Allen-Bradley Compact Combination Fast Analog I/O Module is a versatile input/output device designed for industrial applications. It offers a combination of both analog inputs and outputs, allowing you to monitor and control various processes, from temperature and pressure to flow rate and position. This module, when installed with other Compact I/O components or controllers, can be a valuable asset in your automation system.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions Compact Combination Fast Analog I/O Module Catalog Number 1769-IF4FXOF2F Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge 3 Remove Power 3 Hazardous Location 4 Environnements dangereux 4 About the 1769-IF4FXOF2F Module 5 Install the 1769-IF4FXOF2F Module 6 Replacement Parts 11 Field Wiring Connections 11 Specifications 23 Additional Resources 28 About This Publication Use this document as a guide when installing a Compact Combination Fast Analog I/O Control Module. Publication 1769-IN081A-EN-P - February 2007 2 Compact Combination Fast Analog I/O Module Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING IMPORTANT ATTENTION Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and recognize the consequences. SHOCK HAZARD Labels may be on or inside the equipment (for example, drive or motor) to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment (for example, drive or motor) to alert people that surfaces may reach dangerous temperatures. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 3 Electrostatic Discharge ATTENTION Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. Follow these guidelines when you handle the module: • Touch a grounded object to discharge static potential. • Wear an approved wrist-strap grounding device. • Do not touch the bus connector or connector pins. • Do not touch circuit components inside the module. • Use a static-safe work station, if available. • Keep the module in its static-shield box when not in use. Remove Power ATTENTION Remove power before removing or inserting this module. When you remove or insert a module with power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: • sending an erroneous signal to your system’s field devices, causing unintended machine motion. • causing an explosion in a hazardous environment. Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. Publication 1769-IN081A-EN-P - February 2007 4 Compact Combination Fast Analog I/O Module Hazardous Location This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. The following statement applies to use in hazardous locations. WARNING EXPLOSION HAZARD Substitution of components may impair suitability for Class I, Division 2. Do not replace components or disconnect equipment unless power is switched off or the area is known to be non-hazardous. Do not connect or disconnect components unless power is switched off or the area is known to be non-hazardous. This product must be installed in an enclosure. All wiring must comply with Class I, Division 2 wiring methods of Article 501 of the National Electrical Code and/or in accordance with Section 18-1J2 of the Canadian Electrical Code, and in accordance with the authority having jurisdiction. Environnements dangereux Cet équipement est conçu pour être utilisé dans des environnements de Classe 1, Division 2, Groupes A, B, C, D ou non dangereux. La mise en garde suivante s’applique à une utilisation dans des environnements dangereux. AVERTISSEMENT DANGER D’EXPLOSION La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement de Classe 1, Division 2. Ne pas remplacer de composants ou déconnecter l'équipement sans s'être assuré que l'alimentation est coupée et que l'environnement est classé non dangereux. Ne pas connecter ou déconnecter des composants sans s'être assuré que l'alimentation est coupée ou que l'environnement est classé non dangereux. Ce produit doit être installé dans une armoire. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 5 About the 1769-IF4FXOF2F Module Compact I/O is suitable for use in an industrial environment when installed in accordance with these instructions. Specifically, this equipment is intended for use in clean, dry environments (Pollution degree 2(1)) and to circuits not exceeding Over Voltage Category II(2) (IEC 60664-1)(3). Module Description 1 2a Item Description 3 OK Analog DANGER Do Not Remove RTB Under Power Unless Area is Non-Hazardous 10a 1 Bus lever (with locking function) 2a Upper panel mounting tab 2b Lower panel mounting tab 3 Module status LED 4 Module door with terminal identification label 5a Movable bus connector with female pins 5b Stationary bus connector with male pins 6 Nameplate label 7a Upper tongue-and-groove slots 7b Lower tongue-and-groove slots 8a Upper DIN rail latch 8b Lower DIN rail latch 9 Write-on label (user ID tag) 10 Removable terminal block (RTB) with finger-safe cover 10a RTB upper retaining screw 10b RTB lower retaining screw V in 0 + V in 1+ V/I in 1I in 1+ V/I in 0I in 0 + V in 2+ V in 3+ V/I in 2 - 10 V/I in 3- 10b V out 1+ I in 2+ I in 3 + ANLG Com ANLG Com V out 0+ I out 0+ I out 1+ Ensure Adjacent Bus Lever is Unlatched/Latched Before/After Removing/Inserting Module 4 1769-IF4FXOF2F 8a 7a 7a 2b OK Analog 5a 5b 9 6 7b 7b 8b (1) Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is expected. (2) Over Voltage Category II is the load level section of the electrical distribution system. At this level, transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insulation. (3) Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC) designations. Publication 1769-IN081A-EN-P - February 2007 6 Compact Combination Fast Analog I/O Module Simplified Input Circuit Diagram Simplified Output Circuit Diagram Install the 1769-IF4FXOF2F Module Attach the module to the controller or an adjacent I/O module before or after mounting. For mounting instructions, see Module to Panel Using the Dimensional Template, or Mount Module to a DIN Rail. To work with a system that is already mounted, see Replace a Single Module Within a System. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 7 The following procedure shows you how to assemble the Compact I/O system. 3 4 2 1 5 1 1. Disconnect power. 2. Check that the bus lever of the module to be installed is in the unlocked (fully right) position. 3. Use the upper and lower tongue-and-groove slots (1) to secure the modules together or to a controller. 4. Move the module back along the tongue-and-groove slots until the bus connectors (2) line up with each other. 5. Push the bus lever back slightly to clear the positioning tab (3). Use your fingers or a small screwdriver. 6. To allow communication between the controller and module, move the bus lever fully to the left (4) until it clicks, making sure it is locked firmly in place. ATTENTION When attaching I/O modules, it is very important that the bus connectors are securely locked together to be sure of proper electrical connection. Securely locking together the bus connectors is required for use in hazardous locations. For more information on hazardous locations see page 4. 7. Attach an end-cap terminator (5) to the last module in the system by using the tongue-and-groove slots as before. Publication 1769-IN081A-EN-P - February 2007 8 Compact Combination Fast Analog I/O Module 8. Lock the end-cap bus terminator (6). IMPORTANT You must use a 1769-ECR or 1769-ECL right or left end cap to terminate the end of the serial communication bus. An I/O configuration fault will occur if an end cap is not used. Replace a Single Module Within a System The module can be replaced while the system is mounted to a panel or DIN rail. 1. Remove power. Refer to Remove Power on page 3. 2. Remove the upper and lower mounting screws from the module or open the DIN latches using a flat-blade or Phillips screwdriver. 3. Move the bus lever to the right to disconnect or unlock the bus. 4. On the right-side adjacent module, move its bus lever to the right (unlock) to disconnect it from the module to be removed. 5. Gently slide the disconnected module forward. If you feel excessive resistance, check that the module is disconnected from the bus and that both mounting screws are removed or DIN latches opened. TIP It may be necessary to rock the module slightly from front to back to remove it, or, in a panel-mounted system, to loosen the screws of adjacent modules. 6. Be sure that the bus lever on the module and on the right-side adjacent module are in the unlocked (fully right) position before installing the replacement module. 7. Slide the replacement module into the open slot. 8. Connect the modules by locking (fully left) the bus levers on the replacement module and the right-side adjacent module. 9. Replace the mounting screws or snap the module onto the DIN rail. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 9 Mount Expansion I/O ATTENTION During panel or DIN rail mounting of all devices, be sure that all debris, that is, metal chips or wire strands, is kept from falling into the module. Debris that falls into the module could cause damage when cycling power. Minimum Spacing Maintain spacing from enclosure walls, wireways, or adjacent equipment. Allow 50 mm (2 in.) of space on all sides for adequate ventilation, as shown. End Cap Compact I/O Compact I/O Compact I/O Compact I/O Controller Side Compact I/O Top Side Bottom Mount Module to Panel Mount the module to a panel using two screws per module. Use M4 or #8 panhead screws. Mounting screws are required on every module. Publication 1769-IN081A-EN-P - February 2007 10 Compact Combination Fast Analog I/O Module Module to Panel Using the Dimensional Template Spacing for single-wide modules 35 mm (1.378 in.) Spacing for one-and-a-half wide modules 52.5 mm (2.067 in.) Refer to host controller documentation for this NOTE: Overall spacing tolerance ±0.44 mm (0.016 in.) Locate holes every 17.5 mm (0.689 in.) to allow for a mix of single-wide and one-and-a-half-wide modules (for example, the 1769-OA16 module). Mount Module to Panel Using Modules as a Template This procedure lets you use the assembled modules as a template for drilling holes in the panel. Refer to Module to Panel Using the Dimensional Template on page 10 if you have sophisticated panel mounting equipment. On a clean work surface, assemble no more than three modules. Due to module-mounting hole tolerance, it is important to follow this procedure. 1. Using the assembled modules as a template, carefully mark the center of all module-mounting holes on the panel. 2. Return the assembled modules to the clean work surface, including any previously mounted modules. 3. Drill and tap the mounting holes for the recommended M4 or #8 screws. 4. Place the modules back on the panel, and check for proper hole alignment. 5. Attach the modules to the panel using the mounting screws. TIP If mounting more modules, mount only the last one of this group and put the others aside. This reduces the remounting time during drilling and tapping of the next group. 6. Repeat steps 1 to 6 for any remaining modules. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 11 Mount Module to a DIN Rail The module can be mounted using these DIN rails: • 35 x 7.5 mm (EN 50 022 - 35 x 7.5) • 35 x 15 mm (EN 50 022 - 35 x 15) To mount the module on a DIN rail follow these steps. 1. Close the DIN rail latches. 2. Press the DIN rail mounting area of the module against the DIN rail. The latches will momentarily open and lock into place. Replacement Parts The 1769-IF4FXOF2F module has the following replacement parts: • Terminal block, catalog no. 1769-RTBN18 (1 per kit) • Door, catalog no. 1769-RD (2 per kit) Field Wiring Connections This section includes information on the following topics: • Module grounding • System wiring guidelines • Module wiring • Differential inputs wiring • Single-ended input sensor/transmitter types wiring • Mixed-input transmitter type wiring • Analog outputs wiring • Terminal labeling • Finger-safe terminal block wiring and removal • Wire size and terminal screw torque • Module configuration Ground the Module This product is intended to be mounted to a well-grounded mounting surface such as a metal panel. Additional grounding connections from the module’s mounting tabs or DIN rail, if used, are not required unless the mounting surface cannot be grounded. Refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1, for additional information. Publication 1769-IN081A-EN-P - February 2007 12 Compact Combination Fast Analog I/O Module System Wiring Guidelines Consider the following when wiring your system: • All module commons (ANLG COM) are connected in the analog module. • The analog common (ANLG COM) is not connected to earth ground inside the module. • Channels are not isolated from each other. • Use Belden 8761, or equivalent, shielded wire. • Under normal conditions, the drain wire and shield junction must be connected to earth ground via a panel or DIN rail mounting screw at the analog I/O module end. Keep the shield connection to ground as short as possible.(1) • To ensure optimum accuracy, limit overall cable impedance by keeping your cable as short as possible. Locate the I/O system as close to your sensors or actuators as your application will permit.(2) • If multiple power supplies are used with analog inputs, the power supply commons must be connected. • The 1769-IF4FXOF2F module does not provide loop power for analog inputs. Use a power supply that matches the input transmitter specifications. • Differential analog inputs are more immune to noise than single-ended analog inputs. • Voltage outputs (Vout 0+ and Vout 1+) of the 1769-IF4FXOF2F module are referenced to ANLG COM. Load resistance for a voltage output channel must be equal to or greater than 1K Ω. • Current outputs (Iout 0+ and Iout 1+) of the 1769-IF4FXOF2F module source current that returns to ANLG COM. Load resistance for a current output channel must remain between 0 and 500 Ω. • Voltages on Vin+, V/Iin-, and Iin+ of the 1769-IF4FXOF2F module must be within +/-10V dc of analog common. ATTENTION Be careful when stripping wires. Wire fragments that fall into a module could cause damage at power up. Once wiring is complete, ensure the module is free of all metal fragments. (1) In environments where high-frequency noise may be present, it may be necessary to directly ground cable shields to earth at the module end and via a 0.1µF capacitor at the sensor end. (2) Cable length over 50 meters may impact accuracy. For details, refer to the Compact Combination Analog I/O Module, publication 1769-UM008A-EN-P. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 13 Wire Differential Inputs Belden 8761 Cable (or equivalent) + V in 0+ V in 1+ V/I in 0V/I in 1 - – I in 1+ I in 0+ V in 3+ Earth Ground the V in 2 + Shield Locally at the V/I in 2Module V/I in 3 - Differential Voltage Transmitter(1) I in 2+ I in 3+ ANLG Com ANLG Com V out 0+ V out 1+ I out 0+ I out 1+ Differential Current Transmitter(1) + – Earth Ground the Shield Locally at the Module (1) The sensor power supply must be rated Class 2. Wire Single-ended Input Sensor/Transmitter Types Sensor/ Transmitter Power Supply(1) 1769-IF4FXOF2F Terminal Block + - Current Transmitter + Signal V in 0+ I in 0+ V/I in 0 V in 1+ I in 1+ V/I in 1- Voltage Transmitter V in 2+ + I in 2+ Ground Signal V/I in 2V in 3+ I in 3+ V/I in 3ANLG Com ANLG Com V out 0+ (1) The sensor power supply must be rated Class 2. I out 0+ V out 1+ I out 1 + Publication 1769-IN081A-EN-P - February 2007 14 Compact Combination Fast Analog I/O Module Wire Mixed-input Transmitter Types Signal Single-ended Voltage Transmitter – V in 0+ I in 0+ + V/I in 0 V in 1+ I in 1+ + Differential Voltage Transmitter Signal – – Supply + + Differential Current Transmitter Signal – V/I in 1V in 2+ I in 2+ V/I in 2V in 3+ I in 3+ V/I in 3ANLG Com ANLG Com V out 0+ – Supply + 2-wire Current Transmitter 1769-IF4FXOF2F Terminal Block Signal + I out 0+ V out 1+ I out 1 + Sensor/ + Transmitter (1) Power Supply – (1) The sensor power supply must be rated Class 2. IMPORTANT When wiring analog inputs from current transmitters, a jumper must be placed between the input channel's VIN+ and IIN+ terminals. Measurement accuracy of current input signals will be impacted if the jumper is not used. TIP Any analog input channel that is not wired to a voltage or current source should not be enabled in the module configuration file. Enabling unused analog inputs can result in non-zero values being displayed in the module input data file. Either disable all unused analog inputs or place a jumper wire between the VIN+ and V/IIN- terminals for those channels. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 15 Wire Analog Outputs 1769-IF4FXOF2F Terminal Block V in 0+ I in 0+ V/I in 0 V in 1+ I in 1+ V/I in 1V in 2+ I in 2+ V/I in 2V in 3+ I in 3+ Voltage Load V/I in 3- Earth Ground ANLG Com ANLG Com V out 0+ I out 0+ V out 1+ Current Load I out 1 + Earth Ground ATTENTION Analog outputs may fluctuate for less than a second when power is applied or removed. This characteristic is common to most analog outputs. While the majority of loads will not recognize this short signal, take preventive measures to ensure that connected equipment is not affected. Failure to take these preventative measures may result in unexpected load reactions. Label the Terminals A removable, write-on label is provided with the module. Remove the label from the door, mark the identification of each terminal with permanent ink, and slide the label back into the door. Your markings (ID tag) will be visible when the module door is closed. Remove the Finger-safe Terminal Block When wiring field devices to the module, it is not necessary to remove the terminal block. If you remove the terminal block, use the write-on label on the side of the terminal block to identify the module slot location and type. SLOT # _____ MODULE TYPE ______ Publication 1769-IN081A-EN-P - February 2007 16 Compact Combination Fast Analog I/O Module To remove the terminal block, loosen the upper and lower retaining screws. The terminal block will back away from the module as you remove the screws. When replacing the terminal block, torque the retaining screws to 0.46 Nm (4.1 in-lbs). Upper Retaining Screw Wiring the Finger-safe Terminal Block Lower Retaining Screw Wire the Finger-safe Terminal Block When wiring the terminal block, keep the finger-safe cover in place. 1. Loosen the terminal screws to be wired. 2. Route the wire under the terminal pressure plate. You can use the bare wire or a spade lug. The terminals will accept a 6.35 mm (0.25 in.) spade lug. TIP The terminal screws are non-captive. Therefore, it is possible to use a ring lug [maximum 1/4 inch o.d. with a 0.139 inch minimum i.d. (M3.5)] with the module. 