CM13: 600A (4 Ft Cable) 1494C-CM14: 600A (5 Ft Cable) 1494C-CM15: 600A (6 Ft Cable) 1494C-CM16: 600A (10 Ft Cable) Cable with Left Hand Mechanism 1494C-CMX13: 600A (4 Ft Cable) 1494C-CMX14: 600A (5 Ft Cable) 1494C-CMX15: 600A (6 Ft Cable) 1494C-CMX16: 600A (10 Ft Cable) D Mounted with Switch 1494V-FSV400 (400A Class H, J, R) 1494V-FS600 (600A Class J) Fuse Block Separately Mounted 1491-N621 (600A 250V / 600V Class H) 1491-R621 (600A 250V / 600V Class R) 400A Fuses E 1401-N46 (Class H, J, 400A-250V, 400A-600V) 1401-N55 (Class R, 400A-250V, 400A-600V) Fuse Clips 600A Fuses Class J - Bolts directly to switch and fuse block (no clips required) Class H, R - Fuse clips included with separately mounted fuse blocks Cat. Nos.1491-N621 and 1491-R621 F (11) G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 11 OF 13 42052-190 B-vertical.ai 1 2 3 4 5 6 7 8 A Bulletin 1494C Cable Operated Disconnect Switch Kit Optional Accessory List Optional Accessories (Installation Instructions Included with Accessory Kits) Electrical Interlock B Catalog Number and Description Switch with Right Hand Mechanism 1495-N34 (1-N.O./N.C.) * 1495-N35 (2-N.O./N.C.) * *Requires Adapter Kit 1495-N36 Auxiliary Contact 595-A (1-N.O.) (600A) * 595-B (1-N.C.) (600A) * *Requires Adapter Kit 595-N1 Switch and Fuse Block 1494R-N10 (CU Wire (2) - #1/0 - 350 MCM) (600A or 400A Fuse Block) (3 per kit) C Lug Connectors 1494R-N11 (CU Wire (1) - #1/0 - 500 MCM) (600A or 400A Fuse Block) (3 per kit) Separately Mounted Fuse Blocks 1494R-N12 (CU Wire (2) - #1/0 - 350 MCM) (600A) (2 per kit) D Switch Rating Fuse Cover with Door E Available only for R.H. mounted disconnect switch. Fuse Class Fuse Clip Rating 250V 600V Cat No. 600A Non-Fusible ---- ---- 1495-N61 600A H, J, R 400A 400A 1495-N61 600A J 600A 600A 1495-N61 600A H,R 600A 600A N/A 42052-190-01 (1) F Printed in U.S.A. G REFERENCE REVISION AUTHORIZATION 1 1026760 BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION INSTRUCTION SHEET DIMENSIONS APPLY BEFORE SURFACE TREATMENT (DIMENSIONS IN INCHES) TOLERANCES UNLESS OTHERWISE SPECIFIED .XX: N/A .XXX: N/A E - DOC THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC. OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC. H LOCATION: MILWAUKEE, WISCONSIN U.S.A. ------------CHKD. ------------APPD. ------------DR. ANGLES: 42052 N/A DATE DATE DATE ------------------------------------- DWG. SIZE B SHEET 12 OF 13 42052-190 B-vertical.ai ">
Advertisement
Key Features
- 600A rating
- Cable Operated
- Right/Left Hand
- Fuse Block
- Optional Accessories
- Enclosure Mounts
- Remote Control
Frequently Answers and Questions
How do I convert the switch from right-hand operation to left-hand operation?
To convert the switch to left-hand operation, remove the drive mechanism from the right side of the switch while in the "OFF" position, then rotate the crossbar to the closed position. Reinstall the drive mechanism on the left side of the switch, ensuring alignment with the crossbar when the switch is closed. Tighten the screws to 90-130 lb-in.
What are the minimum dimensions required for the loop of cable between the switch mechanism and handle mechanism?
The minimum diameter for the loop of the cable should be at least 16 inches. Smaller diameters will reduce the efficiency of the cable system, causing more drag and friction within the conduit.
How do I adjust the connecting rod if the switch doesn't fully open or close?
To adjust the connecting rod, move the disconnect handle to the "OFF" position. If the switch doesn't fully open, return the handle to the "ON" position, remove the hitch pin and link spring, disengage the connecting rod from the primary link, turn the connecting rod clockwise (1 or more) full turns, re-engage the connecting rod, insert the hitch pin, re-test, reinstall the link spring and repeat if necessary. For adjustments when the switch doesn't close properly, follow the similar steps, but turn the connecting rod counter-clockwise.