Installation Instructions Installing Your 1394-CPDCP Power Plug This document illustrates the installation of the 1394-CPDCP and is used in conjunction with the 1394 Digital AC Multi-Axis Motion Control System User Manual (publication 1394-5.0). Use the 1394CPDCP to terminate the 1394-DCLM which provides additional capacitance for the 1394 system. Installing the Power Plug To install the power plug: 1. Locate the DC link power connector on the front underside of the 1394-DCLM. Figure 1 Locating the DC Link Power Connector DC Link Power Connector 2. Install the power plug to the DC link power connector using the provided screws (4M x 10) with 12-15in./lbs of torque. Figure 2 Installing the Power Plug Allen-Bradley 1394 Digital Servo Controller System Module DC Link Module Power Plug Screws Publication 1394-5.13 - September 1998 For more information refer to our web site: www.ab.com/motion For Rockwell Automation Technical Support information refer to: www.rockwellautomation.com/support or Tel: (1) 440.646.3434 Publication 1394-5.13 - September 1998 Copyright 1998 Allen-Bradley Company, Inc. 191840 Printed in USA ">