3. Tighten the terminal screw making sure the pressure plate secures the wire. Recommended torque when tightening terminal screws is 0.68 Nm (6 in-lbs). TIP If you need to remove the finger-safe cover, insert a screw driver into one of the square wiring holes and gently pry the cover off. If you wire the terminal block with the finger-safe cover removed, you will not be able to put it back on the terminal block because the wires will be in the way. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 17 Wire Size and Terminal Screw Torque Each terminal accepts two wires with the following restrictions:. Wire Type Wire Size Terminal Screw Torque Retaining Screw Torque Solid Cu-90°C (194°F) #14…#22 AWG 0.68 Nm (6 in-lbs) 0.46 Nm (4.1 in-lbs) Stranded Cu-90°C (194°F) #16…#22 AWG 0.68 Nm (6 in-lbs) 0.46 Nm (4.1 in-lbs) Configure the 1769-IF4FXOF2F Module The following I/O memory mapping lets you configure the 1769-IF4FXOF2F module. Output Data File For each module, slot x, words 0 and 1 in the output data file contain the control program’s directed state of the module’s analog output channels. Word 2 contains the cancel input channel alarm control bits. Word 3 contains the cancel output channel clamp control bits. Word/Bit 15 14 13 12 11 10 09 08 07 06 05 04 03 02 Word 0 SGN Word 1 SGN 0 0 Word 2 0 0 0 0 0 0 0 0 CL I3 CH I3 CL I2 CH I2 CL I1 CH I1 CL I0 CH I0 Word 3 0 0 0 0 0 0 0 0 0 0 0 0 CL O1 CH O1 CL O0 CH O0 Analog Output Data Channel 0 Analog Output Data Channel 1 01 00 0 0 The bits are defined as follows: • SGN = Sign bit in 2’s complement format. • CHIx = Cancel High Process Alarm Latch for Input x: Allows each input high-process-alarm latch to be individually cancelled. NOTE: Cancel = 1. • CLIx = Cancel Low Process Alarm Latch for Input x: Allows each input low-process-alarm latch to be individually cancelled. NOTE: Cancel = 1. • CHOx = Cancel High Clamp Alarm Latch for Output x: Allows each output high-clamp-alarm latch to be individually cancelled. NOTE: Cancel = 1. • CLOx = Cancel Low Clamp Alarm Latch for Output x: Allows each output low-clamp-alarm-latch to be individually cancelled. NOTE: Cancel = 1. Publication 1769-IN081A-EN-P - February 2007 18 Compact Combination Fast Analog I/O Module Input Data File For each module, slot x, words 0…3 in the input data file contain the converted value of the module’s analog input channels. Word 4 in the input data file contains the time stamp value corresponding to the module's last input data sampling period. Words 5 and 6 in the input data file contain status bits for the analog input channels. Word 7 in the input data file contains status bits for the analog output channels. Words 8 to 9 contain the directed values of the analog output channels (output data echo). Word/Bit 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 Word 0 SGN Analog Read (Input) Data Value Channel 0 0 Word 1 SGN Analog Read (Input) Data Value Channel 1 0 Word 2 SGN Analog Read (Input) Data Value Channel 2 0 Word 3 SGN Analog Read (Input) Data Value Channel 3 0 Word 4 0 Time Stamp Value Word 5 Nu Nu Nu Nu Nu Nu Nu Nu Nu Nu Nu Nu SI3 SI2 SI1 SI0 Word 6 LI3 HI3 UI3 OI3 LI2 HI2 UI2 OI2 LI1 HI1 UI1 OI1 LI0 HI0 UI0 OI0 Word 7 Nu Nu UO1 OO1 Nu Nu UO0 OO0 Nu Nu Nu Nu Nu Nu SO1 SO0 Word 8 SGN Output Data Loopback/Echo Channel 0 0 0 Word 9 SGN Output Data Loopback/Echo Channel 1 0 0 The bits are defined as follows: • SGN = Sign bit in 2’s complement format. • Nu = Not Used. Bit set to 0. • SIx = General Status bit for input channels 0…3. • OIx = Over range flag bits for input channels 0…3. • UIx = Under range flag bits for input channels 0…3. • HIx = High Alarm flag bits for input channels 0…3. • LIx = Low Alarm flag bits for input channels 0…3. • SOx = General Status bit for output channels 0…1. • OOx = Over range flag bits for output channels 0…1. • UOx = Under range flag bits for output channels 0…1. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 19 Configuration Data File The manipulation of bits from this file is normally done with programming software (for example, RSLogix 500 software or RSNetWorx for DeviceNet software) during initial configuration of the system. In that case, graphical screens provided by the programming software simplify configuration. Some systems, like the 1769-ADN DeviceNet adapter system, also allow the bits to be altered as part of the control program using communication rungs. In that case, it is necessary to understand the bit arrangement. Word/Bit 15 Word 0 0 Real Time Sample Value Word 1 ETS Reserved Word 2 EC Word 3 14 13 12 Reserved Reserved 11 10 EA 09 AL 08 07 06 05 04 03 02 01 00 EI Reserved Input Filter Sel ChI0 Input Dta Fm ChI0 Reserved Inpt Tp/Rnge Sel ChI0 Word 4 SGN Process Alarm High Data Value Channel 0 0 Word 5 SGN Process Alarm Low Data Value Channel 0 0 Word 6 SGN Alarm Dead Band Value Channel 0 0 Word 7 Word 8 Reserved EC Word 9 Reserved Reserved EA AL EI Reserved Input Filter Sel ChI1 Input Dta Fm ChI1 Reserved Inpt Tp/Rnge Sel ChI1 Word 10 SGN Process Alarm High Data Value Channel 1 0 Word 11 SGN Process Alarm Low Data Value Channel 1 0 Word 12 SGN Alarm Dead Band Value Channel 1 0 Word 13 Word 14 Reserved EC Word 15 Reserved Reserved EA AL EI Reserved Input Filter Sel ChI2 Input Dta Fm ChI2 Reserved Inpt Tp/Rnge Sel ChI2 Word 16 SGN Process Alarm High Data Value Channel 2 0 Word 17 SGN Process Alarm Low Data Value Channel 2 0 Word 18 SGN Alarm Dead Band Value Channel 2 0 Word 19 Word 20 Word 21 Reserved EC Reserved Reserved EA AL EI Reserved Input Filter Sel ChI3 Input Dta Fm ChI3 Reserved Inpt Tp/Rnge Sel ChI3 Publication 1769-IN081A-EN-P - February 2007 20 Compact Combination Fast Analog I/O Module Word 22 SGN Process Alarm High Data Value Channel 3 0 Word 23 SGN Process Alarm Low Data Value Channel 3 0 Word 24 SGN Alarm Dead Band Value Channel 3 0 Word 25 Word 26 Reserved EC Word 27 Reserved Reserved EHI Outpt Fm ChI0 ELI LC ER Reserved FM PM 0 PFE Outpt Tp/Rnge Sel ChI0 Word 28 SGN Fault Value Channel 0 0 0 Word 29 SGN Program (Idle) Value Channel 0 0 0 Word 30 SGN Clamp High Data Value Channel 0 0 0 Word 31 SGN Clamp Low Data Value Channel 0 0 0 Word 32 SGN Ramp Rate Channel 0 0 0 0 PFE Word 33 Word 34 Reserved EC Word 35 Word 36 Reserved Reserved SGN EHI Outpt Fm ChI1 ELI LC Reserved Fault Value Channel 1 ER FM PM Outpt Tp/Rnge Sel ChI1 0 0 Word 37 SGN Program (Idle) Value Channel 1 0 0 Word 38 SGN Clamp High Data Value Channel 1 0 0 Word 39 SGN Clamp Low Data Value Channel 1 0 0 Word 40 SGN Ramp Rate Channel 1 0 0 Word 41 Reserved The bits are defined as follows: • SGN = Sign bit in 2’s complement format. • Real Time Sample Value = Provides the ability to configure the Real Time Sample Rate. • ETS = Enable Time Stamping. • EC = Enable Channel. • EA = Enable Alarm. • AL = Alarm Latch. • EI = Enable Input Process Alarm Interrupt. • Input Filter Sel ChIx = Input Channel Filter Setting. • Inpt Dta Fm ChIx = Input Data Format Select. • Inpt Tp/Rnge Sel ChIx = Input Type/Range Select. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module 21 • Process Alarm High Data Value Channel x = Provides the ability to configure the Input Process Alarm High Value. • Process Alarm Low Data Value Channel x = Provides the ability to configure the Input Process Alarm Low Value. • Alarm Dead Band Value Channel x = Provides the ability to configure the Input Process Dead Band Value. • Reserved = Bits not used, must be set to 0. • EHI = Enable Output Channel Interrupt on High Clamp Alarm. • ELI = Enable Output Channel Interrupt on Low Clamp Alarm. • LC = Latch Low/High Clamp and Under/Over Range Alarm. • ER = Enable Ramping. • FM = Enable Fault Alternate Output State mode. • PM = Enable Program/Idle Alternate Output State mode. • PFE = Enable Program/Idle to Fault Alternate Output State mode. • Outpt Fm ChIx = Output Data Format Select. • Outpt Tp/Rnge Sel ChIx = Output Type/Range Select. • Ramp Rate Channel x = Provides the ability to configure the Ramp Rate. Define Input Filter Selection / -3 dB Frequency To Select Make these bit settings 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 60 Hz 0 0 0 0 50 Hz 0 0 0 1 5 Hz 0 0 1 0 10 Hz 0 0 1 1 100 Hz 0 1 0 0 250 Hz 0 1 0 1 500 Hz 0 1 1 0 1000 Hz 0 1 1 1 No Filter 1 0 0 0 Publication 1769-IN081A-EN-P - February 2007 22 Compact Combination Fast Analog I/O Module Define To Select Make these bit settings 15 Input Type / Range Select Input Data Format Select 14 13 12 11 10 09 08 03 02 01 00 -10 to +10V dc 0 0 0 0 0 to 5V dc 0 0 0 1 0 to 10V dc 0 0 1 0 4 to 20 mA 0 0 1 1 1 to 5V dc 0 1 0 0 0 to 20 mA 0 1 0 1 Raw/ Proportional Counts 0 0 0 Engineering Units 0 0 1 Scaled for PID 0 1 0 Percent Range 0 1 1 10 09 08 07 06 05 04 Define To Select Make these bit settings 03 02 01 00 Output Type / Range Select -10 to +10V dc 0 0 0 0 0 to 5V dc 0 0 0 1 0 to 10V dc 0 0 1 0 4 to 20 mA 0 0 1 1 1 to 5V dc 0 1 0 0 0 1 0 1 15 14 13 12 11 0 to 20 mA Output Data Format Select Raw/ Proportional Counts 0 0 0 Engineering Units 0 0 1 Scaled for PID 0 1 0 Percent Range 0 1 1 Publication 1769-IN081A-EN-P - February 2007 07 06 05 04 Compact Combination Fast Analog I/O Module 23 Specifications Compact Combination Fast Analog I/O Module - 1769-IF4FXOF2F Attribute Value Dimensions (HxWxD), Approx. 118 mm (height) x 87 mm (depth) x 35 mm (width) Height including mounting tabs is 138 mm (5.43 in.) 4.65 in. (height) x 3.43 in (depth) x 1.38 in (width) Height including mounting tabs is 138 mm (5.43 in.) Approximate Shipping Weight (with carton) 290 g (0.64 lbs.) Storage Temperature -40 °C to +85 °C (-40 °F to +185 °F) Operating Temperature 0 °C to +60 °C (32 °F to +140 °F) Operating Humidity 5% to 95% non-condensing Operating Altitude 2000 m (6561 ft) Vibration Operating: 10 to 500 Hz, 5 G, 0.030 in. peak-to-peak Shock Operating: 30 G, 11 ms panel mounted (20G, 11 ms DIN rail mounted) Non-Operating: 40G panel mounted (30G DIN rail mounted) Bus Current Draw, max. 220 mA at 5V dc 120 mA at 24V dc(1) Heat Dissipation 3.39 Total Watts (The Watts per point plus the minimum Watts with all points energized.) Module OK LED On: module has power, has passed internal diagnostics, and is communicating over the bus. System Power Supply Distance Rating The module may not be more than 8 modules away from the system power supply. Recommended Cable Belden™ 8761 (shielded) Vendor I.D. Code 1 Product Type Code 10 Product Code 43 Off: Any of the above is not true. Input Words 10 Output Words 4 Configuration Words 42 (1) If the optional 24V dc Class 2 power supply is used, the 24V dc current draw from the bus is 0 mA. Publication 1769-IN081A-EN-P - February 2007 24 Compact Combination Fast Analog I/O Module Certifications Certification Value • C-UL certified (under CSA C22.2 No. 142) Agency Certification • UL 508 listed • CE compliant for all applicable directives Hazardous Environment Class Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) Radiated and Conducted Emissions EN50081-2 Class A Electrical /EMC: The module has passed testing at the following levels: (1) • ESD Immunity (IEC1000-4-2) • 4 kV contact, 8 kV air, 4 kV indirect • Radiated Immunity (IEC1000-4-3) • 10 V/m, 80…1000 MHz, 80% amplitude modulation, +900 MHz keyed carrier • Fast Transient Burst (IEC1000-4-4) • 2 kV, 5 kHz • Surge Immunity (IEC1000-4-5) • 1 kV galvanic gun • Conducted Immunity (IEC1000-4-6) • 10V dc, 0.15…80 MHz(1) Conducted Immunity frequency range may be 150 kHz…30 MHz if the Radiated Immunity frequency range is 30 MHz…1000 MHz. Output Specifications Attribute Value Analog Normal Operating Ranges 0…20 mA, 4…20 mA, +/-10V dc, 0…10V dc, 0…5 V dc, 1…5V dc Full Scale Analog Ranges(1) 0…21 mA, 3.2…21 mA, +/-10.5V dc, -0.5…10.5V dc, -0.5… 5.25V dc, 0.5… 5.25V dc (1) Number of Outputs Two single-ended Digital Resolution Across Full Range 13 bits unipolar, 13 bits plus sign bipolar Conversion Rate (all channels) max. 1 ms Step Response to 63% 2.0 ms Resistive Load Current: 0…500 Ω (includes wire resistance) Voltage: 1 KΩ or greater (2) Max. Inductive Load 0.1 mH (current loads), 1.0 uF (voltage loads) Field Calibration None required Overall Accuracy(3) 0.2% full scale at 25 °C (1) The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module will continue to convert the analog input up to the maximum full scale range. The flag automatically resets when within the normal operating range unless configured to latch. (2) Step response is the period of time between when the D/A converter was instructed to go from minimum to full range until the device is at 63% of full range. (3) Includes offset, gain, drift, non-linearity and repeatability error terms. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module Attribute Value Accuracy Drift with Temperature Current load: ±0.0058% FS per °C Voltage load: +/-0.0086% FS per °C Output Ripple(1) range 0 to 50 kHz (referred to output range) ±0.05% Non-linearity (in percent full scale) ±0.05% Repeatability(2) (in percent full scale) ±0.05% Output Error Over Full Temperature Range (0 to 60°C [+32 to +140°F]) Current: +/-0.4% of full scale Voltage: +/-0.3% of full scale Open and Short-Circuit Protection Yes Maximum Short-Circuit Current 50 mA Output Overvoltage Protection Yes Rated Working Voltage 30V ac/30V dc Output Group to Bus Isolation 500V ac or 710V dc for 1 minute (qualification test) 30V ac/30V dc working voltage (IEC Class 2 reinforced insulation) Channel Diagnostics High or Low Clamps Limit Exceeded, by status bit reporting 25 (1) Output ripple is the amount a fixed output varies with time, assuming a constant load and temperature. (2) Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to it consecutively, under the same conditions and in the same direction. Publication 1769-IN081A-EN-P - February 2007 26 Compact Combination Fast Analog I/O Module Input Specifications Attribute Value Analog Normal Operating Voltage: ± 10V dc, 0 to 10V dc, 0 to 5V dc, 1 to 5V dc Current: 0 to 20 mA, 4 to 20 mA Ranges(1) Full Scale Analog Ranges(1) Voltage: ± 10.5V dc, -0.5 to 10.5V dc, -0.5 to 5.25V dc, 0.5 to 5.25V dc Current: 0 to 21 mA, 3.2 to 21 mA Number of Inputs Four differential or single-ended Converter Type Successive Approximation Response Speed per Channel Input filter and configuration dependent. See your user’s manual. Resolution (max.) 14 bits (unipolar) 14 bits plus sign (bipolar) Rated Working Voltage(3) 30V ac/30V dc (2) Common Mode Voltage Range(4) ±10V dc maximum per channel Common Mode Rejection greater than 70 dB at 50 and 60 Hz with the 10 Hz filter selected, respectively. Input Impedance Voltage Terminal: 220K Ω (typical) Current Terminal: 250 Ω Overall Accuracy(5) Voltage Terminal: 0.15% full scale at 25 °C Current Terminal: 0.2% full scale at 25 °C (1) The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module will continue to convert the analog input up to the maximum full scale range. The flag automatically resets when within the normal operating range. (2) Resolution is dependent upon your filter selection. (3) Rated working voltage is the maximum continuous voltage that can be applied at the input terminal, including the input signal and the value that floats above ground potential (for example, 10V dc input signal and 20V dc potential above ground). (4) For proper operation, both the plus and minus input terminals must be within ±10V dc of analog common. (5) Includes offset, gain, non-linearity and repeatability error terms. Publication 1769-IN081A-EN-P - February 2007 Compact Combination Fast Analog I/O Module Attribute 27 Value Accuracy Drift with Temperature Voltage Terminal: ±0.003% per °C Current Terminal: ±0.0045% per °C Calibration None required Non-linearity (in percent full scale) ±0.03% Repeatability(1) ±0.03% Module Error over Full Voltage: 0.2% Temperature Range (0 to +60 °C [+32 °F to +140 °F]) Current: 0.3% Channel Diagnostics Over- or under-range by bit reporting, process alarms Maximum Overload at Input Voltage Terminal: ±30V dc continuous, 0.1 mA Current Terminal: ±32 mA continuous, ±7.6 V dc Terminals(2) Input Group to Bus Isolation 500V ac or 710V dc for 1 minute (qualification test) 30V ac/30V dc working voltage (IEC Class 2 reinforced insulation) (1) Repeatability is the ability of the input module to register the same reading in successive measurements for the same input signal. (2) Damage may occur to the input circuit if this value is exceeded. Publication 1769-IN081A-EN-P - February 2007 Additional Resources For more information refer to the following publications. Resource Description 1768 CompactLogix Controllers User Manual, publication number 1768-UM001 Detailed description of how to install and use your 1768 CompactLogix controller. MicroLogix 1200 and MicroLogix 1500 Programmable Controllers User Manual, publication number 1764-RM001 Detailed description of how to install and use your Compact I/O with MicroLogix 1200/1500 programmable controllers 1769-ADN DeviceNet Adapter User Manual, publication number 1769-UM001 Detailed description of how to install and use your Compact I/O system with the 1769-ADN DeviceNet adapter CompactLogix System User Manual, publication number 1769-UM007 Detailed description of how to install and use your Compact I/O system with the CompactLogix system Industrial Automation Wiring and Grounding Guidelines, publication number, publication number 1770-4.1 More information on proper wiring and grounding techniques You can view or download publications at http://literature.rockwellautomation.com. To order paper copies of technical documentation, contact your local Rockwell Automation distributor or sales representative. Compact, TechConnect, CompactLogix, MicroLogix, RSLogix 500, and RSNetWorx for DeviceNet are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1769-IN081A-EN-P - February 2007 PN 40071-222-01(1) Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. ´H'¶1-222-01(1)7¨ ">
Advertisement
Key features
- Fast Analog I/O
- Compact design
- Combination inputs & outputs
- Field wiring connections
- Module configuration
- Process alarm capabilities
- Output data echo
- DIN rail mounting
- Finger-safe terminal block
- Replacement parts
Frequently asked questions
When wiring analog inputs from current transmitters, a jumper must be placed between the input channel's VIN+ and IIN+ terminals. Refer to the 'Wire Mixed-input Transmitter Types' section in the viewed document for detailed instructions.
The viewed document does not specify a maximum number of modules. Consult the host controller documentation for details on system limitations.
The module can be configured for various input types and ranges using the 'Input Type/Range Select' bits in the Configuration Data File. Refer to the 'Configure the 1769-IF4FXOF2F Module' section in the viewed document.