- Home
- Do-It-Yourself tools
- Power tools
- Paint Sprayer
- Graco
- 312065K - Reactor, Electric Proportioners
- Owner's manual
- 42 Pages
Graco 312065K - Reactor, Electric Proportioners Owner's Manual
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
42
Operation 312065K ENG Electric, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. For professional use only. Not for use in explosive atmospheres. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 4 for model information, including maximum working pressure and approvals. Model E-XP1 Shown Russian Patent No. 2359181 Taiwan Patent No. 1 303996 Australian Patent No. 2003291660 Other patents pending TI10953a Contents Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Supplied Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Important Two-Component Material Information 10 Isocyanate Conditions . . . . . . . . . . . . . . . . . . . . 10 Material Self-ignition . . . . . . . . . . . . . . . . . . . . . 10 Keep Components A and B Separate . . . . . . . . 10 Moisture Sensitivity of Isocyanates . . . . . . . . . . 10 Foam Resins with 245 fa Blowing Agents . . . . . 11 Changing Materials . . . . . . . . . . . . . . . . . . . . . . 11 Typical Installation, with circulation . . . . . . . . . . 12 Typical Installation, without circulation . . . . . . . 13 Component Identification . . . . . . . . . . . . . . . . . . . 14 Temperature Controls and Indicators . . . . . . . . . 15 Main Power Switch . . . . . . . . . . . . . . . . . . . . . . 15 Red Stop Button . . . . . . . . . . . . . . . . . . . . . . . . 15 Actual Temperature Key/LED . . . . . . . . . . . . . . 15 Target Temperature Key/LED . . . . . . . . . . . . . . 16 Temperature Scale Keys/LEDs . . . . . . . . . . . . . 16 Heater Zone On/Off Keys/LEDs . . . . . . . . . . . . 16 Temperature Arrow Keys . . . . . . . . . . . . . . . . . . 16 Temperature Displays . . . . . . . . . . . . . . . . . . . . 16 Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . 16 2 Motor Controls and Indicators . . . . . . . . . . . . . . . 17 Motor ON/OFF Key/LED . . . . . . . . . . . . . . . . . . 17 PARK Key/LED . . . . . . . . . . . . . . . . . . . . . . . . . 17 PSI/BAR Keys/LEDs . . . . . . . . . . . . . . . . . . . . . 17 Pressure Key/LED . . . . . . . . . . . . . . . . . . . . . . . 17 Cycle Count Key/LED . . . . . . . . . . . . . . . . . . . . 17 Pressure Arrow Keys . . . . . . . . . . . . . . . . . . . . . 18 Pressure/Cycle Display . . . . . . . . . . . . . . . . . . . 18 Spray Adjustments . . . . . . . . . . . . . . . . . . . . . . . . 18 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Spraying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Pressure Relief Procedure . . . . . . . . . . . . . . . . . . 32 Fluid Circulation . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Circulation Through Reactor . . . . . . . . . . . . . . . 33 Circulation Through Gun Manifold . . . . . . . . . . . 34 Jog Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Diagnostic Codes . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Temperature Control Diagnostic Codes . . . . . . . 36 Motor Control Diagnostic Codes . . . . . . . . . . . . 36 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Fluid Inlet Strainer Screen . . . . . . . . . . . . . . . . . 37 Pump Lubrication System . . . . . . . . . . . . . . . . . 38 Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 42 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 42 312065K Systems Systems Part Maximum Fluid Working Pressure psi (MPa, bar) Heated Hose Gun Proportioner (see page 4) 50 ft (15 m) 10 ft (3 m) Model Part Mix Chamber Kit AP9024 2500 (17.2, 172) 259024 246679 246055 Fusion™ Air Purge 246100 AR2020 AP9025 2000 (13.8, 138) 259025 246678 246050 Fusion™ Air Purge 246101 AR5252 AP9026 2000 (13.8, 138) 259026 246678 246050 Fusion™ Air Purge 246101 AR5252 AP9028 3500 (24.1, 241) 259028 246679 246055 Fusion™ Air Purge 246100 AR2020 AP9029 2500 (17.2, 172) 259029 246679 246055 Fusion Air Purge 246100 AR2020 AP9030 2000 (13.8, 138) 259030 246678 246050 Fusion™ Air Purge 246101 AR5252 AP9031 2000 (13.8, 138) 259031 246678 246050 Fusion™ Air Purge 246101 AR5252 AP9032 3500 (24.1, 241) 259032 246679 246055 Fusion™ Air Purge 246100 AR2020 AP9033 2500 (17.2, 172) 259033 246679 246055 Fusion™ Air Purge 246100 AR2020 AP9034 2000 (13.8, 138) 259034 246678 246050 Fusion™ Air Purge 246101 AR5252 AP9035 2000 (13.8, 138) 259035 246678 AP9036 3500 (24.1, 241) 259036 AP9057 2000 (13.8, 138) 259057 AP9058 2000 (13.8, 138) AP9059 ™ 246050 ™ Fusion Air Purge 246101 AR5252 246679 246055 Fusion™ Air Purge 246100 AR2020 246678 246050 Fusion™ Air Purge 246101 AR5252 259058 246678 246050 Fusion™ Air Purge 246101 AR5252 2000 (13.8, 138) 259059 246678 246050 Fusion™ Air Purge 246101 AR5252 CS9025 2000 (13.8, 138) 259025 246678 246050 Fusion™ CS CS01RD CS9026 2000 (13.8, 138) 259026 246678 246050 Fusion™ CS CS02RD CS9030 2000 (13.8, 138) 259030 246678 246050 CS9031 2000 (13.8, 138) 259031 246678 246050 CS9034 2000 (13.8, 138) 259034 246678 246050 Fusion CS9035 2000 (13.8, 138) 259035 246678 CS9057 2000 (13.8, 138) 259057 CS9058 2000 (13.8, 138) CS9059 P29024 P29025 P29026 P29028 P29029 P29030 P29031 P29032 P29033 P29034 P29035 P29036 P29057 P29058 P29059 312065K ™ CS CS01RD ™ CS CS02RD ™ CS CS01RD 246050 Fusion™ CS CS02RD 246678 246050 Fusion™ CS CS02RD 259058 246678 246050 Fusion™ CS CS02RD 2000 (13.8, 138) 259059 246678 246050 2500 (17.2, 172) 2000 (13.8, 138) 2000 (13.8, 138) 3500 (24.1, 241) 2500 (17.2, 172) 2000 (13.8, 138) 2000 (13.8, 138) 3500 (24.1, 241) 2500 (17.2, 172) 2000 (13.8, 138) 2000 (13.8, 138) 3500 (24.1, 241) 2000 (13.8, 138) 2000 (13.8, 138) 2000 (13.8, 138) 259024 259025 259026 259028 259029 259030 259031 259032 259033 259034 259035 259036 259057 259058 259059 246679 246678 246678 246679 246679 246678 246678 246679 246679 246678 246678 246679 246678 246678 246678 246055 246050 246050 246055 246055 246050 246050 246055 246055 246050 246050 246055 246050 246050 246050 Fusion Fusion ™ Fusion CS Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 Probler P2 CS02RD GCP2RA GCP2R1 GCP2R2 GCP2R0 GCP2RA GCP2R1 GCP2R2 GCP2R0 GCP2RA GCP2R1 GCP2R2 GCP2R0 GCP2R2 GCP2R2 GCP2R2 3 Models Models E-20 SERIES Part, Series Full Load Peak Voltage Amps* (phase) 259025, D 259030, D 259034, D 48 24 32 230V (1) 400V (3) 230V (3) System Watts† Primary Heater Watts Max Flow Rate◆ lb/min (kg/min) Approximate Output per Cycle Maximum Fluid (A+B) Working Pressure gal. (liter) psi (MPa, bar) 10,200 10,200 10,200 6,000 6,000 6,000 20 (9) 20 (9) 20 (9) 0.0104 (0.0395) 0.0104 (0.0395) 0.0104 (0.0395) System Watts† Primary Heater Watts Max Flow Rate◆ lb/min (kg/min) Approximate Output per Cycle Maximum Fluid (A+B) Working Pressure gal. (liter) psi (MPa, bar) 17,900 17,900 17,900 23,000 23,000 23,000 10,200 10,200 10,200 15,300 15,300 15,300 30 (13.5) 30 (13.5) 30 (13.5) 30 (13.5) 30 (13.5) 30 (13.5) 0.0272 (0.1034) 0.0272 (0.1034) 0.0272 (0.1034) 0.0272 (0.1034) 0.0272 (0.1034) 0.0272 (0.1034) System Watts† Primary Heater Watts Max Flow Rate◆ gpm (lpm) Approximate Output per Cycle Maximum Fluid (A+B) Working Pressure gal. (liter) psi (MPa, bar) 15,800 15,800 15,800 10,200 10,200 10,200 1.0 (3.8) 1.0 (3.8) 1.0 (3.8) 0.0104 (0.0395) 0.0104 (0.0395) 0.0104 (0.0395) System Watts† Primary Heater Watts Max Flow Rate◆ gpm (lpm) Approximate Output per Cycle Maximum Fluid (A+B) Working Pressure gal. (liter) psi (MPa, bar) 23,000 23,000 23,000 15,300 15,300 15,300 2.0 (7.6) 2.0 (7.6) 2.0 (7.6) 0.0203 (0.0771) 0.0203 (0.0771) 0.0203 (0.0771) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) E-30 SERIES Part, Series Full Load Peak Voltage Amps* (phase) 259026, D 259031, D 259035, D 259057, D 259058, D 259059, D 78 34 50 100 62 35 230V (1) 400V (3) 230V (3) 230V (1) 230V (3) 400V (3) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) E-XP1 SERIES Part, Series Full Load Peak Voltage Amps* (phase) 259024, D 259029, D 259033, D 69 24 43 230V (1) 400V (3) 230V (3) 2500 (17.2, 172) 2500 (17.2, 172) 2500 (17.2, 172) E-XP2 SERIES Part, Series 259028, D 259032, D 259036, D Full Load Peak Voltage Amps* (phase) 100 35 62 230V (1) 400V (3) 230V (3) 3500 (24.1, 241) 3500 (24.1, 241) 3500 (24.1, 241) * Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less. ◆ Maximum flow rate given for 60 Hz operation. For 50 † Total system watts, based on maximum hose length Approvals: Hz operation, maximum flow rate is 5/6 of 60 Hz maximum flow. for each unit: • • 4 E-20 and E-XP1 series, 210 ft (64 m) maximum heated hose length, including whip hose. E-30 and E-XP2 series, 310 ft (94.5 m) maximum heated hose length, including whip hose. #ONFORMSTO!.3)5, 3TD#ERTIFIEDTO #!.#3!3TD #.O 312065K Supplied Manuals Supplied Manuals Related Manuals The following manuals are shipped with the Reactor™ Proportioner. Refer to these manuals for detailed equipment information. The following manuals are for accessories used with the Reactor™. Order Part 15M334 for a compact disk of Reactor manuals translated in several languages. Manuals are also available at www.graco.com. Order Part 15M334 for a compact disk of Reactor manuals translated in several languages. Reactor Data Reporting Kit Part Description Reactor Electric Proportioner 309867 Instruction-Parts Manual (English) Part Description Fusion Spray Gun 312066 Reactor Electric Proportioner, Repair-Parts Manual (English) Part Description 309550 Instruction-Parts Manual (English) Reactor Electrical Diagrams Fusion CS Spray Gun Part Description Part Description 312067 Reactor Electric Proportioner, Electrical Diagrams (English) 312666 Instruction-Parts Manual (English) Proportioning Pump Part Description 309577 Electric Reactor Displacement Pump Repair-Parts Manual (English) Probler P2 Spray Gun Part Description 313213 Instruction-Parts Manual (English) Heated Hose Part Description 309572 Instruction-Parts Manual (English) Circulation and Return Tube Kit Part Description 309852 Instruction-Parts Manual (English) Rupture Disk Assembly Kit Part Description 312416 Instruction-Parts Manual (English) Electric Reactor Installation 312065K Part Description 310815 Instruction Manual (English) 5 Related Manuals 6 312065K Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment. • Connect only to grounded power source. • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • • • Read MSDSs to know the specific hazards of the fluids you are using. Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Engage trigger lock when not spraying. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses and couplings daily. Replace worn or damaged parts immediately. 312065K 7 Warnings WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • • • • • • • • • Use equipment only in well ventilated area. Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). Keep work area free of debris, including solvent, rags and gasoline. Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. Ground all equipment in the work area. See Grounding instructions. Use only grounded hoses. Hold gun firmly to side of grounded pail when triggering into pail. If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. Keep a working fire extinguisher in the work area. THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury. • • Open a valve to relieve the fluid expansion during heating. Replace hoses proactively at regular intervals based on your operating conditions. PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage. • • 8 Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents. Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility. 312065K Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • This equipment is for professional use only. • Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure in this manual when equipment is not in use. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely. 312065K 9 Important Two-Component Material Information Important Two-Component Material Information Isocyanate Conditions Keep Components A and B Separate Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates. Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (isocyanate) and component B (resin) parts. Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates. Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area. To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area. Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts. Material Self-ignition The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature. To prevent exposing ISO to moisture: Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS. • • • • • • 10 Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container. Keep the ISO lube pump reservoir (if installed) filled with Graco Throat Seal Liquid (TSL), Part 206995. The lubricant creates a barrier between the ISO and the atmosphere. Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system. Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use. Never use solvent on one side if it has been contaminated from the other side. Always lubricate threaded parts with ISO pump oil or grease when reassembling. 312065K Important Two-Component Material Information Foam Resins with 245 fa Blowing Agents Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system. 312065K Changing Materials • When changing materials, flush the equipment multiple times to ensure it is thoroughly clean. • Always clean the fluid inlet strainers after flushing. • Check with your material manufacturer for chemical compatibility. • Most materials use ISO on the A side, but some use ISO on the B side. • Epoxies often have amines on the B (hardener) side. Polyureas often have amines on the B (resin) side. 11 Typical Installation, with circulation Typical Installation, with circulation Key for FIG. 1 A B C D E F Reactor Proportioner Heated Hose Fluid Temperature Sensor (FTS) Heated Whip Hose Fusion Spray Gun Gun Air Supply Hose G J K L M P R Feed Pump Air Supply Lines Fluid Supply Lines Feed Pumps Agitator Desiccant Dryer Gun Fluid Manifold (part of gun) Circulation Lines M K K R L J G A F J D B E R P C* TI10976a * Shown exposed for clarity. Wrap with tape during operation, FIG. 1: Typical Installation, with circulation 12 312065K Typical Installation, without circulation Typical Installation, without circulation Key for FIG. 2 A B C D E F G Reactor Proportioner Heated Hose Fluid Temperature Sensor (FTS) Heated Whip Hose Fusion Spray Gun Gun Air Supply Hose Feed Pump Air Supply Lines H J K L M N P Q K Waste Containers Fluid Supply Lines Feed Pumps Agitator Desiccant Dryer Bleed Lines Gun Fluid Manifold (part of gun) Air Filter/Separator M K J L G A J N G D F E P B C* H TI10975a * Shown exposed for clarity. Wrap with tape during operation, FIG. 2: Typical Installation, without circulation 312065K 13 Component Identification Component Identification Key for FIG. 3 BA BB FA FB GA GB HA HB PA PB SA SB TA TB Component A Pressure Relief Outlet Component B Pressure Relief Outlet Component A Fluid Manifold Inlet (behind manifold block) Component B Fluid Manifold Inlet Component A Pressure Gauge Component B Pressure Gauge Component A Hose Connection Component B Hose Connection Component A Pump Component B Pump Component A PRESSURE RELIEF/SPRAY Valve Component B PRESSURE RELIEF/SPRAY Valve Component A Pressure Transducer (behind gauge GA) Component B Pressure Transducer (behind gauge GB) DG EC EM FH FM FV HC MC MP RS SC SN TC Drive Gear Housing Electrical Cord Strain Relief Electric Motor Fluid Heaters (behind shroud) Reactor Fluid Manifold Fluid Inlet Valve (B side shown) Heated Hose Electrical Connector Motor Control Display Main Power Switch Red Stop Button Fluid Temperature Sensor Cable Serial No. Plate Temperature Control Display TC MC RS EM DG FH GA DG TA PA GB TB SA FM FA SB BA PB HC SC FV MP FB EC BB HA HB TI9880a SN TI10953a TI7823a FIG. 3: Component Identification (Model EXP-1 Shown) 14 312065K Temperature Controls and Indicators Temperature Controls and Indicators NOTICE To prevent damage to the softkey buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails. Heater Power Indicators Zone A Arrow Keys A Zone B Arrow Keys B Heater Displays Heater A On/Off Key Heater B On/Off Key Hose Zone Arrow Keys Hose Heater On/Off Key °F Actual Temperature Key °C Temperature Scale Keys Target Temperature Key FIG. 4. Temperature Controls and Indicators Main Power Switch Red Stop Button Located on right side of unit, page 14. Turns Reactor Located between temperature control panel and motor power ON control panel, page 14. Press and OFF heater zones or pumps on. 312065K . Does not turn to shut off motor and heater zones only. Use main power switch to shut off all power to unit. 15 Temperature Controls and Indicators Actual Temperature Key/LED Press to display actual temperature. Press and hold Temperature Displays Show actual temperature or target temperature of heater zones, depending on selected mode. Defaults to actual at startup. Range is 32-190°F (0-88°C) for A and B, 32-180°F (0-82°C) for hose. to display electrical current. Circuit Breakers Target Temperature Key/LED Press to display target temperature. Press and hold to display heater control circuit board temperature. Temperature Scale Keys/LEDs Press °F or °C to change temperature scale. Heater Zone On/Off Keys/LEDs Press Located inside Reactor cabinet. Ref. Size Component CB1 50 A Hose/Transformer Secondary CB2 40 A Transformer Primary CB3 25, 40* Heater A CB4 25, 40* Heater B CB5 20 Motor/Pumps * Depending on model. to turn heater zones on and off. Also clears heater zone diagnostic codes, see page 36. LEDs flash when heater zones are on. The duration of each flash shows the extent that the heater is turned on. CB1 Temperature Arrow Keys Press , then press or perature settings in 1 degree increments. 