G83 Ever Solar Inverter Specification

G83 Ever Solar Inverter Specification
High Efficiency String Solar Inverter
1700GB 2000GB Technical Data
1700GB
2000GB
1800
450
125 - 450
125
18
13.8
1
1
MC IV-connector
10
2100
450
125 - 450
125
18
16.2
1
1
MC IV-connector
10
Spring-clamp tech
Single phase
1500
1650
According to AS4777
According to AS4777
6.5
8.25
0.99
<2%
<0.2
6
Spring-clamp tech
Single phase
1800
1980
According to AS4777
According to AS4777
7.8
9.9
0.99
<2%
<0.2
6
97.1%
96.5%
99.5%
97.1%
96.5%
99.5%
Integrated
Integrated
Integrated
According to AS4777
According to AS4777
According to AS4777
AFI(According to AS4777)
Integrated
Integrated
Integrated
According to AS4777
According to AS4777
According to AS4777
AFI(According to AS4777)
AS3100, AS4777, IEC 61000-6-3:2006
AS3100, AS4777, IEC 61000-6-3:2006
Type
DC input data
Max. PV-generator power [W]
Max. DC Voltage [V]
MPPT voltage range [V]
Turn off DC Voltage [V]
Max. DC current [A]
Nominal DC current [A]
Number of DC connection
Number of MPP trackers
DC-connection
Turn on power [W]
Output data
AC Connector
Power connection
Rated AC power [W]
Max. AC Power [W]
Grid voltage range
Grid frequency range
Rated current [A]
Max. current [A]
Power factor
Harmonic distortion (THD) at rated o
Power consumption at night [W]
Power consumption at standby [W]
Efficiency
Max. efficiency
Euro efficiency (at 360VDC)
MPPT adaptation efficiency
Safety equipment
Internal overvoltage protection
DC Insulation monitoring
Earth fault protection
Mains monitoring
Earth fault current monitoring
DC current monitoring
Islanding protection
Normative reference
SAA- compliant according to
General data
Dimensions (WxHxD) [mm]
Weight [kg]
Housing
Mounting information
Operating temperature range
Relative humidity
Site altitude
IP protection type
Isolation type
Cooling concept
Noise level
LED display
LCD display
Data logger
Data communication interfaces
Computer Communication
Standard warranty
350X370X138
14
Aluminium housing for inside and outside installation
Wall bracket
-20°C to +60°C(up 45°C derating)
0% to 98%, no condensation
Up to 2000m without derating above sea level
IP 65 according to IEC 60529
Transformerless
Convection
< 40 dBA
3
Backlight, 16 x 2 Character LCD
RS485, Optional(Wireless)
RS232
5 years
1700/2000GB
TL2100
TL3200
TL4600
TL5400
String G83 Solar Inverter 2.1KW 3.2KW 4.6KW 5.4KW
Type
TL 2100
TL 3200
TL 4600
TL 5400
DC input data
Max. PV-generator power [W]
Max. DC Voltage [V]
MPPT voltage range [V]
Turn off DC Voltage [V]
2100
580
125 - 530
125
3200
580
125 - 530
125
4600
680
125 - 550
125
5400
680
125 - 550
125
Max. DC current [A]
Nominal DC current [A]
Number of DC connection
Number of MPP trackers
DC-connection
Turn on power [W]
Output data
AC Connector
Power connection
Rated AC power [W]
Max. AC Power [W]
Grid voltage range
Grid frequency range
Rated current [A]
Max. current [A]
Power factor
Harmonic distortion (THD) at rated output
Power consumption at night [W]
Power consumption at standby [W]
Efficiency
Max. efficiency
Euro efficiency (at 360VDC)
MPPT adaptation efficiency
Safety equipment
Internal overvoltage protection
DC Insulation monitoring
Earth fault protection
Mains monitoring
Earth fault current monitoring
DC current monitoring
Islanding Effect Monitoring
DC disconnector switch
Normative reference
CE- compliant according to
General data
Dimensions (WxHxD) [mm]
Weight [kg]
Housing
Mounting information
Operating temperature range
Relative humidity
Site altitude
IP protection type
Isolation type
Cooling concept
Noise level
LED display
LCD display
Data logger
Data communication interfaces
Computer Communication
Standard warranty (option)
18
16.2
1
1
20
20
18
18
1
2
1
1
MC IV-connector
10
25
22.5
2
2
7.8
9.9
0.99
<2%
<0.2
6
Spring-clamp tech
Single phase
2800
4000
3080
4400
187-264 V
47.5-50.2 Hz
12.2
17.4
15.4
22
0.99
0.99
<2%
<2%
<0.2
<0.2
6
6
20.0
25.3
0.99
<2%
<0.2
6
97.1%
96.5%
99.5%
97.3%
96.5%
99.5%
97.5%
97.0%
99.5%
1800
1980
97.5%
97.0%
99.5%
4600
5060
Integrated
Integrated
Integrated
According to VDE 0126-1-1, GB
According to VDE 0126-1-1, GB
According to VDE 0126-1-1, GB
AFI(According to VDE 0126-1-1)
Optional DC disconnector with or without load
integraed in the device, according to VDE 0100-712
EN 50178, EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4
EN61000-3-2, EN61000-3-3
EN61000-3-12, EN61000-3-11
350 x 550 x 170
25
Aluminium housing for inside and outside installation
Wall bracket
-20°C to +60°C(up 40°C derating )
0% to 98%, no condensation
Up to 2000m without derating above sea level
IP 65 according to IEC 60529
Transformerless
Convection
Regulated cooling
< 40 dBA
3
Backlight, 16 x 2 Character LCD
RS485 (Optional Zigbee)
RS232
5 years