Benning_2013
2013
World Class Test Equipment
IEC/EN 61243-3
DIN VDE 0682-401
Testing, Measuring and
Safety Instruments
BENNING World Class Test Equipment
2
The new generation of DUSPOL® voltage testers
safe voltage testing up to 1000 V
The international standard for voltage testers
IEC/EN 61243-3 (DIN VDE 0682-401):2011 increases
safety for work under voltage
The new generation of DUSPOL® voltage testers exceeds the
demands of the standards concerning both the protection category for housings (IP 65) and overvoltage protection (CAT IV
600 V). The nominal voltage range has been increased to a
minimum of 1000 V AC/DC in order to ensure safe testing of
increased system voltages of industrial applications, photovoltaic systems and wind power plants as well as of hybrid
automotive engineering.
Your work as an expert requires safe testing. Therefore, you
should not make any compromises concerning safety!
Voltage testers which are used on electrical systems of up to
1000 V have to comply with the standard IEC/EN 61243-3
(DIN VDE 0682-401):2011. The standard creates uniform
testing and safety criteria on an international level and remarkably which concentrates on user safety.
CAT IV 600 V
CAT IV 600 V
CAT IV 600 V
DUSPOL analog
DUSPOL expert
DUSPOL® digital
®
All DUSPOL® voltage testers are equipped with a direct display
system without loading the test point. In case of need, a load
circuit can be connected via a push-button which suppresses
inductive and capacitive reactive voltages. Thus, it is possible
to clearly distinguish between high-energy and low-energy
electric circuits.
Stand-by case
010911
(see page 18)
AC
1000 V D
C
V
1200
1000 VC
AC/D
1000 VC
AC/D
A vibrating motor can be activated additionally. The vibrating
power of this motor increases proportionally to the applied voltage. This is an additional indication of voltage being applied.
®
The DUSPOL voltage testers underlines once again the
BENNING expertise in the field of testing, measuring and
safety technology. With a DUSPOL® voltage tester you acquire an innovative product which has been tested and approved by the independent VDE Test and Certification
Institute.
®
DUSPOL® voltage testers
The original!
Product safety at the highest level:
• safe voltage testing up to 1000 V AC/DC
• direct display without actuating a push-button
(high-impedance testing)
• load connection via push-button
(low-impedance testing)
• battery-independent voltage indication
from 50 V AC/DC on
• vibration alert in the test handle
• robust round housing with rubberized gripping
surface for outdoor use (protection category IP 65)
• tested and approved in compliance with the current
DIN EN 61243-3 (VDE 0682-401):2011 standard
BENNING World Class Test Equipment
3
DUSPOL® voltage testers – the testers with the VDE mark of conformity
safe, reliable and powerful
The new generation of DUSPOL® voltage testers
• safe voltage testing up to 1000 V AC/DC
• load connection with vibration alert
• intentional tripping of a 30 mA RCD
• phase sequence test in a three-phase mains
• single-pole external conductor test (phase)
Additionally for DUSPOL® expert, DUSPOL® digital:
• acoustic continuity test with loud test buzzer and visual
indication by means of yellow LED
• measuring point illumination by means of white
high-power LED
• phase sequence test by means of green LED (left/right)
• detector for non-contact localization of cable breaks on
exposed and live lines
Additionally for DUSPOL® digital:
• voltage testing up to 1000 V AC TRUE RMS/1200 V DC
• TRUE RMS measuring method
• low-volt range: 1.0 V to 11.9 V
• frequency indication up to 1000 Hz
• resistance measurement up to 300 kΩ
• conducting-state voltage measurement of diodes
• automatic LC display illumination by means of a light sensor
phase-sequence test
(counter-clockwise/clockwise)
single-pole phase test:
“R” symbol for AC voltage
measuring point
illumination
acoustic and optical
continuity test
frequency indication
voltage indication
1 – 1000 V AC TRUE RMS
1 – 1200 V DC
resistance measurement and
diode test with conductingstate voltage indication
LC display with
background lighting
sensor of non-contact
cable break detector
CAT IV
600 V
load connection
via push buttons
vibrating alert
in the test handle
tested and
approved
housing with
protection against
dust and water jets
IEC/EN 61243-3
(DIN VDE 0682-401)
:2011 standard
Voltage and Continuity Tester
indication
indication steps
frequency range
acoustic and visual
continuity test
diode test
resistance measuring range
phase-sequence test
single-pole outer conductor test
polarity test
cable break detector
load connection
via push button
vibrating alarm
measuring point illumination
protection class
item no.
DUSPOL® analog
plunger system (illuminated)/LED
12 – 1000 V AC/DC
–
–
–
–
LCD (“R” symbol)
LCD (“R” symbol)
LED (+/-)
–
IS = 600 mA (1000 V)
30 mA RCD trip
yes
–
IP 65
050261
DUSPOL® expert
DUSPOL® digital
LED
LED/LCD (illuminated)
12 – 1000 V AC/DC
1.0 – 1000 V AC/1200 V DC
–
1 – 1000 Hz
buzzer + yellow LED
buzzer + yellow LED
0 – 100 kΩ
0 – 100 kΩ
conducting-state/
0.3 – 2.0 V
non-conducting direction
–
0.1 kΩ – 300 kΩ
green LEDs (right/left)
green LEDs (right/left)
red “lightning” LED
red “lightning” LED
LED (+/-)
LCD (+/-)
yellow LED (flashing)
yellow LED (flashing)
IS = 550 mA (1000 V)
IS = 550 mA (1000 V)
30 mA RCD trip
30 mA RCD trip
yes
yes
white LED
white LED
IP 65
IP 65
050262
050263
PROFIPOL®
LED
6 – 400 V AC/DC
–
–
–
–
–
–
LED (+/-)
–
–
–
–
IP 65
020022
PROFIPOL®
BENNING World Class Test Equipment
4
Digital Multimeter BENNING MM P3, MM 1-1 – MM 1-3, MM 1 – MM 4
reliable and precise in each and every situation
BENNING MM P3
Pocket-Size Digital Multimeter
BENNING MM 1-1, MM 1-2 and MM 1-3
Digital Multimeters with Volt Sensor Function
• top-class functionality and design
• even smaller and narrower with lower weight (only 130 g)
• minimum dimensions: 132 x 86 x 19 mm
• for all-purpose use with leather case and measuring leads
• the integrated Volt sensor signalises phase voltages by
means of an acoustic signal and a red LED signal
• it localizes cable breaks and defective lamps in exposed
cables (cable reel, light chains) via the feeding side of the
phase
volt sensor
volt sensor
volt sensor
MM 1-1
MM 1-2
MM P3
MM 1-3
BENNING MM 1, MM 2, MM 3 and MM 4
Digital Multimeter
Technology that inspires, Quality that convinces
tested and
approved
MM 1
MM 3
MM 2
Million fold proven as well as tested and approved by the
independent VDE Test and Certification Institute according to
current international standards.
• basic measuring for current, voltage, resistance, continuity,
diode, capacity and frequency
• automatic and/or manual measuring range selection
• safe current measuring up to 300 A AC via attachable current clamp adapter (MM 4)
IEC/EN 61010-1
(DIN VDE 0411-1)
Digital Multimeter
MM 4
indicating range
basic accuracy
AC voltage
DC voltage
AC current
DC current
resistance
continuity/diode
frequency
capacity
temperature
volt sensor
interface
software
memory
Data Log function
measuring method
measuring category
item no.
BENNING
BENNING
MM P3
MM 1-1
5000
2000
0.6 %
0.5 %
0.1 mV – 600 V 0.1 mV – 750 V
0.1 mV – 600 V 0.1 mV – 1000 V
–
–
–
–
0.1 Ω – 40 MΩ 0.1 Ω – 20 MΩ
yes/yes
yes/yes
1 mHz – 5 MHz
–
10 pF – 100 µF
–
–
–
–
yes
–
–
–
–
HOLD
HOLD
–
–
RMS
RMS
CAT III 300 V
CAT III 600 V
044084
044081
BENNING
MM 1-2
2000
0.5 %
0.1 mV – 750 V
0.1 mV – 1000 V
1 mA – 10 A
1 mA – 10 A
0.1 Ω – 20 MΩ
yes/yes
1 Hz – 20 MHz
1 pF – 2 mF
–
yes
–
–
HOLD, MAX/MIN
–
RMS
CAT III 600 V
044082
BENNING
MM 1-3
2000
0.5 %
0.1 mV – 750 V
0.1 mV – 1000 V
1 mA – 10 A
1 mA – 10 A
0.1 Ω – 20 MΩ
yes/yes
1 Hz – 20 MHz
1 pF – 2 mF
-20 °C up to +800 °C
yes
–
–
HOLD, MAX/MIN
–
RMS
CAT III 600 V
044083
BENNING
BENNING
MM 1
MM 2
3200
2000
0.5 %
0.5 %
1 mV – 600 V 0.1 mV – 750 V
0.1 mV – 600 V 0.1 mV – 1000 V
–
0.1 µA – 20 A
0.1 µA – 3.2 mA 0.1 µA – 20 A
0.1 Ω – 32 MΩ 0.1 Ω – 20 MΩ
yes/yes
yes/yes
–
–
–
–
–
–
–
–
–
–
–
–
HOLD
–
–
–
RMS
RMS
CAT III 600 V
CAT III 600 V
044027
044028
BENNING
MM 3
2000
0.5 %
0.1 mV – 600 V
0.1 mV – 600 V
0.1 µA – 20 A
0.1 µA – 20 A
0.1 Ω – 20 MΩ
yes/yes
1 Hz – 200 kHz
1 pF – 200 µF
–
–
–
–
–
–
RMS
CAT III 300 V
044029
BENNING World Class Test Equipment
5
Digital Multimeter BENNING 7-1 – MM 11
safety and functional diversity without any compromises
BENNING MM 7-1
Digital Multimeter offering highest safety
for industrial applications
BENNING MM 9, MM 10
Digital Multimeter of the highest measuring
category CAT IV
• TRUE RMS measuring method for precise measuring
results even for non-sinusoidal signal characteristics
• highest measuring category CAT IV 600 V for highest safety
• AutoV function for automatic AC/DC voltage detection and
low input impedance (LoZ) to suppress capacitively/inductively induced voltages
• integrated Volt sensor for non-contact signalling of phase
voltages and cable breaks in lines
• LC display with bargraph indication and background lighting
• highest measuring category CAT IV 600 V allows measurements direct at the source of the low-voltage installation
• precise due to TRUE RMS measuring method
• transmitting measuring results via optical USB interface
• delivery including software BENNING PC-Win MM 10
tested and
approved
IEC/EN 61010-1
(DIN VDE 0411-1)
USB
volt sensor
USB
CAT IV 600 V
TRUE RMS
CAT IV 600 V
TRUE RMS
MM 9
MM 10
BENNING MM 11
Precision Digital Multimeter
with extraordinary features of performance
CAT IV 600 V
TRUE RMS
• highest measuring accuracy of 0.06 % due to TRUE RMS
measuring method and 20000 digit resolution
• an ideal measuring device for recording of measuring processes
• large memory capacity of 1000 storage locations and
40000 storage locations for Data Log functions
• transmitting measuring results via optical USB interface
• delivery including software BENNING PC-Win MM 11
TRUE RMS
MM 11
MM 7-1
Digital Multimeter
indicating range
basic accuracy
AC voltage
DC voltage
AC current
DC current
resistance
continuity/diode
frequency
capacity
temperature
volt sensor
interface
software
memory
Data Log function
measuring method
measuring category
item no.
BENNING
MM 4
4200
0.5 %
1 mV – 600 V
1 mV – 600 V
0.1 A – 300 A
–
0.1 Ω – 42 MΩ
yes/yes
–
–
–
–
–
–
HOLD
–
RMS
CAT III 300 V
044073
BENNING
BENNING
MM 7-1
MM 9
6000
6000
0.08 %
0.5 %
10 µV – 1000 V 0.1 mV – 750 V
10 µV – 1000 V 0.1 mV – 1000 V
10 µA – 10 A
1 mA – 10 A
10 µA – 10 A
0.1 µA – 10 A
0.1 Ω – 40 MΩ 0.1 Ω – 60 MΩ
yes/yes
yes/yes
0.01 Hz – 100 kHz 1 Hz – 60 MHz
1 nF – 10 mF
1 pF – 6 mF
-40 °C up to +400 °C
–
yes
–
–
–
–
–
HOLD, MAX/MIN HOLD, MAX/MIN
–
–
TRUE RMS
TRUE RMS
CAT IV 600 V
CAT IV 600 V
044085
044078
BENNING
MM 10
6000
0.5 %
0.1 mV – 750 V
0.1 mV – 1000 V
1 mA – 10 A
0.1 µA – 10 A
0.1 Ω – 60 MΩ
yes/yes
1 Hz – 60 MHz
1 pF – 6 mF
–
–
USB
PC–Win MM 10
HOLD, MAX/MIN
–
TRUE RMS
CAT IV 600 V
044079
BENNING
MM 11
20000
0.06 %
1 µV – 750 V
1 µV – 1000 V
1 µA – 10 A
1 µA – 10 A
10 mΩ – 2 GΩ
yes/yes
0.01 Hz – 1 MHz
1 pF – 40 mF
-200 °C up to +1200 °C
–
USB
PC–Win MM 11
1000 memory locations
40000 memory locations
TRUE RMS
CAT III 600 V
044080
BENNING PC-Win MM 10/MM 11
Software for logging and analysis
• software for reading and logging of measurement series
• visualisation of measurement series via line diagram and table
• scanning rate variable from 0.5 sec. up to 10 min.
• storage of measurement series as text file
Software PC-Win MM 10/MM 11
All Digital Multimeters
including protective case,
safety leads and battery set.
BENNING World Class Test Equipment
6
Digital Current Clamp Multimeter
BENNING CM 1-1 – CM 1-3, CM 2, CM 3, CC 1 – CC 3
BENNING CM 1-1, CM 1-2 and CM 1-3
Digital Current Clamp Multimeter for AC current
Innovative technology, practical design
BENNING CM 2 and CM 3
Digital Current Clamp Multimeter for
AC/DC current
• safe current measuring up to 400 A AC
• measuring inputs for voltage, resistance, continuity and
diode test
• integrated volt sensor signalises phase voltages by means
of an acoustic signal and a red LED signal (CM 1-3)
• it localizes cable breaks and defective lamps in exposed
cables (cable reel, light chains) via the feeding side of the
phase (CM 1-3)
• safe and non-contact measuring of high currents
• DC and AC current measuring up to 600 A AC/DC
• measurement of low currents (automotive, photovoltaics,
industry) (CM 2)
• measuring inputs for voltage, resistance and continuity
test (CM 2)
volt sensor
Our !
er
best sell
CM 2
CM 1-2
CM 3
CAT IV 600 V
CM 1-1
CM 1-3
BENNING CC 1, CC 2 and CC 3
AC and AC/DC current clamp adapters
• safe AC current measuring up to 200 A/400 A
• connection via 4 mm safety measuring leads
output: 1 mV AC per
1 A AC
output: 1 mA AC per
1 A AC
output: 1 mV/10 mV AC/DC
per 1 A AC/DC
suitable for BENNING ...
MM 1-1/1-2/1-3,
MM 2/3/7-1/9/10/11
suitable for BENNING ...
IT 120 B, MM 1-2/1-3,
MM 2/3/7-1/9/10/11
suitable for BENNING ...
PV 1-1, MM 1-1/1-2/1-3,
MM 2/3/7-1/9/10/11
CC 1
CC 2
CC 3
Digital Current Clamp Multimeter/Current Clamp Adapter
indicating range
basic accuracy
AC voltage
DC voltage
AC current
DC current
resistance
continuity/diode
frequency
effective power
power factor (cos φ)
temperature
volt sensor
memory
measuring method
max. clamp opening
measuring category
item no.
BENNING
CC 1
–
1.9 %
–
–
1 A – 400 A
–
–
–/–
–
–
–
–
–
–
–
30 mm
CAT III 300 V
044037
BENNING
CC 2
–
1%–3%
–
–
0.5 A – 200 A
–
–
–/–
–
–
–
–
–
–
–
21 mm
CAT III 600 V
044110
BENNING
CC 3
–
1%–2%
–
–
0.2 A – 300 A
0.2 A – 300 A
–
–/–
–
–
–
–
–
–
–
25 mm
CAT III 600 V
044038
BENNING
BENNING
BENNING
CM 1-1
CM 1-2
CM 1-3
2000
2000
2000
2%
1%
1%
–
0.1 V – 600 V
0.1 V – 750 V
–
0.1 V – 600 V 0.1 V – 1000 V
10 mA – 400 A 0.1 A – 400 A
0.1 A – 200 A
–
–
–
–
0.1 Ω – 20 MΩ 0.1 Ω – 20 MΩ
–/–
yes/–
yes/yes
–
–
–
–
–
–
–
–
–
–
–
–
–
–
yes
HOLD, MAX
HOLD
HOLD
RMS
RMS
RMS
30 mm
30 mm
16 mm
CAT III 600 V
CAT III 600 V
CAT IV 600 V
044061
044062
044063
BENNING
CM 2
4000
0.5 %
0.1 mV – 600 V
0.1 mV – 600 V
10 mA – 300 A
10 mA – 300 A
0.1 Ω – 40 MΩ
yes/–
–
–
–
–
–
HOLD, MAX
RMS
25 mm
CAT III 300 V
044035
BENNING
CM 3
2000
1.9 %
–
–
0.1 A – 600 A
0.1 A – 600 A
–
–/–
–
–
–
–
HOLD
RMS
38 mm
CAT III 300 V
044031
BENNING World Class Test Equipment
Digital Current Clamp Multimeter
BENNING CM 4, CM 6, CM 7
Digital Current Clamp Multimeter of the highest
measuring category
• precise due to TRUE RMS measuring method
• safe current measuring up to 1000 A AC/DC
• highest measuring category CAT IV 600 V offering optimum
safety
ESTAUTOTtion
func
7
BENNING CM 4 – CM 9
BENNING CM 8
Power Current-Clamp Multimeter
Power analysis for single-phase and
three-phase mains
• TRUE-RMS measurements up to 1000 V, 600 A AC/DC
• effective power measurements up to 600 kW
• calculation of the power factor cos φ
• indication of the load type (inductive, capacitive)
• bipolar phase sequence test in three-phase mains
• measuring inputs for voltage, resistance, continuity, diode,
frequency and temperature
• measurement of inrush currents (motors etc.)
BENNING CM 9
Leakage Current Clamp with a Resolution of 1 µA
The alternative solution for insulation measurements
tested and
approved
IEC/EN 61010-1
(DIN VDE 0411-1)
CAT IV 600 V
TRUE RMS
CAT IV 600 V
TRUE RMS
CM 5-1
CM 7
(CM 6 fig. similar)
BENNING CM 5-1
Digital Current-Clamp Multimeter
• automatic selection of the correct measuring function for TRUE
RMS voltage/current (AC/DC), resistance, continuity and diode test
• safe and easy operation – measuring errors due to incorrect
measuring range selection are excluded
• short response time due to 5 scanning values per second
• voltage measurement with low input impedance (LoZ) to
suppress capacitively/inductively induced voltages
• measurement of leakage currents and differential currents
in electrical systems (VDE 0100) and devices (VDE 07010702, BGV A3, BetrSichV ( = German Health and Safety at
Work Regulations))
• highest resolution of 1 µA in the 6 mA measuring range
• measurement without switch-off during normal operation
of the system/device, the perfect solution for preventive
maintenance
• precise and reproducible measuring results up to 100 A
• optimum screening against external magnetic fields
TRUE RMS
CM 8
(CM 4 fig. similar)
Differential current measurement method with BENNING CM 9
✔
✔
0 mA
FI/RCD
L
N
PE
✘
25 mA
0 mA
✔
0 mA
✔
0 mA
✘
25 mA
✘
25 mA
Digital Current Clamp Multimeter
indicating range
basic accuracy
AC voltage
DC voltage
AC current
DC current
resistance
continuity/diode
frequency
effective power
power factor (cos φ)
temperature
volt sensor
memory
measuring method
max. clamp opening
measuring category
item no.
BENNING
BENNING
BENNING
CM 4
CM 5-1
CM 6
4000
9999
4000
0.7 %
0.9 %
0.7 %
0.1 V – 600 V
1.3 V – 750 V
0.1 V – 750 V
0.1 V – 600 V 0.7 V – 1000 V 0.1 V – 1000 V
0.1 A – 600 A
0.9 A – 600 A 0.1 A – 1000 A
–
0.9 A – 600 A
–
0.1 Ω – 400 Ω 1 Ω – 10 kΩ 0.1 Ω – 400 Ω
yes/–
yes/yes
yes/–
1 Hz – 400 Hz
–
1 Hz – 400 Hz
–
–
–
–
–
–
–
–
–
–
–
–
HOLD, MAX/MIN
HOLD, MAX/MIN
HOLD
PEAK
PEAK
RMS
TRUE RMS
RMS
37 mm
35 mm
53 mm
CAT III 600 V
CAT IV 600 V
CAT IV 600 V
044056
044066
044058
BENNING
CM 7
4000
0.7 %
0.1 V – 750 V
0.1 V – 1000 V
0.1 A – 1000 A
0.1 A – 1000 A
0.1 Ω – 400 Ω
yes/–
1 Hz – 400 Hz
–
–
–
–
HOLD, MAX/MIN
PEAK, ZERO
TRUE RMS
53 mm
CAT IV 600 V
044059
BENNING
CM 8
6000
0.7 %
10 mV – 1000 V
10 mV – 1000 V
0.1 A – 600 A
0.1 A – 600 A
0.1 Ω – 20 kΩ
yes/yes
0.1 Hz – 4 kHz
1 W – 600 kW
± 0.00 – 1.00
-50 °C up to +1000 °C
–
HOLD, MAX/MIN
PEAK, INRUSH
TRUE RMS
40 mm
CAT III 600 V
044064
BENNING
CM 9
6000
1%
–
–
1 µA – 100 A
–
–
–/–
–
–
–
–
–
Leakage
CM 9
HOLD, PEAK
RMS
40 mm
CAT III 300 V
044065
differential current measurement method
BENNING World Class Test Equipment
8
BENNING ST 710 Appliance Tester (VDE 0701-0702)
mobile and network-independent testing of electrical appliances
BENNING ST 710
Battery-operated Appliance Tester for
mobile testing of electrical devices
Features BENNING ST 710
• testing in compliance with DIN VDE 0701-0702 (EN 62638),
BGV A3, BetrSichV (German Health and Safety at Work
Regulations), ÖVE/ÖNORM E 8701, NEN 3140
• easy - operation by means of three keys
• quick - complete testing within 10 seconds
• mobile - testing can be made network-independently
Application
Safety-related testing of electrical devices/work equipment
such as e.g. electrical devices/tools with ON/OFF switch,
motorized equipment, lamps, cable reels, multiple distributors
and household appliances. The protective conductor current/
contact current is measured by means of the alternative
leakage current measurement method.
• automatic testing procedure for devices of class I (key 1),
class II/III (key 2) and line test (key 3)
• testing of cable reels, multiple distributors and device
connecting cables with rubber connector
• measuring result with “pass/fail” information
• limiting values preset in compliance with DIN VDE standard
• indication of correct function key in case of incorrect operation and if the test sample is not switched on
• sufficient battery capacity (6 x 1.5 V, mignon, AA, IEC LR6)
for > 2500 test samples
• three-phase test objects can be tested by means of
optional measuring adapter
Measuring functions
• protective conductor resistance with a testing current of
200 mA DC and automatic polarity reversal
• insulating resistance with a testing voltage of 500 V DC
• protective conductor current and contact current by means
of alternative leakage current measurement method
• voltage measurement on external shock-proof socket (L-N,
L-PE, N-PE)
cates for are
test certifi
Forms for f electrical devices”
“Testing o r download free of
available fowww.benning.de!
charge at
Shock-proof socket onto
shock-proof plug for CM 9
16 A/32 A CEE coupling onto
CEE plug, 5-pin, for CM 9
Leakage
CM 9
Test badges
BENNING ST 710
Battery-operated Appliance Tester
BENNING
ST 710
graphic display
0.05 Ω – 20 Ω
Scope of delivery BENNING ST 710
indication= ID
IPE
ID = IPE + IL
IL Leakage current e.g. via
the water conduits and
capacity of the washing
machine to earth
©
ST 710
050309: with socket of type E (B/F/CZ/SK/PL)
050315: with socket of type CH (CH)
(test sample under
operating conditions)
Differential current measurement method with BENNING CM 9
indication
protective conductor resistance
insulation resistance
0.1 MΩ – 20 MΩ
(500 V DC)
protective conductor current/
contact current by means of
0.1 mA – 20 mA
alternative leakage current
measurement method
line test
RPE, RISO, short–circuit test and continuity test of
phase conductor (L) and neutral conductor (N)
voltage
50 V – 270 V
scope of delivery
carrying case, test cable with alligator
clip, appliance cable, battery set
item no.
050308
Optional accessories for
BENNING ST 710/ST 720/ST 750 A
test badges “next test” (300 pieces)
item no. 756212
measuring adapters for three-phase loads (passive)
(see page 9)
item no. 044122/044123
leakage Current Clamp BENNING CM 9 for the measurement of
differential current, protective conductor current and load current of
single-phase and three-phase loads
(see page 7)
item no. 044065
measuring adapters for leakage current clamp BENNING CM 9
single-phase, conductors led through individually and with double insulation
shock-proof socket/shock-proof plug
item no. 044131
three-phase, conductors led through individually and with double insulation
16 A CEE coupling-CEE plug, 5–pin
item no. 044127
32 A CEE coupling-CEE plug, 5–pin
item no. 044128
See page 18 + 19 for further accessories
BENNING World Class Test Equipment
9
BENNING ST 720 Appliance Tester (VDE 0701-0702)
testing of electrical appliances under operating conditions
BENNING ST 720
Mains-operated and battery-operated Appliance
Tester for mobile testing of electrical devices
• testing in compliance with DIN VDE 0701-0702 (EN 62638),
BGV A3, BetrSichV (German Health and Safety at Work Regulations), ÖVE/ÖNORM E 8701, NEN 3140
• quick – testing within a few seconds
• all-in-one – appliance tester and RCD tester in one single device
• unique – testing of single-phase and three-phase devices
under operating conditions
Application
Testing of devices with mains voltage-dependent switching elements/mains-supply units/relays such as controlled devices/tools, devices of information and communication technology as well as of devices which can be tested
completely with mains voltage only.
In mains operating mode, the protective conductor
current/contact current is measured by means of the required
differential current/direct measurement method.
Features BENNING ST 720
• mains operating mode for tests under operating conditions
• battery operating mode for mobile testing
• automatic testing procedure for devices of class I (key 1),
class II/III (key 2) and line test (key 1)
• reduction of the ISO testing voltage to 250 V/ 500 V for
devices with overvoltage arresters/electronic devices
• testing of RCDs with 30 mA
• measuring result with “pass/fail” information
• limiting values preset in compliance with DIN VDE standard
• indication of correct function key in case of incorrect operation, overload and if the test sample is not switched on
• sufficient battery capacity (6 x 1.5 V, mignon, AA, IEC LR6)
for > 2500 test samples
BENNING ST 720
Mains-operated and battery-operated Appliance Tester
BENNING
ST 720
graphic display
0.05 Ω – 20 Ω
indication
protective conductor resistance
insulation resistance
0.1 MΩ – 20 MΩ
(250 V/500 V DC)
protective conductor current/
contact current by means of
- differential current
0.25 mA – 20 mA
measurement method
- alternative leakage current
0.25 mA – 20 mA
measurement method
- direct measurement method
0.1 mA – 2 mA
line test
RPE, RISO, short-circuit test and continuity test of
phase conductor (L) and neutral conductor (N)
testing current of RCD
30 mA
tripping time
10 ms – 500 ms
protective conductor current of
three-phase test objects under
0.25 mA – 10 mA
operating conditions (optional)
voltage
50 V – 270 V
scope of delivery
carrying case, test cable with
alligator clip, mains connection cable,
appliance cable, battery set
item no.
050312
Measuring functions
• protective conductor resistance with a testing current of
200 mA DC and automatic polarity reversal
• insulating resistance with a testing voltage of 250 V/500 V DC
• mains operating mode: protective conductor current/contact
current by means of differential current/direct measurement
method with automatic mains pole reversal
• battery operating mode: protective conductor current/contact current by means of alternative leakage current measurement method
• tripping time measurement of RCDs with 30 mA
• voltage measurement on external shock-proof socket
(L-N, L-PE, N-PE)
• active testing of three-phase devices under operating conditions by means of optional measuring adapters (item no.
044140/044141)
nt
ntial curreethod
en t m
measurem CDs with 30 mA
R
of
se loads
• testing
f three-pha 50 V
o
g
n
ti
s
te
e
2
• activ
ge of
sting volta
• ISO te
• differe
16 A/32 A CEE 5-pin, active,
for ST 720
16 A/32 A CEE coupling, 5-pin onto shock-proof
plug (passive) for ST 710/ST 720/ST 750 A
16 A/32 A CEE coupling, 3-pin onto shock-proof
plug for ST 710/ST 720/ST 750 A
Shock-proof 4 mm plug for
devices without shock-proof
plug for ST 710/ST 720
ST 720
050313: with socket of type E (B/F/CZ/SK/PL)
Optional accessories for
BENNING ST 720
measuring adapters for three-phase loads (active)
for measuring RPE, and IPE under operating conditions
16 A CEE 5-pin active
item no. 044140
32 A CEE 5-pin active
item no. 044141
BENNING ST 710/ST 720/ST 750 A
measuring adapters for three-phase loads (passive)
for measurement of RPE, RISO and IEA
16 A CEE coupling, 5-pin - shock-proof plug
item no. 044122
32 A CEE coupling, 5-pin - shock-proof plug
item no. 044123
measuring adapters for single-phase loads
for measurement of RPE, RISO and IEA
16 A CEE coupling, 3-pin - shock-proof plug
item no. 044143
32 A CEE coupling, 3-pin - shock-proof plug
item no. 044144
shock-proof 4 mm plug for devices without
shock-proof plug
item no. 044142
See page 18 + 19 for further accessories
Scope of delivery BENNING ST 720
BENNING World Class Test Equipment
10
BENNING ST 750 A Appliance Tester (VDE 0701-0702, VDE 0751)
testing of electrical appliances and medical electrical devices
AddIn for Mebedo
test software
ELEKTROmanager
and fundamed
BENNING ST 750 A
Appliance Tester for testing electrical appliances
and medical electrical devices
• testing according to
- DIN VDE 0701-0702 (EN 62638): testing of electrical appliances/equipment
- DIN VDE 0751-1 (EN 62353): testing of medical electrical
devices, such as hospital bed
- German Health and Safety at Work Regulation
• innovative - indication and operation via colour LCD touchscreen
• powerful - 2 GB memory card for more than 100000 tests
• all in one - one appliance tester for all VDE tests
ted
-operain case
y
r
e
t
t
Ba terface
ge
user in tation chan
s
e
r
of test power failu
and
Features
• automatic and auto-configurable testing procedures
• complete test sample/customer database can be stored on SD
card and thus is directly available at the place of inspection
• management of large test sample inventories with more
than 100000 storable device tests per 2 GB SD card
• direct entry via touchscreen and external keyboard/mouse
• measuring result with “pass/fail” indication and acoustic
warning signal, if the test has been failed
• help function and schematic connecting diagrams
• separate 4 mm test sockets and IEC connector
• 3 x USB interface for PC, external keyboard and RFID reader/writer
• 1 x RS 232 interface for barcode scanner, printer and SD card slot
• free firmware update possible via SD card/USB stick
ST 750 A
Measuring functions
• protective conductor resistance with 200 mA DC and a testing
current of 10 A AC
• insulating resistance with a testing voltage of 50 V to 500 V (adjustable)
• protective conductor current/contact current via differential
current measurement method, alternative leakage current
measurement method or direct measurement
• functional test with indication of leakage current, mains voltage,
load current, effective power, apparent power and measuring time
• testing of device connecting cables and extension cables
• testing of three-phase loads by means of optional measuring adapters
• additionally for VDE 0751-1: device leakage current, leakage
current of application part type B, type BF and type CF
BENNING ST 750 A
Appliance Tester (VDE 0701-0702, VDE 0751)
BENNING
ST 750 A
5.7“ colour LCD touchscreen, ¼ VGA
1 mΩ – 20 Ω
0.1 MΩ – 100 MΩ
Leakage
CM 9
Active testing of
three-phase loads by
means of test procedures
with BENNING CM 9
differential current clamp
and measuring adapter
044127/044128
display
protective conductor resistance
insulation resistance
protective conductor current/
contact current via differential
current measurement method,
0.05 mA – 25 mA
alternative leakage current
measurement method or
direct measurement
device leakage current and
leakage current of the applied part
0.05 mA – 25 mA
for medical electrical devices
line test
RPE, RISO, IPE, short-circuit test and continuity test
of phase conductor (L) and neutral conductor (N)
voltage/current
1 V - 360 V/0.1 A - 16 A
effective power/apparent power
20 W - 4000 W
interface
3 x USB, 1 x RS 232
dimensions/weight
405 x 330 x 165 mm/approx. 6 kg
scope of delivery
tester in waterproof (IP 67), break-proof case,
test cable with alligator clip, appliance
cable, input stylus, 2 GB SD card
item no.
050310
by
a t ion
A p plic s cr e e n!
touch
Touchscreen
Order recommendation
• appliance tester BENNING ST 750 A
• software BENNING PC-Win ST 750
• barcode scanner
• barcode labels (1000 pieces)
• test badges “next test”
(300 pieces) (see page 8)
item no. 050320
item no. 047001
item no. 009369
item no. 756301
item no. 756212
Optional accessories for BENNING ST 750 A
measuring adapters for three-phase loads (passive)
for measurement of RPE, RISO and IEA
16 A CEE coupling, 5-pin - shock-proof plug
item no. 044122
32 A CEE coupling, 5-pin - shock-proof plug
item no. 044123
Leakage Current Clamp BENNING CM 9 for measurement of differential current, protective conductor current, load current of loads
(see pages 7/8)
item no. 044065
measuring adapters for leakage current clamp BENNING CM 9
single-phase, conductors led through individually and with double insulation
shock-proof socket/shock-proof plug
item no. 044131
three-phase, conductors led through individually and with double insulation
16 A CEE-CEE, 5-pin
item no. 044127
32 A CEE-CEE, 5-pin
item no. 044128
See pages 18 and 19 for further accessories
BENNING World Class Test Equipment
11
BENNING PC-Win ST 750 documentation software
helpful accessories for efficient testing
Software PC-Win ST 750
Software
BENNING PC-Win ST 750
Portable log printer BENNING PT 1
with Bluetooth®
• professional PC software for the management and documentation of recorded measuring values
• explicit database structure with customer, department, test
sample and test result including the test date
• easily creating and copying customers and test samples
• printing of the test results as single log and serial log
• bidirectional data transmission PC BENNING ST 750 A
• import and export function of existing test sample and customer databases via MS Excel®
• free software update to the latest version available per
download
• the perfect solution for printing test records rapidly on site
• high printing speed due to direct thermal printing process
• data transmission via Bluetooth® or RS232 interface
• power supply by means of rechargeable NiMH battery pack
• width/length of thermographic paper rolls: 58 mm/13 m
• included in delivery: 6 V battery pack, mains supply BENNING PT 1 printer
unit, belt clip, wall fastening, Bluetooth® dongle for
BENNING ST 750, 2 rolls of thermographic paper and
RS232 cable
Roll of thermographic
paper
Barcode label
Test sample identification via
barcode scanner/labels
Compact
industrial keyboard
• particularly suited for repetitive testing and identification of
large test sample inventories in offices, administrations etc.
• highly adhesive PVC barcode labels with barcode and consecutive numbering (reels of 1000 pieces)
• barcode scanner with RS 232 interface supports all
conventional barcodes such as UPC/EAN/JAN, Code 39,
Code 128 etc.
• high-quality functional keyboard with integrated trackball
for comfortable input of test sample/customer data on site
• compact keyboard dimensions for
safe transport in the BENNING
ST 750 A appliance tester
• data transmission via Bluetooth® or
USB interface
• increased protection against dust
and splash water
industrial keyboard
Barcode scanner
Test sample identification via
RFID reader/writer or transponder
• test sample identification via radio frequency (“Radio Frequency
Identification”) without visual contact or direct contact of the
transponder
• RFID technology stores the test sample data/measuring values
directly onto a memory chip (transponder) on the test sample
• particularly suited for rough industrial environments
• tag-type transponder for attachment by means of cable ties
• ring clip transponder for attachment to the mains supply line
• epoxy resin transponder (self-adhesive) for attachment into
the housing or onto the surface of the housing
• transponder frequency: HF 13.56 MHz; memory depth:10 kbit
Tag-type
transponder
Ring clip
transponder
Self-adhesive epoxy
resin transponder
RFID reader/writer
Optional accessories for BENNING ST 750 A
software BENNING PC-Win ST 750
on CD-ROM incl. USB cable
item no. 047001
barcode scanner
with RS 232 interface
item no. 009369
barcode labels with consecutive numeric representation
(1000 pieces)
item no. 756301
printer BENNING PT 1
with Bluetooth® and RS 232 interface
item no. 044150
roll of thermographic paper
(20 pieces)
item no. 044151
See pages 18 and 19 for further accessories
industrial keyboard
with USB interface
item no. 044154
RFID reader/writer
with USB interface
item no. 009370
RFID transponder, tag-type, height/width: 43 x 34 mm
(100 pieces)
item no. 044139
RFID transponder, ring clip, inside diameter: 7.5 mm
(100 pieces)
item no. 044138
RFID transponder, self-adhesive, diameter/height: 17 mm/2.5 mm
(100 pieces)
item no. 044137
BENNING World Class Test Equipment
12
Safety Instruments BENNING IT 101, IT 110 and IT 120 B
testing of electrical systems in compliance with the standards
BENNING IT 101
Insulation and Resistance Measuring Device
• measurement of insulating resistance and calculation of
the resulting leakage current
• testing voltages of 50 V, 100 V, 250 V, 500 V and 1000 V
• selectable limiting values for ISO measurement, green LED
for “PASS”, red LED for testing voltage/external voltage
• resistance measurement with a testing current of 200 mA
for testing protective conductor connections
• measurement of polarization index (PI) and dielectric
absorption rate (DAR)
• switchable probe tip for triggering the measuring process
• internal memory for 100 measuring values per measuring function
• TRUE RMS voltage measurement with low-pass filter
• including case, switchable probe tip, silicone measuring
leads, magnetic hook, alligator clips, rubber protective
frame and batteries
BENNING IT 110, BENNING IT 120 B
Installation Testers
For safety tests on electrical systems
according to DIN VDE 0100 and IEC 60364
Multifunctional installation testers for complete testing and
efficient troubleshooting of electrical systems
• measurement of the protective conductor line and of the
equipotential bonding line with a testing current of 200 mA
• measurement of the insulation resistance with testing voltages of 100 V, 250 V, 500 V and 1000 V
• line impedance and loop impedance measurement (optional
without tripping of the RCD) with calculation of the shortcircuit current (PFC/PSC)
• complete testing of RCDs with nominal fault currents of
10/30/100/300/500/1000 mA
• measurement of contact voltage (without tripping), tripping
time and tripping current (ramp test) of residual current
operated device (RCD)
• phase-sequence testing in three-phase mains
• voltage measurement up to 500 V and online voltage monitoring
IT 110
BENNING IT 110
Installation Tester
CAT IV 600 V
TRUE RMS
IT 101
BENNING TA 5
BENNING IT 101
Insulation and Resistance Measuring Device
Scope of delivery BENNING IT 101
BENNING
IT 101
indicating range
4000 digits (illumination)
low-impedance resistance
0.01 Ω – 40 Ω
insulation resistance
1 kΩ – 20 GΩ
resistance
0.01 Ω – 40 kΩ
voltage
0.1 V – 600 V AC/DC TRUE RMS
supplementary function
leakage current, polarization index (PI),
dielectric absorption rate (DAR), automatic
discharge function, null balance of the
measuring leads
measured value memory
500 measuring results
measuring category
CAT IV 600 V
item no.
044033
display
low-impedance resistance
insulation resistance
line impedance (L-N/L)
loop impedance (L-PE)
short-circuit current
RCD testing
type AC, A
phase sequence
voltage, frequency
item no.
BENNING
IT 110
graphic display (illuminated)
0.01 Ω – 2000 Ω
1 kΩ – 1000 MΩ
0.01 Ω – 2000 Ω
0.01 Ω – 2000 Ω
0.01 A – 24.4 kA
tripping time, tripping current,
contact voltage
yes
1 V – 500 V, 45 Hz – 65 Hz
044100
Optional accessories for
BENNING IT 101/IT 110/IT 120 B
40 m measurement cable BENNING TA 5 with practical winder, strap,
for the measurement of protective and bonding conductors,
connection: Ø 4 mm safety test
item no. 044039
BENNING World Class Test Equipment
13
BENNING IT 110, IT 120 B Installation Testers
the perfect solution for efficient testing
Features
BENNING IT 110, BENNING IT 120 B
Logging software with Test Log according to ZVEH
BENNING PC-Win IT 120 B
• all measuring functions can be selected directly by means
of a rotary switch
• switchable probe tip for releasing the measuring process
• graphic display and help function with connecting diagram
• complete measuring result with measuring parameters,
limiting value and symbols for PASS/FAIL
• current supply by means of 6 NiMH storage batteries (AA)
with charger
• PC software for reading the stored test data
• creation of test logs with handover and status report
according to ZVEH
• structuring and export function of the test data
Additional functions
BENNING IT 120 B
in addition to the BENNING IT 110 :
• testing of universal current-sensitive RCDs of type B
• current measurement (TRUE RMS) by means of current
clamp adapter (optional)
• illumination measurement by means of lux sensor (optional)
• earthing measurement by means of three-wire measuring
method (optionally with earthing set)
• integrated measured value memory for 500 measurements
• USB and RS 232 interface
• BENNING PC-Win IT 120 B software included in delivery
Test log to
g
accordin
ZVEH
Scope of delivery of the BENNING IT 120 B
AddIn for Mebedo
test software
ELEKTROmanager
and fundamed
INFORMATION:
rsal
of unive
Testing ensitive
s
current- type B
f
o
s
D
RC
IT 120 B
BENNING IT 120 B
Installation Testers
BENNING
IT 120 B
display
graphic display (illuminated)
low-impedance resistance
0.01 Ω – 2000 Ω
insulation resistance
1 kΩ – 1000 MΩ
line impedance (L-N/L)
0.01 Ω – 2000 Ω
loop impedance (L-PE)
0.01 Ω – 2000 Ω
short-circuit current
0.01 A – 24.4 kA
RCD testing
tripping time, tripping current,
type AC, A, B
contact voltage
phase sequence
yes
voltage, frequency
1 V – 500 V, 45 Hz – 65 Hz
earth resistance
0.01 Ω – 2000 Ω
current (TRUE RMS)
0.1 mA – 20 A (by means of the clamp)
luminous intensity
0.01 lux – 20 klux (by means of sensor)
measured value memory
500 measuring results
interfaces
USB, RS 232
incl. software
BENNING PC-Win IT 120 B
item no.
044102
RCDs of type B are increasingly used for multi-phase
equipment of power electronics. In case of a fault,
these devices also detect
smooth DC fault currents
and high-frequency AC fault
currents.
BENNING CC 2
Scope of delivery of the installation testers
tester incl. carrying case / carrying strap
switchable probe tip
test cable with shock-proof plug
universal test cable, 3 x L = 1.5 m
3 x test probe, 3 x crocodile clips
charger with 6 NiMH storage batteries (AA)
PC software BENNING PC-Win IT 120 B
USB and RS 232 cable
BENNING
IT 110
x
x
x
x
x
x
BENNING
IT 120 B
x
x
x
x
x
x
x
x
BENNING luxmeter
type B
Optional accessories for BENNING IT 120 B
current clamp adapter BENNING CC 2
0.5 A – 20 A AC (200 A AC)
item no. 044110
illumination sensor BENNING luxmeter type B
Accuracy: 5 %
item no. 044111
earthing set consisting of 2 earth rods and 3 test cables
(2 x L = 20 m, 1 x L = 4.5 m)
item no. 044113
Earthing set
BENNING World Class Test Equipment
14
BENNNG PV 1-1 installation tester for photovoltaic systems
Commissioning tests and periodic inspection of PV systems
BENNING PV 1-1
PV installation tester for testing
grid-connected PV systems
• tests in compliance with VDE 0126-23 (DIN EN 62446)
standard
• easy – operation by means of keys with AUTO test procedure
• quick – testing within a few seconds only
• safe – contacting by means of PV connectors
Measured values transmitted
via wireless connection
Application
For commissioning tests and periodic inspection of grid-connected PV systems according to VDE 0126-23. Meets all
requirements necessary for system documentation of the
DC side. Ideal for troubleshooting, maintenance work and
performance evaluation of PV systems.
Features of the BENNING PV 1-1
• easy and safe operation by means of keys
• automatic test procedure for polarity, open-circuit voltage,
short-circuit current and insulating resistance
• RISO measurement with “PASS/FAIL” indication
• memory of measured values for 200 PV strings
• integrated real-time clock with date/time stamp for each
measurement
• USB interface and download software for the preparation of
test certificates in MS Excel®
• safe contacting even during energy supply of the PV system
• direct connection by means of MC4 and “Sunclix” connectors
Measuring functions
• continuity test of the protective conductor and of the
equipotential bonding conductor with a testing current of
200 mA
• polarity test of the DC current cables
• open-circuit voltage for each PV string of up to 1000 VDC
• short-circuit current for each PV string of up to 15 ADC
• insulating resistance with a testing voltage of 250 V, 500 V
and 1000 VDC
• DC string current and AC current by means of BENNING CC 3
current measuring clamp up to 40 A AC/DC (optional)
Radio interface “Wireless SUN Link”
• wireless connection to the insolation and temperature
measurement instrument BENNING SUN 2 (optional)
• direct display of the insolation value in W/m2
• storage of the electric quantities to be measured considering the insolation and the module/ambient temperature in
real time
BENNING PV 1-1
Installation tester for photovoltaic systems
display
protective conductor
resistance
insulating resistance
open-circuit voltage
with polarity
short-circuit current
DC string current/
AC current
insolation
BENNING PV 1-1
scope of delivery
BENNING
PV 1-1
graphic display (illuminated)
0.05 Ω – 199 Ω
0.2 MΩ – 199 MΩ
BENNING CC 3
BENNING TA 5
5 V to 1000 V DC
0.5 A to 15 A DC
0.2 A to 40 A DC/AC
(by means of BENNING CC 3)
100 to 1250 W/m2
(by means of BENNING SUN 2)
PV module/ambient
-30 °C to +125 °C
temperature
(by means of BENNING SUN 2)
voltage via 4 mm sockets
30 to 440 V AC/DC
Interface/radio interface
1 x USB/433 MHz signal
dimensions/weight
270 x 115 x 55 mm/2.6 kg
scope of delivery
carrying case, measuring lines,
alligator clips, MC4 and “Sunclix”
PV measuring lines, batteries, USB cable,
download software on CD-ROM
item no.
050421
Optional accessories for
BENNING PV 1-1
Current clamp adapter BENNING CC 3 for AC/DC current measurement
0.2 to 300 A AC/DC
item no. 044038
Measuring line BENNING TA 5 for protective conductor measurement
Line length: 40 m
item no. 044039
BENNING World Class Test Equipment
15
Insolation and temperature measuring instrument BENNING SUN 2
with digital compass and inclinometer
BENNING SUN 2
Insolation and temperature measuring instrument
for PV systems and solar thermal systems
Ideal for the planning, commissioning tests and periodic
inspection of grid-connected PV systems according to
VDE 0126-23 as well as for testing solar thermal systems.
Measuring functions
• insolation measurement in W/m2 or BTU/h/ft2
• dual-channel temperature sensor for measuring the module
temperature and the ambient temperature
• digital compass for determining the cardinal direction
• inclinometer for determining the module/roof pitch
Features of the BENNING SUN 2
• universal 4-in-1 measuring instrument for all testing and
maintenance work as well as for economic efficiency analysis
• temperature-compensated PV reference cell for precise insolation measurement
• precise temperature measurement by means of high-precision sensors
• data logger for 5000 data records, including insolation and
module/ambient temperature
• integrated real-time clock with date/time stamp
• USB interface and download software for the preparation of
test certificates in MS Excel®
• data logger with energy-saving stand-by mode
• shock-absorbing protective rubber holster
Radio interface – “Wireless SUN Link”
• wireless transmission of insolation, module temperature
and ambient temperature including date/time stamp to the
BENNING PV 1-1
Insolation, angle of inclination
and compass bearing
Wireless transmission of measuring data
(alternatively import of measuring data by means of date/time stamp)
BENNING SUN 2
Insolation and temperature measuring instrument
display
insolation
PV module/ambient
temperature
compass bearing
(orientation)
angle of inclination
measurement
real-time clock
measured value memory
interface/radio range
dimensions/weight
scope of delivery
item no.
BENNING
SUN 2
graphic display
100 to 1250 W/m2
Insolation, PV module/ambient temperature
s
ort form
Test rep of PV systems”
ation
“Examin ee under
fr
nning.de
www.be
-30 °C to +125 °C
0° to 360°
0° to 80°
date/time stamp
5000 data records for insolation
and temperature
1 x USB/approx. 30 m for unobstructed
view conditions
150 x 80 x 33 mm/350 g
case, protective rubber holster,
module/ambient temperature sensor,
battery set, USB cable,
download software on CD-ROM
050420
BENNING SUN 2
scope of delivery
BENNING World Class Test Equipment
16
Demonstration case for practice-oriented application
of testers, measuring instruments and safety instruments
tion
r informa
For furthe r website
visit ou
ing.de
www.ben
BENNING DB 1
Demonstration case for testing and measuring
primary quantities of electrical engineering
BENNING DB 2
Demonstration case for practice-oriented application
and training concerning VDE 0100 installation testers
n
particularly suited for teaching and
education purposes, training courses
and product presentations
portable case for simulation of electrical
systems conforming to standards
according to DIN VDE 0100/105
Demonstration case
Demonstration case
BENNING DB 1
230 V, 50/60 Hz mains connection
405 x 330 x 160 mm, approx. 6 kg
case with mains connection cable
044132
power supply
dimensions/weight
scope of delivery
item no.
BENNING DB 2
230 V, 50/60 Hz mains connection
450 x 330 x 110 mm, approx. 4.5 kg
case with mains connection cable
044133
power supply
dimensions/weight
scope of delivery
item no.
Recommendation for the workshop equipment for enterprises of electrical engineer-craft
according ZVEH and VDEW guidelines (Electricity Association)
Required test and
measurement
Two-pole voltage tester
Voltage (min. 600 V) and
current meter (min. 15 A)
Clip-on ammeter
(min. 300 A)
Insulation tester
Loop ohmmeter
Ohmmeter
FI/RCD-meter
Phase sequence indicator
Tester/meter
complying with standard
DIN VDE 0682-401
IEC/EN 61243-3
DIN VDE 0411-1
IEC/EN 61010-1
DIN VDE 0411-1
IEC/EN 61010-1
DIN VDE 0413-2
IEC/EN 61557-2
DIN VDE 0413-3
IEC/EN 61557-3
DIN VDE 0413-3
IEC/EN 61557-4
DIN VDE 0413-6
IEC/EN 61557-6
DIN VDE 0413-7
IEC/EN 61557-7
Single unit
version I
DUSPOL® analog
item no. 050261
MM 2
item no. 044028
CM 2
item no. 044035
IT 101
item no. 044033
DIN VDE 0404-1
DIN VDE 0404-2
Instrument for testing
electrical equipment
(DIN VDE 0701-0702, 0751-1)
Additional recommendation ZVEH
Grounding gauge
Continuity tester
Light meter lux meter
DIN VDE 0413-6
IEC/EN 61557-6
DIN VDE 0413-7
IEC/EN 61557-7
–
Additional recommendation of BENNING
Differential current clamp for
DIN VDE 0411-1
error current determination in
IEC/EN 61010-1
electric equipment and systems
Single unit/device combination Single unit/device combination
version II
version III
DUSPOL® expert
DUSPOL® digital
item no. 050262
item no. 050263
MM 1-3 + CC 1
MM 7-1 + CC 1
item no. 044084 + 044037
item no. 044085 + 044037
CM 5-1
CM 8
item no. 044066
item no. 044064
–
IT 101
item no. 044033
IT 110
item no. 044100
IT 120 B
item no. 044102
ST 710
item no. 050308
ST 720
item no. 050312
ST 750 A
item no. 050320
–
–
Earthing set for IT 120 B
item no. 044113
–
TRITEST ®
item no. 020050
DUTEST ®
item no. 050155
–
–
Luxmeter type B for IT 120 B
item no. 044111
CM 9
item no. 044065
CM 9
item no. 044065
CM 9
item no. 044065
BENNING World Class Test Equipment
Voltage and Continuity Tester
17
Phase-Sequence Indicator
PROFIPOL®
Voltage Testers for universal applications
DUTEST ®
Continuity and line tester
• indicating DC and AC voltage within the
range of 6 – 400 V
• indicating steps 6, 12, 50, 120, 230, 400 V
• polarity test for DC voltage
• shock-proof housing made of rugged highpressure PE material
• compact dimensions and increased grip
• dustproof and waterproof, protection
category IP 65
• reliable detection of faulty wiring, contact-
ing errors and cable interruptions
• quick localization of defective fuses, lamps,
lines and short-circuits
• indication of high-impedance (0 – 90 kΩ)
and low-impedance (0 – 900 Ω) resistances
• acoustic indication by means of loud testing
buzzer
• visual indication by means of high-contrast
light-emitting diodes (LED)
• powerful torch function
• protected against external voltages of up to 400 V
TRITEST ® control
Phase-sequence indicator for testing
the phase sequence in three-phase
mains
• indication of clockwise and anti-clockwise
phase sequence
• indication of phase voltages (L1, L2, L3) by
means of high-contrast LEDs
• voltage range: 400 – 690 V (50 – 60 Hz)
• bright LED pocket lamp function
• including safety probe tips and alligator clip
tested and
approved
IEC/EN 61010-1
(DIN VDE 0411-1)
PROFIPOL®
DUTEST ®
TRITEST ® control
item no. 020022
item no. 050155
item no. 020050
Tips for practical use
• Always observe the five safety rules for “working under voltage”!
• For determining the absence of voltage on electrical systems of up
to 1000 V, only use two-pole voltage testers complying with the
current IEC/EN 61243-3 standard.
• Always check voltage testers for correct functioning immediately
before and after use.
• Voltage testers with connectable load suppress capacitively and
inductively induced voltages. Thus, incorrect measurements are
excluded!
• Standard-compliant voltage testers must comply at least with
protection category IP 54.
• DUSPOL® voltage testers are designed for safe working under
voltage. Operating errors due to incorrect measuring range
selection are excluded. The handles with grip limit offer the highest
safety possible and sufficient distance to the measuring object. The
display is arranged directly in the user's field of vision.
• A standards-compliant design of a voltage tester/measuring instrument is confirmed by independent testing and certification institutes
by granting a mark of conformity (e.g. VDE/GS mark of conformity).
• Digital multimeters and current clamps with TRUE RMS measuring
method offer increased accuracy in case of distorted and nonsinusoidal signal characteristics in industrial use.
• Please take into consideration the high-impedance input resistance
(~10 MΩ) of a digital multimeter which indicates capacitively and
inductively induced voltages and which very often might only simulate the existence of voltage.
• Use digital multimeters and current clamps only for the area of application for which they are designed. The measuring inputs must
be marked unambiguously with the measuring category (CAT I –
CAT IV) and the maximum nominal voltage to earth.
Measuring categories CAT I to CAT IV:
distribution
CAT I
CAT II
CAT III
meter
CAT IV
overhead line
outside
building
substation
earthing cable
BENNING World Class Test Equipment
18
Accessories for BENNING testers and measuring instruments
safe – functional – indispensable
Hard-top case for testers and measuring instruments
item no. 711020
DUSPOL® stand-by case
High-quality hard-top case with foam insert and three compartments for professional storage of testers and measuring
instruments.
Compartment dimensions: approx. 110 x 300 x 50 mm,
Case dimensions: approx. 450 x 380 x 110 mm
Practical stand-by case with Velcro fastener and belt loop
made of hard-wearing nylon fabric suitable for DUSPOL®
digital, DUSPOL® expert and DUSPOL® analog.
Dimensions: 330 x 100 x 60 mm
item no. 010911
BENNING TA 1
item no. 044124
Ø 4 mm safety crocodile clips, two pieces, red/black,
professional equipment, CAT III 1000 V
BENNING TA 2
item no. 044125
set of Ø 4 mm safety measuring leads, six pieces,
red/black, professional equipment, consisting of:
• safety measuring leads (silicone), CAT III 1000 V
• safety test probes (4 mm measuring tip), CAT II 1000 V
• safety crocodile clips, CAT III 1000 V
BENNING TA 3
item no. 044126
set of Ø 4 mm safety measuring leads, eight pieces,
red/black, professional equipment, CAT III 1000 V,
consisting of:
• safety measuring leads (silicone)
• safety test probes (slender measuring tip)
• safety claw clamps
• safety crocodile clips
BENNING TA 4
item no. 044120
magnetic holder for Multimeter and
BENNING IT 101, 3 pieces, consisting of:
• magnetic holder
• adapter and belt, for attachment of
BENNING Multimeters to switching
cabinets, machine and system parts
Ø 4 mm safety measuring leads
with 2 mm measuring tip
item no. 044146
Ø 4 mm safety measuring leads 2 pieces,
red/black, L = 1.40 m, with 2 mm
measuring tip CAT IV 600 V/
CAT III 1000 V (with protective caps),
CAT II 1000 V (without protective caps)
Ø 4 mm safety measuring leads
with 4 mm measuring tip
BENNING TA 5
item no. 044039
40 m measurement cable with practical winder, strap, for the
measurement of protective and bonding conductors,
Connection: Ø 4 mm safety test
item no. 044145
Ø 4 mm safety measuring leads 2 pieces,
red/black, L = 1.40 m, with 4 mm
measuring tip CAT IV 600 V/
CAT III 1000 V (with protective caps),
CAT II 1000 V (without protective caps)
Set of safety measuring leads for BENNING MM 4
item no. 044119
Temperature probe (type K)
set of Ø 4 mm safety measuring leads, 3 pieces,
consisting of:
• safety measuring leads with 2 mm measuring tip
• 2 measuring probes with 2 mm measuring tip
insertion probe (V4A steel tube) for flexible substances,
liquids, gases and air, measuring range:
-196 °C to +800 °C, suitable for BENNING MM 1-3, MM 7-1,
MM 11 and CM 8 digital measuring instruments
item no. 044121
BENNING World Class Test Equipment
19
Measuring adapters for BENNING ST 710/ST 720/ST 750 A
appliance testers and BENNING CM 9 leakage current clamp
Measuring adapters for BENNING ST 710/ST 720/ST 750 A
Measuring adapters for single-phase loads (passive)
for measuring RPE, RISO and IEA, CEE coupling (3-pin) with
shock-proof plug
16 A CEE (3-pin)
item no. 044143
32 A CEE (3-pin)
item no. 044144
for ST 710/720/750 A
Measuring adapters for three-phase loads (passive)
for measuring RPE, RISO and IEA, CEE coupling (5-pin) with
shock-proof plug
16 A CEE (5-pin)
item no. 044122
32 A CEE (5-pin)
item no. 044123
for ST 710/720/750 A
Measuring adapter for single-phase and three-phase
loads (passive)
for measuring RPE, RISO and IEA, triple CEE coupling with
shock-proof plug
Triple CEE coupling: 16 A CEE (5-pin), 32 A CEE (5-pin),
16 A CEE (3-pin)
item no. 044147
for ST 710/720/750 A
Measuring adapter for BENNING ST 710/ST 720
Shock-proof plug with 4 mm plug for appliances without
shock-proof plug
item no. 044142
for ST 710/720
Measuring adapters for BENNING ST 720 (active)
Measuring adapters for three-phase loads for measuring
RPE and IPE (direct measurement method) by means of current
transformer, CEE (5-pin) with shock-proof plug
16 A CEE (5-pin)
item no. 044140
32 A CEE (5-pin)
item no. 044141
for ST 720
Measuring adapters for BENNING CM 9 leakage current
clamp (active)
for measuring the differential/protective conductor/load current,
conductors led through individually, with double insulation
Single-phase,
shock-proof plug/coupling
item no. 044131
Three-phase,
16 A CEE (5-pin)
32 A CEE (5-pin)
item no. 044127
item no. 044128
for CM 9
for CM 9
(test sample working)
BENNING CM 9 leakage current clamp
indication= ID
ID = IPE + IL
©
for measuring the differential/protective conductor/load current
of single-phase and three-phase loads (1 µA to 100 A AC)
(see page 7)
item no. 044065
IPE
IL Leakage current e.g. via
the water conduit and
capacity of the washing
machine to earth
BENNING World Class Test Equipment
20
Professional VDE seminars
Service hotline with 24h service
VDE 0701-0702 seminar
Testing of electrical appliances/equipment
VDE 0100 seminar
Testing of electrical installations of up to 1000 V
Features:
The seminar addresses qualified electricians, competent
persons as well as electrotechnically trained persons who have
to do the testing and its documentation according to the DIN
VDE 0701-0702 standard for repaired or modified electrical
devices or the repetitive testing of electrical devices.
The participants of the seminar will be given an intensive
training in order to be able to do this inspection according to
regulations considering the optimum use of the BENNING
ST 710/ST 720/ST 750 A testers as well as of the BENNING
PC-Win ST 750 logging software. At the end of the seminar,
the participants will get a certificate of attendance.
Features:
The seminar addresses qualified electricians who have to do
the testing and its documentation of electrical installations of
up to 1000 V according to the DIN VDE 0100 standard.
The participants of the seminar will be given an intensive
training in order to be able to do this inspection independently
and according to regulations considering the optimum use of
the BENNING IT 101/IT 110/IT 120 B testers as well as of the
BENNING PC-Win IT 120 B logging software. At the end of the
seminar, the participants will get a certificate of attendance.
free
e
2 4 h s e r v ic
ne:
Service Hotli - 555
/93
+49 (0) 28 71
Testing, measuring and safety instruments
The whole range of testers from one supplier
Factory II, Robert-Bosch-Straße 20, D-46397 Bocholt
Your distributor:
Developing safe and practical testing and measuring instruments which comply with the relevant standards is an
integral part of BENNING’s product philosophy for more than
65 years now. Today, BENNING offers a comprehensive product range of high-quality testing, measuring and safety
devices the quality requirements of which are orientated
according to the demands of professional users. With the
generation of DUSPOL® voltage testers and with the measuring and safety devices, BENNING sets pioneer standards
worldwide concerning safety, functionality and design.
BENNING Elektrotechnik und Elektronik GmbH & Co.KG
Münsterstraße 135-137 • D-46397 Bocholt
Tel.: + 49 / (0) 2871 / 93-420 • Fax: + 49 / (0) 2871 / 93-429
www.benning.de • E-Mail: [email protected]
784331.31 GB 04/2013 paus Design & Medien, Bocholt Subject to technical changes.
Content:
Regulations, testing of the AC side, testing of the DC side (polarity test, open-circuit voltage, short-circuit current, insulating
resistance and operating current measurement for each PV
string of the PV generator) as well as minimum requirements
for system documentation in compliance with VDE 0126-23.
Printed on non-chlorine bleached paper.
Content:
Regulations, definitions, measurements (insulation, continuity
Content:
of the protective conductor, loop impedance/line impedance,
Regulations, definitions, measurements (continuity of the pro- short-circuit current, FI/RCD testing, earthing, rotary field,
tective conductor, insulation, protective conductor current/con- voltage, frequency), management of measuring data and docutact current), test sample management and documentation mentation according to ZVEH.
according to ZVEH.
Seminar venue:
BENNING GmbH & Co. KG,
VDE 0126-23 seminar
Robert-Bosch-Straße 20, 46397 Bocholt
Testing of grid-connected photovoltaic systems
Seminar dates:
to be agreed upon
Features:
Seminar fee:
We are happy to make you an offer:
phone +49 (0) 28 71/93 - 470
The seminar is intended for qualified electricians who have to
4 or 6.5 hours
carry out commissioning tests and periodic inspection of grid- Duration:
connected photovoltaic systems in compliance with the Scope of services: Intensive training in small groups of up
to 6 persons, training material, certifiVDE 0126-23 standard. The participants of the seminar will be
cate of attendance and refreshments
given an intensive training in order to be able to do this inspecduring the seminar
tion according to regulations considering the optimum use of
the photovoltaic tester BENNING PV 1-1 as well as of the inso- We are pleased to send you our directions and to recommend to
lation and temperature measuring instrument BENNING SUN 2. you hotels in direct vicinity of the seminar venue.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project