16 to adjust tem- CB2 CB3 CB4 ti9884a CB5 For wiring and cabling, see repair manual 312066. 312065K Motor Controls and Indicators Motor Controls and Indicators NOTICE To prevent damage to the softkey buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails. Pressure/Cycle Display Arrow Keys Motor ON/OFF Key ON / OFF PARK Key Pressure Key PARK PSI/BAR Keys Cycle Count Key PSI BAR FIG. 5. Motor Controls and Indicators Motor ON/OFF Key/LED Pressure Key/LED Press Press to turn motor ON and OFF. Also clears to display fluid pressure. some motor control diagnostic codes, see page 36. PARK Key/LED Press at end of day to cycle component A pump to home position, submerging displacement rod. Trigger gun until pump stops. Once parked, motor will automatically shut off. PSI/BAR Keys/LEDs Press 312065K PSI or BAR If pressures are imbalanced, display shows higher of two pressures. Cycle Count Key/LED Press to display cycle count. To clear counter, press and hold for 3 sec. to change pressure scale. 17 Spray Adjustments Pressure Arrow Keys Spray Adjustments Press Flow rate, atomization, and amount of overspray are affected by four variables. or to adjust fluid pressure when motor is ON. Setpoint displays for 10 sec. When motor is OFF, pressing To exit jog mode, press • Fluid pressure setting. Too little pressure results in an uneven pattern, coarse droplet size, low flow, and poor mixing. Too much pressure results in excessive overspray, high flow rates, difficult control, and excessive wear. • Fluid temperature. Similar effects to fluid pressure setting. The A and B temperatures can be offset to help balance the fluid pressure. • Mix chamber size. Choice of mix chamber is based on desired flow rate and fluid viscosity. • Clean-off air adjustment. Too little clean-off air results in droplets building up on the front of the nozzle, and no pattern containment to control overspray. Too much clean-off air results in air-assisted atomization and excessive overspray. will enter jog mode. until display shows dashes or current pressure. Pressure/Cycle Display Shows fluid pressure or cycle count, depending on mode selected. Displays J 1 through J 10 when in jog mode, page 35. 18 312065K Setup Setup Bolt bracket and mounting feet (MF) directly to NOTICE Proper system setup, start up, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty. truck or trailer bed. See page 40. 1. Locate Reactor a. Locate Reactor on a level surface. SeeDimensions page 40, for clearance and mounting hole dimensions. b. Do not expose Reactor to rain. NOTICE To prevent damage from tipping over and falling, proper care needs to be taken when lifting the Reactor. Bolt Reactor to original shipping pallet, to keep stable, before lifting. c. MF Use the casters to move Reactor to a fixed location, or bolt to shipping pallet and move with forklift. d. To mount on a truck bed or trailer, remove casters and secure rear axle with 15B805 mobile mounting bracket (MB), available separately. MB 259024_312065 FIG. 6 2. General equipment guidelines • Determine the correct size generator. Using the correct size generator and proper air compressor will enable the proportioner to run at a nearly constant RPM. Failure to do so will cause voltage fluctuations that can damage electrical equipment. Ensure the generator matches the voltage and phase of the proportioner. Use the following procedure to determine the correct size generator. a. List system components that use peak load requirements in watts. b. Add the wattage required by the system components. c. Perform the following equation: Total watts x 1.25 = kVA (kilovolt-amperes) d. Select a generator size that is equal to or greater than the determined kVA. • Use proportioner power cords that meet or exceed the requirements listed in Table 2. Failure to do so will cause voltage fluctuations that can damage 312065K electrical equipment. 19 Setup • Use an air compressor with constant speed head unloading devices. Direct online air compressors that start and stop during a job will cause voltage fluctuations that can damage electrical equipment. • Table 1: Electrical Requirements (kW/Full Load Amps) E SERIES Maintain and inspect the generator, air compressor, and other equipment per the manufacturer recommendations to avoid an unexpected shutdown. Unexpected equipment shutdown will cause voltage fluctuations that can damage electrical equipment. • Use a wall power supply with enough current to meet system requirements. Failure to do so will cause voltage fluctuations that can damage electrical equipment. 3. Electrical requirements See TABLE 1. Part No. Model Voltage (phase) 259025 249030 259034 259026 259031 259035 259057 259058 259059 E-20 E-20 E-20 E-30 E-30 E-30 E-30† E-30† E-30† 230V (1) 400V (3) 230V (3) 230V (1) 400V (3) 230V (3) 230V (1) 230V (3) 400V (3) Full Load Peak Amps* System Watts** 48 24 32 78 34 50 100 62 35 10,200 10,200 10,200 17,900 17,900 17,900 23,000 23,000 23,000 69 24 43 100 35 62 15,800 15,800 15,800 23,000 23,000 23,000 E-XP SERIES Installing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician connect power and ground to main power switch terminals, see page 21. Be sure your installation complies with all National, State and Local safety and fire codes. 259024 259029 259033 259028 259032 259036 * E-XP1 E-XP1 E-XP1 E-XP2 E-XP2 E-XP2 230V (1) 400V (3) 230V (3) 230V (1) 400V (3) 230V (3) Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less. ** E-20 and E-XP1 with 210 ft (64.1 m) hose; E-30 and E-XP2 with 310 ft (94.6 m) hose. † E-30 with 15.3 kW of heat. 20 312065K Setup 4. Connect electrical cord Power cord is not supplied. See Table 2. a. 230V, 1 phase: Using 5/32 or 4 mm hex allen wrench, connect two power leads to L1 and L2. Connect green to ground (GND). GND Table 2: Power Cord Requirements Part Model Cord Specification AWG (mm2) 259024 259025 259026 259028 259029 259030 259031 259032 259033 259034 259035 259036 259057 259058 259059 E-XP1 E-20 E-30 E-XP2 E-XP1 E-20 E-30 E-XP2 E-XP1 E-20 E-30 E-XP2 E-30 E-30 E-30 4 (21.2), 2 wire + ground 6 (13.3), 2 wire + ground 4 (21.2), 2 wire + ground 4 (21.2), 2 wire + ground 10 (5.3), 4 wire + ground 10 (5.3), 4 wire + ground 8 (8.4), 4 wire + ground 8 (8.4), 4 wire + ground 8 (8.4), 3 wire + ground 8 (8.4), 3 wire + ground 6 (13.3), 3 wire + ground 6 (13.3), 3 wire + ground 4 (21.2), 2 wire + ground 6 (13.3), 3 wire + ground 8 (8.4), 4 wire + ground L1 L2 ti2515b b. 230V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect green to ground (GND). GND L1 L2 L3 ti3248b c. 400V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND). GND L1 L3 L2 N ti2725a 312065K 21 Setup 5. Connect feed pumps a. Install feed pumps (K) in component A and B supply drums. See FIG. 1 and FIG. 2, pages 12 and 13. a. Recommended: Connect high pressure hose (R) to relief fittings (BA, BB) of both PRESSURE RELIEF/SPRAY valves, Route hose back to component A and B drums. See FIG. 1, page 12. b. Seal component A drum and use desiccant dryer (M) in vent. SA c. Install agitator (L) in component B drum, if necessary. BA SB R R d. Ensure A and B inlet valves (FV) are closed. BB b. FV TI10971a Supply hoses from feed pumps should be 3/4 in. (19 mm) ID. 6. Connect pressure relief lines TI10954a Alternately: Secure supplied bleed tubes (N) in grounded, sealed waste containers (H). See FIG. 2, page 13. 7. Install Fluid Temperature Sensor (FTS) The Fluid Temperature Sensor (FTS) is supplied. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions. 8. Connect heated hose See Heated Hose manual 309572 for detailed instructions on connecting heated hoses. Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpressure relief valves when set to SPRAY . Lines must be open so valves can The fluid temperature sensor (C) and whip hose (D) must be used with heated hose, see page 22. Hose length, including whip hose, must be 60 ft (18.3 m) minimum. automatically relieve pressure when machine is operating. If circulating fluid back to the supply drums, use high pressure hose rated to withstand the maximum working pressure of this equipment. 22 a. Turn main power OFF b. . Assemble heated hose sections, FTS, and whip hose. 312065K Setup c. Connect A and B hoses to A and B outlets on Reactor fluid manifold (FM). Hoses are color coded: red for component A (ISO), blue for component B (RES). Fittings are sized to prevent 9. Close gun fluid manifold valves A and B connection errors. FM HA ti2411a A HB 10. Connect whip hose to gun fluid manifold B Do not connect manifold to gun. TI10964a Manifold hose adapters (HA, HB) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose. d. Connect cables (Y). Connect electrical connectors (V). Be sure cables have slack when hose bends. Wrap cable and electrical connections with electrical tape. ti2417a 11. Pressure check hose See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage. Y V TI10956a 312065K 23 Setup 12. Ground system a. Component A (ISO) Pump: Keep reservoir (R) filled with Graco Throat Seal Liquid (TSL), Part 206995. Wet-cup piston circulates TSL through wet-cup, to carry away isocyanate film on displacement rod. a. Reactor: is grounded through power cord. See page 21. b. c. Spray gun: connect whip hose ground wire to FTS, page 22. Do not disconnect wire or spray without whip hose. R Fluid supply containers: follow your local code. d. Object being sprayed: follow your local code. e. Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity f. TI3765a-2 FIG. 7 b. To maintain grounding continuity when flushing or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun. 13. Supply wet cups with Throat Seal Liquid (TSL) Component B (Resin) Pump: Check felt washers in packing nut/wet-cup (S) daily. Keep saturated with Graco Throat Seal Liquid (TSL), Part No. 206995, to prevent material from hardening on displacement rod. Replace felt washers when worn or contaminated with hardened material. S Pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinching or amputation. Keep hands and fingers away from wet-cup during operation. Turn main power OFF TI3765a-1 before filling wet cup. 24 FIG. 8 312065K Startup Startup NOTICE Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty. a. Check that all Setup steps are complete. b. Check that inlet screens are clean before daily startup, page 37. c. Check level and condition of ISO lube daily, page 37. d. Turn on component B agitator, if used. e. Turn both PRESSURE RELIEF/SPRAY valves (SA, SB) to SPRAY Do not operate Reactor without all covers and shrouds in place. . SA SB 1. Check generator fuel level. Running out of fuel will cause voltage fluctuations that can damage electrical equipment. 2. Ensure the main breaker on the generator is in the off position. 3. Start the generator. Allow it to reach full operating temperature. TI10963a f. Start feed pumps. g. Open fluid inlet valves (FV). Check for leaks. 4. Close the bleed valve on the air compressor. FV 5. Switch on the air compressor starter and air dryer, if included. 6. Turn on power to the Reactor. TI10972a 7. Load fluid with feed pumps The Reactor is tested with oil at the factory. Flush out the oil with a compatible solvent before spraying. See page 39. 312065K 25 Startup 8. Set temperatures A Do not mix components A and B during startup. Always provide two grounded waste containers to keep component A and component B fluids separate. B h. Use feed pumps to load system. Hold gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves. °F °C Temperature Controls and Indicators, see page 15 ti2484a This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To avoid severe burns: • Do not touch hot fluid or equipment. • Allow equipment to cool completely before touching it. • Wear gloves if fluid temperature exceeds 110°F (43°C). a. Turn main power ON b. Press °F or °C . to change temperature scale. c. 26 Press to display target temperatures. 312065K Startup A d. To set heat zone target temperature, h. Hold to view electrical currents for each zone. press or until display shows desired temperature. Repeat for B i. and Hold to view heater control circuit board temperature. zones. For j. Manual current control mode only: zone only, if FTS is disconnected at startup, display will show hose current (0A). See step j, page 27. e. Press to display actual temperatures. When in manual current control mode, monitor hose temperature with thermometer. Install per instructions below. Thermometer reading must not exceed 160°F (71°C). Never leave machine unattended when in manual current control mode. If FTS is disconnected or display shows diagnostic code E04, turn main power switch OFF Do not turn on hose heat without fluid in hoses. then ON to clear diagnostic code and enter manual current control mode. f. Turn on heat zone by pressing display will show current to hose. Current . Preheat hose (15-60 min). Indicator will flash very slowly when fluid reaches target temperature. Display shows actual fluid temperature in is not limited by target temperature. Press or to adjust current setting. hose near FTS. Thermal expansion can cause overpressurization, resulting in equipment rupture and serious injury, including fluid injection. Do not pressurize system when preheating hose. To prevent overheating, install hose thermometer close to gun end, within operator view. Insert thermometer through foam cover of A component hose so stem is next to inner tube. Thermometer reading will be about 20°F less than actual fluid temperature. If thermometer reading exceeds 160°F (71°C), reduce current with g. Turn on ing 312065K A and B key. heat zones by press- for each zone. 27 Startup 9. Set pressure 10. Change pressure imbalance setting (optional) The pressure imbalance function (status code 24) detects conditions that can cause off-ratio spray, such as loss of feed pressure/supply, pump seal failure, clogged fluid inlet filter, or a fluid leak. ON / OFF PARK Code 24 (pressure imbalance) is set to an alarm as the default. To change to a warning, see Reactor Repair-Parts manual 312066. PSI BAR Motor Controls and Indicators, see page 17 a. Press b. . Press motor . Motor and pumps start. Display shows system pressure. Motor runs until setpoint is reached. c. Press or The pressure imbalance default is factory-set at 500 psi (3.5 MPa, 35 bar). For tighter ratio error detection, select a lower value. For looser detection or to avoid nuisance alarms, select a higher value. a. Turn main power switch OFF b. until display shows power switch ON desired fluid pressure. Display will show setpoint for 10 seconds, then change to actual pressure. If display shows J xx, unit is in jog mode. To exit jog mode, see page 35. d. To display cycle count, press To clear counter, press . and hold for 3 sec- or BAR , then turn main . Display will read dP500 for psi or dP_35 for bar. c. If display pressure is greater than setpoint pressure, trigger gun to reduce pressure. PSI Press and hold . Press or to select desired pres- sure differential (100-999 in increments of 100 psi, or 7-70 in increments of 7 bar). See Table 3. Table 3: Available Pressure Imbalance Settings PSI BAR 100 200 300 400 *500 7 14 21 28 *35 PSI 600 700 800 900 999 BAR 42 49 56 63 69 * Factor default setting. onds. d. Turn main power switch OFF e. Press PSI or BAR to change pressure to save changes. scale. 28 312065K Spraying Spraying 3. Attach gun fluid manifold. Connect gun air line. Open air line valve. 1. Engage gun piston safety lock. ti2543a ti2409a 4. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to 2. Close gun fluid manifold valves A and B. SPRAY . SA SB TI10963a ti2728a 5. Check that heat zones are on and temperatures are on target, page 26. 6. Press motor to start motor and pumps. 7. Check fluid pressure display and adjust as necessary, page 29. 312065K 29 Spraying 8. Check fluid pressure gauges (GA, GB) to ensure proper pressure balance. If imbalanced, reduce pressure of higher component by slightly turning PRESSURE RELIEF/SPRAY valve for that component toward PRESSURE RELIEF/CIRCULATION 9. Open gun fluid manifold valves A and B. , until gauges show balanced pressures. GA GB In this example, B side pressure is higher, so use the B side valve to balance pressures. ti2414a On impingement guns, never open fluid manifold valves or trigger gun if pressures are imbalanced. TI10963a 10. Disengage gun piston safety lock. ti2410a 11. Test spray onto cardboard. Adjust pressure and temperature to get desired results. 12. Equipment is ready to spray. 30 312065K Shutdown Shutdown NOTICE Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty. 1. Shut off A B , 4. Relieve pressure, page 32. 5. Turn off the air compressor and air dryer, if included. 6. Open air compressor bleed valve to relieve pressure and remove water from tank. 7. Turn off the main breaker on the generator. 8. Allow generator dwell time, per manufacturer recommendations, prior to shutdown. , and heat zones. 9. Close both fluid supply valves (FV). 2. Park pumps. a. Press b. . Trigger gun until pump A stops in the retracted position and the pressure of both pumps bleeds down. FV ti10971a 10. Shut down feed pumps as required. 3. Turn main power OFF 312065K . 31 Pressure Relief Procedure Pressure Relief Procedure fluid to waste containers or supply tanks. Ensure gauges drop to 0. 1. Relieve pressure in gun and perform gun shutdown procedure. See gun manual. SA SB 2. Close gun fluid manifold valves A and B. TI10955a 5. Engage gun piston safety lock. ti2421a 3. Shut off feed pumps and agitator, if used. 4. Turn PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION 32 . Route ti2409a 6. Disconnect gun air line and remove gun fluid manifold. 312065K Fluid Circulation Fluid Circulation Circulation Through Reactor 4. Turn main power ON . 