Fault Codes
Fault Code
Using the Local Operator Controls
Fault Description
Function Loss
Start the unit.
Press the green
High Bus Voltage
Stop the unit.
Press the red
Change motor
rotation direction.
Clear faults or abort
Auto Restart
sequence.
Low Bus Voltage
Overcurrent
Overtemperature
Overload
Internal Fault (where NNN = a number
from 0 to 999).
or
User Steps
Desired Action
Press the
key.
key.
key.
1329I
Integrated Drive/Motor
RESET
Press the
key.
Quick Reference
Press the
key until the
speed reference displayed
Decrease the speed is the desired value. The
reference.
longer the
key is held
down, the faster the value
will change.
Keypad Cable Disconnected
Press the
or
key once.
The display will return to indicating
speed in RPM or %load after three to
five seconds.
No action required; speed in RPM is
Display the speed in
the default display based on terminal
RPM.
12.
Display %load.
Close switch on terminal 12.
Display the current
speed or load.
Keypad Cable Connected
Setting the Operating Speed Before
Starting the Unit
Standard units: Use the speed potentiometer or
other user-supplied external speed reference
device.
Units with local operator controls: As shipped
from the factory, the unit receives its speed
reference from the keypad. Use the
key to
increase the speed reference and the
to decrease the speed reference.
key
Increase the speed
reference.
Press the
key until the
speed reference displayed is the
desired value. The longer the
key is held down, the faster the value
will change.
To use the analog input terminals for the speed
reference, setup switch 2 (Speed Reference
Select) must be in the ON position. In this case,
the
keys are not used.
At subsequent power ups, the unit will use the
last speed reference setting selected before
power was removed.
IMPORTANT: This publication is designed as a reference
tool. The 1329I User Manual (publication 1329I-5.0) must
be consulted for more detailed information operation and
hazards of personal injury.
Publication 1329I-5.1 – January, 1999
P/N 193376 (01)
Max Speed Switch (SW2)
ATTENTION: All adjustments to these components
should be made with the power removed. Failure to
observe this precaution could result in severe bodily
injury or loss of life.
Accel/Decel Switch (SW1)
0 = 1 Second Accel/5 Sec Decel
1 = 5 Seconds (Default)
2 = 10 Seconds
3 = 15 Seconds
4 = 20 Seconds
5 = 30 Seconds
6 = 60 Seconds
7 = 90 Seconds
0 = 1500 RPM (50 Hz)
1 = 1800 RPM (60 Hz) Default
2 = 2100 RPM (70 Hz)
3 = 2400 RPM (80 Hz)
4 = 2700 RPM (90 Hz)
5 = 3000 RPM (100 Hz)
6 = 3300 RPM (110 Hz)
7 = 3600 RPM (120 Hz)
ATTENTION: After disconnecting input power, wait
five minutes and check with voltmeter to assure that
DC bus capacitors are discharged (DC+, DC-).
The voltmeter should read zero volts.
Setup DIP Switch (SW3)
OFF ON
AC Input Power Connections
Enabled
Terminal Block
Run On Power Up
Speed Reference ➊
Disabled
Operator Controls
Relay Control Output
Running
Faulted
Auto Restart
Disabled
Enabled
Variable
Constant
Torque Curve
Reverse
S/L2
From Terminal Block
3 Hz
DBR (Do Not Wire)
T/L3
Disabled
Enabled
Minimum Speed
DBR
Ramp-to-Rest
Coast-to-Rest
DC Bus (Do Not Wire)
DC-
PE
Stop
DC+
AC Inputs
R/L1
Not Used
Not Used
= Default Setting (OFF Position)
➊ Switch 2 applies to local operator control units only.
Ground
Control Signal Terminal Block
Standard Unit
1
2
3
4
5
0 – 10 Volt Output
Common
6
Common
7
24 Volt DC ➋
7
24 Volt DC ➊
8
Speed Preset 2
8
Speed Preset 2
9 10 11 12 13 14 15 16 17 18 19 20
Speed Preset 1
9 10 11 12 13 14 15 16 17 18 19 20
Speed Preset 1
-
ATTENTION: The cover screws must be securely
tightened in order to properly ground the cover.
Verify that all four cover screws are tight before
applying power to the unit. Failure to observe this
precaution may result in severe bodily injury or loss
of life.
+
Speed Preset 0
Function Loss ➋
RPM/Percent Load Display
= N.O. Momentary Contact
24 Volt DC
= N.C. Momentary Contact
Forward/Reverse
% Load
= Maintained Contact - Closed
Reset
Start
RPM
= Maintained Contact - Open
13
Stop
24 Volt DC Common
N.O. Relay
Relay Common
16 17
Connect to external device.
Common
0 – 10 Volt Output
6
Momentary 3-Wire Start.
4 – 20 mA Speed Reference Input
Common
5
Rev
0 – 10V DC Speed Reference Input
4 – 20 mA Speed Reference Input
4
% Load
Fwd
10 Volt Reference
0 – 10V DC Speed Reference Input
3
RPM
5K Ω
+
10 Volt Reference ➊
2
-
1
+10V DC
Local Operator Control Unit
Maintained 2-Wire Start.
➊ An external 0 to 10 volt or 4 to 20 mA speed reference source can be connected.
See Section 7.5.3 of the User Manual for more information.
Connect to external device.
Speed Preset 0
Function Loss ➊
RPM/Percent Load Display
24 Volt DC
Forward/Reverse
Reset
Start
Stop
24 Volt DC Common
N.O. Relay
Relay Common
➋ The jumber between terminals 7 and 11 must be removed when wiring the Function Loss input.
See Section 7.1 of the User Manual for more information.
">