Allen-Bradley ARMORBLOCK INPUT Installation Instructions
Allen-Bradley ARMORBLOCK INPUT is a standalone 24V dc I/O module that communicates via a DeviceNet network. This model has 4 sinking inputs and is designed for industrial environments. It features a sealed housing that requires no enclosure and is tested to meet various safety directives, including EMC and Low Voltage.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions ArmorBlock LP2 4 Sinking Input Module (Cat. No. 1792D-4B0LP) I0 I3 I1 I2 Network Status Module Status 41621 This ArmorBlock LP2 I/O module (Cat. No. 1792D-4B0LP) is a standalone 24V dc I/O product which communicates via a DeviceNet network. The sealed housing of this module requires no enclosure. This model has 4 sinking inputs. Package Contents Your package contains: • 1 ArmorBlock LP2 Module • Installation Instructions . Publication 1792D-5.27- January 1999 2 ArmorBlock LP2 4 Sinking Input Module European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: • EN 50081-2 EMC - Generic Emission Standard, Part 2 - Industrial Environment • EN 50082-2 EMC - Generic Immunity Standard, Part 2 - Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: • Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1 • Automation Systems Catalog, publication B111 Install Your ArmorBlock LP2 I/O Module To install the module: • Set the node address and baud rate. • Mount the module. • Attach the block to the DeviceNet trunk. • Connect the cord sets. Set the Node Address Set the node address using RSNetworx for DeviceNet software, DeviceNetManager software, or another software configuration tool. The module is equipped with AutoBaud detect. AutoBaud lets the module read the settings already in use on your DeviceNet network and automatically adjusts to follow those settings. Publication 1792D-5.27- January 1999 ArmorBlock LP2 4 Sinking Input Module 3 Install the Module 1. Attach the module using the dimensions shown below. 1.95 in 49.5mm 12in 305mm I0 I3 I1 I2 Network Status 4.21 in 107mm Module Status 0.25 in 6.25mm 1.02 in 26.0mm 2. Connect the grey DeviceNet cable to the DeviceNet trunk. Use the 1485P-P1R5-MN5R1 T-Part tap to make the connection to round media. Use the 1485P-P1E4-R5 to connect to the Kwik Link flat media system. Connect the Input Cord Sets to the LP2 Module This module uses 5 pin micro (12mm) style PCB mounted connectors. Four micro caps cover the connectors on your module. Remove the caps and connect your cables to the appropriate ports. Use the micro caps to cover and seal unused ports. A Pinout diagram for the connector is shown next. 2 1 5 4 1 3 Input Micro-Connector (View into Sockets) Pin 1 Sensor Source Voltage Pin 2 Not Used Pin 3 Return Logic Ground1 Pin 4 Input A Pin 5 Not Used Logic Ground is approximately 0.4V above DeviceNet V-measured at the module. Publication 1792D-5.27- January 1999 4 ArmorBlock LP2 4 Sinking Input Module ATTENTION: ! • Make sure to connect the proper color coded cables together. DeviceNet cables should connect with DeviceNet cables. • Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP67 requirements • For maximum noise immunity, input and output cable return wires must be properly terminated. When inputs and outputs are connected in loopback, return wires should be connected together. • I/O cable length should be less than 30 meters. Input connectors for this module are shown below. I0 Connector A I3 Input 0 Connector D Input 3 I1 Connector B I2 Input 1 Connector C Input 2 Network Status Module Status 41461 DeviceNet Cable Refer to the DeviceNet Cable Planning and Installation Manual (DN-6.7.2) for more information on selecting the proper DeviceNet cable for your application. Publication 1792D-5.27- January 1999 ArmorBlock LP2 4 Sinking Input Module 5 Communicate With Your ArmorBlock LP2 Module This ArmorBlock module’s I/O is exchanged with the master through a poll, change of state, or cyclic connection. The module produces input data as follows: Type of I/O Connections Consumes Produces Cyclic 0 Byte 1 Byte Polled 0 Byte 1 Byte Change of State 0 Byte 1 Byte Cyclic - allows configuration of the block as an I/O client. The block will produce its I/O cyclically at the rate configured. Polled - a master initiates communication by sending its polled I/O message to the module. The 4 input module scans the inputs producing a response that reflects their status. Change of state - productions occur when an input changes . If no input change occurs within the expected packet rate, a heartbeat production occurs. This heartbeat production tells the scanner module that the module is alive and ready to communicate. Refer to the table below for the word/bit definitions. Bit 07 06 05 04 03 02 01 00 Produces 0 RSVD RSVD RSVD RSVD I3 I2 I1 I0 Where: O I = Input RSVD = Reserved Byte Bit Description 00-03 Input status bits: When the bit is set (1), the input is on. Bit 00 = input 0, bit 01= input 1, bit 02 = input 2, bit 03 = input 3. Reserved Produces 0 07 The DeviceNet Network uses advanced network technology, producer/ consumer communication, to increase network functionality and throughput. Visit our web site at http://www.ab.com/networks for producer/ consumer technology information and updates. Publication 1792D-5.27- January 1999 6 ArmorBlock LP2 4 Sinking Input Module Troubleshoot with the Indicators This module has the following indicators: • Network status indicator • Module status indicator • Individual point status indicators for inputs 0, 1, 2, and 3 Point indicator for input 0 Connector A I0 I3 Point indicator for input 3 Connector D Point indicator for input 1 Connector B I1 I2 Point indicator for input 2 Connector C DeviceNet Indicators Network Status Module Status LED Assignments Module Status Indicator Indication Status None No Power Green Blinking Solid Needs Commissioning Operating Normal Red Blinking Solid Recoverable Fault Unrecoverable Fault Network Status Indicator NS Indication Status None Not On-line Green Blinking Solid On-line/No Connections On-line/Connected Publication 1792D-5.27- January 1999 41461 7 ArmorBlock LP2 4 Sinking Input Module Red Blink Solid Connection Timed Out Failed Communication: A duplicate node address exists or module is at the wrong baud rate. I/O Status Indicators Function Module Status Indicator Point Indicator Condition Inputs Green Green None Yellow No valid input Valid input For more information on indications see the Product Data publication 1792-2.1. Specifications 4 Input Module - Cat. No. 1792D-4B0LP Sinking Input Specifications Max Min Inputs per block 4 - 3 wire or dry contact PNP devices Sensor Source Current (per input) 50mA - On-state Voltage 25V dc 10V dc On-state Current 10mA 2mA Off-state Voltage 5Vdc Off-state Current 1.5mA General Specifications Indicators Network Status - red/green Module Status - red/green Point LED- yellow Communication Rate • 125Kbps @ 500 meters(1600 feet) for thick cable, flat media length 375 meters (1230 feet) • 250Kbps @ 200 meters(600 feet) for thick cable, flat media length 150 meters (492 feet) • 500Kbps @ 100 meters (330 feet) for thick cable, flat media length 75 meters (246 feet) DeviceNet Power Voltage Current Dimensions (assembled to base) inches - (millimeters) 25V dc 125mA (no sensors) 300mA (full load) 1.023H x 2.7w x 4.72D (26)H x (68.5)W x (120)D Publication 1792D-5.27- January 1999 11V dc 8 ArmorBlock LP2 4 Sinking Input Module 4 Input Module - Cat. No. 1792D-4B0LP Sinking Input Specifications Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Max Min -25 to 60o (-13 to 140oF) -25 to 80oC (-13 to 176OF) Up to 100% 30g peak acceleration, 11 (+1) ms pulse width 50g peak acceleration, 11(+1)ms pulse width Tested 10g @ 10-500Hz per IEC 68-2-6 Publication DN-6.7.2 Enclosure Meets or exceeds IP67 Agency Certification (when product is marked) • CE marked for all applicable directives Product Data (user information) Publication 1792-2.1 This product has been tested at an Open DeviceNet Vendor Association, Inc. (ODVA) authorized independent test laboratory and found to comply with ODVA Conformance Test Software Composite Test Version 11. ArmorBlock, ArmorBlock LP2 and DeviceNetManager are trademarks of Rockwell Automation Publication 1792D-5.27- January 1999 PN 955134-79 1999 Rockwell International. All Rights Reserved. Printed in USA ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- DeviceNet Communication
- 4 Sinking Inputs
- Sealed Housing
- IP67 Rating
- AutoBaud Detect
- LED Indicators
- EMC and Low Voltage Compliant
Frequently asked questions
This ArmorBlock LP2 module has 4 sinking inputs.
This module uses 5 pin micro (12mm) style PCB mounted connectors. Remove the micro caps and connect your cables to the appropriate ports. Ensure all connectors and caps are securely tightened to maintain IP67 requirements.
The I/O cable length should be less than 30 meters.