Allen-Bradley Compact Solid State 24V dc Source Output Module Installation Instructions
Allen-Bradley Compact Solid State 24V dc Source Output Module is a versatile and reliable solution for controlling industrial equipment. This module provides 16 discrete outputs, each capable of delivering up to 1.0A at 30°C or 0.5A at 60°C. It features electronic protection against overcurrent, short-circuit, and undervoltage conditions, ensuring safe and reliable operation in various industrial environments. The module supports both panel and DIN rail mounting and is compatible with a range of Allen-Bradley controllers and systems, including MicroLogix, CompactLogix, and DeviceNet adapters. With its robust construction, user-friendly design, and comprehensive features, the Allen-Bradley Compact Solid State 24V dc Source Output Module is an ideal choice for a variety of automation applications.
Advertisement
Advertisement
Installation Instructions Compact™ Solid State 24V dc Source Output Module with Electronic Protection (Catalog Number 1769-OB16P, Series B) Inside Module Description ..................................................................................2 Module Installation...................................................................................3 System Assembly......................................................................................4 Mounting Expansion I/O ...........................................................................5 Replacing a Single Module within a System ...........................................7 Field Wiring Connections..........................................................................8 I/O Memory Mapping .............................................................................11 Electronic Protection ............................................................................. 13 Spare/Replacement Module Parts ....................................................... 14 Specifications .........................................................................................15 Hazardous Location Considerations .......................................................19 Environnements dangereux ....................................................................19 For More Information ..............................................................................20 Publication 1769-IN052A-EN-P - April 2001 2 Compact™ Solid State 24V dc Source Output Module with Electronic Protection Module Description 1 2a Item Description 1 bus lever (with locking function) 2a upper panel mounting tab 2b lower panel mounting tab 3 I/O diagnostic LEDs 4 module door with terminal identification label 5a movable bus connector with female pins 1769-OB16P 5b stationary bus connector with male pins 2b 6 nameplate label 7a upper tongue-and-groove slots 7b lower tongue-and-groove slots 8a upper DIN rail latch 8b lower DIN rail latch 9 write-on label (user ID tag) 10 removable terminal block (RTB) with finger-safe cover 10a RTB upper retaining screw 10b RTB lower retaining screw 3 DANGER Do Not Remove RTB Under Power Unless Area is Non-Hazardous 10a OUT 0 OUT 2 + VDC OUT 1 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 10 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 10b OUT 14 DC COM OUT 15 Ensure Adjacent Bus Lever is Unlatched/Latched Before/After Removing/Inserting Module 4 8a 7a 7a 5a 5b 9 6 7b 7b 8b Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 3 Module Installation Compact I/O is suitable for use in an industrial environment when installed in accordance with these instructions. Specifically, this equipment is intended for use in clean, dry environments (Pollution degree 2(1)) and to circuits not exceeding Over Voltage Category II(2) (IEC 60664-1).(3) Prevent Electrostatic Discharge ATTENTION ! Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. Follow these guidelines when you handle the module: • Touch a grounded object to discharge static potential. • Wear an approved wrist-strap grounding device. • Do not touch the bus connector or connector pins. • Do not touch circuit components inside the module. • If available, use a static-safe work station. • When not in use, keep the module in its static-shield box. Remove Power ATTENTION ! (1) (2) (3) Remove power before removing or inserting this module. When you remove or insert a module with power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: • sending an erroneous signal to your system’s field devices, causing unintended machine motion • causing an explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation shall be expected. Over Voltage Category II is the load level section of the electrical distribution system. At this level transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insulation. Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC) designations. Publication 1769-IN052A-EN-P - April 2001 4 Compact™ Solid State 24V dc Source Output Module with Electronic Protection System Assembly The module can be attached to the controller or an adjacent I/O module before or after mounting. For mounting instructions, see “Panel Mounting” on page 5, or “DIN Rail Mounting” on page 7. To work with a system that is already mounted, see “Replacing a Single Module within a System” on page 7. The following procedure shows you how to assemble the Compact I/O system. 3 4 2 1 6 1 5 1. Disconnect power. 2. Check that the bus lever of the module to be installed is in the unlocked (fully right) position. 3. Use the upper and lower tongue-and-groove slots (1) to secure the modules together (or to a controller). 4. Move the module back along the tongue-and-groove slots until the bus connectors (2) line up with each other. 5. Push the bus lever back slightly to clear the positioning tab (3). Use your fingers or a small screwdriver. 6. To allow communication between the controller and module, move the bus lever fully to the left (4) until it clicks. Ensure it is locked firmly in place. ATTENTION When attaching I/O modules, it is very important that the bus connectors are securely locked together to ensure proper electrical connection. ! Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 5 7. Attach an end cap terminator (5) to the last module in the system by using the tongue-and-groove slots as before. 8. Lock the end cap bus terminator (6). A 1769-ECR or 1769-ECL right or left end cap must be used to terminate the end of the serial communication bus. IMPORTANT Mounting Expansion I/O ATTENTION ! During panel or DIN rail mounting of all devices, be sure that all debris (metal chips, wire strands, etc.) is kept from falling into the module. Debris that falls into the module could cause damage on power up. Minimum Spacing End Cap Compact I/O Compact I/O Compact I/O Controller Side Compact I/O Top Compact I/O Maintain spacing from enclosure walls, wireways, adjacent equipment, etc. Allow 50 mm (2 in.) of space on all sides for adequate ventilation, as shown: Side Bottom Panel Mounting Mount the module to a panel using two screws per module. Use M4 or #8 panhead screws. Mounting screws are required on every module. Publication 1769-IN052A-EN-P - April 2001 6 Compact™ Solid State 24V dc Source Output Module with Electronic Protection Panel Mounting Using the Dimensional Template Right End Cap Compact I/O Compact I/O 122.6±0.2 (4.826±0.008) 28.5 (1.12) 35 (1.38) Compact I/O 132 (5.197) Host Controller For more than 2 modules: (number of modules-1) x 35 mm (1.38 in.) Refer to host controller documentation for this dimension. NOTE: All dimensions are in mm (inches). Hole spacing tolerance: ±0.4 mm (0.016 in.) Panel Mounting Procedure Using Modules as a Template The following procedure allows you to use the assembled modules as a template for drilling holes in the panel. If you have sophisticated panel mounting equipment, you can use the dimensional template provided on page 6. Due to module mounting hole tolerance, it is important to follow these procedures: 1. On a clean work surface, assemble no more than three modules. 2. Using the assembled modules as a template, carefully mark the center of all module-mounting holes on the panel. 3. Return the assembled modules to the clean work surface, including any previously mounted modules. 4. Drill and tap the mounting holes for the recommended M4 or #8 screw. 5. Place the modules back on the panel, and check for proper hole alignment. 6. Attach the modules to the panel using the mounting screws. TIP If mounting more modules, mount only the last one of this group and put the others aside. This reduces remounting time during drilling and tapping of the next group. 7. Repeat steps 1 to 6 for any remaining modules. Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 7 DIN Rail Mounting The module can be mounted using the following DIN rails: 35 x 7.5 mm (EN 50 022 - 35 x 7.5) or 35 x 15 mm (EN 50 022 - 35 x 15). Before mounting the module on a DIN rail, close the DIN rail latches. Press the DIN rail mounting area of the module against the DIN rail. The latches will momentarily open and lock into place. Replacing a Single Module within a System The module can be replaced while the system is mounted to a panel (or DIN rail). Follow these steps in order: 1. Remove power. See important note on page 3. 2. On the module to be removed, remove the upper and lower mounting screws from the module (or open the DIN latches using a flat-blade or phillips-style screwdriver). 3. Move the bus lever to the right to disconnect (unlock) the bus. 4. On the right-side adjacent module, move its bus lever to the right (unlock) to disconnect it from the module to be removed. 5. Gently slide the disconnected module forward. If you feel excessive resistance, check that the module has been disconnected from the bus, and that both mounting screws have been removed (or DIN latches opened). TIP It may be necessary to rock the module slightly from front to back to remove it, or, in a panel-mounted system, to loosen the screws of adjacent modules. 6. Before installing the replacement module, be sure that the bus lever on the module to be installed, and on the right-side adjacent module, are in the unlocked (fully right) position. 7. Slide the replacement module into the open slot. 8. Connect the modules together by locking (fully left) the bus levers on the replacement module and the right-side adjacent module. 9. Replace the mounting screws (or snap the module onto the DIN rail). Publication 1769-IN052A-EN-P - April 2001 8 Compact™ Solid State 24V dc Source Output Module with Electronic Protection Field Wiring Connections Grounding the Module This product is intended to be mounted to a well-grounded mounting surface such as a metal panel. Additional grounding connections from the module’s mounting tabs or DIN rail (if used), are not required unless the mounting surface cannot be grounded. Refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1, for additional information. Output Wiring Basic wiring(1) of output devices(2) to the 1769-OB16P is shown below. ATTENTION ! • Miswiring of the module to an AC power source will damage the module. • Bipolar loads will turn on if the power source is connected in reverse. • Be careful when stripping wires. Wire fragments that fall into a module could cause damage at power up. Once wiring is complete, ensure the module is free of all metal fragments. CR OUT 0 CR OUT 2 OUT 4 CR OUT 6 CR OUT 8 OUT 10 OUT 12 OUT 14 DC COM +DC +VDC OUT 1 CR OUT 3 CR OUT 5 OUT 7 CR OUT 9 CR OUT 11 CR OUT 13 CR 24V dc OUT 15 -DC (1) (2) Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V dc inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1. Sourcing Output - Source describes the current flow between the I/O module and the field device. Sourcing output circuits supply (source) current to sinking field devices. Field devices connected to the negative side (DC Common) of the field power supply are sinking field devices. Field devices connected to the positive side (+V) of the field supply are sourcing field devices. Europe: DC sinking input and sourcing output module circuits are the commonly used options. Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 9 A removable, write-on label is provided with the module. Remove the label from the door, mark the identification of each terminal with permanent ink, and slide the label back into the door. Your markings (ID tag) will be visible when the module door is closed. SLOT # _____ MODULE TYPE ______ Removing the Finger-Safe Terminal Block When wiring field devices to the module, it is not necessary to remove the terminal block. If you remove the terminal block, use the write-on label on the side of the terminal block to identify the module slot lcation and type. To remove the terminal block, loosen the upper and lower retaining screws. The terminal block will back away from the module as you remove the screws. When replacing the terminal block, torque the retaining screws to 0.46 Nm (4.1 in-lbs). Wiring the Finger-Safe Terminal Block upper retaining screw wiring the finger-safe terminal block lower retaining screw When wiring the terminal block, keep the finger-safe cover in place. 1. Loosen the terminal screws to be wired. Publication 1769-IN052A-EN-P - April 2001 10 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 2. Route the wire under the terminal pressure plate. You can use the bare wire or a spade lug. The terminals will accept a 6.35 mm (0.25 in.) spade lug. TIP The terminal screws are non-captive. Therefore, it is possible to use a ring lug [maximum 1/4 inch o.d. with a 0.139 inch minimum i.d. (M3.5)] with the module. 3. Tighten the terminal screw making sure the pressure plate secures the wire. Recommended torque when tightening terminal screws is 0.68 Nm (6 in-lbs) TIP If you need to remove the finger-safe cover, insert a screwdriver into one of the square wiring holes and gently pry the cover off. If you wire the terminal block with the finger-safe cover removed, you will not be able to put it back on the terminal block because the wires will be in the way. Simplified Output Circuit Diagram Vcc 6V +VDC Voltage Regulator 100pF 39V 39V OUT 47K NOTE: Protection circuit not shown. DC COM Wire Size and Terminal Screw Torque Each terminal accepts up to two wires with the following restrictions: Wire Type Wire Size Terminal Screw Torque Retaining Screw Torque Solid Cu-90°C (194°F) #14 to #22 AWG 0.68 Nm (6 in-lbs) 0.46 Nm (4.1 in-lbs) Stranded Cu-90°C (194°F) #16 to #22 AWG 0.68 Nm (6 in-lbs) 0.46 Nm (4.1 in-lbs) Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 11 I/O Memory Mapping Output Data File Word For each module, slot x, word 0 in the output data file contains the control program’s directed state of the discrete output points. 