Allen-Bradley Dataliner 20 Message Display Installation Instructions
Allen-Bradley Dataliner 20 Message Display is a versatile industrial display designed for mounting within a panel or enclosure. It allows for clear communication of important information such as status updates, alarms, and process data. With its multiple display lines, you can showcase a variety of messages and parameters. The Dataliner 20 also supports various communication protocols, allowing for integration into your control systems.
PDF
Download
Document
Advertisement
Advertisement
Packing Data PK Installation Instructions This document describes how to install a Dataliner DL20 display in a panel or enclosure and connect power. • • • • • • • • European Union Directive Compliance wiring and safety guidelines enclosures required tools mounting dimensions clearances installing the DL20 display in a panel connecting AC power For more information on the Dataliner DL20 display, refer to the Dataliner DL20 User Manual (Publication 2706-814). 2 Dataliner DL20 Message Display European Union Directive Compliance If a Dataliner Message Display is installed within the European Union or EFTA regions and has a CE mark, the following regulations apply. EMC Directive This apparatus is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) using a technical construction file and the following standards in whole or in part. • EN 50081-2 • EN 50082-2 EMC – Generic Emission Standard, Part 2 Industrial Environment EMC – Generic Immunity Standard, Part 2 Industrial Environment Dataliner products are intended for use in an industrial environment. Low Voltage Directive This apparatus is tested to meet Council Directive 73/23/EEC Low Voltage (LVD) with amendments, including 93/68/EEC using the pertinent sections of the following standards. • EN 61131-2:1992 • EN 60950:1992 Programmable Controllers - Equipment Requirements and Tests Safety of Information Technology Equipment Intended Use of Product According to these Standards, the factor which determines, for EMC purposes, whether an apparatus is deemed to be “Industrial” or “Residential, commercial and light industrial”, is given in Clause 1 of EN50081-2 as follows: Dataliner DL20 Message Display 3 Apparatus covered by this standard is not intended for connection to a public mains network but is intended to be connected to a power network supplied from a high- or medium-voltage transformer dedicated for the supply of an installation feeding a manufacturing or similar plant. This product is intended for use solely in an industrial environment as defined above. When installed in Europe, any other application is in contravention of European Union Directives, and a breach of these laws. Wiring and Safety Guidelines Install the Dataliner DL20 display using publication 70E, Electrical Safety Requirements for Employee Workplaces. In addition to the NFPA general guidelines, follow these recommendations: • Connect the Dataliner display to its own branch circuit. The input power source should be protected by a fuse or circuit breaker rated at no more than 15 amps. • Route incoming power to the DL20 display by a separate path from the communications cable. • Where power and communication lines must cross, they should cross at right angles. Communications lines can be installed in the same conduit as low level DC I/O lines (less than 10 Volts). • Grounding minimizes noise from Electromagnetic Interference (EMI) and is a safety measure in electrical installations. To avoid EMI, shield and ground cables appropriately. • A source for grounding recommendations is the National Electrical Code published by the National Fire Protection Association of Boston. Enclosures Mount the DL20 display in a panel or enclosure to protect the internal circuitry. The display meets NEMA Type 12/13, 4 (indoor use), and 4X (for stainless steel faceplate versions) ratings only when properly mounted in a panel or enclosure with the equivalent rating. 4 Dataliner DL20 Message Display Allow enough space within the enclosure for adequate ventilation. Consider heat produced by other devices in the enclosure. The ambient temperature around the display must be between 0 and 60C (32 and 140F). Make provisions for accessing the back panel of the display for wiring, maintenance, and troubleshooting. Required Tools Other than the tools required to make the panel cutout, the tools required for installation are: • 3/8 inch deep well socket wrench • small slotted screwdriver • torque wrench (in. / lbs). Dataliner DL20 Message Display 5 Installing Display in Panel To install the Dataliner display: ATTENTION: Disconnect all electrical power from the panel before ! making cutout. Make sure the area around the panel cutout is clear. Take precautions so that metal cuttings do not enter any components that may already be installed in panel. Failure to follow this warning may result in personal injury or damage to the panel components. Mounting the DL20 The following figures provide panel cutout dimensions and overall dimensions for the DL20. You can mount the DL20 in a custom panel or enclosure. Dataliner enclosures Catalog Numbers 2706-NE1 (one- or two-line display) and 2706-NE2 (four-line display) are available When the DL20 is properly installed, the faceplate of the DL20 provides a NEMA Type 12/13 enclosure integrity. To install the DL20, perform the following steps: 1. Cut and drill the appropriate mounting holes in the enclosure or panel. 2. Remove the six mounting nuts from the hardware kit included with the DL20. 3. Position the DL20 in the panel or enclosure mounting hole. 4. Install and tighten the six nuts on the mounting studs to a torque of 14 in•lbs (1.6N•m) each. ! ATTENTION: Mounting nuts must be tightened to a torque of 14 inch-pounds to provide a proper seal and to prevent potential damage to the display. Allen-Bradley assumes no responsibility for water or chemical damage to the display or other equipment within the enclosure because of improper installation. 6 Dataliner DL20 Message Display Mounting Dimensions Figure 1 One- and Two-Line Dimensions Dimensions in Inches (Millimeters) 13.30 (337.8) 0.12 Typ. (3.2) Top View 0.72 (18.3) 6.65 (168.9) Six Mounting Studs 14.37 (365.0) DIM. ”A’’ SEE CHART DIM. ‘‘B’’ SEE CHART 4.38 (111.2) Front View Dimension A Dimension B One Line 1.25 (31.8) 10.12 (257.2 ) Two Line 1.70 (43.2) 8.81 (223.8) Display Type 0.125 (3.2) (GASKET THICKNESS) 0.099 (2.5) (PANEL THICKNESS) 0.62 (15.7) 3.13 (79.5) Side View 7.37 (187.2) 0.62 (15.7) Dataliner DL20 Message Display 7 Figure 2 Four-Line DL20 Dimensions Dimensions in Inches (Millimeters) 0.12 Typ. (3.0) 13.30 (337.8) 0.53 (13.5) 0.72 (18.3) Top View 6.65 (168.9) Six Mounting Studs 14.37 (365.0) 8.83 (224.3) 1.63 (41.4) 2.94 (74.7) 0.099 (2.5) (PANEL THICKNESS) 6.18 (157.0) Front View 7.37 (187.2 ) 0.53 (13.5) 0.125 (3.2) (GASKET THICKNESS) Side View 5.12 (130.0) 0.53 (13.5) 8 Dataliner DL20 Message Display Clearances Allow adequate clearances for mounting, air flow, maintenance, and wiring. See Figure 3. Figure 3 Minimum Mounting Clearances Side, Top and Bottom Clearances Leave 25 mm (1 in.) for Mounting and Air Flow Display Cutout Front View Leave 25 mm (1 in.) for Mounting and Air Flow Leave 38 mm (1.5 in.) for Mounting and Air Flow Leave 25 mm (1 in.) for Mounting and Air Flow Dataliner DL20 Message Display 9 Cutout Dimensions Figure 4 shows the required cut-out dimensions. Figure 4 Dimensions in Inches (Millimeters) One- and Two-Line DL20 Displays 0.19 (4.8) 13.87 (352.3) 6.94 (176.1) 3.50 (88.9) Cut Out 3.88 (98.4) 0.13 (3.1) 13.62 (345.9) Cut Out 0.25 (6.4) DIA. HOLE (6 PLACES) Four-Line DL20 Display 0.25 (6.4) DIA. HOLE (6 PLACES) 13.87 (352.3) 6.94 (176.1) 0.19 (4.8) 6.81 (173.0) 13.62 (345.9) Cut Out 5.30 (134.6) Cut Out 5.68 (144.3) 10 Dataliner DL20 Message Display EMI Power-Line Filters (EU Installations Only) DL20 displays intended for use in the European Union require a power-line filter. One line filter is required for each installed display. Two filter models are available. These filters are functionally identical, they differ only in termination style. Schaffner Part No. Termination Style FN 660-3/06 Fast-On (Spade) connectors FN 660-3/07 Wire leads Line filters are available from an authorized Schaffner distributor. Part Number (FN 660-3/07) 27mm (1.06 in.) 30mm (1.18 in.) 12 mm (0.47 in.) 65 mm (2.56 in.) 75 mm (2.95 in.) 85 mm (3.35 in.) Part Number (FN 660-3/06) 5.3 mm (0.21 in.) 54 mm (2.13 in.) When properly installed, power-line filters prevent interference currents in the power lines. Interference currents can affect other devices on the same power line and other nearby equipment. Connect the Dataliner message display to the power-line filter as shown in the following sections. Dataliner DL20 Message Display 11 Connecting AC Power The table below shows the electrical ratings for the Dataliner DL20 display. Type of Display Supply Voltage Power Consumption One and Two Line 100-240V ac, 50/60 Hz 30 VA maximum Four Line 100-240V ac, 50/60 Hz 45 VA maximum ! ATTENTION: The Dataliner DL20 display is designed for safe use when installed in a suitably rated NEMA Type 12, 13, 4X (indoor use only), IP54 or IP65 enclosure. ! ATTENTION: Do not apply power to the display until all wiring connections have been made. Failure to do so may result in electrical shock. Wiring Guidelines (EU Installations Only) 10 cm (4 in.) Maximum L1 To Dataliner AC Input L2N L1 L2N To AC Mains Supply For installations within the European Union use the following guidelines to minimize Radio Frequency Interference (RFI) and achieve maximum Electromagnetic Compatibility (EMC). • Follow all local safety regulations regarding proper grounding. 12 Dataliner DL20 Message Display • Output leads from the power-line filter to the Dataliner must be 10 cm (4 in.) or less. • Both Dataliner and power-line filter must be connected to a low impedance earth ground • All parts of the grounding system must be connected together with low impedance connections. Keep all ground connections as short as possible • Power-line filter must be connected to earth ground before connecting the power source. • Do not run signal wiring and power wiring in the same conduit. • When control or communication wires must cross, they should cross at an angle as close to 90 degrees as possible. • Follow Dataliner display shielded cable requirements as specified in the user manual. • Make sure cable shielding connections and terminations are connected as specified in the appropriate Dataliner User Manual. • Keep the filter line side leads well separated from the load side leads. Dataliner DL20 Message Display 13 Wiring Diagram The following diagram shows how to connect the power-line filter for installations within the European Union. For non-European Union installations, the power-line filter can be omitted. For all other wiring connections refer to the DL20 User Manual (Publication 2706-814). RS RS RS RS +12 422 422 232 232 VDC ETS ETS N.C.COM N.O. – + OUT IN GND OUT – + AC PWR +5 VDC OUT GND L1 L2N D9 D8 D7 D6 D5 D4 D3 D2 D1D0 MS1MS0 1 11A11B12 13 14 15 16 17 18 19 RELAY KY BD 2 SERIAL COMM PORT 3 4 5 6 7 8 PARALLEL INPUT PORT 9 10 11 10 cm (4 in.) Maximum LOAD FN 660 LINE FILTER LINE L1 L2N Fuse Type USA 1.25 amperes, 250V ac, Type MDL European 1.5 amperes, 250V ac, Type GMC 14 Dataliner DL20 Message Display AC Power Connections Connection 120/240V ac, 3 Wire U.S. Color Code 120/240V ac, 3 Wire European Harmonized Color Code L1 Black (Line) Brown (Line) L2N White (Neutral) Blue (Neutral) P.E. Green (Earth Ground) Green/Yellow (Protective Earth) Additional Information For additional information on communication port wiring and display configuration, refer to the Dataliner DL20 User Manual (Publication 2706-814). Dataliner DL20 Message Display Notes: 15 Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Brazil • Bulgaria • Canada • Chile • China, PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic • Denmark • Ecuador • Egypt • El Salvador • Finland • France • Germany • Greece • Guatemala • Honduras • Hong Kong • Hungary • Iceland • India • Indonesia • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Malaysia • Mexico • Netherlands • New Zealand • Norway • Pakistan • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia–CIS • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • United Arab Emirates • United Kingdom • United States • Uruguay • Venezuela • Yugoslavia Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 41061-016-01(B) Copyright 1999 Allen-Bradley Company, Inc. Printed in USA ">
Advertisement
Key features
- Multiple display lines
- NEMA Type 12/13, 4 & 4X rated
- Supports communication protocols
- Customizable display content
- Easy mounting
Frequently asked questions
The mounting dimensions depend on the display type (one/two-line or four-line). You can find the specific dimensions in figures 1 and 2 of the viewed document.
The wiring procedure depends on your location. For installations within the European Union, you need to use a power-line filter and follow specific guidelines. The viewed document provides details on wiring for both EU and non-EU installations.
The Dataliner 20 display can operate within an ambient temperature range of 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit). Ensure you provide adequate ventilation within the enclosure to maintain this temperature range.