Installation Instructions ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B (Cat. No. 1792D-8BV0D) 42761 This ArmorBlock MaXum I/O module (Cat. No. 1792D-8BV0D) is a stand-alone 24V dc I/O product which communicates via a DeviceNet network. The sealed housing of this module requires no enclosure. This model has 8 inputs. Inputs are 24V dc automatically configured for PNP (sourcing) or NPN (sinking) devices. Diagnostic features are short circuit and open wire detection reported to the point level. Local logic control has been added to this Series B product. The 1792D-8BVT0D also has 8 inputs but only 4 connectors. This new module gives you complete single point diagnostics. 1 Publication 1792D-IN051A-EN-P - February 2001 2 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Package Contents Your package contains: • 1 ArmorBlock MaXum Module • Installation Instructions (Note: Cable bases are ordered and shipped separately.) European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: • EN 50081-2 EMC - Generic Emission Standard, Part 2 Industrial Environment • EN 50082-2 EMC - Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: • Industrial Automation Wiring and Grounding Guidelines Application Data, publication 1770-4.1 • Automation Systems Catalog, publication B113 Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B 3 Install Your ArmorBlock MaXum I/O Module To install module: • Set the node address • Mount the module to the cable base • Connect the cord sets • Communicate with the module Set the Node Address Valid node addresses are 00 to 63. Set the node address using the rotary switches, RSNetWorx for DeviceNet, DeviceNetManager, or other software configuration tool. Setting the switches between 64 to 99 lets the software have address control. Each module is shipped set for node address 63. The switches are located on the underside of the module. The two switches are: • MSD (most significant digit) • LSD (least significant digit) To reset the node address, use a small blade screwdriver to rotate the switches. Line up the small black dot on the switch with the number setting you wish to use. The rotary switches are read at module power up only. Settings between 64 and 99 cause the module to use the last valid node address stored internally. Example: The last setting was 40. If a change is made to 68, and then you power up, the address will default to 40. NODE ADDRESS (00-63 PGM) 9 0 1 8 7 6 5 4 2 3 MSD 9 0 1 8 7 6 5 4 2 3 LSD Bottom View of Module Example: Node Address is set at 62, see small black dots. Publication 1792D-IN051A-EN-P - February 2001 41462 4 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B The module is equipped with AutoBaud detect. AutoBaud lets the module read the settings already in use on your DeviceNet network and automatically adjusts to follow those settings. Install the Module This module mounts to the following cable bases: • 1792D-CBFM for KwikLink™ flat media installation • 1792D-CB12 for 12mm drop cable installation • 1792D-CB18 for round media trunk connection • or other optional cable base assembly. IMPORTANT The cable base should already be installed. See publication 1792D-IN009B-EN-P to install the cable base. To install the module: IMPORTANT Proper alignment of the screws is necessary to complete the connections between the module contacts and the cable contacts. 1. Position the module over the mounted cable base. Align the three captive screws in the module with the accepting receptacles in the base. 2. Tighten the screws to secure the module to the base. Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B 5 Note: Dimensions change according to the cable base and module combination used. 2.7 (68.6) 6.85 (174mm) Assembled dimensions in (mm) Align the screws to properly assemble the module to the base. 1.9 (48.26) Cable Base 1792D-CBFM is used for this example. 42762 Connect the Input Cord Sets to the MaXum Module This module uses 5 pin micro (12mm) style PCB mounted connectors. Eight micro caps cover the connectors on your module. Remove the caps and connect your cord sets to the appropriate ports. This product has two inputs per connector. Use the micro caps to cover and seal unused ports. A pinout diagram for the connectors is shown next. Input Micro-Connector (View into Socket) Pin 1 Sensor Source voltage Pin 3 Return Logic Ground1 Pin 4 Input A Pin 5 Not Used 1Logic Ground is approximately 0.4V above DeviceNet V- measured at the module. Publication 1792D-IN051A-EN-P - February 2001 41452 6 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Please refer to publication 889-CP001A-EN-P and 889-TD001A-EN-P for Rockwell Automation cables and cord sets offerings. IMPORTANT If the devices (sensors) connected to the input connections require Class 2 power to operate, the DeviceNet connections of this equipment must be powered by a Class 2 source. • Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP67 requirements. • For maximum noise immunity, input cable return wires must be properly terminated. When inputs are connected in loopback, return wires should be connected together. • I/O cable length should be less than 30 meters. ATTENTION ÿ I/O connectors for this module are shown below. Connector A Input 0 Input 7 Connector H Connector B Input 1 Input 6 Connector G Connector C Input 2 Input 5 Connector F Connector D Input 3 Input 4 Connector E 42763 Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B 7 DeviceNet Cables DeviceNet cables are described in the installation publications for the cable base assembly of your choice. Refer to the following publications: • 1792D-IN009B-EN-P ArmorBlock MaXum Cable Base Installation Guide • DN-6.7.2 DeviceNet Cable Planning and Installation Manual Communicate With Your ArmorBlock MaXum I/O Module This ArmorBlock module’s I/O is exchanged with the master through a poll, change-of-state, or cyclic connection. The module consumes and produces I/O data as follows: Type of I/O Connections Consumes Produces Cyclic 0 Byte 3 Bytes Polled 0 Byte 3 Bytes Change-of-State 0 Byte 3 Bytes Cyclic - allows configuration of the block as an I/O client. The block will produce its I/O cyclically at the rate configured. Polled - a master initiates communication by sending its polled I/O message to the module. The 8 input module cans the inputs and fault bits producing a response that reflects their status. Change-of-State - productions occur when an input changes or a fault condition occurs. If no input or fault condition change occurs within the expected packet rate, a heartbeat production occurs. This heartbeat production tells the scanner module that the module is alive and ready to communicate. Refer to the table below for the word/bit definitions. Bit 07 06 05 04 03 02 01 00 Produced 0 I7 I6 I5 I4 I3 I2 I1 I0 Produced 1 ISC-H ISC-G ISC-F ISC-E ISC-D ISC-C ISC-D ISC-A Produced 2 OW-H OW-G OW-F OW-E OW-D OW-C OW-B OW-A Where: I = Input; ISC=Input Short Circuit in Sensor Source Voltage; OW= Off Wire Publication 1792D-IN051A-EN-P - February 2001 8 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Byte Bit Description Produces 0 00-07 Input Status bits: When the bit is set (1), the input is on. Bit 00 = input 0, bit 01 = input 1, bit 02 = input 2, bit 03 = input 3, bit 04 = input 4, bit 05 = input 5, bit 06 = input 6, bit 07 = input 7. Produces 1 00-07 Sensor source voltage, input short circuit (ISC): Fault bits are set (1) when the sensor source voltage is faulted. Bit 00 = ISC-A on connector A, bit 01 = ISC-B on connector B, bit 02 = ISC-C on connector C, bit 03 = ISC-D on connector D, bit 04 = ISC-E on connector E, bit 05 = ISC-F on connector F, bit 06 = ISC-G on connector G, bit 07 = ISC-H on connector H. Produces 2 00-07 Off-Wire fault (OW): Bit 00 = OW-A on connector A, bit 01 = OW-B on connector B, bit 02 = OW-C on connector C, bit 03 = OW-D on connector D, bit 04 = OW-E on connector E, bit 05 = OW-F on connector F, bit 06 = OW-G on connector G, bit 07 = OW-H on connector H. The DeviceNet Network uses advanced network technology, producer/consumer communication, to increase network functionality and throughput. Visit our web site at http://www.ab.com/networks for producer/consumer technology information and updates. Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Troubleshoot with the Indicators This module has the following indicators: • Network and Module status indicator • Logic status indicator • Individual I/O status indicators for inputs 0 through 7. Point indicator for Input 7 Point indicator for input 0 Connector A Connector H Point indicator for Input 6 Point indicator for input 1 Connector B Connector G Point indicator for Input 5 Point indicator for input 2 Connector C Connector F Point indicator for input 3 Point indicator for Input 4 Connector D Connector E Module Status Indicators Information on connectors A through H can be found in the table on page 8. 42763 LED Assignments The following table describes network and module status indicators. Net/Mod Status Indicator Indicator Status Off No power or auto bauding Flashing Green/Off On line but not connected Solid Green On line, link OK, connected Flashing Red Recoverable fault - module configuration error I/O connection fault - one or more I/O connections in the timed-out state Publication 1792D-IN051A-EN-P - February 2001 9 10 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Net/Mod Status Indicator (continued) Solid Red Unrecoverable fault Communication failure - duplicate node address present or incorrect baud rate Green to Red to Off At powerup only - LED test The following table describes logic status indicators. Logic Status Indicators State Status Off Logic is disabled Solid Green Logic is enabled Flashing Green Local forces are applied and local logic is enabled The following table describes auxiliary power indicators. Auxiliary Power Indication Status None No Auxiliary Power Green Solid Auxiliary Power Present The following table describes individual I/O status indicators. I/O Status Indicators Function Module Status Indicator Point Indicator Condition Inputs Green Green Module Status blink red Module Status blink red None Yellow Red Blink red No valid input Valid input Short on input connector Off wire on input connector For more information on indications see the Technical Data publication 1792-TD001B-EN-P. Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B 11 Hazardous Location Approval The following information applies only to products marked with Hazardous Location Approval, when operating in hazardous locations: Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest “T” number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. WARNING ÿ • Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. • Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. • Substitution of components may impair suitability for Class I, Division 2. • If this product contains batteries, they must only be changed in an area known to be nonhazardous. WARNING ÿ Use supply wires suitable for 30°C above surrounding ambient. Publication 1792D-IN051A-EN-P - February 2001 12 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B WARNING ÿ When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes. Les informations suivantes ne concernent que les produits marqués pour une utilisation en environnements dangereux : Les produits marqués « CL I, DIV 2, GP A, B, C, D » ne conviennent qu’à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d’identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d’équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l’installation. AVERTISSEMENT ÿ RISQUE D’EXPLOSION • Couper le courant ou s’assurer que l’environnement est classé non dangereux avant de débrancher l’équipement. • Couper le courant ou s’assurer que l’environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l’aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. • La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe I, Division 2. • S’assurer que l’environnement est classé non dangereux avant de changer les piles. Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B 13 AVERTISSEMENT ÿ AVERTISSEMENT ÿ Utiliser des fils d’alimentation qui conviennent à une température de 30°C au-dessus de la température ambiante. Pour une utilisation en environnement de classe i, division 2 dangereux, cet equipement doit etre monte dans un boitier avec un cablage approprie conforme aux normes electriques en vigueur. This product has been tested at an Open DeviceNet Vendor Association, Inc. (ODVA) authorized independent test laboratory and found to comply with ODVA Conformance Test. Please contact the ODVA website (http://www.odva.org) for listing of products tested by ODVA independent test labs for further details. Publication 1792D-IN051A-EN-P - February 2001 14 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Specifications 8 Input Module - Cat. No. 1792D-8BVOD Input Specifications Max. Inputs per block 8 - 3 wire or dry contact PNP or NPN devices or 8 4 wire PNP or NPN devices Min. Sensor Source Current (per input) 50mA On-state Voltage 25V dc 10V dc On-state Current 10mA 2mA Off-state Voltage 5V dc - Off-state Current - 1.5mA Off-Wire Sense Current 0.5mA - General Specifications Indicators Net/Mod Status - red/green Logic Status - red/green Point LED - yellow/orange/red Communication Rate •125Kbps @ 500 meters(1600 feet) for thick cable, flat media length 375 meters •250Kbps @ 200 meters(600 feet) for thick cable, flat media length 150 meters • 500Kbps @ 100 meters (330 feet) for thick cable, flat media length 75 meters DeviceNet Power Voltage Current Refer to the graphs in the Overview section of the ArmorBlock I/O Family Technical Data, pub. no. 1792-TD001B-EN-P. 25V dc max 200mA max (no sensors) Dimensions (assembled to base) inches - (Millimeters) 1.9H x 2.7w x6.85D (48.26)H x (68.6)W x (174)D Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors 11V dc min up to 1.6A (8 sensors @50mA per sensor) -25 to 60o (-13 to 140oF) -25 to 80oC (-13 to 176OF) Up to 100% 30g peak acceleration, 11 (+1) ms pulse width 50g peak acceleration, 11(+1)ms pulse width Tested 10g @ 10-500Hz per IEC 68-2-6 Publication 889-CP001A-US-P Enclosure Meets or exceeds IP67 Agency Certification (when product is marked) CSA certified CSA Class I, Division 2, Groups A, B, C, D certified UL listed CE marked for all applicable directives Technical Data (user information) Publication 1792-TD001B-EN-P Publication 1792D-IN051A-EN-P - February 2001 ArmorBlock MaXum 8 Input Module with 8 Connectors, Series B Notes: Publication 1792D-IN051A-EN-P - February 2001 15 Allen-Bradley is a registered trademark of Rockwell Automation. ArmorBlock, ArmorBlock MaXum, DeviceNetManager and KwikLink are trademarks of Rockwell Automation. DeviceNet is a trademark of Open DeviceNet Vendor Association. RSNetWorx for DeviceNet is a trademark of Rockwell Software, Inc. Publication 1792D-IN051A-EN-P - February 2001 PN 957485-03 © 2001 Rockwell International Corporation. Printed in USA ">
Advertisement