15 w 0 14 w 13 w 12 w 11 w 10 w 9 w Bit Position 8 7 6 w w w 5 w 4 w 3 w 2 w 1 w 0 w w = write Output Module’s Input Data File For each module, slot x, input data file word 0 contains the state of the module’s output data (output data echo) file word 0. During normal operation, these input bits represent the logic state that the outputs are directed to by the control program. They are also dependent upon the: • Program Mode(1) configuration (if supported by the controller/adapter) Word • The Fault Mode(1) configuration (if supported by the controller/adapter) 15 r 0 14 r 13 r 12 r 11 r 10 r 9 r Bit Position 8 7 r r 6 r 5 r 4 r 3 r 2 r 1 r 0 r r = read IMPORTANT TIP (1) The output module’s input data file reflects the output data echo of the module, not necessarily the electrical state of the output terminals. It does not reflect shorted or open outputs. It is only important to use this input word if the controller/adapter supports the Program Mode or Fault Mode function, and if it is configured to use them. Not supported by MicroLogix 1500. Publication 1769-IN052A-EN-P - April 2001 12 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 1769-OB16P Configuration File Word The read/writable configuration data file allows the setup of the hold last state and user-defined safe state conditions. The manipulation of the bits from this file is normally done with programming software (e.g. RSLogix 500, RSNetworx for DeviceNet, etc.) during initial configuration of the system. In that case, graphical screens are provided to simplify programming. However, some systems (for example, 1769-ADN DeviceNet Adapter) allow the bits to be altered as part of the control program, using communication rungs. In that case, it is necessary to understand the bit arrangement, as described below. 15 14 13 0 1 2 3 4 12 11 Bit Position 9 8 7 6 5 Not Used (Default = 0) Program State for Output Array Word 0 Program Value for Output Array Word 0 Fault State for Output Array Word 0 Fault Value for Output Array Word 0 10 4 3 2 1 0 PFE Program State Word Word 1, the program state word, selects the hold last state or user-defined safe state condition for each individual output on a system transition from Run to Program. Condition Bit Setting User-defined Safe State 0 Hold Last State 1 Condition Bit Setting Off 0 On 1 Condition Bit Setting User-defined Safe State 0 Hold Last State 1 Program Value Word The program value word, word 2, is used to program the user-defined safe state condition. Each output is individually configurable for on or off. Fault State Word Word 3, the fault state word, selects the hold last state or user-defined safe state condition for each individual output on a system transition from Run to Fault. Fault Value Word The fault value word, word 4, is used to program the fault state condition. Each output is individually configurable for on or off. Publication 1769-IN052A-EN-P - April 2001 Condition Bit Setting Off 0 On 1 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 13 Program to Fault Enable Bit (PFE) Word 0, bit 0, allows the selection of which data value, the program or fault value, to apply to the output if a system in Program mode undergoes a system fault, resulting a change to Fault mode. Value Applied Bit Setting Program 0 Fault 1 Module Default Condition The modules default condition is all zeros, programming the conditions shown below. Word or Bit Affected Condition Applied Word 0, Bit 0: Program-to-Fault Enable Program Value Word 1: Program State User-defined Safe State Word 2: Program Value Off Word 3: Fault State User-defined Safe State Word 4: Fault Value Off Electronic Protection The 1769-OB16P module provides electronic overcurrent (overload), short-circuit, and undervoltage protection as described below. Overcurrent and Short-Circuit The 1769-OB16P performs auto-reset during overload conditions. Overcurrent and short-circuit protection is based on the thermal cut-out principle. In the event of a short circuit or overload on an output point, the output point limits the current within milliseconds after its thermal cut-out temperature is reached. All other points continue to operate as directed by the processor. After the output point’s thermal cut-off device cools, the output automatically resets (auto-reset function). If the overcurrent or short-circuit condition still exists, the protection cycle repeats until it is removed. IMPORTANT An external short of the output point to the field supply voltage causes the load to turn on regardless of the 1769-OB16P commanded on/off state. This occurs because of the direct connection of the load to the field power supply. However, it will not damage the 1769-OB16P. Publication 1769-IN052A-EN-P - April 2001 14 Compact™ Solid State 24V dc Source Output Module with Electronic Protection TIP Short-circuits and overload conditions should be corrected as soon as possible. Damage may occur if short-circuits or overload conditions are allowed for extended periods or if multiple short-circuits or overload conditions occur at the same time. Timing Diagram for Over-current or Short-Circuit Shut-down and Re-start IN1 Other Channel: normal operation IL1 IL(SCp) IL(SCr) toff(SC) IN1 – Commanded state of output channel IL1 – Output current due to short-circuit overload IL(SCp) – Peak short-circuit or overload current toff(SC) – Time before shut-off occurs. This may take several milliseconds depending on external conditions. IL(SCr) – Recurring short-circuit or overload current Under-Voltage Condition If the field supply voltage falls below a value of approximately 4V dc, all the 1769-OB16P outputs shut down and remain off until the field supply voltage returns to a value within the module’s normal operating range. Spare/Replacement Module Parts • Terminal block: 1769-RTB18 (1 per kit) • Door Labels: 1769-RL1 (2 per kit) • Door: 1769-RD (2 per kit) Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 15 Specifications General Specifications Specification Value Dimensions 118 mm (height) x 87 mm (depth) x 35 mm (width) height including mounting tabs is 138 mm 4.65 in. (height) x 3.43 in (depth) x 1.38 in (width) height including mounting tabs is 5.43 in. Approximate Shipping Weight (with carton) 255 g (0.56 lbs.) Storage Temperature -40°C to +85°C (-40°F to +185°F) Operating Temperature 0°C to +60°C (32°F to +140°F) Operating Humidity 5% to 95% non-condensing Operating Altitude 2000 meters (6561 feet) Vibration Operating: 10 to 500 Hz, 5G, 0.030 in. maximum peak-to-peak Relay Operation: 2G Shock Operating: 30G panel mounted (20G DIN rail mounted) Relay Operation: 7.5G panel mounted (5G DIN rail mounted) Non-Operating: 40G panel mounted (30G DIN rail mounted) Agency Certification • • • Hazardous Environment Class Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) Radiated and Conducted Emissions EN50081-2 Class A Electrical /EMC: The module has passed testing at the following levels: ESD Immunity (IEC61000-4-2) • 4kV contact, 8 kV air, 4 kV indirect Radiated Immunity (IEC61000-4-3) • 10 V/m, 80 to 1000 MHz, 80% amplitude modulation, +900 MHz keyed carrier Fast Transient Burst (IEC61000-4-4) • 2 kV, 5 kHz Surge Immunity (IEC61000-4-5) • 2 kV common mode, 1 kV differential mode Conducted Immunity (IEC61000-4-6) • (1) C-UL certified (under CSA C22.2 No. 142) UL 508 listed CE and C-Tick compliant for all applicable directives 10V, 0.15 to 80 MHz(1) Conducted Immunity frequency range may be 150 kHz to 30 MHz if the Radiated Immunity frequency range is 30 MHz to 1000 MHz. Publication 1769-IN052A-EN-P - April 2001 16 Compact™ Solid State 24V dc Source Output Module with Electronic Protection Output Specifications Specification 1769-OB16P Voltage Category 24V dc Operating Voltage Range 20.4V dc to 26.4V dc (source(1)) Number of Outputs 16 Bus Current Draw (max.) 160 mA at 5V dc (0.8 W) Heat Dissipation 2.69 Total Watts (The Watts per point, plus the minimum Watts, with all points energized.) Signal Delay (at max. resistive load) turn-on = 1.0 ms turn-off = 2.0 ms Off-State Leakage (max.)(2) 1.0 mA at 26.4V dc On-State Current (min.) 1.0 mA On-State Voltage Drop (max.) 0.5V dc Continuous Current Per Point (max.) See the derating graphs on page 17. 0.5A at 60°C (140°F) 1.0A at 30°C (86°F) Continuous Current Per Module (max.) See the derating graphs on page 17. 4.0A at 60°C (140°F) 8.0A at 30°C (86°F) Surge Current (max.)(3) 2.0A (Repeatability is once every 1 second for a duration of 10 msec.) Power Supply Distance Rating 8 (The module may not be more than 8 modules away from the power supply.) Output Point to Compact Bus Isolation Verified by one of the following dielectric tests: 1200V ac for 1 sec. or 1697V dc for 1 sec. 75V dc working voltage (IEC Class 2 reinforced insulation) Isolated Groups Group 1: outputs 0 to 15 (internally connected common) Vendor I.D. Code 1 Product Type Code 7 Product Code 91 (1) Sourcing Output - Source describes the current flow between the I/O module and the field device. Sourcing output circuits supply (source) current to sinking field devices. Field devices connected to the negative side (DC Common) of the field power supply are sinking field devices. Field devices connected to the positive side (+V) of the field supply are sourcing field devices. Europe: DC sinking input and sourcing output module circuits are the commonly used options. (2) Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can be connected in parallel with your load. Use a 5.6K ohm, ½ watt resistor for transistor outputs, 24V dc operation. (3) Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V dc inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1. Publication 1769-IN052A-EN-P - April 2001 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 17 Temperature Derating The area within the curve represents the safe operating range for the module under various conditions of user-supplied voltages and ambient temperatures. 1769-OB16P Maximum Amperes Per Point vs. Temperature 1.00 0.95 Maximum Amperes Per Point 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 30˚C (86˚F) 40˚C (104˚F) 50˚C (122˚F) 60˚C (140˚F) Ambient Temperature 1769-OB16P Maximum Amperes Per Module vs. Temperature 8.00 Maximum Amperes Per Module 7.50 7.00 6.50 6.00 5.50 5.00 4.50 4.00 30˚C (86˚F) 40˚C (104˚F) 50˚C (122˚F) 60˚C (140˚F) Ambient Temperature Publication 1769-IN052A-EN-P - April 2001 18 Compact™ Solid State 24V dc Source Output Module with Electronic Protection Transistor Output Transient Pulses The maximum duration of the transient pulse occurs when minimum load is connected to the output. However, for most applications, the energy of the transient pulse is not sufficient to energize the load. A transient pulse occurs in transistor outputs when the external DC supply voltage is applied to the output common terminals (e.g. via the master control relay). The sudden application of voltage creates this transient pulse. This condition is inherent in transistor outputs and is common to solid state devices. A transient pulse can occur regardless of the controller having power or not. Refer to your controller’s user manual to reduce inadvertent operation. ATTENTION ! The graph below illustrates that the duration of the transient is proportional to the load current. Therefore, as the on-state load current increases, the transient pulse decreases. Power-up transients do not exceed the time duration shown below, for the amount of loading indicated, at 60°C (140°F). Transient Pulse Duration as a Function of Load Current 1.0 0.9 Time - Duration of Transient (ms) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 1 100 200 300 400 500 600 700 On-State Load Current (mA) Publication 1769-IN052A-EN-P - April 2001 800 900 1000 Compact™ Solid State 24V dc Source Output Module with Electronic Protection 19 Hazardous Location Considerations This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. The following WARNING statement applies to use in hazardous locations. WARNING ! EXPLOSION HAZARD • Substitution of components may impair suitability for Class I, Division 2. • Do not replace components or disconnect equipment unless power has been switched off or the area is known to be non-hazardous. • Do not connect or disconnect components unless power has been switched off or the area is known to be non-hazardous. • This product must be installed in an enclosure. • All wiring must comply with N.E.C. article 501-4(b). Environnements dangereux Cet équipement est conçu pour être utilisé dans des environnements de Classe 1, Division 2, Groupes A, B, C, D ou non dangereux. La mise en garde suivante s’applique à une utilisation dans des environnements dangereux. AVERTISSEMENT ! DANGER D’EXPLOSION • La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement de Classe 1, Division 2. • Ne pas remplacer de composants ou déconnecter l'équipement sans s'être assuré que l'alimentation est coupée. • Ne pas connecter ou déconnecter des composants sans s'être assuré que l'alimentation est coupée. • Ce produit doit être installé dans une armoire. Publication 1769-IN052A-EN-P - April 2001 For More Information For Refer to this Document A more detailed description of how to install and MicroLogix 1200 & 1500 use your Compact™ I/O with MicroLogix™ 1200 Programmable Controllers User and 1500 programmable controller. Manual Pub. No. 1764-UM001B-US-P A more detailed description of how to install and 1769-ADN DeviceNet Adapter User 1769-UM001A-US-P use your Compact I/O with the 1769-ADN Manual DeviceNet Adapter. A more detailed description of how to install and CompactLogix System User Manual 1769-UM007C-EN-P use your Compact I/O with the CompactLogix™ System. More information on proper wiring and grounding techniques. Industrial Automation Wiring and Grounding Guidelines 1770-4.1 If you would like a manual, you can: • download a free electronic version from the internet: www.ab.com/micrologix or www.theautomationbookstore.com • purchase a printed manual by: – contacting your local distributor or Rockwell Automation representative – visiting www.theautomationbookstore.com and placing your order – calling 1.800.963.9548 (USA/Canada) or 001.330.725.1574 (Outside USA/Canada) Compact, MicroLogix, CompactLogix, RSLogix and RSNetworx are trademarks of Rockwell Automation. DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA). Publication 1769-IN052A-EN-P - April 2001 Supersedes Publication 1769-IN004A-US-P - April 2000 PN 40072-117-01 (A) © 2001 Rockwell International Corporation. Printed in the U.S.A. ´H'51!¶A¢¨ ">
Key Features
- 16 Outputs
- 1.0A at 30°C
- Electronic Protection
- Panel & DIN Rail
- MicroLogix & CompactLogix