Solar charge controller Shine05 User Manual
Dear Clients,
Thanks for selecting the Shine series solar controller. Please take the time to read this user manual, this will help you to make full
use of many advantages the controller can provide your solar system.
This manual gives important recommendations for installing and using and so on. Read it carefully in your own interest please.
3.Dimensions
1.Description of Function
83mm
Shine series solar controller is especially for solar home
INFO
CHARGE
system, with better cost-effective.
49mm
34.5mm
It comes with a number of outstanding features,
such as:
Low cost and high reliability design
12V system voltage
Clear readable display of charge/discharge and error
φ4mm
90mm
description
2.Safety instructions and waiver of liability
18
Temperature compensation
Four stage charge way: fast, boost, equalization, float
Full automatic electronic protect function
4.Installation
The following diagrams provide an overview of the
connections and the proper order.
2.1 Safety
INFO
CHARGE
①The solar charge controller may only be used in PV
systems in accordance with this user manual and the
specifications of other modules manufacturers. No energy
source other than a solar generator may be connected to
the solar charge controller.
②Batteries store a large amount of energy, never short
circuit a battery under all circumstances. We strongly
③
④
①
②
⑤ ⑥
recommend connecting a fuse directly to the battery to
protect any short circuit at the battery wiring.
To avoid any voltage on the wires, first connect the wire to
③Batteries can produce flammable gases. Avoid making
the controller, then to the battery, panel or load.
sparks, using fire or any naked flame. Make sure that the
Make sure the wire length between battery and controller
battery room is ventilated.
is as short as possible.
④Avoid touching or short circuiting wires or terminals. Be
Recommended minimum wire size: 1.5 mm².
aware that the voltages on special terminals or wires can
Be aware that the positive terminal of Shine are connected
be as much as twice the battery voltage. Use isolated
together and therefore have the same electrical potential.
tools, stand on dry ground, and keep your hands dry.
If any grounding is required, always do this on the positive
⑤Keep children away from batteries and the charge
wires.
controller.
Connecting capacitive load may trigger short circuit
protection.
2.2 Liability Exclusion
5.Starting up the controller
The manufacturer shall not be liable for damages,
especially on the battery, caused by use other than as
intended or as mentioned in this manual or if the
recommendations of the battery manufacturer are
neglected. The manufacturer shall not be liable if there has
been service or repair carried out by any unauthorized
person, unusual use, wrong installation, or bad system
design.
5.1Self Test
As soon as the controller is supplied with battery, it
starts a self test routine. Then the display changes to
normal operation.
5.2System Voltage
The controller is 12V system voltage. As soon as the
battery voltage at the time of start-up is within 10V to 15V,
the controller implies a 12V system.
If the battery voltage is not within the normal operating
rang at start-up, a status display according to the section
Error description occur.
5.3Battery Type
The controller applies to Liquid battery.
Page 1 of 2 Pages
Solar charge controller Shine05 User Manual
!Warning: The combination of different error
6.LED indications
INFO
CHARGE
Red
Green
conditions may cause damage to the controller.
Always remove the error before you continue connecting
the controller.
8.Technical Data
Status
Function
Slow flash(1s/1s)
float charging
Flash(0.4s/0.4s)
Batter y connected,
day detected
Fast flash(0.1s/0.1s)
Equal charging
On
Battery connected,
night detected
Off
No faults detected
On
Short circuit or Over
current protection
Slow flash(1s/1s)
Low voltage protection
Flash(0.5s/0.5s)
Over temperature
protection
Fast flash(0.1s/0.1s)
Over voltage protection
LED
Green
Red
Off
Red
Green Lighted together
(1second)
No battery connected
Controller start-up
7.Safety Features
Reverse
polarity
Protected
12V
Max solar/Load current
5A
Boost voltage
14.5V (25℃ )
Equalization voltage
14.8V (25℃)
Float voltage
13.7V (25℃)
Load disconnect voltage 11.0V
Load reconnect voltage
12.5V
Battery type
Liquid
Temperature
compensation
-4.17mV/K per cell (boost,
equalization),
-3.33mV/K per cell (float)
Max solar voltage
25V
Max batter y voltage
20V
Dimensions/Weight
90 * 49 * 18 mm / 36g
Protected *1
Own consumption
5mA
Protected *3
Switches off
immediately
Ambient temperature
-40 ~ +60 ℃
Switches off
with delay
Protected
Over voltage Max.25V *4
Max. 20V
Under
voltage
Over temp.
System voltage
Protected
Over current
Reverse
Current
Shine05
Over voltage protection 15.5V
Solar terminal Battery terminal Load terminal
Short circuit Protected*2
Model
Switches off
switches off the load if the temperature
reaches the set value.
*1.Controller can protect itself, but loads might be damaged.
*2.When the PV is not charged, the solar terminal will be
short circuited and the controller will not be damaged.
Warning: PV shall not be short circuited during charging,
otherwise the controller will be damaged.
*3.Battery must be protected by fuse, or battery will be
permanently damaged.
*4.The solar panel voltage should not exceed this limit for a
long time as voltage protection is done by a varistor.
Page 2 of 2 Pages
">