PLANET IGS-10020PT Quick guide
Planet IGS-10020PT is an Industrial 8-Port 10/100/1000T 802.3af PoE + 2-Port 100/1000X SFP Managed Switch. It provides a cost-effective, user-friendly solution for industrial automation networking applications that require high bandwidth and long-distance transmission, and supports stable data transmission and PoE power over existing Ethernet cables. With its robust metal case and wide operating temperature range of -40 to 75 degrees C, the IGS-10020PT can be placed in almost any difficult environment.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Industrial L2+ Multi-Port Full Gigabit
Managed Ethernet Switch
IGS-10020MT/IGS-10020PT/HPT/IGS-10080MFT
IGS-12040MT/IGS-20040MT/IGS-20160HPT
Quick Installation Guide
Table of Contents
1. Package Contents
Thank you for purchasing PLANET L2+ Industrial Managed Switch, IGS-10020 series, IGS-10080MFT, IGS-12040MT, IGS-20040MT or IGS-20160HPT The descriptions of these models are as follows:
IGS-10020MT
IGS-10020PT
IGS-10020HPT
IGS-10080MFT
IGS-12040MT
IGS-20040MT
IGS-20160HPT
Industrial 8-Port 10/100/1000T +
2-Port 100/1000X SFP Managed Switch
Industrial 8-Port 10/100/1000T 802.3af PoE +
2-Port 100/1000X SFP Managed Switch
Industrial 8-Port 10/100/1000T 802.3af/at PoE +
2-Port 100/1000X SFP Managed Switch
Industrial 8-Port 100/1000X SFP +
2-Port 10/100/1000T Managed Switch
Industrial 8-Port 10/100/1000T +
4-Port 100/1000X SFP Managed Switch
Industrial 16-Port 10/100/1000T +
4-Port 100/1000X SFP Managed Switch
Industrial 16-Port 10/100/1000T 802.3at PoE +
2-Port 10/100/100T + 2-Port 100/1000X SFP Managed
Switch
“Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the above seven models.
3
Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items: z
The Industrial Managed Switch x 1 z
Quick Installation Guide x 1 z
DIN Rail Kit x 1 z
Wall Mounting Kit x 1 z
DB9 to RJ45 Interface RS232 Console Cable x 1
(Only IGS-10020MT doesn’t have console interface) z
Dust Cap (Please refer to the table below)
IGS-10020MT
IGS-10020PT
RJ45 Dust Cap
8
9
SFP Dust Cap
2
2
IGS-10020HPT
IGS-10080MFT
IGS-12040MT
IGS-20040MT
IGS-20160HPT
9
3
9
17
19
2
8
4
4
2
If any of these are missing or damaged, please contact your dealer immediately. If possible, retain the carton including the original packing materials to enable you to repack the product in case there is a need to return it to us for repair.
4
2. Requirements
The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management:
Workstation is installed with Ethernet NIC (Network Interface Card)
Choice of Internet browsers includes Windows XP/2003, Vista, Windows 7,
Windows 8, Windows 10, MAC OS X, Linux, Fedora, Ubuntu or other platforms compatible with TCP/IP protocols.
z
The above workstation is installed with Web browser and JAVA runtime environment plug-in.
Ethernet Port connection z
Use standard network (UTP) cables with RJ45 connectors.
Note
It is recommended to use Internet Explore 7.0 or above to access the Industrial Managed Switch.
5
3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates a DC inlet power socket and consists of one terminal block connector within 6 contacts. Please follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1, or 5, and 6 for Power 2.
