Enerac 500 Brochure

Add to my manuals
2 Pages

advertisement

Enerac 500 Brochure | Manualzz

E N R A C 5 0 0

M i ic r ro E i is i io n s M o i it to i in g S y st e m

BLUETOOTH

WIRELESS

C o m b u s t i i b l l e s

D

( r

C

N

O

O

2 2

O

N O

N

N

O

O

2

X

2

X

S O

2 a f t

A N E W G E N E R A T I I I O N I I I N C O M B U S T I I I O N A N D E M I I I S S I I I O N S M O N I I I T O R I I I N G

The ENERAC 500 is everything you ever wanted in a low-cost, easy-to-use emissions monitoring system

RUGGED COMPREHENSIVE

• Heavy Duty Aluminum Case

• Simple Modular Design

• 2 Year Warranty

• Download Latest Firmware

Upgrades from our Website

• No-charge Loaners Available

• Basic O

2

-Efficiency Analyzer

• CO, Combustibles & Draft options

• Expandable Emissions Package

• Built-in Printer

• Palm and WindowsCE Software

• Buy Only What You Need

• Reduce Testing Costs

• Reduce Energy Costs

• Receive a Generous Trade-in

Allowance on your old analyzer

)

2

( H C s t

)

The ENERAC™ 500 is a low-cost micro-emissions monitoring system utilizing large electrode-area, filtered electro-chemical sensors. It is designed to help you meet the challenges of a rapidly changing regulatory environment. It is easy to use, comprehensive (NO-NO

2

-SO

2

-CO-O

2

-Comb) and flexible.

Equally at home with a simple combustion test, or with the monitoring of more sophisticated emissions reduction systems, the ENERAC™ 500 is designed to provide years of trouble-free service. It is flexible enough to be tailored to meet your specific needs yet simple enough to be completely maintained in the field. Simple design, rugged construction and an impressive array of options are its hallmark. Designed as a field workhorse, the ENERAC™ 500 can be upgraded at any time to meet your changing needs.

The ENERAC™ 500 provides a comprehensive range of automatic emissions calculations (Grams/Brake Horsepower

Hour, Pound/Million BTU), advanced ENERCOM™

Windows® software, two-way communications, and factory support. From low NO

X

burners (0.1 ppm NO

X

resolution) to large rich-burn engines (5000 ppm NO

X

/20,000 ppm CO), the

ENERAC™ 500 is designed to help you meet your monitoring needs at an affordable price.

MEASURED PARAMETERS RANGE RESOLUTION ACCURACY

1. AMBIENT TEMPERATURE

2. STACK TEMPERATURE

3. OXYGEN (O

2

)

Electrochemical Cell, 2 Years

4. CARBON MONOXIDE (CO)

Electrochemical Cell, 2 Years

5. NITRIC OXIDE (NO)

Electrochemical Cell, 2 Years

6. NITROGEN DIOXIDE (NO

2

)

Electrochemical Cell, 2 Years

7. SULFUR DIOXIDE (SO

2

)

Electrochemical Cell, 2 Years

8. COMBUSTIBLES

Catalytic Sensor

9. STACK DRAFT

10. SMOKE TEST

COMPUTED PARAMETERS

1. COMBUSTION

EFFICIENCY

2. CARBON DIOXIDE

0-150

°F

0-2000

°F

(1100

°C)

0-25%

0-2000 or

0-20000

PPM

0-300

0-2000 or

0-4000 PPM

0-500 or

0-1000 PPM

1

1

°F or C

°F or C

0.1%

1 PPM

0.1 PPM

1 PPM

1 PPM

0-2000 PPM 1 PPM

0-4%

+10” to –40”

WC

RANGE

0-100%

0-40%

0.1%

0.1” WC

0.1%

0.1%

3

°F

5

°F

0.2%

4%

4%

4%

4%

10% (CH

4

)

5%

ASTM method D2156

RESOLUTION ACCURACY

1%

5%

3. EXCESS AIR 0-1000% 1% 10%

4. OXIDES OF NITROGEN

(NO

X

)

5. POUNDS / MILLION BTU

(CO, NO, NO

2

, SO

2

)

6. GRAMS / BRAKE-HP-HR

(CO, NO, NO

2

, SO

2

)

0-3000 or

0-5000 PPM

0-99.99 #/B

0. 1 PPM

1 PPM

0.01 #/B

0-99.99GBH 0.01 GBH

4%

5%

5%

STANDARD FEATURES OPTIONAL FEATURES

NOTE: Emissions readings in PPM can be adjusted to any oxygen reference. (Oxygen correction factor for emissions adjustable 0-20% in 1% steps plus TRUE.)

1-800-695-3637

67 Bond Street, Westbury, NY 11590

(516) 997-2100 • FAX: (516) 997-2129

E-mail: [email protected] • www.enerac.com

MODEL 500 SPECIFICATIONS

PHYSICAL:

1. CASE: 9.75” x 4” x 2.75”

Aluminum case. Weight: 3 lbs.

2. PROBE: 9” L x 3.8” OD

Inconel steel stack probe.

Probe housing connects to instrument via a 10 ft. Viton hose and water trap or

Teflon hose and thermoelectric condenser.

Maximum continuous temperature: 2000 F.

ELECTRICAL POWER:

1. BATTERY: 4-6 VDC.

Rechargeable NiMH

(included) or 4 disposable

AA alkaline cells. Approx.

6-8 hours operating time

(1.5 hours with T’cooler)

2. AC: 120V, 60 Hz std.

(220V, 50 Hz optional), using battery charger with

NiCd/NiMH cells.

DISPLAY:

Four line by 16 character Liquid

Crystal Display with backlight

ENERCOM WINDOWS SOFTWARE

ENERAC 500 PRINTOUT

ENERAC M500

Serial #: 000000

Company Name

Time: 12:00:00

Date: 01/31/03

Fuel: #2 OIL

Effic: 79.5 %

Amb Temp: 75 F

Stack T: 425 F

Oxygen: 6.0 %

CO: 490 PPM

CO2: 11.2 %

Combust: 0.2 %

Draft: 3.5 "

Ex.Air: 37 %

NO: 325 PPM illumination.

PRINTER:

Internal 2” thermal printer.

NO2: 60 PPM

NOX: 385 PPM

SO2: 40 PPM

DATA STORAGE:

Internal: 100 individually selectable buffers hold one complete set of

Oxygen Ref:TRUE measurements each in non-volatile memory. Buffer contents can be sent to printer or serial port. Data is stored by pressing the STORE key or automatically on a periodic basis.

COMMUNICATIONS:

Serial Port (RS-232C port) settings: 9600,N,8,1

Bluetooth Wireless Serial Port: Class 1 - Maximum Range 100m

Optional Internal Modem

Enercom software for Windows (9x/ME/XP/NT/2000) available.

EnercomCE software for Pocket PCs running Windows Mobile.

EnerPalm software for PalmOS.

FUELS:

15 Fuels: #2 Oil, #4 Oil, #6 Oil, Natural Gas, Anthracite, Bituminous,

Lignite, Wood (50% H

2

O), Wood (0% H

2

O), Kerosene, Propane,

Butane, Coke Oven Gas, Blast Furnace & Sewer Gas.

Custom fuels available on request or by customer programming using

ENERCOM software.

MADE IN THE USA