Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the radio frequency conducted emissions into the main supply lines and ground wiring. This publication provides the steps needed to install the filter. Important: Declarations of Conformity to the European Union Directives are available for Allen-Bradley AC drive products. Please contact your Allen-Bradley Sales Representative. ATTENTION: The CE filter connects between the incoming AC supply line and the drive input terminals. The filter must be installed by qualified personnel familiar with the drive and associated machinery. Failure to comply may result in personal injury and/or equipment damage. ATTENTION: An incorrectly applied or installed CE filter can result in component damage or a reduction in product life. Wiring or application errors, such as incorrect wiring layout, incorrect or inadequate AC supply or excessive ambient temperatures may result in malfunction of the system. Refer to the page listed below for installation instructions. • Internal Mount Option – See page 2. • NEMA 12 Enclosed Option – See page 5. 2 1329I Integrated Drive/Motor CE Filter Option Kit Internal Mount Installation Use the cross-reference table below to verify that the correct filter has been selected for your CE compatible drive. Filter Selection Filter Catalog Number Series Ratings Use with Bulletin 1329I Series B Drive/Motor 1329I-NLF1 A 115/230 VAC Single Phase 14 Amps 1329I-BJ 1329I-BK 1329I-NLF3 A 230/460 VAC Three Phase 9 Amps 1329I-BL 1329I-BM Components Supplied Item Quantity Supplied Quantity Required to Install Screws M4 × 8 TT 5 4 Lock Washers M4 Internal Tooth 5 4 1329I Integrated Drive/Motor CE Filter Option Kit 3 Filter Installation ATTENTION: To prevent electrical shock, disconnect the power source before installing or servicing. ATTENTION: After disconnecting input power wait five minutes and check with voltmeter to assure that DC bus capacitors are discharged (DC+, DC-). The voltmeter should read zero volts. Failure to observe these precautions could result in severe bodily injury or loss of life. 1. Remove the cover of the 1329I unit by loosening the four cover screws. The display ribbon cable is designed to disconnect from the main unit when the cover is removed. 2. Mount the CE filter as shown in the figure below using the screws provided. 1.46 Nm (13 in-lb) 2.6 Nm (23 in-lb) 3. The CE filter must be connected between the incoming AC supply line and the drive input terminals. Important: The filter may cause ground leakage currents. Therefore, a solid ground connection must be provided as shown on the following page. 4 1329I Integrated Drive/Motor CE Filter Option Kit ATTENTION: To guard against possible equipment damage, RFI filters can only be used with AC supplies that are nominally balanced with respect to ground. In some installations, threephase supplies are occasionally connected in a 3-wire configuration with one phase grounded (Grounded Delta). The filter must not be used in Grounded Delta supplies. Filter Wiring CE Filter Conduit/4-Wire Cable L1 1329I Integrated Drive Motor W1 IN OUT L2 W2 L3 W3 OUT IN OUT IN R/L1 S/L2 T/L3 PE Nearest Building Structure Steel 4. Connect wires as shown in the diagram below. (Three Phase unit shown.) 1.3 Nm (12 in-lb) L1 L2 L3 PE DC+ DCDBR T/L3 S/L2 R/L1 1.3 Nm (12 in-lb) 1329I Integrated Drive/Motor CE Filter Option Kit 5 5. Reconnect display ribbon cable and reinstall cover. ATTENTION: The cover screws must be securely tightened in order to properly ground the cover. Verify that all four cover screws are tight before applying power to the unit. Failure to observe this precaution could result in severe bodily injury or loss of life. NEMA 12 Enclosed Installation Use the cross-reference table below to verify that the correct filter has been selected for your CE compatible drive. Filter Selection Filter Catalog Number Series Ratings Use with Bulletin 1329I Series B Drive/Motor 1329I-JLF1 A 115/230 VAC Single Phase 14 Amps 1329I-BJ 1329I-BK 1329I-JLF3 A 230/460 VAC Three Phase 9 Amps 1329I-BL 1329I-BM Filter Enclosure Dimensions 29.0 (1.13) mm (in) 152.0 (6.0) 292.0 (11.5) 10.0 (0.38) 113.0 (4.46) 273.0 (10.75) 225.0 (8.87) 3.0 (0.10) 6 1329I Integrated Drive/Motor CE Filter Option Kit Filter Installation ATTENTION: To prevent electrical shock, disconnect the power source before installing or servicing. ATTENTION: The National Codes and standards (NEC, VDE, BSI, etc.) and local codes outline provisions for safely installing electrical equipment. Installation must comply with specifications regarding wire types, conductor sizes, branch circuit protection, and disconnect devices. Failure to do so may result in personal injury and/or equipment damage. 1. Mount the NEMA 12 Enclosed CE filter. The cable length from the filter to the drive/motor must be less than 3 meters (10 feet). 2. The RFI filter must be connected between the incoming AC supply line and the drive input terminals. Important: The filter may cause ground leakage currents. Therefore, a solid ground connection must be provided as shown on the following page. ATTENTION: To guard against possible equipment damage, RFI filters can only be used with AC supplies that are nominally balanced with respect to ground. In some installations, threephase supplies are occasionally connected in a 3-wire configuration with one phase grounded (Grounded Delta). The filter must not be used in Grounded Delta supplies. 1329I Integrated Drive/Motor CE Filter Option Kit 7 Filter Wiring CE Filter 1329I Integrated Drive/Motor L1 Conduit/4-Wire Cable L1' IN OUT L2 L2' L3 L3' PE PE OUT IN OUT IN R/L1 S/L2 T/L3 PE Nearest Building Structure Steel 3. Connect the wires to the CE filter as shown in the diagram below. (Three Phase unit shown.) 0.3-0.8 Nm (3-7 in-lb) 1.3 Nm (12 in-lb) 2.8 Nm (25 in-lb) L1 L2 L3 PE IN OUT Incoming AC Power To Integrated Drive/Motor AC Input Terminals Bulletin 1329I CE Filter Option Specifications 1329I-NLF1 1329I-NLF3 1329I-JLF1 1329I-JLF3 Input Voltage 115/230 VAC 230/460 VAC 115/230 VAC 230/460 VAC Input Phases Single Phase Three Phase Single Phase Three Phase Frequency 50/60 Hz Rated Current 14 Amps 9 Amps 14 Amps 9 Amps 4.72 Kg (10.41 lb) 4.89 Kg (10.78 lb) Power Dissipation 5 Watts Leakage Current (Worst Case) 0.5 mA Weight 0.33 Kg (0.73 lb) Enclosure 0.45 Kg (0.99 lb) Internal NEMA 12/IP 65 Operating Temperature 0° to 40°C (32° to 104°F) Storage Temperature -40° to 85°C (-40° to 185°F) Relative Humidity 5% to 95%, non-condensing Vibration 1 G operational, 2.5 G non-operational Shock 15 G operational, 30 G non-operational Altitude 1000 meters (3300 feet) without derating. For every 91.4 meters (300 feet) above 1000 meters, derate current by 1%. Above 3000 meters (10,000 feet), consult your Allen-Bradley Sales Office. International Standards and Approvals LIST ED 966X UL UL508C ® IN D Publication 1329I-5.4 – January, 2000 CONT EQ LIST ED 966X C UL CSA 22.2 ® IN D CONT EQ EMC Directive 89/336 LV: EN 50178, EN 60204 EMC: EN 61800-3, EN 50081-1, EN 50082-2 P/N 194395 (01) Copyright 2000 Rockwell International Corporation. Printed in USA ">
Advertisement