Allen-Bradley NEMA 1 Enclosure Kit Installation Instructions
Allen-Bradley 1336 FORCE is a powerful drive that offers precise control of AC induction motors. It's designed for demanding applications requiring high performance and reliability, such as conveyors, pumps, fans, and machine tools. With its advanced features like sensorless vector control, flux vector control, and Volts/Hz control, it delivers exceptional torque response, speed regulation, and efficiency. The 1336 FORCE also provides built-in protection against overloads, short circuits, and ground faults, ensuring the safety of your equipment.
PDF
Download
Document
Advertisement
Advertisement
Instructions 1336 PLUS, 1336 PLUS II & 1336 FORCE™ NEMA Type 1 Enclosure Kit 1336S/F/T-AAx and 1336S/F/T-AEx This publication will guide you through installation of an IP 20 (NEMA Type 1) Enclosure Kit (1336S/F/T-AAx) or EMC Enclosure Kit (1336S/F/T-AEx). Refer to the appropriate drive User Manual for further information. Enclosure Installation ! ! ! ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing or repairing this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference A-B publication 8000-4.5.2, “Guarding Against Electrostatic Damage” or any other applicable ESD protection handbook. ATTENTION: To avoid a shock hazard, assure that all power to the drive has been removed before proceeding with the following procedure. In addition, verify that the DC bus has discharged by measuring across the “+DC” and “–DC” terminals of TB1 with a voltmeter. The voltage should be 0.0VDC. ATTENTION: When a drive mounted HIM is not supplied on enclosed IP 20 (NEMA Type 1) drives, the blank cover plate (option HAB/HASB) must be installed to close the opening in the front cover of the enclosure. Failure to install the blank cover plate allows access to electrically live parts which may result in personal injury and/or equipment damage. When a drive mounted HIM is supplied with enclosed IP 20 (NEMA Type 1) drives, but has been removed from its mounting cradle for remote operation, the blank cover plate must be installed in place of the HIM. 2 Installation 1336 PLUS, 1336 PLUS II & 1336 FORCE™ NEMA Type 1 Enclosure Kit Access to the top, bottom and sides of the drive chassis is required to assemble the kit. If the open chassis drive is already installed, remove and lock-out all power to the drive, then label and disconnect all wiring. External wiring will have to be rerouted through enclosure knockouts once the kit has been installed. Figure 1 Enclosure Kits – 1336S/F-AA2 and -AA3 1. Mount the top, bottom and side plates to the chassis using the supplied screws. Tighten all screws to 1.7 N-m (15 lb.-in.). 2. Install the front cover by sliding it up, then down to engage the slots into the angled tabs. Swing the cover bottom “in” and secure it with the captive screw. Tighten to 0.7 N-m (6 lb.-in.). Figure 2 EMC Enclosure Kits – 1336S/F-AE2 and -AE3 1. Mount the bottom plate to the chassis using the supplied screws. 2. Slide enclosure assembly over the chassis as shown. 3. Fasten the assembly to the chassis using the supplied screws. Tighten all screws to 1.7 N-m (15 lb.-in.). Figure 3 Enclosure Kits – 1336S/F/T-AA4 and -AA5 1. Slide the side plates over the chassis tabs as shown. 2. Attach the top and bottom plates to the side plates by sliding the tabs into the corresponding slots. Fasten the assembly to the chassis using the supplied screws. Tighten all screws to 1.5 N-m (13 lb.-in.). 3. Install the front cover by sliding it up, then down to engage the slots into the angled tabs. Swing the cover bottom “in” and secure it with the captive screw. Tighten to 0.7 N-m (6 lb.-in.). Figure 4 EMC Enclosure Kits – 1336S/F/T-AE4 and -AE5 1. Mount the bottom plate to the chassis using the supplied screws. 2. 1336 PLUS II drives using the AE4 Enclosure Kit require replacement of a ribbon cable. Remove the ribbon cable between the Main Control Board and Gate Drive Board (see Figure 4). Replace this cable with the new supplied cable (with ferrite block). Position the cable/block as needed to prevent obstruction with the enclosure being installed. 3. Slide enclosure assembly over chassis as shown. 4. Fasten the assembly to the chassis using the supplied screws. Tighten all screws to 1.5 N-m (13 lb.-in.). 1336 PLUS, 1336 PLUS II & 1336 FORCE™ NEMA Type 1 Enclosure Kit Figure 1 1336S/F-AA2 & AA3 Enclosure Kits Figure 2 1336S/F-AE2 & AE3 EMC Enclosure Kits Replace Ribbon Cable (1336F-AE4 Only) Figure 3 1336S/F/T-AA4 & AA5 Enclosure Kits Figure 4 1336S/F/T-AE4 & -AE5 EMC Enclosure Kits 3 4 1336 PLUS, 1336 PLUS II & 1336 FORCE™ NEMA Type 1 Enclosure Kit Figure 5 Enclosure Kits – 1336S/F/T-AA6 and -AA7 EMC Enclosure Kits – 1336S/F/T-AE6 and -AE7 For CE conformance, the EMI gasket (pre-installed) and jumper (see below) supplied with the 1336S/F/T-AE6 & AE7 must be in place. 1. Slide the side plates over the chassis tabs as shown. 2. Attach the top and bottom plates to the side plates by sliding the tabs into the corresponding slots. Fasten the assembly to the chassis using the supplied screws. Tighten all screws to 2.8 N-m (25 lb.-in.). 3. Install the door on the side plate hinge pins. 4. For EMC Kits - locate the supplied jumper wire and fasten one end to the chassis ground stud. The other end must be fastened to the stud located in the lower corner of the door. Door Grounding Jumper Jumper must be Installed inside Enclosure between Enclosure Door (Grounding Stud) and Chassis Grounding Stud. Figure 5 1336S/F/T-AA6 & -AA7 Enclosure Kits 1336S/F/T-AE6 & -AE7 EMC Enclosure Kits Rockwell Automation helps its customers receive a superior return on their investment by bringing together leading brands in industrial automation, creating a broad spectrum of easy-to-integrate products. These are supported by local technical resources available worldwide, a global network of system solutions providers, and the advanced technology resources of Rockwell. Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Bolivia • Brazil • Bulgaria • Canada • Chile • China, People’s Republic of • Colombia • Costa Rica • Croatia • Cyprus Czech Republic • Denmark • Dominican Republic • Ecuador • Egypt • El Salvador • Finland • France • Germany • Ghana • Greece • Guatemala • Honduras • Hong Kong Hungary • Iceland • India • Indonesia • Iran • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Macau • Malaysia • Malta • Mexico Morocco • The Netherlands • New Zealand • Nigeria • Norway • Oman • Pakistan • Panama • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic of • Spain • Sweden • Switzerland • Taiwan • Thailand • Trinidad • Tunisia • Turkey • United Arab Emirates United Kingdom • United States • Uruguay • Venezuela Rockwell Automation Headquarters, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414 382-2000, Fax: (1) 414 382-4444 Publication 1336 PLUS-5.6 – July, 1998 Supersedes February, 1998 P/N 74001-008-01 (02) Copyright 1998 Rockwell International Corporation. All rights reserved. Printed in USA. ">
Advertisement