High Power Outdoor Solid State Power Amplifiers

High Power Outdoor Solid State Power Amplifiers
High Power Outdoor
Solid State Power Amplifiers
FEATURES
•
•
•
•
•
•
Extremely High Power
Density:
600W S-Band
500W X-Band
600W C-Band
250W Ku Band
Field Replaceable
Subassemblies
RF Output Sample Port
(-40dBc)
Ethernet Port
RF Gain Adjustment
(20 dB)
Built-in 1:1 Redundancy
Control
OPTIONS
•
DESCRIPTION
Teledyne Paradise Datacom’s High Power Outdoor (W)
series SSPAs represent the latest in High Power Microwave
Amplifier Technology. The SSPA package achieves the
highest power density in the industry along with enhanced
maintainability.
All subassemblies are accessible and replaceable in the field.
Local, front panel, control is available with a user friendly
interface. A full compliment of serial and parallel (contact
closure) control is also available via circular connectors.
A state of the art thermal platform provides efficient cooling for
the amplifier module and power supplies. This ensures the
highest possible MTBFs for microwave power amplifiers.
Along with high reliability comes the ultimate in amplifier
maintainability. Amplifier modules and power supplies are
easily accessed and removed, making this one of the easiest
amplifier assemblies to maintain in the field.
Teledyne Paradise Datacom LLC
328 Innovation Blvd., Suite 100
State College, PA 16803
Tel: (814) 238-3450
Fax: (814) 238-3829
1 OF 7
www.paradisedata.com
•
•
•
•
•
•
•
RF input sample port
(-10 dBc)
48 VDC operation
L-Band Input operation
Reflected Power Monitor
Phase Combined Systems
Fiber Optic Input
Antenna Mounting Kit
Receive Band Reject Filter
for S-Band units up to
400W in sub-band A
SPECIFICATIONS
•
•
•
•
•
Housing:
21.0 X 27.95 X 13.5 in.
533 X 710 X 343 mm
125.0 lbs. / 57 kg;
White powder coat finish
Operating temperature:
-40 to +60 °C
Relative Humidity: 100%
condensing
Integrated Forced-Air
Cooling
Teledyne Paradise Datacom Ltd.
2&3 The Matchyns, London Road, Rivenhall End
Witham, Essex CM8 3HA United Kingdom
Tel: +44(0) 1376 515636
Fax: +44(0) 1376 533764
202589 REV X ECO 16694
High Power Outdoor
Solid State Power Amplifiers
S-Band Output Power Levels
PARAMETER
Frequency Range
Output Power @ Saturation / P1dB
Typical / Guaranteed Minimum
Prime Input Power
Line Voltage
Line Frequency
Line Power
NOTES
LIMITS
UNITS
Band A
Band B
2.020 to 2.120
2.200 to 2.300
GHz
GHz
Band A
HPAS2400AWXXXXX (2.020 - 2.090 GHz)
HPAS2400AWXXXXX (2.095 - 2.120 GHz)
HPAS2500AWXXXXX (2.020 - 2.090 GHz)
HPAS2500AWXXXXX (2.095 - 2.120 GHz)
HPAS2600AWXXXXX (2.020 - 2.090 GHz)
HPAS2600AWXXXXX (2.095 - 2.120 GHz)
Band B
HPAS2400BWXXXXX (2.200 - 2.300 GHz)
HPAS2500BWXXXXX (2.200 - 2.300 GHz)
HPAS2600BWXXXXX (2.200 - 2.300 GHz)
Psat/P1dB
56.5 / 56.0 (447/400)
56.0 / 55.5 (400/355)
57.2 / 57.0 (525/500)
56.7 / 56.5 (468/447)
58.0 / 57.5 (631/560)
57.5 / 57.0 (560/500)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
56.5 / 56.0 (447/400)
57.2 / 57.0 (525/500)
58.0 / 57.5 (631/560)
dBm (W)
dBm (W)
dBm (W)
47– 63
1800
3500
3800
Hz
W
W
W
NOTES
LIMITS
UNITS
(see options for extended band)
5.850 to 6.425
Power factor corrected
HPAS2400A/BWXXXXX (180 - 265 VAC)
HPAS2500AWXXXXX (180 - 265 VAC)
HPAS2600AWXXXXX (180 - 265 VAC)
C-Band Output Power Levels
PARAMETER
Frequency Range
Output Power @: Saturation/P1dB
(Typical/Guaranteed minimum)
Power Requirements
Line Voltage
Line Frequency
Line Power
GHz
