Keysight Technologies M9393A PXIe Performance Vector Signal Analyzer Configuration Guide 02 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide Overview This configuration guide contains information to help you configure your Keysight Technologies, Inc. M9393A PXIe performance vector signal analyzer (PXIe performance VSA) and tailor a system to meet your requirements. Table of contents Page number Hardware A: Select options for M9393A PXIe performance VSA......................................................... 3 B: Add related modules.......................................................................................................... 3 C: Select controller................................................................................................................. 4 D: Select a chassis & accessories.......................................................................................... 6 Physical connection diagram for controllers, chassis & accessories Software E: Select software for M9393A PXIe performance VSA....................................................... 8 Services F: Select services: Warranty, calibration, start-up assistance............................................ 10 Configuration Single M9393A PXIe performance VSA.................................................................................. 11 Single PXIe performance VSA (M9393A) in chassis.............................................................. 11 Multiple PXIe performance VSAs in a single chassis............................................................. 11 Other Upgrading your system............................................................................................................ 12 Using an M9393A in a non-Keysight chassis......................................................................... 12 PC requirements for M9393A control..................................................................................... 12 Related literature..................................................................................................................... 12 03 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide A. Select options for M9393A PXIe performance VSA Step 1. Start with M9393A PXIe performance VSA base configuration The M9393A PXIe performance VSA base configuration (occupies 4 slots) includes: M9308A M9365A M9214A PXIe synthesizer PXIe downconverter PXIe IF digitizer –– Frequency range 9 kHz - 8.4 GHz –– Analysis bandwidth 40 MHz –– Memory 128 MSa (512 MB) –– One day start-up assistance –– Modular interconnect cables –– Return to Keysight warranty - 3 years Step 2. Choose a frequency range M9393A-F08 9 kHz − 8.4 GHz M9393A-F14 9 kHz − 14 GHz M9393A-F18 9 kHz − 18 GHz M9393A-F27 9 kHz − 27 GHz M9393A-FRX 3.6 GHz - 50 GHz Included in base configuration Requires option F27. (M9169E recommended - see next section) Step 3. Choose an analysis bandwidth M9393A-B04 40 MHz M9393A-B10 100 MHz M9393A-B16 160 MHz Included in base configuration Step 4. Choose memory size M9393A-M01 128 MSa M9393A-M05 512 MSa M9393A-M10 1024 MSa Included in base configuration Step 5. Add additional capability (optional) M9393A-UNZ Fast tuning Accelerates test throughput and stepped spectrum analysis M9393A-WB1 Wideband IF output Enables up to 800 MHz IF output from the downconverter (M9202A recommended - see next section) Step 6. Add pre-amplifier (optional) Enhances sensitivity to detect low-level signals M9393A-P08 9 kHz − 8.4 GHz M9393A-P14 9 kHz − 14 GHz M9393A-P18 9 kHz − 18 GHz M9393A-P27 9 kHz − 27 GHz B. Add related modules Step 1. Add an M9300A PXIe frequency reference (occupies 1 slot) One frequency reference required per chassis to meet data sheet specifications. It can support up to four M9393A PXIe VSAs M9393A-300 Adds M9300A PXIe frequency reference Five 100 MHz outputs One 10 MHz output Internal 10 MHz OCXO timebase output Step 2. Add M9169E for use with option FRX (occupies 2 slots) Enables measurements of signals with > -20 dBm power automated alignments and self-test M9169E PXI switchable-input programmable step attenuator module, DC to 50 GHz Step 3. Add M9202A for use with option WB1 (occupies 1 slot) Provides digitization of 800 MHz wideband IF output from downconverter module M9202A PXIe 12-bit wideband IF digitizer (recommended options: C01, F02, M05, DDC, and V05 or V10) 04 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide C. Select controller (either embedded controller or via PC) Step 1. If selecting an embedded controller, select either M9036A or M9037A1 M9036A-M04 Mid-performance embedded controller Intel i5-520E dual-core, 2.4 GHz, 4 thread, 4GB RAM Select the M9036A for mid-performance, lower cost or if your application requires XP operating system M9037A-M04 High-performance embedded controller Intel i7-4700EQ quad-core processor, 2.4 GHz, 8 thread, 4GB RAM Select M9037A for the best performance if you have memory intensive applications, multiple applications running in parallel, or if a lot of data is sent to the PC from the PXIe chassis. Features removable SSD drive for security and x8 connector from front for connection to second chassis Step 2. Upgrade from standard memory size (optional) For M9036A M9036A-M08 Memory upgrade from 4 GB to 8 GB RAM For M9037A M9037A-M08 Memory upgrade from 4 GB to 8 GB RAM M9037A-M16 Memory upgrade from 4 GB to 16 GB RAM Step 3. Select an operating system For M9036A M9036A-WE3 Microsoft Windows Embedded Standard 7 (32-bit) M9036A-WE6 Microsoft Windows Embedded Standard 7 (64-bit) For M9037A M9037A-WE3 Microsoft Windows Embedded Standard 7 (32-bit) M9037A-WE6 Microsoft Windows Embedded Standard 7 (64-bit) 1. The M9018A 18-slot chassis includes empty space to the left of the 1st functional slot. The embedded controller occupies that empty space and the 1st functional slot. 05 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide C. Select controller (either embedded controller or via PC) (continued) To use your Laptop PC as a controller M9045B PCIe® ExpressCard adaptor Y1200B PCIe cable M9021A PCIe cable interface1 : 1 slot To use your Desktop PC as a controller M9048A PCIe desktop adaptor Y1202A PCIe cable M9021A PCIe cable interface1 : 1 slot 1. The M9021A is used for either PC control option and can only be used with the Keysight M9018A 18-slot chassis. 06 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide D. Select a chassis and accessories Step 1. Select a chassis M9018A 18-slot PXIe chassis Step 2. Choose enough slot blocker kits and EMC filler panels to fill every open slot Recommended to achieve data sheet specifications Y1212A Slot blocker kit: 5 slots Y1213A PXI EMC filler panel kit: 5 slots Step 3. Choose a rack mount kit (optional) Y1215A Rack mount kit for M9018A 18-slot PXIe chassis Step 4 Choose an air inlet kit (optional) Recommended for rack mounted systems with less than 1U space below chassis. Y1214A Air inlet kit: M9018A 18-slot chassis1 1. Available in 1-slot, 2-slot or 3-slot options depending on the chassis configuration. For more information, please visit www.keysight.com/find/m9018a 07 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide Physical Connections Physical connection diagram for controllers 08 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide E. Select software for M9393A PXIe performance VSA Step 1. Start with M9393A base configuration The M9393A comes standard with the following software: –– Keysight IO Libraries Suite including Connection Expert1 –– Instrument software, soft front panel, drivers for use with MATLAB, LabVIEW, Visual Studio (including VB Net, C#, C/C++), Keysight VEE 2 –– Sample waveforms and programming examples Step 2. Download free Keysight Command Expert software 3 (optional) FREE software that provides fast and easy instrument control for the PC. Command Expert combines instrument command sets, command sequences, documentation, syntax checking and command execution in one simple interface. Command Expert helps you to: –– Find instrument commands –– Access command documentation –– Verify command syntax –– Build instrument command sequences –– Execute instrument command sequences –– Integrate sequences in MATLAB, Visual Studio, Excel, LabVIEW, Keysight VEE or Keysight SystemVue PC application environment –– Generate code for command sequences in MATLAB, Visual C#, Visual Basic.NET and Visual C/C++ –– Profile command execution time –– Debug command sequences using breakpoints and single stepping Step 3. Add X-Series Measurement Applications for Modular Instruments 4 (optional) Provides essential RF conformance measurements and tasks for specific communications standards. Transportable, perpetual licenses support up to 4 modular VSAs in one chassis. M9080A/B LTE FDD, LTE-Advanced FDD M9082A/B LTE TDD, LTE-Advanced TDD M9073A W-CDMA/HSPA+ M9071A GSM/EDGE/EVO M9079A TD-SCDMA/HSPA M9076A 1xEV-D0 M9072A cdma2000 ®/cdmaOne M9077A WLAN 802.11a/b/g/n/ac M9081A Bluetooth® M9063A Analog modulation M9064A VXA vector signal analysis M9068A Phase noise 1. Both IO library (version 16.3 or newer) and Connection Expert software need to be installed on the PC controlling the equipment. To download, visit www.keysight.com/find/iosuite 2. Find latest versions of this software at www.keysight.com/find/m9393a 3. To download or get more information on Command Expert, visit www.keysight.com/find/commandexpert 4. For more information, see “Accelerate PXI VSA Measurements with X-Series Measurement Applications”, literature number 5991-2604EN. 09 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide E. Select sofware for M9393A PXIe performance VSA (continued) Step 4. Add 89600 VSA Software1 (optional) Provides time, spectrum and stepped spectrum mesaurements, powerful displays, data recording and playback, links to MATLAB and more. 89601B-200 89600 VSA software - basic and hardware connectivity Measurement options 89601B-SSA Spectrum analysis2 89601B-AYA General purpose vector modulation analysis with over 30 types of presets 89601B-BHF Custom OFDM modulation analysis of propriety and pre-standard OFDM formats 89601B-B7R WLAN 802.11a/b/g/j/p 89601B-B7Z WLAN 802.11n MIMO 89601B-BHJ WLAN 802.11ac MIMO (requires 89601B-B7Z) 89601B-BHD LTE FDD 89601B-BHG LTE-Advanced FDD (requires 89601B-BHD) 89601B-BHE LTE TDD 89601B-BHH LTE-Advanced TDD (requires 89601B-BHE) 89601B-B7T cdma2000®/cdmaOne 89601B-B7U W-CDMA/HSPA+ 89601B-B7W 1xEV-DO 89601B-B7X TD-SCDMA 89601B-B7R 3G Bundle (includes cdma2000®, W-CDMA/HSPA+, 1xEV-DO & TD-SCDMA options) 89601B-BHC RFID 89601B-BHK Custom IQ modulation analysis (requires 89601B-AYA) 89601B-BHL Channel quality measurements 89601B-BHM DOCSIS 3.1 modulation analysis 89601B-BHP FMCW radar analysis 89601B-BHQ Pulse analysis 1. For more information, see 89600 VSA software configuration guide literature number 5990-6386EN. 2. For best speed, M9393A-UNZ and -B16 are recommended. 10 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide F. Select services: Warranty, calibration, start-up assistance One day start-up assistance Included in base configuration Return to Keysight warranty - 3 years Included in base configuration R-51B-001-5Z Return to Keysight warranty - 5 years M9393A-UK6 Commercial calibration certificate with test data for M9393A (M9308A, M9365A, M9214A) Calibration certificate with measurement results available only at time of purchase. M9300A-UK6 Commercial calibration certificate with test data for M9300A Calibration certificate with measurement results available only at time of purchase. R-51B-001-3X Express warranty - 5 day turnaround For 3 years Available in the US, Japan, China and many EU countries R-51B-001-5X Express warranty - 5 day turnaround For 5 years Available in the US, Japan, China and many EU countries N7800A Calibration and adjustment software Global warranty Keysight Technologies, Inc. provides the peace of mind that today’s high tech industry requires. Your investment is protected by Keysight’s global reach in more than 100 countries (either directly or through distributors). The warranty gives you convenient standard coverage for the country in which the product is used, eliminating the need to ship equipment back to the country of purchase. Keysight’s warranty service provides: –– All parts and labor necessary to return your investment to full specified performance –– Recalibration for products supplied originally with a calibration certificate –– Return shipment Express warranty Reduce downtime with the fastest repair service in the industry. The express warranty upgrades the global warranty to provide: –– 5 day typical turnaround repair service in the US, Japan, China and many EU countries or up to a 10 day improvement in turnaround time in the rest of the world –– Priority return shipment One day start-up assistance A Keysight Technologies applications engineer will get you started quickly by helping you install the modules in a chassis, configure the controller, load software and start making measurements. Calibration services The modular products are factory calibrated and shipped with an ISO-9002, NIST-traceable calibration certificate. A one year calibration cycle is recommended. The M9393A PXIe performance VSA is supported by the Keysight N7800A calibration software to perform calibrations that test all product specifications and is compliant with ISO 17025:2005, ANSI/NCSL Z540.3-2006 and measurement uncertainty per ISO Guide to Expression of Measurement Uncertainty 1995. N7800A calibration & adjustment software The M9393A PXIe performance VSA is supported by Keysight’s calibration and adjustment software. This is the same software used at Keysight’s service centers to automate calibration. The software offers compliance tests for ISO 17025:2005, ANSI/NCSL Z540.3-2006, and measurement uncertainty per ISO Guide to Expression of Measurement Uncertainty. Product Information: www.keysight.com/find/contactus Or call: 1 800 829-4444 US Repair and Calibration: www.keysight.com/find/infoline Parts and Accessories: www.parts.keysight.com For all modular products: www.keysight.com/find/modular 11 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide Configuration Please see the M9393A startup guide for detailed cabling diagram and parts list. Single M9393A PXIe performance VSA Standard M9393A configuration provides frequency coverage up to 27 GHz Extended frequency M9393A configuration with M9169E module provides frequency coverage up to 50 GHz Single M9393A PXIe performance VSA in chassis Single M9393A PXIe performance VSAs in a single chassis Multiple M9393A PXIe performance VSAs in a single PXIe chassis Up to four M9393As can be installed in a single M9018A 18-slot PXIe chassis. The M9393As also share a single M9037A PXIe embedded controller or external PC. Four M9393As in a single M9018A chassis. It is recommended that you install the M9393A modules entirely in consecutive slots beginning with slot 2 when using the M9018A chassis. Additional instructions for configuring M9018A PXI backplane triggers are included in the M9393A startup guide, literature number M9393-90002. A Keysight M9018A PXIe chassis is required for MIMO capability and 89600 VSA software is required for MIMO analysis. 12 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide Upgrading your system Your product can be easily upgraded after the initial purchase. Most PXIe VSA options are controlled by a licensing key and can be quickly upgraded by the user. How to upgrade your M9393A PXIe performance VSA: 1. Contact your Keysight representative to place an order for an option upgrade. 2. For frequency upgrades, return your PXI VSA to a Keysight Service Center 3. For all other upgrades you will receive your hardware entitlement certificate via email. 4. Redeem the certificate online by following the instructions provided to receive a license key file. 5. Install the license key file using the Keysight License Manager. 6. Begin using the new capability. Using a non-Keysight chassis The M9393A (with M9300A frequency reference) can be successfully installed in a non-Keysight PXI chassis. Please use the following guidelines. –– Ensure that the chassis has 4 consecutive PXIe or PXI-H slots which can be used by the M9393A (6 slots if using M9169E) and an additional slot for M9300A. –– Ensure that the chassis and controller supports peer-to-peer PXI Express I/O switch topology. –– Ensure that controller selected is compatible with chassis. Please contact your Keysight representative for more detailed information. For technical assistance with non-Keysight equipment, please refer to the equipment manufacturer’s website. PC requirements for M9393A PXIe performance VSA control 1 Windows 7 Operating system Windows 7 (32 & 64 bit) Processor speed 1.5 GHz dual core (x86 or x64) minimum, 2.4 GHz recommended No support for Itanium64 Available memory 4 GB minimum 8 GB recommended Available disk space 1.5 GB available hard disk space includes: 1 GB for Microsoft.NET framework 4.0 100 MB for Keysight IO libraries suite Video Support for DirectX 9 graphics with 128 MB graphics recommended (SuperVGA supported) Browser Microsoft Internet Explorer 7.0 or greater 1. For a list of computers compatible with the Keysight PXIe M9018A chassis, refer to Tested Computer Technical Note (literature no. 5990-7632EN) Related literature For more detailed product and specification information refer to the following literature and web pages: –– M9018A PXIe 18 slot Chassis Data Sheet (literature no. 5990-6583EN) –– M9037A PXIe High Performance Embedded Controller Data Sheet (literature no. 5991-3661EN) –– M9036A PXIe Embedded Controller Data Sheet (literature no. 5990-8465EN) 13 | Keysight | M9393A PXIe Performance Vector Signal Analyzer - Configuration Guide From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939. 1939 THE FUTURE myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a full one-year warranty on all accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. “PCIe” and “PCI EXPRESS” are registered trademarks and/or service marks of PCI-SIG. cdma2000 is a registered certification mark o f the Telecommunications Industry Association. Bluetooth and the Bluetooth logos a re trademarks owned by Bluetooth SIG, Inc., USA and licensed to Keysight Technologies, Inc. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-28-15) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System www.keysight.com/find/M9393A This information is subject to change without notice. © Keysight Technologies, 2015 Published in USA, October 22, 2015 5991-4580EN www.keysight.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement