www.osram.com Preliminary Datasheet Benefits

www.osram.com Preliminary Datasheet Benefits
www.osram.com
LINEARlight POWER – LR21P overall module
Preliminary Datasheet
Benefits
 Broad portfolio (Eco, Advanced, Power) with the same form
factor offering high variety in luminous flux and color
temperatures while being simply exchangeable
 Modules can be joined together in series to make seamless
strip lighting, without any further accessory
 Intermateable with LINEARlight Colormix Advanced & Eco
 Low maintenance costs thanks to a lifetime of up to 50k hours
 Module efficacy up to 73 lm/W
Application
 General lighting
 Furniture / shelf lighting
 Cove lightning
Technical Operating Data
Product
LR21P-W2F-830-L30
Color
Number of
Voltage
Power
[V]*
[W]*
Radiance
Angle [°]*
Color
Temp. [K]
Lum. Flux
LEDs
typ. [lm]
Lum. Intensity
typ. [cd]
21
24
7.8
30
3000
570
1700
White
LR21P-W2F-840-L30
White
21
24
7.8
30
4000
570
1700
LR21P-W2F-830-L70
White
21
24
7.8
70
3000
570
400
LR21P-W2F-840-L70
White
21
24
7.8
70
4000
570
400
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data
*) Preliminary Data
Technical Features
 Module equipped with 21 LEDs, adapted heat sink
and intergrated optics with 30° or 70°
 Mounting by optional clips LT-MB-KiT or LT-KiT
 Seamless concept with up to 6 modules in series
 Metal core PCB
 Lifetime 50.000 h @L70 @tcmax 65°C
 Luminous flux 2050 lm/m
 Best efficiency in combination with OSRAM
 Intergrated SMD-4Pin plug connector
(male/female) on both module sides
OPTOTRONIC® 24 V control gear
(recommended control gears see page 2)
 Optional endcaps ensure strain relief function in
 Fine white Binning
combination with CONNECTsystem LR-4x
 Ra typ. 85
 Connecting cables (CONNECTsystem LR-4x) as
(see page 4)
well as endcaps optional available (see page 4)
LINEARlight Power LR21P
31.10.2012
Page 1 von 4
www.osram.com
Minimum and Maximum Ratings
Product
Operating Temperature
LR21P-W2F
Storage Temperature
[C°]*
Voltage Range
Reverse Voltage
at Tc-Point [C°]*
[V dc]*
[V dc]*
-30 … 65
-30 … 90
23 … 25
25
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a
temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below.
Drawing
l
285 mm
b
36 mm
h
13 mm
l1
13,3 mm
Driver
OPTOTRONIC
LED Module
Moduls
LINEARlight
POWER
Power lm/m
7,8 W
2250
2050
OT8
200-240/24
OT20 (S)
200-240/24
OT50*
200-240/24
OT75 (E)
200-240/24
OTi Dali 75
220-240/24
1 module
Module
2 modules
Modules
3 - 5 modules
Modules
3 - 6 modules
Modules
3 - 6 modules
Modules
280 mm
560 mm
840 - 1400 mm
840 - 1680 mm
840 - 1680 mm
630 lm
1260 lm
1890 - 3150 lm
1890 - 3780 lm
1890 - 3780 lm
Light Management Systems
LED Module
LINEARlight
POWER
Power
lm/m
OT DIM
OTi DALI DIM
OTi DALI DIM LI
7,8 W
2250
2050
66Modules
modules
6 modules
Modules
66Modules
modules
LINEARlight Power LR21P
31.10.2012
OT DMX 3x2.5A OT DMX 9x2A DIM
DIM
SO
Page 2 von 4
3x6 modules
Modules
9x4 modules
Modules
www.osram.com
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage of the path on the circuit board the plastic washer should be inserted between
the screw head and circuit board while the assembly with using of metal screws and plastic washers.
Alternatively, the use of plastic screws is possible.
 To avoid mechanical damage to the connecting cables, the module should be attached securely to the
intended substrate. Heavy vibration should be avoided.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilised power supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark
and be ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information").
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical
and safety standards. Only qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be
destroyed! Correct polarity immediatelly! (see "reverse voltage", page 2).
 Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not
recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Pay attention to ESD steps when mounting the module.
 Asymmetrical voltage drops can cause a strong overload and destruction of single modules.
 Use only LR-4PIN CONNECTsystem for electrical installation. Three types of connectors are available: LR4PIN - Feeder with 500 mm cable length. LR-4CONN-45 - Connector for through wiring with 45 mm cable
length. LR-4CONN-250 Connector for through wiring with 250 mm cable length.
 The LED module can typically survive levels of up to 4 Amperes. As a general design precaution, if the
maximum output current of th power supply is more than 4 Amperes, fast-blow fuses should be incorporated
into the wiring plan.
 Electrical contact is achieved with the contact cables. A maximum number of 6 modules can be installed
consecutively from one power feed. Operation with more than 6 consecutive modules will reduce photometric
performance and exceed the current carrying capacity of the module.
 While installation of up to 8 modules on one OPTOTRONIC® 75W .middle feeding has to be done.
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against
corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide
suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
 If the IP assessment of the device should be higher than IP20, the design of the mounting should be
accordingly to IP standards while the application.
 It’s recommended that a person cannot look direct for a long time in the light by a distance of 30cm or less.
LINEARlight Power LR21P
31.10.2012
Page 3 von 4
www.osram.com
Mounting Information
 The housing of LINEARlight Power is already an optimal heat sink. Another heat sink is not required.
 Alternatively two mounting brackets LT MB can be used for the fastening. When the holding clamp are
mounted on the desired place, the module can be fasten with snapping (not suitable for vertical mounting).
 To connect one module, the feeder LR-4PIN-500 must be plugged in the "INPUT" side of the module.
While mounting of two or more boards please connect the “OUTPUT” side of the first board with the
“INPUT” side of the following board using plug connector LR-4CONN-45 / -250. Please connect all the
other possible modules as described above.
Ordering Number
Product group
Product
EAN*
S-Unit*
LINEARlight POWER 30°
LR21P-W2F-830-L30
4008321 971630
8
LINEARlight POWER 30°
LR21P-W2F-840-L30
4008321 971654
8
LINEARlight POWER 70°
LR21P-W2F-830-L70
4008321 978707
8
LINEARlight POWER 70°
LR21P-W2F-840-L70
4008321 978721
8
CONNECTsystem feeder
LR-4PIN-500
4008321 971852
16
CONNECTsystem
LR-4CONN-45
4008321 971814
16
CONNECTsystem
LR-4CONN-250
4008321 994400
16
LINEARlight Track end caps
LT-ENDCAP
4008321 976109
16
LINEARlight Track Mounting bracket
LD-MB
4008321 225672
16
LINEARlight Track KiT
LT-Kit
4008321 813404
40
*) EAN: Ordering number per single module
S-Unit: Modules per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM AG
Hellabrunner Strasse 1
D - 81536 München Germany
www.osram.com
+49 (0)89 6213-0
Sales and technical support is given by the local
OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete address
and phone numbers.
Related and Further Information
 A new approach to light
153 S006 GB
 OSRAM LED Systeme
www.osram.de/led-systeme
 OPTOTRONIC® Technical Guide
130 T008 DE www.osram.de/evg-downloads
 OPTOTRONIC® Datasheets
http://catalog.myosram.com
 Eulumdat Files
www.osram.de/led-systeme-downloads
 New standards for LED control gear
LINEARlight Power LR21P
www.osram.de/evg-downloads
31.10.2012
Page 4 von 4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement