gtc090301
ICS - Indoor Stations
GAI-TRONICS®
Industrial Communication Systems
Features
• Fully Compatible with GAI-Tronics® Page/Party®
and ADVANCE/SmartSeries™ Systems
• Full Duplex Communication
• Efficient 30 Watt Class D Amplifier
• AC (120/230V) and DC (24V) Versions
• One or Five Party Lines
Options
•
•
•
•
•
•
•
•
One or Five Party Lines
Auxiliary Jack for Headset Operation
PVC or Hytrel® Handset Cords
Remote Volume Level Control (VLC)
SmartSeries™ Technology
Ambient Level Sensing (ALS)
Remote Monitoring
Remote Terminal Unit (RTU) Operation for
Input/Output Applications
• Stainless Steel Enclosure
ICS is GAI-Tronics’ latest generation of Page/Party® and
SmartSeries™ products, and provides two important plant
communication functions in one durable, easy-to-operate package, offering paging, and five line intercom
capability. Through the page function individuals can be
contacted anywhere in your facility. For further communication, the party line function allows two or more
people to converse without being heard over the paging
speakers.
ICS operation is simple; the user lifts the station handset,
presses the page pressbar and announces. The responding individual lifts the handset of their nearest station for
full duplex communication over the party line.
ICS is a distributed amplifier system with each station
containing a 30W speaker amplifier. Stations/amplifiers
are parallel wired, simplifying system design and expansion.
ICS stations are fully compatible with existing
GAI-Tronics® Page/Party® and ADVANCE/SmartSeries™
stations and systems, with additional features:
• External mounting flanges for ease of installation
• Increased cable termination area
• Field-upgradeable to Remote Terminal Unit
• More efficient design requires less power
• Compliance with current and upcoming UL and
worldwide approvals.
Distributed amplifier systems offer major advantages
over conventional power amplifier systems. For example,
if an amplifier fails in a distributed system, only the associated speaker is inoperable; all other system speakers will
continue to broadcast pages.
Speaker amplifier versions are available for powering
speakers where handset intercom stations are not
required. Desktop, flush-mount and desk-edge intercom
stations are also available.
ICS - Indoor Stations
GAI-TRONICS®
Industrial Communication Systems
ICS Indoor Station part numbers:
8
Indoor
Wallmount
Party
Lines
1
X
Station
Type
Control
Handset
Cord
Approval
Finish
Options
Entries
X
X
X
X
X
X
0
—


Single Party 1
Multi Party 5
Standard
Standard + VLC
Standard + VLC + RTU
Smart
Smart +RTU
Smart +Alt. Page
Smart +Emergency
Party Line (EPL)
Standard + All Call
Standard + All Call, VLC
Standard + All Call, VLC,
and RTU
Smart + RTU, EPL
Smart + All Call, RTU

AC Handset/Speaker
AC Handset/Speaker/Aux
DC Handset/Speaker
DC Handset/Speaker/Aux
1
2
5
6
Notes: Not all options may be combined contact GAI-Tronics for details.

1
2
3
4
5
6
7
A
B
C
D
E

CE
UL C Ι D2
No Options
Trop TR
70/100V
70/100V, TR
B
D
0
A
R
S

6’ PVC
15’ PVC
25’ PVC
6’ Hytrel®
15’ Hytrel®
25’ Hytrel®
1
2
3
4
5
6

Orange
Gray
316 Stainless
Steel
1
2
4
Example:
An indoor wallmount, multi-party, AC-powered handset/speaker amplifier SmartSeries™ ICS station with a 6’ PVC handset cord,
UL Class I, Division 2 approvals, orange paint with no options selected, is part number 815-141D100.
Specifications
Electrical
AC Stations
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/230VAC
Max Power Consumption . . . . . . . . . . . . . 400mA/48.0VA @ 120VAC
220mA/50.6VA @ 230VAC
Input frequency range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz
DC Stations
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC
Max Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . 1.95A/46.8W
Handset
Microphone. . . . . . . . . . . . . . . . . . . . . . . . . . Dynamic, noise-cancelling
Microphone Noise Discrimination . . . . . . . . . . . . . . . . 18dB @ 250Hz
Receiver . . . . . . . . . . . . . . . . . . . . . . Dynamic, hearing aid compatible
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABS
External Control . . . . . . . . . . . . . . . . . Push-to-page handset pressbar
Handset Amplifier
Output Level (compression controlled) . . . . . . . . . . . . . . . . . . .1.5VRMS
nominal into 33Ω load.
Frequency Response . . . . . . . . 250-6,500 Hz, +0/-3dB ref. to 1KHz
Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <1.5% THD @ 1KHz
(below compression level)
Receiver Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mVRMS nominal
®
GAI-TRONICS
USA
UK
Italy
Malaysia
Australia
Speaker Amplifier
Max Output . . . . . . . . . . . . . . 30W into 8Ω load with 1.5VRMS input
Frequency Response . . . . . . . 250–6,500 Hz, +0/-3 dB ref. to 1 kHz
Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <3% THD @ 1KHz to 30W
Input Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50KΩ
16KΩ with SmartSeries™ option
Mechanical
Construction . . . . . . . . . . . . . . . . . . . . . . 16 gauge cold-rolled steel or
316 stainless steel
Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety orange powder coating
Connections . . . . . . . . . . . . . . . . . Screw-type barrier terminal blocks
Dimensions (overall). . . . . . . . . . . . . . . . 14.5 H x 8.0 W x 8.2 D inches
(368.3 x 203.2 x 208.3 mm)
Temperature range . . . . . . . . . . … -22°F to +158°F (-30°C to +70°C)
Relative Humidity. . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensing
Environmental Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type 12
Shipping Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11lbs (5kg)
Approvals
Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 60950, UL 60950,
CAN/CSA-C22.2 No 60950
CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NRTL Listed (USA and Canada) Hazardous locations:
Class Ι, Groups A, B, C, D, Div 2
Class ΙI, Groups F & G, Div 2
Class ΙII, Div. 2
Toll Free: 1 (800) 492-1212 Tel: (610) 777-1374 Fax: (610) 796-5954 www.gai-tronics.com
Tel: +44 (0)1283 500500 Fax: +44 (0)1283 500400 www.gai-tronics.co.uk
Tel: +39 02 48601460 Fax: +39 02 93663110 www.gai-tronics.it
Tel: +60-3-8945-4035 / 8945-7348 Fax: +60-3-8945-4675 www.gai-tronics.com
Tel: 011-61-28-851-5000 Fax: 011-61-29-899-2490 www.austdac.com.au
Quality Management System Certified by DNV - ISO 9001:2008. The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice.
Pub. 090301 Rev 6/2015
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement