CANARM MC10 10 Amp 115V SPEED Speed Controller Installation Guide
Canarm MC10 is a wall-mount speed control for industrial ceiling fans. It allows you to adjust the fan speed, offering both updraft and downdraft configurations. Installation requires a standard electrical box and should be performed by a qualified electrician. The control features a minimum speed adjustment to prevent motor stalling.
PDF
Download
Document
Advertisement
Advertisement
WALL MOUNT SPEED CONTROL INSTALLATION INSTRUCTIONS - MC3 WARNING! Power must be turned off before wiring. Connect control in series with motor and line voltage - never connect control across line. For use with Industrial Ceiling Fans only. WIRING DOWN DRAFT UP DRAFT CONTROL CONTROL MOTOR BLACK BLUE RED WHITE GREEN BLACK 120 VOLTS SUPPLY MOTOR WHITE BLACK RED BLUE WHITE GREEN BLACK 120 VOLTS SUPPLY WHITE MOUNTING Controls are designed to fit a standard electrical box. Secure control with outer bracket tabs. MINIMUM SPEED ADJUSTMENT This control was designed to operate on Canarm Ltd. industrial fans. If you want to adjust the minimum speed, locate the minimum speed adjustment and follow these instructions. a) Motor must be in actual operating condition to achieve proper speed adjustment. (Motor will not slow down unless blades are attached). b) Turn main control knob clockwise to lowest speed position. c) Locate and adjust minimum speed setting on front plate with screwdriver (rotate clockwise to increase minimum speed, counter-clockwise to decrease minimum speed so that motor runs sufficient torque to prevent stalling. If fan stops on its own then minimum setting is too low.). d) Motor will now operate from this present minimum speed to full speed. FINAL MOUNTING a) Install front dial plate (Remove protective plastic on face of dial plate). b) Turn main control until switch clicks off. c) Push on the knob ensuring that the pointer lines up with the off position. SAFETY WARNING - PLEASE READ CAREFULLY A qualified electrician in accordance with the national electrical code and other local codes, which may apply, should install unit. This control must be grounded when installed. Failure to follow these instructions may result in electrical shock or a fire hazard. To reduce the risk of fire or electrical shock this control must not be used at ratings exceeding those clearly marked on the device. The manufacturer is not responsible for any expense, inconvenience or consequent damage caused by items of our manufacture or sale. WARRANTY For service, contact your local retail outlet or distributor. The warranty period shall be 12 months from the purchase date. Proof of payment is required for warranty validation. In all cases, the warranty shall apply only to defects in workmanship and specifically exclude any damage caused by overload, short circuit, misuse, act of vandalism, fortuitous events, acts of God, flood, fire, hail or natural disaster. This warranty becomes invalid should the installation have been made contrary to our instructions. Installation or Product problems? Do not return to store of purchase. Contact Canarm Service at 1-800-265-1833 (CANADA) 1-800-267-4427 (U.S.A.) Monday to Friday 8:00 - 5:00pm e.s.t. CANARM LTD. 2157 PARKEDALE AVENUE BROCKVILLE, ONTARIO K6V 5V6 TELEPHONE: (613) 342-5424 FAX: 1-800-263-4598 E-MAIL: [email protected] M0060 - 01/2024 CANARM LTEE. 2555 RUE BERNARD LEFEBVRE LAVAL, QUEBEC H7C 0A5 TEL: (450) 665-2535 FAX: (450) 665-0910 E-MAIL: [email protected] CANARM LTD. 808 COMMERCE PARK DRIVE OGDENSBURG, NY 13669 TELEPHONE: (800) 267-4427 FAX: 1-800-263-4598 E-MAIL: [email protected] Page 1 of 2 MODE D’INSTALLATION DU CONTROLE DE VITESSE MURAL - MC3 ATTENTION! Le courant doit étre fermé avant l’installation. Branchez le contrôle en série avec le moteur et le courant - ne branchez jamais le contrôle en travers de la ligne. Pour modèles ventilateur de plafond industriel seulement. MISE EN GARDE CIRCULATION VERS LE HAUT CIRCULATION VERS LE BAS CONTRÔLE CONTRÔLE MOTEUR NOIR BLEU ROUGE BLANC VERT NOIR 120 VOLTS A LA SOURCE BLANC MOTEUR NOIR ROUGE BLEU BLANC VERT NOIR 120 VOLTS A LA SOURCE BLANC INSTALLATION Contrôles se posent dans une boîte électrique standard. Fixez le contrôle en place à l’aide des ferrures extérieures. AJUSTEMENT DE LA VITESSE Ce régulateur éte conçu pour étre utilisé avec les ventilateurs plafonnier Canarm. Si vous désirez ajuster la vitesse minimum, localiser l'ajustement de la vitesse minimum et suivre les étapes suivantes. a) Le moteur doit étre opérationnel et complet pour permettre l'ajustement minimum approprié. (Le moteur ne ralentira pas si les pales ne sont pas installées.) b) Tournez le bouton contrôle dans le sens des aiguilles à la position de la vitesse minimum. c) A l'aide d'un tournevis, ajustez la vitesse minimum sur la plaque avant (dans les sens des aiguilles pour l'augmenter la vitesse et contre les aiguilles pour réduire. Assurez-vous de ne pas réduire la vitesse à un point tel que le moteur s'arrête, si le ventilateur s'arrêtela vitesse minimum est trop basse. d) Le moteur fonctionnera maintenant de cette vitesse minimum à la vitesse maximale établie. INSTALLATION FINALE a) Posez la plaque avant (retirez la pellicule de plastique protectice) b) Tournez le contrôle jusqu’à ce que l’interrupteur se ferme d’un bruit sec. c) Posez le bouton de façon à ce que le pointeur est à la position arrêt. MISE EN GARDE L'installation doit être faite par un électricien certifié selon les normes prescrites par les codes locaux. Ce contrôle doit être mis à terre lors de l'installation, ignorer de suivre ces instructions pourrait résulter en un risque de secousses électriques ou d'incendie. Pour éviter ceux-ci, vous devez vous assurez que la charge imposée ne dépasse pas les maximums indiqué s clairement sur le contrôle. Le manufactuier ne peut être tenu responsable des dépenses, des incovenients encourus par une défectuosité ou une mauvaise installation de ce produit. GARANTIE Communiquez avec votre dé taillant ou distributeur le plus près pour obtenir le service sur ce produit. La durée de la garantie est de 12 mois suivant la date d'achat. Une preuve d'achat est requise lors de réclamation sur la garantie. Cette garantie ne s'applique qu'aux défauts de fabrication et exclue toutes défectuositié s encourues par une surcharge, un court circuit, un abus, un acte de vandalisme, un acte de Dieu, une innondation, un incendie ou un désastre naturel. Cette garantie est nulle si l'installation n'est pas conforme aux instructions Probléms d’installation ou de produit? Ne retournez pas le produit au magasin d’achat. Contactez le service Canarm au 1-800-265-567-2513 du lundi au vendredi 8:00 - 17:00 h.d.e CANARM LTD. 2157 PARKEDALE AVENUE BROCKVILLE, ONTARIO K6V 5V6 TELEPHONE: (613) 342-5424 FAX: 1-800-263-4598 E-MAIL: [email protected] M0060 - 01/2024 CANARM LTEE. 2555 RUE BERNARD LEFEBVRE LAVAL, QUEBEC H7C 0A5 TEL: (450) 665-2535 FAX: (450) 665-0910 E-MAIL: [email protected] CANARM LTD. 808 COMMERCE PARK DRIVE OGDENSBURG, NY 13669 TELEPHONE: (800) 267-4427 FAX: 1-800-263-4598 E-MAIL: [email protected] Page 2 of 2 WALL MOUNT SPEED CONTROL INSTALLATION INSTRUCTIONS - MC5/MC10/MC15 WARNING! Power must be turned off before wiring. Connect control in series with motor and line voltage - never connect control