Psat / P1dB
56.0/55.0 (400/316)
57.0/56.0 (500/400)
57.8/57.0 (600/500)
HPAC2400AW
HPAC2500AW
HPAC2600AW
Power Factor corrected
Autoranging
HPAC2400AW (180 to 265 VAC)
HPAC2500AW (180 to 265 VAC)
HPAC2600AW (180 to 265 VAC)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
> 0.9
47 - 63
2400
2800
3700
Hz
W
W
W
NOTES
LIMITS
UNITS
(see options for extended band)
7.90 to 8.40
GHz
HPAX2350AW
HPAX2500AW
Psat / P1dB
55.5/54.5 (354/282)
57.0/55.7 (500/370)
dBm (W)
dBm (W)
Power Factor corrected
Autoranging
HPAX2350AW (180 to 265 VAC)
HPAX2500AW (180 to 265 VAC)
> 0.94
47 - 63
2700
4000
Hz
W
W
X-Band Output Power Levels
PARAMETER
Frequency Range
Output Power @: Saturation/P1dB
(Typical/Guaranteed minimum)
Power Requirements
Line Voltage
Line Frequency
Line Power
2 OF 7
202589 REV X ECO 16694
High Power Outdoor
Solid State Power Amplifiers
Ku-Band Output Power Levels
PARAMETER
Frequency Range
Output Power
Saturation/P1dB
(Typical/Guaranteed minimum)
Power Requirements
Line Voltage
Line Frequency
Line Power
NOTES
LIMITS
UNITS
(see options for extended band)
14.00 to 14.50
GHz
HPAK2200AW
HPAK2250AW
Psat / P1dB
53.0/52.0 (200/158)
54.0/53.0 (250/200)
dBm (W)
dBm (W)
Power Factor corrected
Autoranging
HPAK2200AW (180 to 265 VAC)
HPAK2250AW (180 to 265 VAC)
> 0.94
47 - 63
2500
2800
Hz
W
W
Common Specifications; HPA_2000XW Series
Electrical Specifications
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Variation vs. Temperature
Gain Adjustment
Intermodulation Distortion
AM/PM Conversion
Spurious
Harmonics
Input/Output VSWR
Noise Figure
NOTES
LIMITS
UNITS
range
full band
Extended C-Band units
per 40 MHz (C-,X-,Ku-bands)
per 10 MHz (S-band)
-40°C to +60°C
0.1 dB resolution
55-75
±1.0
±1.5
±0.3
±0.2
±1.5
20
dB
dB
dB
dB/40 MHz
dB/10 MHz
dB
dB
3dB back off relative to P1dB
-25
dBc
(@ rated P1dB)
(@P1dB-3dB)
3.5
1.0
o
(@ rated P1dB)
(@ rated P1dB-3dB) (C-,X-,Ku-bands)
(@ rated P1dB-3dB) (S-band)
-60
-50
-30
dBc
dBc
dBc
Standard Band units
Extended Band units
1.30:1
1.50:1
/dB
/dB
o
at maximum gain
10
dB
Linear
Parabolic
Ripple
0.01
0.003
1.0
ns/MHz
ns/MHz2
ns p-p
TX Band (S-,C-, X- or Ku-Band)
RX Band (C- or Ku-Band)
RX Band (X-Band)
RX Band (S-Band)
-75
-150
-100
See options
dBW/4 KHz
dBW/4 KHz
dBW/4 KHz
0 - 10 KHz
10 KHz - 500 KHz
500 KHz - 1 MHz
-45
-20 (1.25 + log F)
-80
dBc
dBc
dBc
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
-90
-100
-110
-120
-125
-130
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
21.0 X 27.95 X 13.5
533 X 710 X 343
inches
mm
Weight
125 (57)
lbs.(kg)
Finish
powder coat
white
Group Delay
(per 40 MHz segment)
Noise Output
Residual AM Noise
Phase Noise
Mechanical Specifications
Size
width X height X depth
Specifications are subject to change.
3 OF 7
202589 REV X ECO 16694
High Power Outdoor
Solid State Power Amplifiers
Options
Extended C-Band
Model:
5.850 to 6.725 GHz
De-rate power by 1.0dB linearly from 6.425 to 6.725 GHz
HPAC2XXXBWXXXXX
5.750 to 6.670 GHz
De-rate power by 1.0dB linearly from 6.425 to 6.725 GHz
HPAC2XXXCWXXXXX
6.425 to 7.025 GHz
Available in power levels up to 500W
HPAC2XXXE/FWXXXXX
Extended X-Band
Model:
7.70 to 8.40 GHz
De-rate power by 1.0dB linearly from 7.90 to 7.70 GHz
HPAX2XXXDWXXXXX
Extended Ku-Band
Model:
13.75 to 14.5 GHz
De-rate power by 1.0dB linearly from 14.0 to 13.75 GHz
HPAK2XXXBWXXXXX
Reflected Power Monitor
See the part number configuration to determine Model numbers for this option.
Receive Band Reject Filter (S-Band only)
Insertion Loss
- 0.5
dB
Filter integrated into 400W SSPA chassis
Rx Reject
-60
dB
500W and 600W SSPAs require external filter.
Receive Band Noise Power Density
Without optional filter
-95
dBw/4 KHz
With optional filter
-155
dBw/4 KHz
AC IN
J7
PARALLEL I/O
J5
ETHERNET
J9
LINK PORT
J4
SWITCH PORT
J6
SERIAL MAIN
J3
+15 VDC OUT
J8
RF OUTPUT
SAMPLE
RF INPUT
SAMPLE
RF IN
J1
RF OUTPUT
J2
MOD EL: XXXXXXXXXXXX
S/N: XXXX
P/N: L202701-X
Ku-Band
Sol id State Power Amplifier System
4 OF 7
202589 REV X ECO 16694
High Power Outdoor
Solid State Power Amplifiers
L-Band Operation
Teledyne Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band
Block Up Converter. The L-Band units utilize Paradise Datacom’s proprietary ZBUCTM
technology. The addition of a ZBUC converter to a High Power Outdoor SSPA typically
increases the gain by 2-4 dB. The advantages of ZBUCTM technology include:
• A ZBUC converter can detect and switch to an extenally supplied reference.
• Optional internal high stability (10MHz) reference.
• A ZBUC converter can lock to an externally supplied reference of 5, 10, 20, 25, or 50 MHz
without modification.
• A ZBUC converter can accept a wide range of external reference power (-10 to +5 dBm)
• A ZBUC converter can accept FSK monitor and control signal via the IFL for complete
amplifer remote control.
Available Frequency Plans
Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
C
Palapa Band
950 - 1250 MHz
5.475 GHz
6.425 - 6.725 GHz
0-4 dB
C
Insat Band
950 - 1250 MHz
5.775 GHz
6.725 - 7.025 GHz
0-4 dB
C
Extended C-Band 2
950 - 1675 MHz
4.800 GHz
5.750 - 6.475 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Electrical Specifications for High Power Outdoor with ZBUC converter
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Adjusted Range
Gain Stability
Phase Noise
Spurious
NOTES
LIMITS
UNITS
Nominal setting
full band (C-,X-,Ku-bands)
per 40 MHz (C-,X-,Ku-bands)
75
±2.0
±0.5
20
60 - 80
57 - 77
±1.5
dB
dB
dB/40 MHz
dB
dB
dB
dB
Typical C-Band Adj. Range
Typical Ku-Band Adj. Range
-40 to +60 °C
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Absolute max.
-30
-60
-70
-80
-90
-90
C-band (typ.)
-60
-80
-80
-85
-120
-125
In-Band Signal Related (C-/Ku-Band)
(Extended C-Band)
Close to Carrier Spurious (< 20 MHz)
Local Oscillator
X-band (typ.)
-60
-75
-75
-100
-110
-122
Ku-band (typ.)
-50
-65
-72
-90
-110
-120
-50
-40
-50
-30
dBc
dBc
dBc
dBm
dB
Noise Figure
At 75 dB gain setting
20
Input VSWR
L-Band
1.5 : 1
Reference accuracy @ 25 °C
Reference Stability over Temperature (-40 to +40 °C)
±1 • 10-8
±1 • 10-9
Internal Reference Option
5 OF 7
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
202589 REV X ECO 16694
High Power Outdoor
Solid State Power Amplifiers
Interface Specifications; HPA_2000XW Series
PARAMETER
NOTES
LIMITS
UNITS
Monitor & Control (J5)
Parallel Port Outputs
Form C Relays
Contact conditions on fault
(Closed, Open, Common)
Power Supply Fault
Auxiliary Fault
Mute Status
Block Up Converter Fault
Temperature Fault
Current Fault
Low RF Alarm
Mute Input
Local Remote
Auxiliary Fault Input
Standby Select
Latched Fault Reset
Auto/Manual Switching
+5V pull-up
Ground
RS232 Out, RS485 TXRS232 In, RS485 RXRS485 RX+
RS485 TX+
Service Request 1
Service Request 2
Service Request Common
Termination
Ground
RS485+
RS485Link Out
Link In
Ground
+28 VDC
RF Switch 1, pos 1
RF Switch 1, pos 2
RF Switch 2, pos 1
RF Switch 2, pos 2
Type N
Pins A, B, C
Pins D, E, F
Pins G, H, J
Pins K, L, M
Pins N, P, R
Pins V, W, X
Pins a, Y, Z
Pin b
Pin c
Pin d
Pin e
Pin f
Pin g
Pins h, I, j, k, m
Pin n
Pin A
Pin B
Pin C
Pin D
Pin E
Pin F
Pin G
Pin H
Pin J
A, B
C, D
E, F
G, H
Pin J
A, B
C
E
D
F
Female
Type N
WR137 Waveguide
WR112 Waveguide
WR75 Waveguide
Line
Neutral
Ground
+48 VDC
Return
External Fault In
Reserved
+15VDC LNA
Ground
+15VDC External
Ground
TX+
TXRX+
RXGround
Female
CPR137G flange (PDR-70)
CPR112G flange (PDR-84)
Grooved flange (PBR-120)
A
C
B
A,B
C,D
A
B
C
D
E
F
1
2
3
6
4,5,7,8
Connector: MS3112E20-41S
Mate: MS3116F20-41P
Mute Status
RF Switch Position
Parallel Port Inputs
Main Serial Port (J3)
RS232 / RS485
Summary Alarm
Connector: MS3112E12-10P
Mate: MS3116F12-10S
Link Port (J4)
1:1 Redundant System Control Link
Connector: MS3112E12-10S
Mate: MS3116F12-10P
Switch Port (J6)
Redundant Switch Control
Connector: MS3112E10-6S
Mate: MS3116F10-6P
RF Connectors
AC Input (J7)
Connector: MS3102E20-3P
Mate: MS3106E20-3S
Optional 48 VDC Input
MS3102E20A37P
+15 VDC Output (J8)
RF Input (J1), Input & Output Sample
RF Output (J2)
HPAS2XXXXW
HPAC2XXXXW
HPAX2XXXXW
HPAK2XXXXW
Line Power
DC Input Power
Auxiliary Power
Connector: MS3112E10-6S
Mate: MS3116F10-6P
Ethernet Port (J9)
Remote M&C, UDP, SNMP
Connector: RJ45 (F)
Environmental Specifications
Operating Temperature
Relative Humidity
Cooling System
6 OF 7
Ambient
-40 to +60
°C
Condensing
100
%
Integrated
Forced air
202589 REV X ECO 16694
High Power Outdoor
Solid State Power Amplifiers
Part Number Configuration
HPA
2
Band
S - S-Band
C - C-Band
X - X-Band
K - Ku-Band
Power Level (in Watts)
S-Band
400, 500 or 600
C-Band
400, 500 or 600
X-Band
350 or 500
Ku-Band
200 or 250
Frequency Sub Band
S-Band
A - 2.020 - 2.120 GHz
B - 2.200 - 2.300 GHz
C-Band
A1 - 5.85 - 6.425 GHz
B1 - 5.85 - 6.725 GHz
C - 5.75 - 6.670 GHz
E1,2 - 6.425 - 6.725 GHz (Palapa)
F1,2 - 6.725 - 7.025 GHz (Insat)
G1 - 5.750 - 6.475 GHz
H1 - 5.715 - 5.790 GHz
J1 - 5.740 - 6.650 GHz
V1,3 - 5.85 - 6.725 GHz
X-Band
1
A - 7.90 - 8.40 GHz
B - 7.50 - 8.50 GHz
D - 7.70 - 8.40 GHz
E - 7.75 - 8.50 GHz
Ku-Band
1
A - 14.00 - 14.50 GHz
B1 - 13.75 - 14.50 GHz
1
Available with optional BUC.
Available in 400W or 500W power levels.
3
With 1.3:1 VSWR.
2
7 OF 7
W
Configuration Modifier
XXX = Standard
SXX = Input Sample
XVX = Reflected Power
Monitor
XXR* = Receive Band Reject
Filter
* S-Band only
System Configuration
X = Standalone
See the following specification sheets for the
appropriate configuration:
• Outdoor Packaged Redundant SSPA
Systems (203581)
• Outdoor Packaged Phase Combined SSPA
Systems (203582)
Block Up Converter
B = BUC (Custom)
M = Internal Reference ZBUC (FSK)
P = External Reference ZBUC (FSK)
X = None
An
An optional
optional uni-strut
uni-strut
mounting
mounting kit
kit is
is available.
available.
Example - A standalone 500W Extended C-Band High
Power Outdoor SSPA with block up converter using an
external reference is part number:
HPAC2500BWPXXXX.
Specifications listed in this document are subject to change without notice.
X-Band products may be subject to ITAR restrictions and should not be exported
from the U.S. without obtaining proper licensing from the appropriate government
agencies.
202589 REV X ECO 16694
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement