- No category
advertisement
E N R A C 5 0 0
M i ic r ro E i is i io n s M o i it to i in g S y st e m
BLUETOOTH
WIRELESS
C o m b u s t i i b l l e s
D
( r
C
N
O
O
2 2
O
N O
N
N
O
O
2
X
2
X
S O
2 a f t
A N E W G E N E R A T I I I O N I I I N C O M B U S T I I I O N A N D E M I I I S S I I I O N S M O N I I I T O R I I I N G
The ENERAC 500 is everything you ever wanted in a low-cost, easy-to-use emissions monitoring system
RUGGED COMPREHENSIVE
• Heavy Duty Aluminum Case
• Simple Modular Design
• 2 Year Warranty
• Download Latest Firmware
Upgrades from our Website
• No-charge Loaners Available
• Basic O
2
-Efficiency Analyzer
• CO, Combustibles & Draft options
• Expandable Emissions Package
• Built-in Printer
• Palm and WindowsCE Software
• Buy Only What You Need
• Reduce Testing Costs
• Reduce Energy Costs
• Receive a Generous Trade-in
Allowance on your old analyzer
)
2
( H C s t
)
The ENERAC™ 500 is a low-cost micro-emissions monitoring system utilizing large electrode-area, filtered electro-chemical sensors. It is designed to help you meet the challenges of a rapidly changing regulatory environment. It is easy to use, comprehensive (NO-NO
2
-SO
2
-CO-O
2
-Comb) and flexible.
Equally at home with a simple combustion test, or with the monitoring of more sophisticated emissions reduction systems, the ENERAC™ 500 is designed to provide years of trouble-free service. It is flexible enough to be tailored to meet your specific needs yet simple enough to be completely maintained in the field. Simple design, rugged construction and an impressive array of options are its hallmark. Designed as a field workhorse, the ENERAC™ 500 can be upgraded at any time to meet your changing needs.
The ENERAC™ 500 provides a comprehensive range of automatic emissions calculations (Grams/Brake Horsepower
Hour, Pound/Million BTU), advanced ENERCOM™
Windows® software, two-way communications, and factory support. From low NO
X
burners (0.1 ppm NO
X
resolution) to large rich-burn engines (5000 ppm NO
X
/20,000 ppm CO), the
ENERAC™ 500 is designed to help you meet your monitoring needs at an affordable price.
MEASURED PARAMETERS RANGE RESOLUTION ACCURACY
1. AMBIENT TEMPERATURE
2. STACK TEMPERATURE
3. OXYGEN (O
2
)
Electrochemical Cell, 2 Years
4. CARBON MONOXIDE (CO)
Electrochemical Cell, 2 Years
5. NITRIC OXIDE (NO)
Electrochemical Cell, 2 Years
6. NITROGEN DIOXIDE (NO
2
)
Electrochemical Cell, 2 Years
7. SULFUR DIOXIDE (SO
2
)
Electrochemical Cell, 2 Years
8. COMBUSTIBLES
Catalytic Sensor
9. STACK DRAFT
10. SMOKE TEST
COMPUTED PARAMETERS
1. COMBUSTION
EFFICIENCY
2. CARBON DIOXIDE
0-150
°F
0-2000
°F
(1100
°C)
0-25%
0-2000 or
0-20000
PPM
0-300
0-2000 or
0-4000 PPM
0-500 or
0-1000 PPM
1
1
°F or C
°F or C
0.1%
1 PPM
0.1 PPM
1 PPM
1 PPM
0-2000 PPM 1 PPM
0-4%
+10” to –40”
WC
RANGE
0-100%
0-40%
0.1%
0.1” WC
0.1%
0.1%
3
°F
5
°F
0.2%
4%
4%
4%
4%
10% (CH
4
)
5%
ASTM method D2156
RESOLUTION ACCURACY
1%
5%
3. EXCESS AIR 0-1000% 1% 10%
4. OXIDES OF NITROGEN
(NO
X
)
5. POUNDS / MILLION BTU
(CO, NO, NO
2
, SO
2
)
6. GRAMS / BRAKE-HP-HR
(CO, NO, NO
2
, SO
2
)
0-3000 or
0-5000 PPM
0-99.99 #/B
0. 1 PPM
1 PPM
0.01 #/B
0-99.99GBH 0.01 GBH
4%
5%
5%
STANDARD FEATURES OPTIONAL FEATURES
NOTE: Emissions readings in PPM can be adjusted to any oxygen reference. (Oxygen correction factor for emissions adjustable 0-20% in 1% steps plus TRUE.)
1-800-695-3637
67 Bond Street, Westbury, NY 11590
(516) 997-2100 • FAX: (516) 997-2129
E-mail: [email protected] • www.enerac.com
MODEL 500 SPECIFICATIONS
PHYSICAL:
1. CASE: 9.75” x 4” x 2.75”
Aluminum case. Weight: 3 lbs.
2. PROBE: 9” L x 3.8” OD
Inconel steel stack probe.
Probe housing connects to instrument via a 10 ft. Viton hose and water trap or
Teflon hose and thermoelectric condenser.
Maximum continuous temperature: 2000 F.
ELECTRICAL POWER:
1. BATTERY: 4-6 VDC.
Rechargeable NiMH
(included) or 4 disposable
AA alkaline cells. Approx.
6-8 hours operating time
(1.5 hours with T’cooler)
2. AC: 120V, 60 Hz std.
(220V, 50 Hz optional), using battery charger with
NiCd/NiMH cells.
DISPLAY:
Four line by 16 character Liquid
Crystal Display with backlight
ENERCOM WINDOWS SOFTWARE
ENERAC 500 PRINTOUT
ENERAC M500
Serial #: 000000
Company Name
Time: 12:00:00
Date: 01/31/03
Fuel: #2 OIL
Effic: 79.5 %
Amb Temp: 75 F
Stack T: 425 F
Oxygen: 6.0 %
CO: 490 PPM
CO2: 11.2 %
Combust: 0.2 %
Draft: 3.5 "
Ex.Air: 37 %
NO: 325 PPM illumination.
PRINTER:
Internal 2” thermal printer.
NO2: 60 PPM
NOX: 385 PPM
SO2: 40 PPM
DATA STORAGE:
Internal: 100 individually selectable buffers hold one complete set of
Oxygen Ref:TRUE measurements each in non-volatile memory. Buffer contents can be sent to printer or serial port. Data is stored by pressing the STORE key or automatically on a periodic basis.
COMMUNICATIONS:
Serial Port (RS-232C port) settings: 9600,N,8,1
Bluetooth Wireless Serial Port: Class 1 - Maximum Range 100m
Optional Internal Modem
Enercom software for Windows (9x/ME/XP/NT/2000) available.
EnercomCE software for Pocket PCs running Windows Mobile.
EnerPalm software for PalmOS.
FUELS:
15 Fuels: #2 Oil, #4 Oil, #6 Oil, Natural Gas, Anthracite, Bituminous,
Lignite, Wood (50% H
2
O), Wood (0% H
2
O), Kerosene, Propane,
Butane, Coke Oven Gas, Blast Furnace & Sewer Gas.
Custom fuels available on request or by customer programming using
ENERCOM software.
MADE IN THE USA
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project