A
B
N
i
FEATURES:
ENGLISH
•
•
•
•
•
•
•
•
•
•
Part C –Wireless Outdoor Sensor
C1: Wireless Outdoor Sensor battery
compartment
Time in optional 12/24 hour format.
Daily Alarm Function
Snooze function(OFF or 1~60min)
Low battery indicate
Humidity: Indoor & Outdoor measurable
range: 20%RH ~ 95%RH
Temperature:
— Indoor temperature measurement ranges:
-9.9°C (14.2°F) ~ 50°C (122°F)
— Outdoor temperature measurement
ranges: -25°C (-13°F) ~ 50°C (122°F)
— Temperature alternatively in °C or °F.
— Outdoor thermometer ice alert
Maximum /minimum value record of
temperature and humidity
Wireless Outdoor Sensor:
— Wall Mount or Table Stand
— 433.92MHz RF transmitting frequency
— 60 meter transmission range in an open
area
Weather forecasting function
Power Supply:
Weather Station:
Battery: 2 x LR06 AA
Wireless Outdoor Sensor:
Battery: 2 x LR03 AAA
Wireless remote sensor (transmitter)
• Transmitter frequency: 433.92 MHz.
• Range of transmission is up to 60m
(200 feet).
• Insert the 2 batteries in to the transmitter. Pay
attention to observe the correct polarity.
INITIAL OPERATION:
•
•
•
•
•
MAIN UNIT APPEARANCE
•
Part A- LCD (Fig. A)
A1: Weather Forecasting
A2: Outdoor Temperature
A3: Outdoor Humidity
A4: Indoor Temperature
A5: Indoor Humidity
A6: Time
Open the Weather Station battery
compartment cover
Insert 2 x AA batteries observing polarity [ “+”
and “ –“ marks]
When you insert the batteries, all the icon
on the LCD will light up for 3 seconds, and
you will hear a beep tone, then detect indoor
temperature & humidity.
The Weather Station will now start to make
a connection to the outdoor remote sensor.
This operation takes about 3 minutes and is
displayed by a flashing reception RF antenna
symbol in the “OUTDOOR” display area on
the receiver.
This now, Open the remote Sensor battery
compartment cover, Insert 2 x AAA batteries
observing polarity [ “+” and “–“ marks]
After receiver has created a connection to the
outdoor remote sensor, After 3 minutes it will
Exit RF mode.
MANUAL TIME SETTING:
• Press and hold the “SET” button for 2
seconds, the temperature unit starts to
flash. Now use “+” and “-” buttons to set the
temperature unit in °C or °F you need.
• Press “SET” button to confirm your setting,
the 12/24HR start to flash. Now use“+” and “-”
buttons to set the 12/24 hour mode you need.
• Press “SET” to confirm your setting, the
Time zones start to flash, Now use“+” and “-”
buttons set a correct time zone (-12 to +12).
• Press “SET” to confirm your setting, the Hour
display starts to flash. Now use“+” and “-”
buttons to set the correct hour.
• Press “SET” to confirm your setting, the
Minute display starts to flash. Now use“+” and
“-” buttons to set the correct minute.
• Press “SET” button to confirm your setting,
the weather forecast pattern display starts to
flash. Now use“+” and “-” uttons to select the
current weather pattern.
• Press “SET” to confirm your setting and to
end the setting procedures, Then it will return
to the normal mode.
Part B – Back button and power (Fig. B):
B1:“SNOOZE/LIGHT” touch key
B2:“SET” button
B3:“MEM” button
B4:“+” button
B5: “-” button
B6: Battery compartment
WIRELESS OUTDOOR SENSOR
2
F.Y.I.:
• If there is no valid operation within 20
seconds, it will automatically return to normal
time mode from the set mode.
•
Setting the daily alarms:
• Press once “+” button, LCD display the “” ,
the alarm function is ON. Then press once “+”
button, the “” icon will disappears from the
display, the alarm function is OFF.
• Press once “SET” button, LCD display alarm
time, then Press and hold “SET” button for 2
seconds until hour of the Alarm time starts to
flash. Use the “+” and “-” buttons to set the
required hour.
• Press “SET” button to confirm your setting,
The Minute of the Alarm time starts to flash.
Use the “+” and “-” buttons to set the required
minute.
• Press “SET” button to confirm your setting,
the snooze time of the Alarm starts to flash.
Use the “+” and “-” buttons to set the minute
of snooze you need.
• Press “SET” button to confirm your setting
and to end the setting procedure.
If the Weather Station failed to receive
transmission from outdoor sensor (“- -.-”display
on the LCD), press and hold “-” button for 3
seconds to receive transmission manually. RF
icon “ ” flashes on the LCD.The Weather
Station to receive the remote sensor.
Query Maximum/minimum numerical value
• When the indoor / outdoor temperature /
humidity are shown in the LCD, The weather
station began to record temperature/humidity
maximum and minimum numerical value.
• Press once “MEM” button, the LCD will
display maximum value of temperature/
humidity, The LCD will display the minimum
value of temperature/humidity if press once
“MEM” button again when the maximum
value is displayed.
• at the same time, there are “MAX” or “MIN”
displayed on the LCD.
• The temperature/humidity maximum/minimum
value will RE records after press and hold
“MEM” button 3 seconds.
F.Y.I.:
• If the temperature reading is below ranges,
the LL.L will be displayed. If the temperature
reading is above ranges, the HH.H will be
displayed.
F.Y.I.:
• If there is no valid operation within 20
seconds, it will automatically return to normal
time mode from the alarm time set mode.
• The alarm will sound for 2 minutes if you
do not deactivate it by pressing any button.
In this case the alarm will be repeated
automatically after 24 hours.
• Rising alarm sound (crescendo, duration: 2
minutes) changes the volume 4 times whilst
the alarm signal is heard.
Ice alert
• The ice alert symbol appears and flashing
next to the outdoor temperature when the
outdoor temperature at –1°C to + 3°C or
+30°F to + 37°F.
Weather forecasting function
• Please take the weather forecast from your
local weather forecasting service into account
as well as the forecast from your weather
station. If there are discrepancies between
the information from your device and from the
local weather forecasting service, please take
the advice of the latter as authoritative.
• The weather forecast is calculated base on
the following humidity & temperature data
and may deviate from the actual weather
conditions if the station in central heating
room or the humidity & temperature record is
big different from the real natural state.
Switching off the alarm signal
• When the alarm is ringing, press any button
except the “SNOOZE/LIGHT” button to
stop the alarm signal. It is not necessary to
reactivate the alarm. It will ring again this time
next day.
Snooze function
• When the alarm is ringing, touch the
“SNOOZE/LIGHT” button the alarm mode will
to get to SNOOZE mode. The alarm signal
sounds again after already been set.
The weather station displays the following
weather symbols: sunny, light cloudy, cloudy and
rainy
The weather symbols indicate the weather
fluctuation over the next eight hours and not the
current weather.
3
ENGLISH
Please see table 1&2
RF Transmission Procedure:
• The weather station automatically starts
receiving transmission from outdoor thermo
sensor for outdoor temperature & humidity
after batteries inserted. transmission
from outdoor thermo sensor for outdoor
temperature after batteries inserted.
• The remote sensor will automatically transmit
temperature and humidity signal to the
Weather Station after batteries inserted.
">