across line. For use with Industrial Ceiling Fans only. WIRING DOWN DRAFT UP DRAFT CONTROL CONTROL MOTOR BLACK BLUE RED WHITE GREEN BLACK GREEN 120 VOLTS SUPPLY MOTOR WHITE BLACK RED BLUE WHITE GREEN BLACK GREEN 120 VOLTS SUPPLY WHITE MOUNTING Controls are designed to fit a standard electrical box. Secure control with outer bracket tabs. MINIMUM SPEED ADJUSTMENT This control was designed to operate on Canarm Ltd. industrial fans. If you want to adjust the minimum speed, locate the minimum speed adjustment and follow these instructions. a) Motor must be in actual operating condition to achieve proper speed adjustment. (Motor will not slow down unless blades are attached). b) Turn main control knob clockwise to lowest speed position. c) Locate and adjust minimum speed setting on front plate with screwdriver (rotate clockwise to decrease minimum speed, counter-clockwise to increase minimum speed so that motor runs sufficient torque to prevent stalling. If fan stops on its own then minimum setting is too low.). d) Motor will now operate from this present minimum speed to full speed. FINAL MOUNTING a) Install front dial plate (Remove protective plastic on face of dial plate). b) Turn main control until switch clicks off. c) Push on the knob ensuring that the pointer lines up with the off position. SAFETY WARNING - PLEASE READ CAREFULLY A qualified electrician in accordance with the national electrical code and other local codes, which may apply, should install unit. This control must be grounded when installed. Failure to follow these instructions may result in electrical shock or a fire hazard. To reduce the risk of fire or electrical shock this control must not be used at ratings exceeding those clearly marked on the device. The manufacturer is not responsible for any expense, inconvenience or consequent damage caused by items of our manufacture or sale. WARRANTY For service, contact your local retail outlet or distributor. The warranty period shall be 12 months from the purchase date. Proof of payment is required for warranty validation. In all cases, the warranty shall apply only to defects in workmanship and specifically exclude any damage caused by overload, short circuit, misuse, act of vandalism, fortuitous events, acts of God, flood, fire, hail or natural disaster. This warranty becomes invalid should the installation have been made contrary to our instructions. Installation or Product problems? Do not return to store of purchase. Contact Canarm Service at 1-800-265-1833 (CANADA) 1-800-267-4427 (U.S.A.) Monday to Friday 8:00 - 5:00pm e.s.t. CANARM LTD. 2157 PARKEDALE AVENUE BROCKVILLE, ONTARIO K6V 5V6 TELEPHONE: (613) 342-5424 FAX: 1-800-263-4598 E-MAIL: [email protected] M0061 - 01/2024 CANARM LTEE. 2555 RUE BERNARD LEFEBVRE LAVAL, QUEBEC H7C 0A5 TEL: (450) 665-2535 FAX: (450) 665-0910 E-MAIL: [email protected] CANARM LTD. 808 COMMERCE PARK DRIVE OGDENSBURG, NY 13669 TELEPHONE: (800) 267-4427 FAX: 1-800-263-4598 E-MAIL: [email protected] Page 1 of 2 MODE D’INSTALLATION DU CONTROLE DE VITESSE MURAL - MC5/MC10/MC15 ATTENTION! Le courant doit étre fermé avant l’installation. Branchez le contrôle en série avec le moteur et le courant - ne branchez jamais le contrôle en travers de la ligne. Pour modèles ventilateur de plafond industriel seulement. MISE EN GARDE CIRCULATION VERS LE HAUT CIRCULATION VERS LE BAS CONTRÔLE CONTRÔLE MOTEUR NOIR BLEU ROUGE BLANC VERT NOIR 120 VOLTS A LA SOURCE BLANC VERT MOTEUR NOIR ROUGE BLEU BLANC VERT VERT NOIR 120 VOLTS A LA SOURCE BLANC INSTALLATION Contrôles se posent dans une boîte électrique standard. Fixez le contrôle en place à l’aide des ferrures extérieures. AJUSTEMENT DE LA VITESSE Ce régulateur éte conçu pour étre utilisé avec les ventilateurs plafonnier Canarm. Si vous désirez ajuster la vitesse minimum, localiser l'ajustement de la vitesse minimum et suivre les étapes suivantes. a) Le moteur doit étre opérationnel et complet pour permettre l'ajustement minimum approprié. (Le moteur ne ralentira pas si les pales ne sont pas installées.) b) Tournez le bouton contrôle dans le sens des aiguilles à la position de la vitesse minimum. c) A l'aide d'un tournevis, ajustez la vitesse minimum sur la plaque avant (dans les sens des aiguilles pour réduire la vitesse et contre les aiguilles pour l'augmenter Assurez-vous de ne pas réduire la vitesse à un point tel que le moteur s'arrête, si le ventilateur s'arrêtela vitesse minimum est trop basse. d) Le moteur fonctionnera maintenant de cette vitesse minimum à la vitesse maximale établie. INSTALLATION FINALE a) Posez la plaque avant (retirez la pellicule de plastique protectice) b) Tournez le contrôle jusqu’à ce que l’interrupteur se ferme d’un bruit sec. c) Posez le bouton de façon à ce que le pointeur est à la position arrêt. MISE EN GARDE L'installation doit être faite par un électricien certifié selon les normes prescrites par les codes locaux. Ce contrôle doit être mis à terre lors de l'installation, ignorer de suivre ces instructions pourrait résulter en un risque de secousses électriques ou d'incendie. Pour éviter ceux-ci, vous devez vous assurez que la charge imposée ne dépasse pas les maximums indiqué s clairement sur le contrôle. Le manufactuier ne peut être tenu responsable des dépenses, des incovenients encourus par une défectuosité ou une mauvaise installation de ce produit. GARANTIE Communiquez avec votre dé taillant ou distributeur le plus près pour obtenir le service sur ce produit. La durée de la garantie est de 12 mois suivant la date d'achat. Une preuve d'achat est requise lors de réclamation sur la garantie. Cette garantie ne s'applique qu'aux défauts de fabrication et exclue toutes défectuositié s encourues par une surcharge, un court circuit, un abus, un acte de vandalisme, un acte de Dieu, une innondation, un incendie ou un désastre naturel. Cette garantie est nulle si l'installation n'est pas conforme aux instructions Probléms d’installation ou de produit? Ne retournez pas le produit au magasin d’achat. Contactez le service Canarm au 1-800-265-567-2513 du lundi au vendredi 8:00 - 17:00 h.d.e CANARM LTD. 2157 PARKEDALE AVENUE BROCKVILLE, ONTARIO K6V 5V6 TELEPHONE: (613) 342-5424 FAX: 1-800-263-4598 E-MAIL: [email protected] M0061 - 01/2024 CANARM LTEE. 2555 RUE BERNARD LEFEBVRE LAVAL, QUEBEC H7C 0A5 TEL: (450) 665-2535 FAX: (450) 665-0910 E-MAIL: [email protected] CANARM LTD. 808 COMMERCE PARK DRIVE OGDENSBURG, NY 13669 TELEPHONE: (800) 267-4427 FAX: 1-800-263-4598 E-MAIL: [email protected] Page 2 of 2 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Adjustable speed
- Up/Downdraft compatible
- Minimum speed setting
- Wall mount
- Industrial fan use only
Frequently asked questions
Ensure the fan blades are attached and the motor is running. Turn the main control knob to the lowest speed. Use a screwdriver to adjust the minimum speed setting on the front plate (clockwise to increase, counter-clockwise to decrease). Avoid setting it too low, which could cause the motor to stall.
The Canarm MC10 is designed for use with Canarm Ltd. industrial ceiling fans only.
Always turn off power before wiring. Connect the control in series with the motor and line voltage; never connect across the line. Wiring diagrams are provided in the viewed document for both updraft and downdraft configurations.