1
2
A
3
4
5
6
7
8
Electrically Held Lighting Contactor Power Pole
(Cat 500LG-1PCK; -2PCK)
ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Install in a
suitable enclosure. Keep free from contaminants.
Kit
Catalog Number
Description
500LG-1PCK
Single Power Pole
500LG-2PCK
Double Power Pole
Power Pole
B
Wire Specifications
IMPORTANT: Use copper wire only.
Wire Type and Sizes for Power Pole Terminals with 1 and 2 Wires per Terminal
#8 AWG
Size
Type
#8 AWG
Stranded
Stranded
Solid
Stranded
Solid
Stranded
Solid
#10 AWG
C
#12 AWG
#14 AWG
#12 AWG
#10 AWG
#14 AWG
Stranded
Stranded
Solid
Stranded
Solid
Stranded
Solid
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Max. Torque
Temperature
(lb-in)
35
75˚C
Power Pole Removal
D
2
1
500
LG
500
E
LG
F
G
REFERENCE
REVISION
AUTHORIZATION
1
1020705
BULLETIN 500LG ELECTRICALLY HELD
LIGHTING CONTACTOR - POWER POLE
INSTRUCTION SHEET
DIMENSIONS APPLY BEFORE
SURFACE TREATMENT
(DIMENSIONS IN INCHES)
TOLERANCES UNLESS
OTHERWISE SPECIFIED
.XX:
N/A
.XXX:
N/A
E - DOC
THIS DRAWING IS THE PROPERTY OF
ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,
USED OR DISCLOSED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
H
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
G. Ushakow
CHKD. M. Jutz
APPD. A. Collins
DR.
ANGLES:
42052
N/A
DATE
DATE
DATE
5-26-06
5-26-06
5-26-06
DWG.
SIZE
B
SHEET
1
OF
2
42052-161
B-vertical.ai
1
2
3
4
5
6
7
8
A
N.C. Power Pole Installation
N.O. Power Pole Installation
2
2
0.43 in Max.
(11 mm Max.)
B
1
CLICK
500
LG
LG
500
CLICK
1
C
IMPORTANT: A maximum of 12 poles may be installed on the base. Positions "1" thru "4" on the base can be configured as either
normally open "N.O." or normally closed "N.C.", while positions "5" and "6" can be configured as "N.O." only.
D
Position "1"
Position "2"
Position "3"
Position "4"
Position "5"
Position "6"
E
500LG
F
42052-161-01 (1)
Printed in U.S.A.
-01
1
G
PART CHG.
NO. CHAR.
TWO SIDES PRINTED
BODY STOCK WHITE
BODY INK BLACK
MATERIAL
1
1020705
(DIMENSIONS IN INCHES)
TOLERANCES UNLESS
OTHERWISE SPECIFIED
N/A
.XXX:
N/A
FLAT
FOLDED
BULLETIN 500LG ELECTRICALLY HELD
LIGHTING CONTACTOR - POWER POLE
INSTRUCTION SHEET
DIMENSIONS APPLY BEFORE
SURFACE TREATMENT
.XX:
2-1/8" W x 2-3/4" H
SIZE
REFERENCE
REVISION
AUTHORIZATION
8-1/2" W x 11" H
E - DOC
THIS DRAWING IS THE PROPERTY OF
ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,
USED OR DISCLOSED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
H
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
------CHKD. - - - - - - APPD. - - - - - - DR.
ANGLES:
42052
N/A
DATE
DATE
DATE
-------------------
DWG.
SIZE
B
SHEET
2
OF
2
42052-161