TESTO Precision digital thermometer (NTC and Pt100) Owner's Manual
Testo Precision digital thermometer (NTC and Pt100) is a compact instrument for measuring temperatures in indoor environments, ideal for food and laboratory sectors. It features a clear display, interchangeable probes (NTC and Pt100), Bluetooth connectivity for use with the testo Smart App, and configurable alarm thresholds. Data can be frozen, and max/min values are tracked. Multi-point and continuous mean calculations are supported. The device offers various settings adjustable via the device itself or the app, including units, alarm settings and auto-off.
PDF
Download
Document
Advertisement
Advertisement
testo 110 – Temperature meter for NTC and Pt100 0560 0110 Instruction manual Contents Contents 1 2 2.1 About this document ...........................................................................3 Safety and disposal..............................................................................3 Security ..................................................................................................3 2.2 Disposal .................................................................................................4 3 4 5 5.1 Product-specific information...............................................................5 Intended use .........................................................................................5 Product description .............................................................................6 Instrument overview ...............................................................................6 6 6.1 First steps .............................................................................................7 Inserting / changing batteries .................................................................7 6.2 Getting to know the product ...................................................................8 6.2.1 Connecting probes .................................................................................8 6.2.2 Switching the instrument on and off .......................................................8 6.2.3 Switching the display illumination on and off ..........................................8 6.3 Establishing a Bluetooth® connection .....................................................9 6.3.1 Establishing a Bluetooth® connection to the testo Smart App ..............10 7 7.1 Using the product...............................................................................11 Controls on the measuring instrument..................................................11 7.1.1 Implementing settings ..........................................................................12 7.1.2 Opening configuration mode ................................................................13 7.1.3 Setting the unit .....................................................................................13 7.1.4 Setting alarm thresholds.......................................................................14 7.1.5 Setting the alarm sound .......................................................................14 7.1.6 Carrying out a reset of the setting menus.............................................14 7.1.7 Carrying out a reset of the measuring instrument.................................14 7.2 Measuring ............................................................................................15 7.2.1 Freezing a reading, displaying the maximum/minimum value ..............15 7.2.2 Resetting maximum/minimum values ...................................................15 7.2.3 Carrying out multi-point mean calculation ............................................15 7.2.4 Carrying out continuous mean calculation............................................16 7.3 Printing data .........................................................................................17 8 8.1 Controls via testo Smart App ............................................................18 Overview of operating controls .............................................................18 8.2 App options ..........................................................................................20 Contents 8.2.1 Setting the language ............................................................................ 20 8.2.2 Displaying App Info .............................................................................. 20 8.2.3 Displaying the tutorial .......................................................................... 20 8.3 Application menus ............................................................................... 21 8.3.1 Selecting an application menu ............................................................. 21 8.3.2 Setting favourites ................................................................................. 21 8.3.3 Displaying information about an application ........................................ 21 8.4 Making measuring instrument settings ................................................ 22 8.4.1 Configuring the measuring instrument menu ....................................... 24 8.4.2 Setting Auto Off ................................................................................... 25 8.4.3 Activating damping .............................................................................. 25 8.4.4 Configuring alarms............................................................................... 26 8.4.5 Setting the surface increment .............................................................. 26 8.5 Display of the readings ........................................................................ 27 8.6 Adjusting the view ................................................................................ 27 8.7 Exporting readings ............................................................................... 28 8.7.1 Excel (CSV) Export .............................................................................. 28 8.7.2 PDF Export .......................................................................................... 29 8.8 Perform Firmware update .................................................................... 30 9 9.1 Maintaining the product .................................................................... 31 Inserting / changing batteries ............................................................... 31 9.2 Cleaning the instrument ....................................................................... 31 10 11 11.1 Technical data for testo 110.............................................................. 32 Tips and assistance........................................................................... 34 Questions and answers ....................................................................... 34 11.2 Accessories and spare parts................................................................ 35 11.2.1 Compatible NTC probes ...................................................................... 35 11.2.2 Compatible Pt100 probes (digital)........................................................ 35 1 About this document 1 About this document • The instruction manual is an integral part of the instrument. • Keep this documentation to hand so that you can refer to it when necessary. • Always use the complete original instruction manual. • Please read this instruction manual through carefully and familiarize yourself with the product before putting it to use. • Hand this instruction manual on to any subsequent users of the product. • Pay particular attention to the safety instructions and warning advice in order to prevent injury and damage to the product. 2 Safety and disposal 2.1 Security General safety instructions • Only operate the product properly, for its intended purpose, and within the parameters specified in the technical data. • Do not apply any force. • Do not operate the instrument if there are signs of damage to the housing or connected cables. • Dangers may also arise from objects to be measured or the measuring environment. Always comply with the locally valid safety regulations when carrying out measurements. • Do not store the product together with solvents. • Do not use any desiccants. • Only perform maintenance and repair work on this instrument that is described in this documentation. Follow the prescribed steps exactly when doing the work. • Use only original spare parts from Testo. Batteries • Improper use of batteries may cause the batteries to be destroyed, or lead to injury due to current surges, fire or escaping chemicals. • Only use the batteries supplied in accordance with the instructions in the instruction manual. • Do not short-circuit the batteries. • Do not take the batteries apart and do not modify them. 3 2 Safety and disposal • Do not expose the batteries to heavy impacts, water, fire or temperatures in excess of 60 °C. • Do not store the batteries in the proximity of metal objects. • In the event of contact with battery acid: rinse affected areas thoroughly with water, and if necessary consult a doctor. • Do not use any leaky or damaged batteries. Warnings Always pay attention to any information denoted by the following warnings. Implement the precautionary measures specified! DANGER Risk of death! WARNING Indicates possible serious injury. CAUTION Indicates possible minor injury. CAUTION Indicates possible damage to equipment. 2.2 Disposal • Dispose of faulty rechargeable batteries and spent batteries in accordance with the valid legal specifications. • At the end of its useful life, deliver the product to the separate collection point for electric and electronic devices (observe local regulations) or return the product to Testo for disposal. • 4 WEEE Reg. No. DE 75334352 3 Product-specific information 3 Product-specific information • Do not carry out measurements on live components. • Do not expose handles and feed lines to temperatures in excess of 70°C unless they are expressly approved for higher temperatures. Temperature specifications on probes/sensors refer only to the measuring range of the sensor system. • Only open the measuring instrument if this is expressly described in the documentation for the purposes of maintenance or servicing. 4 Intended use The testo 110 is a compact measuring instrument for measuring temperatures. It is intended for indoor use only. The product is designed for the following tasks/areas: • Food sector • Laboratory sector The product should not be used in the following areas: • In potentially explosive atmospheres • For diagnostic measurements in the medical field The following product components are designed for continuous contact with foodstuffs in accordance with Regulation (EC) 1935/2004: from the tip of the measuring probe up to 1 cm before the probe handle or the plastic housing. If provided, the information about penetration depths in the instruction manual or the mark(s) on the measuring probe should be noted. 5 5 Product description 5 Product description 5.1 Instrument overview 1 Control keys 3 Socket for NTC or Pt100 type probe with TUC connector 5 Battery compartment Explanation of icons Refer to instruction manual 6 2 Display 4 Speaker for alarm sound 6 First steps 6 First steps c Inserting / changing batteries 6.1 WARNUNG Serious risk of injury to the user and/or destruction of the instrument. There is a risk of explosion if the batteries are replaced with ones that are the wrong type. - Only use non-rechargeable alkaline batteries. The instrument is switched off. 1 Open the battery compartment (on the back of the instrument) via the snap lock. 2 Insert or replace batteries (3 x AA alkaline batteries). Observe the polarity! 3 + - + Close the battery compartment. When not in use for a long period: Take out the batteries. Symbol explanation Do not allow children under 6 years of age to play with batteries. Do not throw batteries in the trash. Do not charge batteries. Do not place batteries near fire. Batteries are recyclable. 7 6 First steps 6.2 Getting to know the product 6.2.1 Connecting probes Plug-in probes can be connected via the probe socket(s) on the head of the instrument. 1 6.2.2 Plug the probe's connector into the measuring instrument’s probe socket. Switching the instrument on and off Switching on 1 Press the On/Off key (0.5 sec). Measurement view is opened: The current reading is displayed or ----- lights up if no reading is available. Switching off 1 Press and hold down (2 sec) the On/Off key. The display turns off. 6.2.3 Switching the display illumination on and off The measuring instrument is switched on. 1 Press and hold down (2 sec) the MENU/ENTER key. The display illumination is switched on or off. 8 6 First steps Establishing a Bluetooth® connection 6.3 The instrument can be connected to the testo Smart App via Bluetooth® connection The measuring instrument is switched on. To enable the Bluetooth® connection for the first time, press and hold (approx. 2 sec) the ◄ key. While the instrument is trying to establish a Bluetooth® connection, the icon flashes on the display. Bluetooth® remains enabled until it is disabled manually by pressing and holding (approx. 2 sec) the ◄ key. The measuring instrument saves the Bluetooth® setting and, depending on the configuration, starts up with Bluetooth® enabled or disabled. 9 6 First steps 6.3.1 Establishing a Bluetooth® connection to the testo Smart App To establish a connection via Bluetooth®, you need a tablet or smartphone with the Testo Smart App already installed on it. You can get the App for iOS instruments in the App Store or for Android instruments in the Play Store. Compatibility: Requires iOS 13.0 or later/Android 8.0 or later, requires Bluetooth® 4.2. Bluetooth® is enabled in the measuring instrument. 1 Open the testo Smart App. The app automatically searches for Bluetooth® devices in the vicinity. 2 In the Sensors menu, check whether the required instrument is connected. If necessary, switch the instrument to be connected off and on again to restart the connection module. When the testo Smart App is connected to the measuring instrument, the icon appears on the measuring instrument display. The measuring instrument automatically synchronizes its date and time settings with the testo Smart App. Once connected successfully, the current measured value from the measuring instrument appears on the app screen in the Live view. 10 7 Using the product 7 Using the product Controls on the measuring instrument 7.1 The instrument is switched on. The testo Smart App is installed on the smartphone and connected to the instrument via Bluetooth®. Settings and controls are implemented either on the instrument or via the app. If the measuring instrument is connected to the testo Smart App, settings can only be made via the app. The measuring instrument then remains in the measurement view and other menus, e.g. Settings, cannot be opened. 1 2 On/Off / MODE/END key Bluetooth® / ◄ key 3 Battery indicator 4 Selected unit 5 Current measured value 6 Print / ► key 7 Illumination / MENU/ENTER key 11 7 Using the product Implementing settings 7.1.1 Selecting, opening and setting functions 1 Press the relevant key to select the functions Secondary assignment (long press) All keys with a grey corner have a secondary assignment, which can be selected by pressing and holding the key for a longer time (2 sec). Adjustable functions Ensure correct settings: all settings are transferred immediately. There is no Cancel function. Function Setting options/comments Bluetooth® (long press) Switch the Bluetooth® connection on or off Arrow left Freeze reading (HOLD function), display maximum/minimum value. On/Off (long press) In configuration mode: Decrease value, select option Switches the instrument on or off MODE/END Select or end multi-point or continuous mean calculation. Display illumination (long press) OFF (display illumination not active) or ON (display illumination active) 12 7 Using the product Function Setting options/comments MENU/ENTER Open configuration mode Start continuous measurement / record multi-point readings (Operation also possible directly on measuring instrument if it is connected to the app) Print (long press) Arrow right 7.1.2 In configuration mode: Confirm input Output readings via external printer In configuration mode: Increase value, select option Opening configuration mode The instrument is switched on and is in the measurement view. 1 Press MENU/ENTER until the display changes. The instrument is now in configuration mode. MENU/ENTER to switch to the next function. You can leave Press configuration mode at any time. To do this, press MODE/END until the instrument has changed to the measurement view. Any changes that have already been made in configuration mode will be saved. 7.1.3 Setting the unit Configuration mode is open, “UNITS” is displayed. 1 Press ◄ / ► to choose between metric (“METR”) and imperial (“IMPER”) units of measurement and confirm with MENU/ENTER. The currently set unit flashes. 2 Press ◄ / ► to set the required unit and confirm with MENU/ENTER. 13 7 Using the product Setting alarm thresholds 7.1.4 Configuration mode is open, “ 1 Press ◄ / ► to set the lower alarm threshold value and confirm with MENU/ENTER. “ 2 7.1.5 min” is displayed. max” is displayed. Press ◄ / ► to set the upper alarm threshold value and confirm with MENU/ENTER. Setting the alarm sound Configuration mode is open, “ 1 Press ◄ / ► to enable/disable the alarm sound (“ON” / “OFF”) and confirm with MENU/ENTER. 7.1.6 Carrying out a reset of the setting menus Configuration mode is open, “M. RES” (menu reset) is displayed. 1 Press ◄ / ► to select the required option and confirm with MENU/ENTER: o o ” is displayed. NO: Do not carry out reset. YES: Carry out reset. All concealed menus that were hidden via the testo Smart App are displayed again. The instrument returns to measurement view. 7.1.7 Carrying out a reset of the measuring instrument Configuration mode is open, “RESET” is displayed. 1 Press ◄ / ► to select the required option and confirm with MENU/ENTER: o o NO: Do not carry out reset. YES: Carry out reset. The instrument is reset to the factory settings. The instrument returns to measurement view. 14 7 Using the product Measuring 7.2 The instrument is switched on and is in the measurement view. 1 Put the probe into position and take the readings. With the alarm function on and if the alarm threshold is exceeded or undershot: • Alarm icon flashes and a signal tone is emitted until any key is pressed. • An arrow symbol at the bottom left indicates whether the upper or lower 7.2.1 alarm threshold has been exceeded or undershot. Freezing a reading, displaying the maximum/minimum value The current reading can be frozen. The maximum and minimum values since the last time the instrument was switched on in the standard view or during a multi-point or continuous measurement can be displayed. 1 Press ◄ several times until the desired value is displayed. The following are displayed in turn: o Hold: frozen measured value o Max: Maximum value o Min: Minimum value o Current measuring value 7.2.2 Resetting maximum/minimum values The maximum/minimum values of all channels can be reset to the current reading. 1 Press ◄ several times until Max or Min is shown. 2 Hold down ◄ (approx. 2 s). All maximum and minimum values are reset to the current reading. 7.2.3 Carrying out multi-point mean calculation 1 Press MODE/END. flashes. 15 7 Using the product The number of readings recorded is displayed in the upper line, while the current reading is displayed in the lower line. 2 To record readings (in the desired quantity): Press MENU/ENTER (several times). 3 To end measurement and calculate the mean value: Press MODE/END. and flash. The number of measured values and the calculated multi-point mean value are displayed. 4 To switch back to the measuring view: Press MODE/END. 7.2.4 1 Carrying out continuous mean calculation Press MODE/END twice. The elapsed measuring time (mm:ss) is displayed in the upper line, while the current reading is displayed in the lower line. 2 Start measurement: flashes. Press MENU/ENTER. 3 To interrupt/continue measurement: Press MENU/ENTER each time. 4 To end measurement and calculate the mean value: Press MODE/END. 16 and flash. 7 Using the product The measurement period and the calculated continuous mean value are displayed. 5 To switch back to the measuring view: Press MODE/END. Printing data 7.3 A testo Bluetooth®/IRDA printer (order no. 0554 0621) is connected via Bluetooth and switched on. When first setting up a connection between the testo measuring instrument and the testo Bluetooth®/IRDA printer, the initialization phase can last up to 30 seconds. 1 Press and hold ► to transfer the data to the printer. Data is printed out (LED on the printer lights up green). 1 Instrument name 3 Date and time of printout 5 Measurment values 2 Firmware version and serial number 4 Measuring type and measured duration 6 Measurement parameters 17 8 Controls via testo Smart App 8 Controls via testo Smart App If the measuring instrument is connected to the testo Smart App, it is primarily operated via the app. The measuring instrument remains in the measurement view and settings menus cannot be opened on the measuring instrument. 8.1 Overview of operating controls 1 Choice of applications 3 Display of connected measuring instruments including readings Measurement configuration (the menu changes depending on the 5 measuring instrument connected and the application selected) 18 2 Switch between the views (live, graphic, table) 4 Start/stop 6 Configuration of the measuring instrument 8 Controls via testo Smart App Additional symbols on the user interface of the app (not numbered) One level back Exit view Share measurement data/report Searching Favourite Deleting Further information Display report Multiple selection The Main menu can be accessed via the icon at top left. To exit the main menu, select a menu or right-click on the guided menus. The last screen displayed is shown. Measure Customer Memory Sensors Settings Help and Information Other applications 19 8 Controls via testo Smart App 8.2 App options 8.2.1 Setting the language 1 Click on 2 Select Settings. 3 Select Language. . A selection list is displayed. 4 Select the required language. The language is changed. 8.2.2 Displaying App Info In App Info you can find the version number of the installed App. 1 Click on 2 Select Help and Information. 3 Select Instrument information. The version number of the app and the ID are displayed. 8.2.3 . Displaying the tutorial The tutorial guides you through the first steps in operating the testo Smart App. 1 Click on 2 Select Help and Information. . The tutorial is displayed. In the tutorial, swipe to display the next page. 3 20 Click X to quit the tutorial. 8 Controls via testo Smart App 8.3 Application menus 8.3.1 Selecting an application menu 1 Click on A selection of menus for various applications is displayed. 2 Select the required application. . Your selected application is displayed. 8.3.2 Setting favourites 1 Click on A selection of menus for various applications is displayed. 2 Select the application you want to set as a favourite. 3 Click on The star is displayed in orange: 8.3.3 1 . . . Displaying information about an application Click on . A selection of applications is displayed. 2 Click on . The information about an application is displayed. 21 8 Controls via testo Smart App Making measuring instrument settings 8.4 The measuring instrument is connected to the testo Smart App. 1 Click on . The main menu opens. 2 Click on Sensors. The Sensors menu opens. 3 Click on the required measuring instrument. Information about the model, order number, serial number and firmware version is displayed. 4 Click on the Settings tab. A window with settings for the respective measuring instrument opens. In addition to the settings that can be performed on the measuring instrument, additional settings can also be made. 22 8 Controls via testo Smart App 5 Click on the blue text under a settings heading to activate or disable settings or to open an input window to enter a specific value or select a unit. For details on the settings options, see the following sub-sections. Changes to the measuring instrument settings in the app are transferred directly to the measuring instrument. Synchronization with the app is confirmed on the measuring instrument via “SYNC DONE”. 23 8 Controls via testo Smart App 8.4.1 Configuring the measuring instrument menu The testo Smart App can be used to set which settings menus should be available or hidden on the measuring instrument itself. The Settings tab in the Sensors menu is open. 1 - Activate Customization instrument menu and click on the blue text Change instrument menu list under the settings heading. The Customization instrument menu dialogue opens. On the measuring instrument, the following menus can be displayed or hidden: o Configuring alarms o Alarm sound on/off o Setting the unit o Pitot tube factor (testo 512-1 only) o Absolute pressure (testo 5121 only) 24 8 Controls via testo Smart App 2 Deactivate the checkboxes for the measuring instrument menus that are no longer to be displayed on the measuring instrument itself. The menus belonging to the deactivated entries will no longer be displayed in the measuring instrument menu after the next synchronization. These settings can be reset via the menu reset “M.RES” and then all settings menus will be displayed on the measuring instrument again. 8.4.2 Setting Auto Off The Settings tab is open. 1 Enable Activate Auto-off using the slider. The measuring instrument switches off automatically if no key is pressed for 10 min. Exception: a frozen reading is shown on the display (“Hold” is displayed). 8.4.3 Activating damping If the readings fluctuate wildly, it is advisable to damp the readings. The Settings tab is open. 1 Enable Activate damping using the slider. 2 Click on Average of the measured values. 25 8 Controls via testo Smart App The window for Average of the measured values opens. 3 Enter a value between 2 and 20 measured values. Changes to the measuring instrument settings in the app are transferred directly to the measuring instrument. Synchronization with the app is confirmed on the measuring instrument via “SYNC DONE”. 8.4.4 Configuring alarms The standard view with the LIVE tab is open. 1 2 Click on . Select Alarm configuration. The menu with the overview of alarms that can be activated opens. 3 Click on the checkbox to activate a specific alarm. 4 Click on EDIT. The input window for activating and defining upper and lower warning and alarm values is displayed. 5 Click OK to confirm the settings. Changes to the measuring instrument settings in the app are transferred directly to the measuring instrument. Synchronization with the app is confirmed on the measuring instrument via “SYNC DONE”. 8.4.5 Setting the surface increment Surface probes withdraw heat from the measured surface immediately after the initial contact. As a result, the measurement result is lower than the actual surface temperature without the probe (the reverse is true for surfaces that are colder than the probe). This effect can be corrected by an increment in % of the reading. The Settings tab is open. 26 1 Activate Surface increment using the slider. 2 Enter the value for the surface increment and confirm with OK . 8 Controls via testo Smart App changes are transferred to the measuring instrument and The synchronization with the app is confirmed on the measuring instrument via “SYNC DONE”. Display of the readings 8.5 The available readings can be displayed in different views. • Live view: The readings transmitted by the measuring probes can be displayed in a live view. Readings from all connected measuring probes are displayed. • Graphic view: Up to four different readings can be displayed in graph format. Readings to be displayed can be selected by tapping on a reading above the diagram. • Table view: In the table view, all readings are displayed in sequence according to date and time. Different readings from the individual measuring probes can be displayed by pressing ◄ ►. Adjusting the view 8.6 1 2 Click on . Select Edit view. overview of all measurement channels and their measurement An parameters is displayed. 3 Deselect the “check mark” to hide a measuring instrument’s measurement channel. 4 Click ▼ to select the unit of a measurement channel. 5 Click OK to confirm the settings. 27 8 Controls via testo Smart App Exporting readings 8.7 Export Delete Report 1 Click on 2 Select Memory. 3 Click on Select measurement. 8.7.1 Excel (CSV) Export 1 Click on . . A selection of export options is displayed. 2 Click on Start export. A selection of sending/export options is displayed. 3 28 Select the required sending/export options. 8 Controls via testo Smart App 8.7.2 PDF Export 1 Click on Report. A selection window is displayed. 2 If required, activate the Create PDF with all readings button. 3 Click on Create. For measurements, please be aware that the option Create PDF with all readings is only possible up to 30 pages, due to the resulting file size and number of pages. In the testo DataControl software, however, PDF reports can be created for all measurements without any restrictions. A report containing all the information is created. selection window is displayed. The report can be sent via e-mail or ABluetooth . ® 4 Click on E-mail or Bluetooth®. The report will be sent. c 29 8 Controls via testo Smart App Perform Firmware update 8.8 Ensure that the option for Enable update for connected instruments in Instrument Information is always enabled. If a new firmware is available for your measurement instrument, an update notification is shown after connecting the instrument with the testo Smart App. 1 Click Start Update to perform the update. If you click Later, the Update notification is shown again during the next connection. During the instrument update the Bluetooth connection must not be disconnected. The update needs to be performed completely and takes approx. 5-10 minutes depending on the used smartphone. 30 9 Maintaining the product After the update the measuring instrument is restarting. The firmware can be checked in the instrument menu or via the app. A restart of the testo Smart App is recommended after the instrument update. 9 Maintaining the product c Inserting / changing batteries 9.1 WARNUNG Serious risk of injury to the user and/or destruction of the instrument. There is a risk of explosion if the batteries are replaced with ones that are the wrong type. - Only use non-rechargeable alkaline batteries. The instrument is switched off. 1 Open the battery compartment (on the back of the instrument) via the snap lock. 2 Insert or replace batteries (3 x AA alkaline batteries). Observe the polarity! 3 + - + Close the battery compartment. When not in use for a long period: Take out the batteries. 9.2 Cleaning the instrument 1 If the housing of the instrument is dirty, clean it with a damp cloth. Do not use any aggressive cleaning agents or solvents! Mild household cleaning agents and soap suds may be used. 31 10 Technical data for testo 110 10 Technical data for testo 110 Feature Value Measurement parameters °C, °F Accuracy Operating temperature NTC: ±0.2 °C (-20 to +80 °C) ±0.3 °C (other ranges) Pt100: according to digital probe NTC: 0.1 °C Pt100: according to digital probe NTC: -50 to +150 °C Pt100: -200 to +800 °C -20 to +50 °C Storage temperature -20 to +50 °C Operating humidity 0 to 80 %RH / For indoor use only IP class IP20 (with connected probe IP40) Level of contamination PD2 Max. operating altitude ≤ 2000 m above sea level Nominal output 2 W @ 4,5 V DC Battery type Battery life 3 x 1.5 V AA battery (included in the scope of delivery) >100 h Dimensions 135 x 60 x 28 mm Weight 187 g Resolution Measuring range 32 10 Technical data for testo 110 With Topsafe (0516 0224) and the following probes, this product complies with guidelines in accordance with the EN 13485 standard: Part no. Measuring range 0572 2163 0615 1212 0615 1712 0618 0071 0618 0072 0618 0073 0618 0275 -40 ... +85 °C -40 ... +150 °C -40 ... +125 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C Suitability: S, T (storage, transport) Environment: E (transportable thermometer) Accuracy class: 0.5 Measurement range: see table above According to EN 13485, the measuring instruments should be checked and calibrated regularly under the terms of EN 13486 (Recommended: Yearly). Contact us for more information: www.testo.com 33 11 Tips and assistance 11 Tips and assistance 11.1 Questions and answers Question Possible cause Possible solution is displayed (top right on the display) Instrument switches itself off Instrument battery is almost spent Replace instrument battery Display responds sluggishly Display: ----Display: OOOOO Display: UUUUU Display: BT Fail Display: Print Fail • Auto Off function is switched on • Switch off Auto Off function • Remaining battery capacity is insufficient • Change the battery. Ambient temperature is very low Sensor error Increase ambient temperature Please contact your dealer or Testo Customer Service. Permissible measuring Keep within the permissible range has been exceeded measuring range Permissible measuring Keep within the permissible range has been undershot measuring range • Check Bluetooth® Bluetooth connection connections. could not be established Printout could not be performed successfully Display: Probe Fail Probe damage Display: OTA Fail The update process "over the air" of the measuring instrument could not be completed successfully. Connection to the testo Smart App was interrupted. Keys are locked for 3 s. Display: APP Lost 34 • Restart measuring instrument, restart testo Smart App. • Check Bluetooth® connections, switch off and then on again if necessary. • Switch printer off and then on again. Please contact your dealer or Testo Customer Service. Restart the measuring instrument and testo Smart App and check the Bluetooth® connection. Restart the measuring instrument and testo Smart App and check the Bluetooth® connection. 11 Tips and assistance If we have not been able to answer your question: please contact your local dealer or Testo Customer Service. See the back of this document or the www.testo.com/service-contact web page for contact details. 11.2 Accessories and spare parts Description Order no. Bluetooth®/IRDA printer Topsafe protective case 0554 0621 0516 0224 For a complete list of all accessories and spare parts, please refer to the product catalogues and brochures or visit our website www.testo.com 11.2.1 Compatible NTC probes Description Order no. Waterproof immersion/penetration probe – with NTC temperature sensor Robust air probe – with NTC temperature sensor Temperature probe with Velcro and NTC temperature sensor Clamp probe with NTC temperature sensor – for measurements on pipes (Ø 6-35 mm) Pipe wrap probe with NTC temperature sensor – for measurements on pipes (Ø 5-65 mm) Stub temperature probe (digital) - with NTC temperature sensor 0615 1212 0615 1712 0615 4611 0615 5505 0615 5605 0572 2162 11.2.2 Compatible Pt100 probes (digital) Description Order no. High-precision immersion/penetration probe with Pt100 temperature sensor Immersion/penetration probe with Pt100 temperature sensor Air temperature probe with Pt100 temperature sensor Flexible immersion probe with Pt100 temperature sensor and flexible PTFE probe tube Laboratory probe with Pt100 temperature sensor in glass tube (Duran 50), resistant to aggressive media WBGT-Pt100 probe for ambient temperature WBGT-Pt100 probe for wet bulb temperature Temperature cable probe with Pt100 temperature sensor Pt100 special probe 0618 0275 0618 0073 0618 0072 0618 0071 0618 7072 0618 0070 0618 0075 0572 2163 0618 9999 35 Testo SE & Co. KGaA Celsiusstr. 2 79822 Titisee-Neustadt Germany Phone: +49 (0)7653 681-0 E-mail: [email protected] www.testo.com 0970 9110 en 01 - 12.2022 ">
Advertisement
Key features
- Bluetooth connectivity
- Interchangeable probes (NTC & Pt100)
- Alarm thresholds
- Data logging & analysis
- Mean value calculation
Frequently asked questions
Ensure Bluetooth® is enabled on the instrument (long press the ◄ key). Open the testo Smart App, which will automatically search for nearby Bluetooth® devices. The app will show if it's connected; if not, try restarting the instrument.
Enter configuration mode (press MENU/ENTER). Select "UNITS" and use the ◄/► keys to choose between metric and imperial, confirming with MENU/ENTER.
Press ◄ until 'Max' or 'Min' is displayed. Then, hold down ◄ for approximately 2 seconds to reset.
Press MODE/END to initiate. Press MENU/ENTER to record each reading; press MODE/END again to stop and view the calculated mean.
A testo Bluetooth®/IRDA printer (order no. 0554 0621) is required. Connect it via Bluetooth. Press and hold ► to transfer.