5. Set temperature targets, see page 26. Turn on Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits. To circulate through gun manifold and preheat hose, see page 34. A and Do not turn on heat zones by pressing . heat zone unless hoses are already loaded with fluid. 6. Press 1. Follow Startup procedures, page 25. B to display actual temperatures. 7. Circulate fluid in jog mode until A and B temperatures reach targets. Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpressure relief valves when set to SPRAY . Lines must be open so valves can automatically relieve pressure when machine is operating. 2. See Typical Installation, with circulation, page 12. Route circulation lines back to respective component A or B supply drum. Use hoses rated at the maximum working pressure of this equipment. See Technical Data, page 41. 8. Turn on heat zone by pressing . 9. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to SPRAY . SA SB TI10963a 3. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION . SA SB TI10955a 312065K 33 Fluid Circulation Circulation Through Gun Manifold 2. Route circulation lines back to respective component A or B supply drum. Use hoses rated at the maximum working pressure of this equipment. See Typical Installation, without circulation, page 13. 3. Follow Startup procedures, page 25. Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits. Circulating fluid through the gun manifold allows rapid preheating of hose. 4. Turn main power ON . 5. Set temperature targets, see page 26. Turn on A 1. Install gun fluid manifold (P) on Part 246362 accessory circulation kit (CK). Connect high pressure circulation lines (R) to circulation manifold. , B , and heat zones by pressing . 6. Press to display actual temperatures. 7. Circulate fluid in jog mode until P CK A and B temperatures reach targets. R ti2767a 34 312065K Jog Mode Jog Mode Jog mode has two purposes: 4. Press motor • It can speed fluid heating during circulation. • It can ease pump repair/replacement. See repair manual. 5. Press to start motor. or to change jog speed (J1 through J10). 1. Turn main power on 2. Ensure motor . is OFF (LED is off; display may show dashes or pressure). 3. Press 312065K Jog speeds correlate to 3-30% of motor power, but will not operate over 700 psi (4.9 MPa, 49 bar) for either A or B. to select J1 (jog speed 1). 6. To exit jog mode, press until display shows dashes or current pressure. 35 Diagnostic Codes Diagnostic Codes Temperature Control Diagnostic Codes Temperature control diagnostic codes appear on temperature display. These alarms turn off heat. E99 clears automatically when communication is regained. Codes E03 through E06 can be cleared by pressing turn main power OFF . For other codes, then ON to clear. Code 01 Code Name Alarm Zone High fluid temperature Individual 02 High current Individual 03 No current Individual 04 FTS not connected Individual 05 Board overtemperature Individual 06 Loss of zone communication Individual 30 Momentary loss of communication All 99 Loss of display communication All See repair manual for corrective action. For hose zone only, if FTS is disconnected at startup, display will show hose current 0A. Motor Control Diagnostic Codes Motor control diagnostic codes E21 through E29 appear on pressure display. Warnings There are two types of motor control codes: alarms and warnings. Alarms take priority over warnings. Reactor will continue to run. Press See repair manual for corrective action. warning will not recur for a predetermined amount of time (varies for different warnings), or until main power is turned OFF Alarms to clear. A then ON . Alarms turn off motor and heat zones. Turn main power OFF then ON to clear. Alarms can also be cleared, except for code 23, by pressing 36 . Code No. Code Name Alarm or Warning 21 No transducer (component A) Alarm 22 No transducer (component B) Alarm 23 High pressure Alarm 24 Pressure imbalance Selectable; see repair manual 25 High line voltage Alarm 26 Low line voltage Alarm 27 High motor temperature Alarm 28 High current Alarm 29 Brush wear Warning 312065K Maintenance Maintenance Fluid Inlet Strainer Screen • Check wet cup TSL level daily. • Do not overtighten packing nut/wet cup. Throat u-cup is not adjustable. • Inspect fluid inlet strainer screens daily, see below. • Grease circulation valves weekly with Fusion grease (117773). The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required. Use clean chemicals and follow proper storage, transfer, and operating procedures, to minimize contamination of the A-side screen. TI10955a • Inspect ISO lubricant level and condition daily, see page 38. Refill or replace as needed. • Keep component A from exposure to moisture in atmosphere, to prevent crystallization. • Clean gun mix chamber ports regularly. See gun manual. • Clean gun check valve screens regularly. See gun manual. • Use compressed air to prevent dust buildup on control boards, fan, motor (under shield), and hydraulic oil coolers. • Keep vent holes on bottom of electrical cabinet open. Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations. 1. Close the fluid inlet valve at the pump inlet and shut off the appropriate feed pump. This prevents material from being pumped while cleaning the screen. 2. Place a container under the strainer manifold (59d) to catch fluid. Remove the strainer plug (59j). 3. Remove the screen (59g) from the strainer manifold. Thoroughly flush the screen with compatible solvent and shake it dry. Inspect the screen. If more than 25% of the mesh is blocked, replace the screen. Inspect the gasket (59h) and replace as required. 4. Ensure the pipe plug (59k) is screwed into the strainer plug (59j). Install the strainer plug with the screen (59g) and gasket (59h) in place and tighten. Do not overtighten. Let the gasket make the seal. 5. Open the fluid inlet valve, ensure that there are no leaks, and wipe the equipment clean. Proceed with operation. 59d 59g* 59h 59j 59k Ti10974a FIG. 9. Fluid Inlet Strainer 312065K 37 Maintenance Pump Lubrication System Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color darkens, or it becomes diluted with isocyanate. ST RT Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrication system minimizes exposure to moisture, but some contamination is still possible. RB LR Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks. TI10970a To change pump lubricant: 1. Relieve pressure, page 32. 2. Lift the lubricant reservoir (LR) out of the bracket (RB) and remove the container from the cap. Holding the cap over a suitable container, remove the check valve and allow the lubricant to drain. Reattach the check valve to the inlet hose. See FIG. 10. 3. Drain the reservoir and flush it with clean lubricant. RT ST LR 4. When the reservoir is flushed clean, fill with fresh lubricant. 5. Thread the reservoir onto the cap assembly and place it in the bracket. 6. The lubrication system is ready for operation. No priming is required. TI10969a FIG. 10. Pump Lubrication System 38 312065K Flushing Flushing • To flush feed hoses, pumps, and heaters separately from heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION lines (N). Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents. . Flush through bleed SA SB N • Flush out old fluid with new fluid, or flush out old fluid with a compatible solvent before introducing new fluid. • Use the lowest possible pressure when flushing. • All fluid components are compatible with common solvents. Use only moisture-free solvents. N TI10955a • To flush entire system, circulate through gun fluid manifold (with manifold removed from gun). • To prevent moisture from reacting with isocyanate, always leave the system dry or filled with a moisture-free plasticizer or oil. Do not use water. See page 10. Accessories Feed Pump Kits Heated Hoses Pumps, hoses, and mounting hardware to supply fluids to Reactor. Includes 246483 Air Supply Kit. See 309815. 50 ft (15.2 m) and 25 ft (7.6 m) lengths, 1/4 in. (6 mm), 3/8 in. (10 mm), or 1/2 in. (13 mm) diameter, 2000 psi (14 MPa, 140 bar) or 3500 psi (24 MPa, 241 bar). See 309572. 246483 Air Supply Kit Hoses and fittings to supply air to feed pumps, agitator, and gun air hose. Included in feed pump kits. See 309827. Heated Whip Hoses 10 ft (3 m) whip hose, 1/4 in. (6 mm) or 3/8 in. (10 mm) diameter, 2000 psi (14 MPa, 140 bar) or 3500 psi (24 MPa, 241 bar). See 309572. 246978 Circulation Kit Return hoses and fittings to make circulation system. Includes two 246477 Return Tube Kits. See 309852. Fusion Spray Gun Air purge gun, available in round or flat pattern. See 309550. 246477 Return Tube Kit Desiccant dryer, return tube, and fittings for one drum. Two included in 246978 Circulation Kit. See 309852. 248669 Conversion Kit Convert any E-XP2 to a E-30 with 15.3kW of heat. Include new pumps, bearing, and fitting to accomplish conversion. See manual 309574. 246085 Data Reporting Kit Records actual temperature, temperature setpoint, actual pressure, cycles, and diagnostic code data from Reactor. Downloads data to PC with Microsoft® Windows 98 or later. See 309867. 248848 Data Reporting Kit Records actual temperature, temperature setpoint, actual pressure, cycles, and diagnostic code data from Reactor. Downloads data to PC with Microsoftâ Windows 98 or later. Does not include interface module. See 309867. 312065K 39 Dimensions Dimensions Dimension A B C in. (mm) 46.0 (1168) 31.0 (787) 33.0 (838) A C B 40 TI10953a 312065K Technical Data Technical Data Category Maximum Fluid Working Pressure Data Models E-20 and E-30: 2000 psi (14 MPa, 140 bar) Model E-XP1: 2500 psi (17.2 MPa, 172 bar) Maximum Fluid Temperature Maximum Output Model E-XP2: 3500 psi (24.1 MPa, 241 bar) 190°F (88°C) Model E-20: 20 lb/min (9 kg/min) Model E-30: 30 lb/min (13.5 kg/min) Model E-XP1: 1 gpm (3.8 liter/min) Output per Cycle (A and B) Model E-XP2: 2 gpm (7.6 liter/min) Model E-20 and E-XP1: 0.0104 gal. (0.0395 liter) Model E-30: 0272 gal. (0.1034 liter) Line Voltage Requirement Model E-XP2: 0.0203 gal. (.0771 liter) Parts 259024, 259025, 259026, 259028, 259057: 195-264 Vac, 50/60 Hz Parts 259029, 259030, 259031, 259032, 259059: 338-457 Vac, 50/60 Hz Amperage Requirement Heater Power Parts 2590330, 259034, 259035, 259036, 259058: 195-264 Vac, 50/60 Hz See Table 1, page 19. Model E-20: 6000 Watts Model E-30 and E-XP1: 10200 Watts Sound Power, per ISO 9614-2 Models E-XP2 and E-30 with 15.3kW of heat: 15300 Watts Model E-20: 80 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm) Model E-30: 93.5 dB(A) at 1000 psi (7 MPa, 70 bar), 3.0 gpm (11.4 lpm) Model E-XP1: 80 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm) Model E-XP2: 83.5 dB(A) at 3000 psi (21 MPa, 210 bar), 1.0 gpm (3.8 lpm) Sound Pressure, 1 m from equipment Model E-20: 70.2 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm) Model E-30: 83.6 dB(A) at 1000 psi (7 MPa, 70 bar), 3.0 gpm (11.4 lpm) Model E-XP1: 70.2 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm) Fluid Inlets Fluid Outlets Model E-XP2: 73.6 dB(A) at 3000 psi (21 MPa, 210 bar), 1.0 gpm (3.8 lpm) 3/4 npt(f), with 3/4 npsm(f) union Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter Fluid Circulation Ports Weight Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter 1/4 npsm(m), with plastic tubing; 250 psi (1.75 MPa, 17.5 bar) maximum Model E-20 and E-XP1: 342 lb (155 kg) Model E-30: 400 lb (181kg) Wetted Parts Models E-XP2 and E-30 with 15.3kW of heat: 438 lb (198 kg) Aluminum, stainless steel, zinc plated, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene All other brand names or marks are used for identification purposes and are trademarks of their respective owners. 312065K 41 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211, Fax: 612-378-3505 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original Instructions. This manual contains English. MM 312065 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2007, Graco Inc. is registered to ISO 9001 www.graco.com Revised 09/2010
advertisement