ezFIT 90 Gallon 199,000 BTU Atmospheric Commercial Gas Water Heater Specification Sheet

ezFIT 90 Gallon 199,000 BTU Atmospheric Commercial Gas Water Heater Specification Sheet
ezFIT
COMMERCIAL ATMOSPHERIC GAS WATER HEATERS
FIVE-YEAR LIMITED WARRANTY
the industry’s finest commercial protection
 90 gallon capacity
199,000 BTUH
Natural gas or propane burner
120°F to 180°F adjustable electronic thermostat
Electronic ignition
Automatic damper
Water jet sediment reduction side inlet
Clean out port
Optional Leg Extension Kit lifts water heater to
NSF-5 standard

insulation
- Does not contribute to global warming
Turboflue®
heat exchanger
Energy-Saving Turbofins conduct more
heat into water
Robust single-flue design yields a stronger, more durable tank
We take water heaters very personally!
ezFIT
This product is available from:
H
HOT
G
C
A
COLD
B
D
HOT
COLD
E
F
Model
EZ90-199N
Dimensions in Inches (cm)
Recovery 1st Hr.
Rated @ 100°F Del. @
Storage Input
Rise
100°F
A
B
C
D
E
F
G
H
GAL BTU/HR GAL/HR
Rise
(L)
(kW)
(L/HR) GAL (L)
90
199,000
191
263
78.00 70.25 26.00 62.75 18.00 9.00 16.00 6.00
(340.69) (58.32) (723.01) (995.56) (198.12) (178.44) (66.04) (159.39) (45.72) (22.86) (40.64) (15.24)
Aux. Inlet Outlet Gas Shipping
Conn. Conn. Conn. Conn. Weight
Dia. Dia. Dia. Dia.
LBS
NPT NPT NPT NPT
(kg)
485
1.50 1.50 1.50 0.75*
(219.99)
For LP models change suffix “N” to “LP”
*LP Gas valve - .50 NPT
Working Pressure: 150 psi (1034 kPa)
Test Pressure: 300 psi (2068 kPa)
Standard Voltage required: 120V, 60Hz, 1P
For natural gas: manifold pressure = 3.5” w.c. (0.87 kPa); Inlet pressure range = 5 - 14” w.c. (1.25-3.49 kPa)
For propane gas: manifold pressure = 10” w.c. (2.49 kPa); Inlet pressure range = 12 - 14” w.c. (2.99-3.49 kPa)
T&P valve factory installed
All Bock products meet or exceed current ASHRAE standards.
These products are design certified by UL (Underwriters Laboratories) and meet ANSI Z21.10.3/CSA 4.3 requirements for operation up
to 180°F (82°C).
Approved for use as an automatic storage water heater.
Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the
absence of local codes, refer to NFPA 54, ANSI Z21.10.3, or CSA B149.1.
Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F (49°C). Bock recommends a
tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.
www.bockwaterheaters.com
110 South Dickinson Street , Madison, Wisconsin 53703
Toll Free 800-794-2491 • Phone 608-257-2225 • Fax 608-257-5304
Doc# 80018-90 Rev. 11/13
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project