IGS-10020MT: DC 12~48V, AC 24V
6
Input
DC 12V~48V, AC 24V
V1- V1+
PWR1 Fault
V2- V2+
PWR2
Figure 3-1: IGS-10020MT Upper Panel
IGS-10020PT/IGS-10020HPT: DC 48V
DI 0 DI 1 DO 0 DO 1 GND GND
V1+ V11A@24V V2- V2+
DC1 Fault
Input DC 48V
DC2
Figure 3-2: IGS-10020PT/IGS-10020HPT Upper Panel
IGS-10080MFT: DC 12~48V, AC 24V
V2- V2+ V1- V1+
1A@24V
PWR2 Fault PWR1
Input DC 12V~48V
Figure 3-3: IGS-10080MFT Upper Panel
IGS-12040MT: DC 12~72V, AC 24V
DC2 Fault DC1 Input DC 12-72V
AC 24V
GND
GND
DO 1 DI 0 DI 1 DO 0
Figure 3-4: IGS-12040MT Upper Panel
7
8
IGS-20040MT: DC 12~48V, AC 24V
DI 0 DI 1 DO 0 DO 1 GND GND
DC1 Fault
Input DC 12-48V
AC 24V
DC2
Figure 3-5: IGS-20040MT Upper Panel
IGS-20160HPT: DC 48~56V
DI 0 DI 1 DO 0 DO 1 GND GND
DC1
Fault
Input DC 48-56V
DC2
Figure 3-6: IGS-20160HPT Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loosening.
IGS-10020MT
IGS-10020PT
IGS-10020HPT
IGS-10080MFT
IGS-12040MT
IGS-20040MT
IGS-20160HPT
1 2
Power 1
3 4
Positive (+) Pin
Pin 2/6
Pin 1/6
Pin 1/6
Pin 1/5
Pin 1/5
Pin 1/5
Pin 1/5
5 6
Power 2
Negative (-) Pin
Pin 1/5
Pin 2/5
Pin 2/5
Pin 2/6
Pin 2/6
Pin 2/6
Pin 2/6
Note
The wire gauge for the terminal block should be in the range from
12 to 24 AWG.
9
4. Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Managed
Industrial Switch. The console port of the Industrial Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of null modem.
IGS Industrial Managed Switch
PC/Workstation with
Terminal emulation software
IP Address:
192.168.0.100
RJ45 to DB9 RS232 Cable
Serial Port
A terminal program is required to make the software connected to the IGS
Industrial Managed Switch. Windows’ Hyper Terminal program may be a good choice. The Hyper Terminal can be accessed from the Start menu.
1. Click START, then Programs, Accessories and then Hyper Terminal.
2. When the following screen appears, make sure that the COM port should be configured as:
Baud: 115200
Parity: None
Data bits: 8
Stop bits: 1
Flow Control: None
10
5. Logon to the Console
Once the terminal has been connected to the device, power on the Industrial
Managed Switch and the terminal will display “running testing procedures”.
1. There are six switches with RJ45 type console connector. (IGS-
10020PT, IGS-10020HPT, IGS-10080MFT, IGS-12040MT, IGS-
20040MT and IGS-20160HPT)
2. Let’s take IGS-20040MT for example.
Note
When the following dialog box shown in Figure 5-1 appears, please enter the factory default user name “admin” and password “admin”.
User name: admin
Password: admin
Figure 5-1: Console Login screen
Note
1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under console interface.
11
6. Configuring IP address
The Industrial Managed Switch is shipped with default IP address shown below:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Switch, please use the procedures as follows:
Display of the current IP Address
1. At the “#” prompt, enter “show ip interface brief”.
2. The screen displays the current IP address shown in Figure 6-1.
Figure 6-1: IP Information Screen
12
Configuration of the IP Address
3. At the “#” prompt, enter the following command and press <Enter> as shown in Figure 6-2.
IGS-20040MT# configure terminal
IGS-20040MT (config)# interface vlan 1
IGS-20040MT (config-if-vlan)# ip address 192.168.1.100 255.255.255.0
The previous command would apply the following settings for the Industrial
Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
Figure 6-2: Configuring IP Address Screen
4. Repeat step 1 to check if the IP address has changed.
13
Store the current switch configuration
5. At the “#” prompt, enter the following command and press <Enter>.
# copy running-config startup-config
Figure 6-3: Saving Current Configuration Command Screen
If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the
Industrial Managed Switch through the new IP address.
Note
If you are not familiar with the console command or the related parameter, enter “help” anytime in console to get the help description.
14
7. Starting Web Management
The following shows how to start up the Web Management of the Industrial
Managed Switch. Note the Industrial Managed Switch is configured through an
Ethernet connection. Please make sure the manager PC must be set on the same
IP subnet address.
For example, the default IP address of the Industrial Managed Switch is
192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0.
IGS Industrial Switch
RJ45/UTP-Cable
IP Address:
192.168.0.x
IP Address:
192.168.0.100
Figure 7-1: IP Management Diagram
Logging in the Industrial Managed Switch
1. Use Internet Explorer 7.0 or above for Web browser and enter IP address
http://192.168.0.100 (the factory-default IP address) to access the Web interface.
2. When the following dialog box appears, please enter the default user name
“admin” and password “admin” (or the password you have changed before) as shown in Figure 7-2.
Default IP Address: 192.168.0.100
Default User Name: admin
Default Password: admin
Figure 7-2: Login Screen
15
3. After entering the password, the main screen appears as shown in Figure 7-3.
Figure 7-3: Web Main Screen of Industrial Managed Switch
4. The Switch Menu on the left of the Web page lets you access all the functions and status the Industrial Managed Switch provides.
Now, you can use the Web management interface to continue the Switch management. Please refer to the user manual for more.
Note
For security reason, please change and memorize the new password after this first setup.
16
8. Resetting the Switch to Default
To reset the IP address to the default IP Address “192.168.0.100” and the user password to factory default mode (default password is admin), press the hardware reset button on the front panel for about 10 seconds. After the device is rebooted, you can login the management Web interface within the same subnet of
192.168.0.xx and default password. Be noted that all the previous setups will be disappeared after the factory default reset is made.
P1 P2 FAULT
Ring R.O.
9
9 10
1000 LNK/ACT 1000 LNK/ACT
LNK
ACT
Mini-
GBIC
10
100/1000X SFP
Reset Button
RESET
LNK
1000
ACT
Figure 8-1: IGS-10020MT Reset Button
Reset Button
Console
9
P1 P2 FAULT
Ring R.O.
115200,N,8,1
9 10
1000 LNK/ACT 1000 LNK/ACT
LNK
ACT
10
100/1000X SFP
RESET
LNK ACT
PoE In-Use
7
5 6
3 4
1 2
802.3at PoE
10/100/1000T
IGS-10020HPT
17
18
Reset Button
Figure 8-3: IGS-10080MFT Reset Button
7
5
8
6
Reset Button
3
1
4
2
1000 LNK ACT
100 LNK ACT
IGS-12040MT
RESET
Figure 8-4: IGS-12040MT Reset Button
Reset Button
1
RESET
3
5
2
P1 P2
Ring R.O.
FAULT
4
6
Console
17
Figure 8-5: IGS-20040MT Reset Button
802.3at PoE+
5
7
1
3
2
P1 P2 FAULT
Ring R.O.
4
Console
RESET
6
17
8
Reset Button
18
9 10
11 12
Figure 8-6: IGS-20160HPT Reset Button
13 14
100 LNK
1000 LNK
ACT
ACT
15 16
20
LNK ACT
PoE In-use
IGS-20160HPT
19
9. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQ : http://www.planet.com.tw/en/support/faq.php
Switch support team mail address : [email protected]
IGS-10020MT/IGS-10020PT/IGS-10020HPT/IGS-10080MFT/IGS-12040MT/IGS-
20040MT/IGS-20160HPT User’s Manual: http://www.planet.com.tw/en/support/download.php?type1=22153&model=&type=3
(Please select your switch model name from the Product Model drop-down menu)
Copyright © PLANET Technology Corp. 2016.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
20
advertisement
Key Features
- 8-Port 10/100/1000T 802.3af PoE + 2-Port 100/1000X SFP
- Industrial-grade rugged metal case
- -40 to 75 degrees C wide operating temperature
- Supports stable data transmission and PoE power over Ethernet cables
- Compact and fanless design